Policy Replication

Technologies for Legionella Control in Premise Plumbing Systems: Scientific Literature Review

Docket document2024-02-08 · EPA · publication · EPA-HQ-OLEM-2023-0278-0126
RIN 2050-AH26 · Docket EPA-HQ-OLEM-2023-0278

Other documents for the same rulemaking (all, by stage)

2024-02-08 Federal RegisterListing of Specific PFAS as Hazardous Constituents
2024-02-08 Regulatory impact analysisThe Cost of Inaction: A socioeconomic analysis of environmental and health impacts linked to exposure to PFAS
2024-02-08 Regulatory impact analysisU.S. EPA (2023). Draft Economic Assessment of the Potential Costs, Benefits, and Other Impacts of the Proposed Rulemaking to List Specific PFAS as RCRA Hazardous Constituents. U.S. Environmental Protection Agency Office of Land and Emergency Management
2024-02-08 Regulatory impact analysisTechnical Guidance for Assessing Environmental Justice in Regulatory Analysis
2024-02-08 Regulatory impact analysisEconomic Analysis for the Proposed Per- and Polyfluoroalkyl Substances National Primary Drinking Water Regulation
2024-02-08 Docket documentRedline of Changes to Proposed Rule during OMB Review
2024-02-08 Docket documentPer- and Polyfluoroalkyl Substances Cleanup: Schedule, Status, and Cost Estimates
2024-02-08 Docket documentU.S. EPA. (2023). Public Comment Draft - Toxicity Assessment and Proposed Maximum Contaminant Level Goal (MCLG) for Perfluorooctanoic Acid (PFOA) (CASRN 335–67–1) in Drinking Water [EPA–822–P–23–005]
2024-02-08 Docket documentHazardous Waste and Home Values: An Analysis of Treatment and Disposal Sites in the U.S
2024-02-08 Docket documentSurvey of Insurance Coverage for PFAS Clinical Care
2024-02-08 Docket documentEx Situ Thermal Treatment of Perfluoroalkyl and Polyfluoroalkyl Substances
2024-02-08 Docket documentNational Report on Human Exposure to Environmental Chemicals
2024-02-08 Docket document2013 ACC/AHA Guideline on the Assessment of Cardiovascular Risk
2024-02-08 Docket documentITRC PFAS Technical and Regulatory Guidance Document, "Water and Soil Tables of Regulations, Guidance and Advisories for PFAS"
2024-02-08 Docket documentU.S. EPA. (2020). ORD Staff Handbook for Developing IRIS Assessments (Public Comment Draft, Nov 2020). EPA/600/R-20/137. EPA, Office of Research and Development, Washington, DC.
2024-02-08 Docket documentBudtz-Jorgensen and Grandjean. (2018). Application of benchmark analysis for mixed contaminant exposures: Mutual adjustment of perfluoroalkylate substances associated with immunotoxicity. PLoS One 13 (10): e0205388
2024-02-08 Docket documentSummary of 2021 RCRA Corrective Action Economic Benefits Study and Research Methodology
2024-02-08 Docket documentFact Sheet 2010 2015 PFOA Stewardship Program
2024-02-08 Docket documentPFAS Strategic Roadmap: DOE Commitments to Action 2022-2025
2024-02-08 Docket documentReport on Department of Defense’s Per- and Polyfluoroalkyl Substances Task Force Activities
2024-02-08 Docket documentPFAS Exposure Assessment Final Report: Findings Across Ten Exposure Assessment (EA) Sites
2024-02-08 Docket document2020 Census of Population and Housing
2024-02-08 Docket documentReport on Per- and Polyfluoroalkyl Substances Active Sites Cleanup Costs
2024-02-08 Docket documentPlan EJ 2014
2024-02-08 Docket documentU.S. EPA. (2023). Public Comment Draft—Toxicity Assessment and Proposed Maximum Contaminant Level Goal (MCLG) for Perfluorooctane Sulfonic Acid (PFOS) (CASRN 1763–23–1) in Drinking Water [EPA–822–P–23–007]
2024-02-08 Docket documentProtecting Firefighters from Adverse Substances Act or the PFAS Act
2024-02-08 Docket documentCorrective Measures Study Scope of Work
2024-02-08 Docket documentPerfluorooctanoic acid exposure and cancer outcomes in a contaminated community: A geographic analysis
2024-02-08 Docket documentOffice of Resource Conservation and Recovery Economics and Risk Analysis Staff Unit Cost Compendium
2024-02-08 Docket documentPrenatal Exposure to Perfluoroalkyl Substances and Birth Outcomes; An Updated Analysis from the Danish National Birth Cohort
2024-02-08 Docket documentProposed Public Health Goals for Perfluorooctanoic Acid and Perfluorooctane Sulfonic Acid in Drinking Water
2024-02-08 Docket documentPFAS Analytical Tools
2024-02-08 Docket documentFact Sheet: PFOA & PFOS Drinking Water Health Advisories
2024-02-08 Docket documentU.S. EPA. (2021). Human Health Toxicity Values for Hexafluoropropylene Oxide (HFPO) Dimer Acid and Its Ammonium Salt (CASRN 13252-13-6 and CASRN 62037- 80-3) Also Known as “GenX Chemicals.” U.S. Environmental Protection Agency Office of Water
2024-02-08 Docket documentChemicals Added to the Toxics Release Inventory Pursuant to Section 7321 of the National Defense Authorization Act
2024-02-08 Docket documentA Study of the Implementation of the RCRA Corrective Action Program
2024-02-08 Docket documentHousing Impacts of Hazardous Waste Cleanups
2024-02-08 Docket documentNational PFAS Testing Strategy
2024-02-08 Docket documentInitial Assessment of Per- and Polyfluoroalkyl Substances at Department of Energy Sites
2024-02-08 Docket documentFY 2023 Budget in Brief
2024-02-08 Docket documentU.S. EPA (2022). Transmittal of the Science Advisory Board Report titled, ‘‘Review of EPA’s Analyses to Support EPA’s National Primary Drinking Water Rulemaking for PFAS.’’ [EPA–SAB-22–008]
2024-02-08 Docket documentOccurrence of Per- and Polyfluoroalkyl Substances (PFAS) in Source Water and Their Treatment in Drinking Water
2024-02-08 Docket documentPesticides; Removal of PFAS Chemicals from Approved Inert Ingredient List for Pesticide Products
2024-02-08 Docket documentU.S. EPA. (2023). IRIS Toxicological Review of Perfluorodecanoic Acid (PFDA) and Related Salts (Draft Report). U.S. Environmental Protection Agency Office of Research and Development
2024-02-08 Docket documentImplementing Statutory Addition of Certain Per- and Polyfluoroalkyl Substances (PFAS) to the Toxics Release Inventory Beginning with Reporting Years 2021 and 2022
2024-02-08 Docket documentDesignation of Perfluorooctanoic Acid (PFOA) and Perfluorooctanesulfonic Acid (PFOS) as CERCLA Hazardous Substances
2024-02-08 Docket documentPrenatal Exposure to Endocrine Disrupting Chemicals and Risk of Being Born Small for Gestational Age
2024-02-08 Docket documentWillingness to Pay for Health Improvements Using Stated Preferences: Prevention Versus Treatment
2024-02-08 Docket documentAnkley et al. (2004). Partial life-cycle toxicity and bioconcentration modeling of perfluorooctanesulfonate in the northern leopard frog (Rana pipiens). Environmental Toxicology and Chemistry 23(11): 2745-2755
2024-02-08 Docket documentU.S. EPA (2016). Health effects support document for perfluorooctanoic acid (PFOA). U.S. Environmental Protection Agency Office of Water [EPA-822-R-16-003]
2024-02-08 Docket documentPerfluoroalkyl Sulfonates; Significant New Use Rule December 2002
2024-02-08 Docket documentChapter 70.75A RCW Dispositions: Firefighting Agents and Equipment – Toxic Chemical Use
2024-02-08 Docket documentMethods for Estimating Locations of Housing Units Served by Private Domestic Wells in the United States Applied to 2010
2024-02-08 Docket documentMaternal Serum Levels of Perfluoroalkyl Substances in Early Pregnancy and Offspring Birth Weight
2024-02-08 Docket documentTackling the Climate Crisis at Home and Abroad
2024-02-08 Docket documentU.S. EPA (2022). IRIS Toxicological Review of Perfluorobutanoic Acid (PFBA) and Related Salts (Final Report). U.S. Environmental Protection Agency Office of Research and Development
2024-02-08 Docket documentChanges to Reporting Requirements for Per- and Polyfluoroalkyl Substances and to Supplier Notifications for Chemicals of Special Concern; Community Right-to-Know Toxic Chemical Release Reporting
2024-02-08 Docket documentPFAS National Primary Drinking Water Regulation Rulemaking
2024-02-08 Docket documentMethod 537.1: Determination of Selected Per- and Polyfluorinated Alkyl Substances in Drinking Water by Solid Phase Extraction and Liquid Chromatography/Tandem Mass Spectrometry
2024-02-08 Docket documentPerfluoroalkyl Sulfonates; Significant New Use Rule March 2002

References: 302 extracted, 0 linked to papers

Page 2Download these results: CSV · JSON
Buse, H.Y., M.E. Schoen and N.J. Ashbolt. 2012. Legionellae in engineered systems and use of quantitative microbial risk assessment to predict exposure. Water Research, 46: 921-933.
journal articleNot linked to a paper · refsec
Carducci, A., M. Verani, and R. Battistini. 2010. Legionella in industrial cooling towers: monitoring and control strategies. Letters in Applied Microbiology, 50(1): 24-29.
journal articleNot linked to a paper · refsec
Carlson, B.H. and G.L. Amy, 2001. Ozone and biofiltration optimization for multiple objectives. Journal AWWA, 93:1:88.
journal articleNot linked to a paper · refsec
Casini, B., A. Buzzigoli, M.L. Cristina, A.M. Spagnolo, P. DelGiudice, S. Brusaferro, A. Poscia, U. Moscato, P. Valentini, A. Baggiani, and G. Privitera. 2014. Long-term effects of hospital water network disinfection on Legionella and other waterborne bacteria in an Italian university hospital. Infection Control and Hospital Epidemiology, 35(3): 293-299.
journal articleNot linked to a paper · refsec
Castagnetti, D., G. S. Mammano, and E. Dragoni. 2011. Effect of chlorinated water on the oxidative resistance and the mechanical strength of polyethylene pipes. Polymer Testing, 30(3); 277-285. Centers for Disease Control and Prevention (CDC). 1997. Sustained transmission of nosocomial Legionnaires’ disease – Arizona and Ohio. Morbidity and Mortality Weekly Report (MMWR), 46(19): 416-421. Centers for Disease Control and Prevention (CDC). 2000. Legionnaires’ disease associated with potting soil – California, Oregon and Washington, May-June 2000. Morbidity and Mortality Weekly Report (MMWR). 49: 777-778. Centers for Disease Control and Prevention (CDC). 2003. Guidelines for environmental infection control in health-care facilities. Recommendations of CDC and the Healthcare Infection Control Practices Advisory Committee (HICPAC). Morbidity and Mortality Weekly Report (MMWR), 52 (RR10): 1-42. Centers for Disease Control and Prevention (CDC). 2005. Legionellosis (Legionnaire's disease or Pontiac fever) case definition. Available online at: http://wwwn.cdc.gov/NNDSS/script/casedef.aspx?CondYrID=741&DatePub=1/1/2005%2012:0 0:00%20AM . Centers for Disease Control and Prevention (CDC). 2008. Surveillance for waterborne disease and outbreaks associated with drinking water and water not intended for drinking – United
journal articleNot linked to a paper · refsec · cited link
States, 2005-2006. Morbidity and Mortality Weekly Report Surveillance Summaries, 57: 39-62. Centers for Disease Control and Prevention (CDC). 2011. Legionellosis – United States, 20002009. Morbidity and Mortality Weekly Report (MMWR), 60: 1083-1086. Technologies for Legionella Control in Premise Plumbing Systems: Scientific Literature Review Centers for Disease Control and Prevention (CDC). 2012. Summary of notifiable diseases –
journal articleNot linked to a paper · refsec
United States, 2012. Morbidity and Mortality Weekly Report (MMWR), 61(53): 1-121. Centers for Disease Control and Prevention (CDC). 2013. Surveillance for waterborne disease outbreaks associated with drinking water and other non-recreational water — United States, 2009–2010. Morbidity and Mortality Weekly Report Surveillance Summaries, 62(35): 714-720. Centers for Disease Control and Prevention (CDC). 2015. Surveillance for waterborne disease outbreaks associated with drinking water — United States, 2011–2012. Morbidity and Mortality Weekly Report Surveillance Summaries, 64(31): 842-848. Centers for Disease Control and Prevention (CDC). 2016. Developing a water management program to reduce legionella growth & spread in buildings: A practical guide to implementing industry standards. Available at: http://www.cdc.gov/legionella/downloads/toolkit.pdf. Cervero-Aragó, S., R. Sommer, and R.M Araujo. 2014. Effect of UV irradiation (253.7 nm) on free Legionella and Legionella associated with its amoebae hosts. Water Research, 67 (2014): 299-309.
journal articleNot linked to a paper · refsec · cited link
Chen, C.H., L.C. Lin, Y. J. Chang, C.E. Liu, M.S. Soon, and C.S. Huang. 2013. Efficacy of copper-silver ionization for controlling fungal colonization in water distribution systems. Water and Health, 11(2): 277-280.
journal articleNot linked to a paper · refsec
Li, H.L. Chao, C.M. Ke, H.H. Lu, and C.L. Chang. 2008. Efficacy of point-of-entry coppersilver ionization system in eradicating Legionella pneumophila in a tropical tertiary care hospital: Implications for hospitals contaminated with Legionella in both hot and cold water. Hospital
research reportNot linked to a paper · refsec
Huang, H.L. Chao, C.H. Li, C.M. Ke, and Y.S. Lin. 2005. Abbreviated duration of superheatand-rush and disinfection of taps for Legionella disinfection: Lessons learned from failure. American Journal of Infection Control, 33(10): 606-610.
journal articleNot linked to a paper · refsec
Chord, F., P. Fascia, F. Mallaval, J. Cornillon, L. Roesch, B. Pozzetto, F. Grattard, P. Berthelot. 2011. Chlorine dioxide for Legionella spp. disinfection: A danger for cross-linked polyethylene pipes? Hospital Infection, 78(3): 242-243.
journal articleNot linked to a paper · refsec
Cirillo, J.D., S.L. Cirillo, L. Yan, L.E. Bermudez, S. Falkow, and L.S. Tompkins. 1999. Intracellular growth in Acanthamoeba castellanii affects monocyte entry mechanisms and enhances virulence of Legionella pneumophila. Infection and Immunity, 67(9): 4427-4434.
journal articleNot linked to a paper · refsec
Colbourne, J.S. and P.J. Dennis. 1989. The ecology and survival of Legionella pneumophila. Water and Environment, 3: 345-350. Technologies for Legionella Control in Premise Plumbing Systems: Scientific Literature Review
journal articleNot linked to a paper · refsec
Collier, S.A., L.J. Stockman, L.A. Hicks, L.E. Garrison, F.J. Zhou, and M.J. Beach. 2012. Direct healthcare costs of selected diseases primarily or partially transmitted by water. Epidemiology and Infection, 140: 2003-2013.
journal articleNot linked to a paper · refsec
Coniglio, M.A., N. Andolfi, G. Faro, M.B. Pellegrino, A. Sgalambro, G. D’Aquila, A. Spina, and S. Melada. 2015. Continuous disinfection by monochloramine on domestic hot water system of health-care facilities for the control of Legionella contamination in Italy. Journal of Health
journal articleNot linked to a paper · refsec
Science, 3: 11-17. Cooper, I.R. and G.W. Hanlon. 2009. Resistance of Legionella pneumophila serotype 1 biofilms to chlorine-based disinfection. Journal of Hospital Infection, 74 (2010): 152-159.
journal articleNot linked to a paper · refsec
Antunes, S. Almeida, A. Mendes, M. Guerreiro, D.A. Sampaio, L. Vieira, J. Machado, M.J. Simões, P. Gonçalves, and J.P. Gomes. 2016. Probable person-to-person transmission of Legionnaires’ disease. New England Journal of Medicine, 374:497-498. Available online at: http://www.nejm.org/doi/full/10.1056/NEJMc1505356.
journal articleNot linked to a paper · refsec · cited link
Craun, G.F., J.M. Brunkard, J.S. Yoder, V.A. Roberts, J. Carpenter, T. Wade, R.L. Calderon, J.M. Roberts, M.J. Beach, and S.L. Roy. 2010. Causes of outbreaks associated with drinking water in the United States from 1971 to 2006. Clinical Microbiology Reviews, 23(3): 507-528.
journal articleNot linked to a paper · refsec
Cristino, S., P.P. Legnani, and E. Leoni. 2012. Plan for the control of Legionella infections in long-term care facilities: Role of environmental monitoring. International Journal of Hygiene and Environmental Health, 215(2012): 279-285.
journal articleNot linked to a paper · refsec
Cunha, B.A. 2006. The atypical pneumonias: Clinical diagnosis and importance. Clinical Microbiology and Infection, 12(Suppl. 3): 12-24.
research reportNot linked to a paper · refsec
Cunliffe, D.A. 1990. Inactivation of Legionella pneumophila by monochloramine. Applied
research reportNot linked to a paper · refsec
Bacteriology, 68: 453-459. Daeschlein, G., W.H. Krüger, C. Selepko, M. Rochow, G. Dölken, and A. Kramer. 2007. Hygienic safety of reusable tap water filters (GermLyser®) with an operating time of 4 or 8 weeks in a haematological oncology transplant unit. BMC Infectious Diseases, 7:45.
journal articleNot linked to a paper · refsec
Darelid, J., S. Löfgrenm, and B.E. Malmvall. 2002. Control of nosocomial Legionnaires' disease by keeping the circulating hot water temperature greater than 55 degrees C: Experience from a 10-year surveillance programme in a district general hospital. Hospital Infection, 50(3): 213-219. de Beer, D., R. Srinivasan, and P.S. Stewart. 1994. Direct measurement of chlorine penetration into biofilms during disinfection. Applied and Environmental Microbiology, 60(12): 4339–4344.
journal articleNot linked to a paper · refsec
Declerk, P. 2010. Biofilms: the environmental playground of Legionella pneumophila. Environmental Microbiology, 12(3): 557-566. Technologies for Legionella Control in Premise Plumbing Systems: Scientific Literature Review
journal articleNot linked to a paper · refsec
Wortham, A. Beaudoin, M.L. Casey, C. Marriott, A.M. Ludwig, A.F. Sonel, R.R. Muder, and L.A. Hicks. 2015. The importance of clinical surveillance in detecting Legionnaires’ disease with a Legionella disinfection system – Pennsylvania, 2011-2012. Clinical Infectious Disease. 60: 1596 - 602.
journal articleNot linked to a paper · refsec
Dennis, P.J., D. Green, and B.P.C. Jones. 1984. A note on the temperature tolerance of Legionella. Journal of Applied Bacteriology. 56: 349 – 350.
journal articleNot linked to a paper · refsec
Dietrich, A.M. 2009. The sense of smell: Contributions of orthonasal and retronasal perception applied to metallic flavor of drinking water. Journal of Water Supply: Research and Technology – AQUA, 58(8): 562-570.
journal articleNot linked to a paper · refsec
Dietrich, A.M., R. Hoehn, and C.E. Via. 1991. Taste and odor problems associated with chlorine dioxide. Denver, Colo.: Water Research Foundation and AWWA.
research reportNot linked to a paper · refsec
Ditommaso, S., M. Giacomuzzi, M. Gentile, A. R. Moiraghi, and C. M. Zotti. 2010. Effective environmental sampling strategies for monitoring Legionella spp. contamination in hot water systems. American Journal of Infection Control, 38(5): 344-349.
journal articleNot linked to a paper · refsec
Jarraud. 2004. Clinical and environmental distributions of Legionella strains in France are different. Journal of Clinical Microbiology, 42(1): 458-60.
journal articleNot linked to a paper · refsec
Domingue, E.L., R.L. Tyndall, W.R. Mayberry, and O.C. Pancorbo. 1988. Effects of three oxidizing biocides on Legionella pneumophila serogroup 1. Applied and Environmental
research reportNot linked to a paper · refsec
Mallison, B. Politi, M.E. Potter, and W. Schaffner. 1979. Legionnaires’ disease in Kingsport, Tennessee. Annals of Internal Medicine, 90: 569-573.
journal articleNot linked to a paper · refsec
Donlan, R., R. Murga, J. Carpenter, E. Brown, R. Besser, and B. Fields. 2002. Monochloramine disinfection of biofilm-associated Legionella pneumophila in a potable water model system. In:
research reportNot linked to a paper · refsec
Donohue, M.J., K.O. O’Connell, S.J. Vesper, J.H. Mistry, D. King, M. Kostich, and S. Pfaller. 2014. Widespread molecular detection of Legionella pneumophila serogroup 1 in cold water taps across the United States. Environmental Science & Technology, 48: 3145-3152.
journal articleNot linked to a paper · refsec
Drake, P.L. and K.J. Hazelwood. 2005. Exposure-related health effects of silver and silver compounds: A review. Annals of Occupational Hygiene, 49: 575-585. Technologies for Legionella Control in Premise Plumbing Systems: Scientific Literature Review
journal articleNot linked to a paper · refsec
DSMZ. 2014. List of prokaryotic names validly published. Braunschweig, Germany. Available online at: http://www.dsmz.de/fileadmin/Bereiche/ChiefEditors/BacterialNomenclature/DSMZ_Bactnames .pdf.
research reportNot linked to a paper · refsec · cited link
Ducret, A., M. Chabalier, and S. Dukan. 2014. Characterization and resuscitation of ‘nonculturable’ cells of Legionella pneumophila. BMC Microbiology, 14: 3-10.
journal articleNot linked to a paper · refsec
Wagener, J. Goepfert, J. Bond, J. Hannigan, and D. Rogers. 2014. Evaluation of a new monochloramine generation system for controlling Legionella in building hot water systems. Infection Control and Hospital Epidemiology, 35(11): 1356-1363.
journal articleNot linked to a paper · refsec
Oberti, M.H. Rodier, S. Soreau, F. Wallet, and Y. Héchard. 2011. Efficiency of water disinfectants against Legionella pneumophila and Acanthamoeba. Water Research, 45: 10871094.
research reportNot linked to a paper · refsec
Dyck, A., M. Exner, and A. Kramer. 2007. Experimental based experiences with the introduction of a water safety plan for a multi-located university clinic and its efficacy according to WHO recommendations. BMC Public Health, 7:34.
research reportNot linked to a paper · refsec
Dziewulski, D.M., E. Ingles, N. Codru, J. Strepelis, and D. Schoonmaker-Bopp. 2015. Use of copper-silver ionization for the control of legionellae in alkaline environments at health care facilities. American Journal of Infection Control, 43(9): 971-976.
journal articleNot linked to a paper · refsec
Edelstein, P.H. 2007. Legionella*. In Manual of clinical microbiology, 9th ed., P.R. Murray (ed.). p. 835-849. Washington, DC: ASM Press.
research reportNot linked to a paper · refsec
Edelstein, P.H., R.E. Whittaker, R.L. Kreiling, and C.L. Howell. 1982. Efficacy of ozone in eradication of Legionella pneumophila from hospital plumbing fixtures. Applied and Environmental Microbiology, 44(6): 1330-1334.
journal articleNot linked to a paper · refsec
Edwards, M. and A. Dudi. 2004. Role of chlorine and chloramines in corrosion of lead-bearing plumbing materials. Journal AWWA, 96(10): 69-81.
journal articleNot linked to a paper · refsec
Edwards, M., J.F. Ferguson, and S.H. Reiber. 1994. The pitting corrosion of copper. Journal
journal articleNot linked to a paper · refsec
AWWA, 86: 74-90. Edwards, M., S. Jacobs, and R.J. Taylor. 2000. The blue water phenomenon. Journal AWWA, 92(7): 72-82.
journal articleNot linked to a paper · refsec
Escoll, P., M. Rolando, L. Gomez-Valero and C. Buchrieser. 2013. From amoeba to macrophages: Exploring the molecular mechanisms of Legionella pneumophila infection in both hosts. Current Topics in Microbiology and Immunology, 376: 1-34. Technologies for Legionella Control in Premise Plumbing Systems: Scientific Literature Review European Centre for Disease Prevention and Control (ECDC). 2016. Legionnaires’ disease in
journal articleNot linked to a paper · refsec
Europe, 2014. Available at: http://ecdc.europa.eu/en/publications/Publications/legionnaresdisease-europe-2014.pdf.
research reportNot linked to a paper · refsec · cited link
Euser S.M., J.P. Bruin, P. Brandsema, L. Reijnen, S.A. Boers, and J.W. Den Boer. 2013. Legionella prevention in the Netherlands: An evaluation using genotype distribution. European Journal of Clinical Microbiology & Infectious Diseases, 32(8): 1017-22.
journal articleNot linked to a paper · refsec
Ezzeddine, H., C. Van Ossel, M. Delmée, and G. Wauters. 1989. Legionella spp. in a hospital hot water system: Effect of control measures. Journal of Hospital Infection, 13(2): 121-131.
journal articleNot linked to a paper · refsec