Technologies for Legionella Control in Premise Plumbing Systems: Scientific Literature Review
Other documents for the same rulemaking (all, by stage)
References: 302 extracted, 0 linked to papers
Knudson, 1985 No data Knudson, 1985 Oguma et al., 2004 Oguma et al., 2004 Philadelphia 1 (with light repair) Philadelphia 1 ATCC33152 Philadelphia 1 ATCC33152 Notes:
UV disinfection does not produce a disinfectant residual (USEPA, 2007). Also, when UV disinfection is applied to waters containing a disinfectant residual, the residual may be diminished following treatment with UV (USEPA, 2006c). Therefore, water treated using only
UV disinfection (WHO, 2011). Light transmission through water is impaired by particulates. Disinfectant type and residual – Some reactor components may not be tolerant of certain disinfectants or high doses, so UV equipment manufacturers should be consulted about exposure of UV reactors to chemical disinfectants.
UV reactors, like other Legionella treatment options, require routine maintenance to ensure that the UV dose remains adequate for inactivation of pathogens. Some of the basic maintenance items include cleaning the quartz sleeves housing the lamps and periodically replacing the lamps, as their output decreases with time. Most UV lamps installed in smaller reactors will typically be rated for 8,000–12,000 hours of operation (one year of continuous operation equals 8,736 hours). To better understand the lamp output over time, premise plumbing operators may want to consult with the UV equipment manufacturer (USEPA, 2006c). In addition, some reactor components can be affected by disinfectants, including chlorine, added prior to the reactor, requiring additional maintenance. For a detailed list of recommended maintenance activities for a UV reactor, please see EPA’s Ultraviolet Disinfection Guidance Manual for the Final Long Term 2 Enhanced Surface Water Treatment Rule (USEPA, 2006c). 2.3.6 Ozone 2.3.6.1 Background Ozone is used in drinking water treatment for disinfection and oxidation (USEPA, 1999d, 2007). It is generated on-site as a gas using either air or liquid oxygen and is then transferred (dissolved) into the water phase. When dissolved in water, molecular ozone (O3) is unstable and decomposes to hydroxyl radical, which is a stronger and typically more reactive oxidizing agent than molecular ozone. Ozone decomposes quickly during water treatment (USEPA, 1999d, 2007).
MCL of 10 µg/L. The disinfection process of a PWS will likely have transformed any bromide in water to organically bound bromine or inorganic bromamines. In either case, these forms of bromine are less likely to contribute to bromate formation via an ozonation process in a premise plumbing system. As such, bromate formation may not be as relevant as in the water treatment plant. Other ozonation byproducts such as aldehydes and organic acids are more readily biodegradable and may contribute to assimilable organic carbon (AOC) and hence biological growth in the distribution system. In addition, these ozonation byproducts are more likely to form some types of DBPs upon chlorination or chloramination (Carlson and Amy, 2001; Shah and Mitch, 2012).
However, these general concepts regarding ozonation pertain to treatment of water at the plant. Technologies for Legionella Control in Premise Plumbing Systems: Scientific Literature Review Ozonation of water that has already undergone treatment, including exposure to a chlorine or chloramine residual in the distribution system en route to the building (e.g., hospital) has not been studied to a great extent. Therefore, impacts of ozonation on AOC or DBP formation in a premise plumbing system are still unclear. Loret et al. (2005) observed corrosion marks on mild and galvanized steel coupons installed in pipe loops for ozone treatment that were similar to corrosion effects caused by other disinfectants (chlorine, chloramine, chlorine dioxide and CSI), except that the coupons exposed to CSI also had copper deposits. 2.3.6.4 Operational Conditions As water temperature increases, ozone disinfection efficiency increases (USEPA, 1999d).
However, an inadequate temperature for the superheat (less than 65 degrees C, or 149 degrees F) or a short flush time (such as five minutes) is ineffective for the control of Legionella, as experienced at some hospitals (Chen et al., 2005). Even 70 degrees C may allow some bacteria to survive and acquire resistance (Allegra et al., 2011). The shock treatment may not provide longterm control of Legionella if the premise plumbing system does not maintain a proper temperature or a residual chlorine level. Allegra et al. (2011) tested the heat susceptibility of Legionella strains isolated from hot water in four hospital distribution systems over several years. The authors compared susceptibility of each group of strains using samples collected prior to and following heat treatment in the distribution system. They exposed Legionella from each sample to 70 degrees C (158 degrees F) for 30 minutes in the laboratory and determined the percentage of viable and VBNC cells remaining using flow cytometry. Strains of L. pneumophila serogroup 1 demonstrated highly variable heat resistance (mean percentage of viable and
PWS) as well as their purposes. The appropriate measures depend on those characteristics and purposes. A risk management approach, including good design and engineering, can ensure a comprehensive preventative method is followed to address potential health risks related to the premise plumbing system. See Section 2.2 of this document for information on risk management approaches. For additional information on how to develop and implement a risk management program to reduce risks from Legionella in premise plumbing systems see the CDC’s guidance, Developing a Water Management Program to Reduce Legionella Growth & Spread in Buildings: A Practical Guide to Implementing Industry Standards (CDC, 2016). Q10. Does EPA regulate Legionella?
EPA regulates Legionella under the Surface Water Treatment Rule (SWTR). The SWTR has treatment technique requirements to control for Giardia and viruses. The SWTR’s treatment technique requirements presume that if sufficient treatment is provided to control for Giardia and viruses (i.e., 3-log (99.9-percent) inactivation of Giardia and 4-log (99.99-percent) inactivation of viruses), then Legionella risks will also be controlled. In addition, the Revised Total Coliform Rule (USEPA, 2013a) and the Ground Water Rule (USEPA, 2006a) have treatment technique requirements that address bacteria. Corrective actions related to treatment technique violations may provide some control of Legionella. All of these rules apply to PWSs. They would not apply to premise plumbing systems unless the facility is a regulated PWS. See response to Question 4. Technologies for Legionella Control in Premise Plumbing Systems: Scientific Literature Review Q11. What treatment technologies does EPA approve for control of Legionella in drinking water?
Abdel-Nour, M., C. Duncan, D.E. Low, and C. Guyard. 2013. Biofilms: The stronghold of Legionella pneumophila. International Journal of Molecular Sciences, 14: 21660-21675.
Abdel-Nour, M., C. Duncan, A. Prashar, C. Rao, C. Ginevra, S. Jarraud, D. Low, A. Ensminger, M. Terebiznik, and C. Guyard. 2014. The Legionella pneumophila collagen-like protein mediates sedimentation, autoaggregation, and pathogen-phagocyte interactions. Applied and Environmental Microbiology, 80(4): 1441-1454.
Addiss, D.G., J.P. Davis, M. LaVenture, P.J. Wand, M.A. Hutchinson, and R.M. McKinney. 1989. Community-acquired Legionnaires' disease associated with a cooling tower: evidence for longer-distance transport of Legionella pneumophila. American Journal of Epidemiology, 130(3): 557–568.
Aieta, E.M. and J.D. Berg. 1986. A review of chlorine dioxide in drinking water treatment. Journal AWWA, 78(6): 62-72.
Albright, C.F., R. Nachum, and M.D. Lechtman. 1967. Development of an electrolytic silver-ion generator for water sterilization in Apollo spacecraft water systems. Apollo Applications Program. Final Report Prepared for Manned Spacecraft Center, NASA, Houston, Texas. Report No. 67-2158.
Allegra, S., F. Grattard, F. Girardot, S. Riffard, B. Pozzetto, and P. Berthelot. 2011. Longitudinal evaluation of the efficacy of heat treatment procedures against Legionella spp. in hospital water systems by using a flow cytometric assay. Applied and Environmental Microbiology, 77(4): 1268–1275. doi:10.1128/AEM.02225-10
Allen, J.G., T.A. Myatt, D.L. MacIntosh, J.F. Ludwig, T.Minegishi, J.H. Stewart, B.F. Connors, M.P. Grant, and J.F. McCarthy. 2012. Assessing risk of health care-acquired Legionnaires’ disease from environmental sampling: The limits of using a strict percent positivity approach. American Journal of Infection Control, 40: 917 – 921.
Frere. 2013. VBNC Legionella pneumophila cells are still able to produce virulence proteins. Water Research, 47(17): 6606-6617. American Industrial Hygiene Association (AIHA). 2015. Recognition, evaluation, and control of Legionella in building water systems. Kerbel, W., Krause, J.D., B.G. Shelton, and J.P.
Springston, eds. American Society for Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE). 2000. Guideline 12-2000. Minimizing the risk of legionellosis associated with building water systems. American Society for Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE). 2015.
ANSI/ASHRAE Standard 188-2015 Legionellosis: Risk management for building water systems. Technologies for Legionella Control in Premise Plumbing Systems: Scientific Literature Review American Water Works Association (AWWA). 2012. ANSI-AWWA Standard F110 - ultraviolet disinfection systems for drinking water. American Water Works Association, Denver, CO. American Water Works Association (AWWA). 2013. Manual M56. Nitrification prevention and control in drinking water. 2nd edition. American Water Works Association, Denver CO. American Water Works Association (AWWA) Disinfection Systems Committee. 2008. Committee report: Disinfection survey, part 1 – recent changes, current practices and water quality. Journal AWWA, 100(10): 76-90.
Andreozzi, E., A. Di Cesare, L. Sabatini, E. Chessa, D. Sisti, M. Rocchi, and B. Citterio. 2014. Role of biofilm in protection of the replicative form of Legionella pneumophila. Current
Microbiology, 69(6): 769-774. Antopol, S.C. and P.D. Ellner. 1979. Susceptibility of Legionella pneumophila to ultraviolet radiation. Applied and Environmental Microbiology, 38(2): 347-348.
Araya, M., B. Chen, L.M. Klevay, J.J. Strain, L. Johnson, P. Robson, W. Shi, F. Nielsen, H. Zhu, M. Olivares, F. Pizzarro, and L.T. Haber. 2003a. Confirmation of an acute no-observed-adverseeffect and low-observed-adverse-effect level for copper in bottled drinking water in a multi-site international study. Regulatory Toxicology and Pharmacology, 38(3): 389–399.
Pizarro, L. Johnson, and K.A. Poirier. 2001. Determination of an acute no-observed-adverseeffect level (NOAEL) for copper in water. Regulatory Toxicology and Pharmacology, 34(2): 137–145.
Araya, M., M. Olivares, F. Pizarro, M. Gonzalez, H. Speisky, and R. Uauy. 2003b. Gastrointestinal symptoms and blood indicators of copper load in apparently healthy adults undergoing controlled copper exposure. American Journal of Clinical Nutrition, 77(3): 646–650.
Araya, M., M. Olivares, F. Pizarro, A. Llanos, G. Figueroa, and R. Uauy. 2004. Communitybased randomized double-blind study of gastrointestinal effects and copper exposure in drinking water. Environmental Health Perspectives, 112(10): 1068–1073.
Araya, M., C. Peña, F. Pizarro, and M. Olivares. 2003c. Gastric response to acute copper exposure. The Science of the Total Environment, 303(3):253–257.
Ashbolt, N. 2015. Environmental (Saprozoic) pathogens of engineered water systems: understanding their ecology for risk assessment and management. Pathogens, 4: 390-405.
Finley, W.H. Gaze, T. Heberer, J. Lawrence, D.G.J. Larsson, S.A. McEwen, J. Ryan, J. Schönfeld, P. Silley, J.R. Snape, C. van den Eede, E. Topp. 2013. Human health risk assessment (HHRA) for environmental development and transfer of antibiotic resistance. Environmental Health Perspectives, 121:993-1001. Technologies for Legionella Control in Premise Plumbing Systems: Scientific Literature Review
ASTM D5952-08 (2015). Standard guide for the inspection of water systems for Legionella and the investigation of possible outbreaks of legionellosis (Legionnaires' disease or Pontiac fever). ASTM International, West Conshohocken, PA.
Pace, J.E. Stout. 2015. Effect of monochloramine treatment on the microbial ecology of Legionella and associated bacterial populations in a hospital hot water system. Systematic and Applied Microbiology, 38 (3): 198-205.
Baron, J.L., T. Peters, R. Shafer, B. MacMurray, and J.E. Stout. 2014b. Field evaluation of a new point-of-use faucet filter for preventing exposure to Legionella and other waterborne pathogens in health care facilities. American Journal of Infection Control, 42: 1193-1196.
Baron, J. L., A. Vikram, S. Duda, J. E. Stout, and K. Bibby. 2014a. Shift in the microbial ecology of a hospital hot water system following the introduction of an on-site monochloramine disinfection system. PLOS ONE. 9(7).
Barrette, W.C., D.M. Hannum, W.D. Wheeler, and J.K. Hurst. 1989. General mechanism for the bacterial toxicity of hypochlorous acid: Abolition of ATP production. Biochemistry, 28: 91729178.
Barnett, T., Pinna, G., Robson, J., Paterson, D., Walker, M., Schembri, M., and Beatson, S. 2016. Hospital-wide eradication of a nosocomial Legionella pneumophila serogroup 1 outbreak. Clinical Infectious Disease. 62: 273-279. Bédard, E., S. Fey, D. Charron, C. Lalancette, P. Cantin, P Dolcé, C. Laferrière, E. Déziel, and M. Prévost. 2015. Temperature diagnostic to identify high risk areas and optimize Legionella pneumophila surveillance in hot water distribution systems. Water Research, 71: 244-256. Bédard E., I. Boppe, S. Kouamé, P. Martin, L. Pinsonneault, L. Valiquette, J. Racine, M. Prévost. 2016. Combination of heat shock and enhanced thermal regime to control the growth of a persistent Legionella pneumophila strain. Pathogens 5(2). doi:10.3390/pathogens5020035
Benin, A.L., R.F. Benson, K.E. Arnold, A.E. Fiore, P.G. Cook, L.K. Williams, B. Fields, and R.E. Besser. 2002. An outbreak of travel-associated Legionnaires disease and Pontiac fever: The need for enhanced surveillance of travel-associated legionellosis in the United States. Journal of Infectious Diseases, 185 (2002): 237-243.
Berg, J.D., J.C. Hoff, P.V. Roberts, and A. Matin. 1988. Resistance of bacterial subpopulations to disinfection by chlorine dioxide. Journal AWWA, 80(9): 115-119.
Berk, S.G., R.S. Ting, G.W. Turner, and R.J. Ashburn. 1998. Production of respirable vesicles containing live Legionella pneumophila cells by two Acanthamoeba spp. Applied and Environmental Microbiology, 64: 279-286. Technologies for Legionella Control in Premise Plumbing Systems: Scientific Literature Review
Best, M., V.L. Yu, J.E. Stout, R.R. Muder, A. Goetz, and F. Taylor. 1983. Legionella in the hospital water supply: Epidemiologic link with disease and evaluation of a method of control of nosocomial Legionnaires’ disease and Pittsburgh pneumonia. Lancet, 2: 307-310.
Biurrun, A., L. Caballero, C. Pelaz, E. León, A. Gago, 1999. Treatment of a Legionella pneumophila-colonized water distribution system using copper-silver ionization and continuous chlorination. Infection Control and Hospital Epidemiology, 20(6): 426-428.
Blanc, D.S., P. Carrara, G. Zanetti, and P. Francioli. 2005. Water disinfection with ozone, copper and silver ions, and temperature increase to control Legionella: seven years of experience in a university teaching hospital. Hospital Infection, 60: 69-72.
Melcher. 1993. Nosocomial Legionnaires’ disease: Aspiration as a primary mode of disease acquisition. The American Journal of Medicine, 95: 16-22.
Bohach, G.A. and I. S. Snyder. 1983. Cyanobacterial stimulation of growth and oxygen uptake by Legionella pneumophila. Applied and Environmental Microbiology, 46(2): 528–531.
Bollin, G.E., J.F. Plouffe, M.F. Para, and B. Hackman. 1985. Aerosols containing Legionella pneumophila generated by shower heads and hot-water faucets. Applied and Environmental
Microbiology, 50(5): 1128-1131. Bondarczuk, K. and Z. Piotrowska-Seget. 2013. Molecular basis of active copper resistance mechanisms in Gram-negative bacteria. Cell Biology Toxicology, 29: 397-405.
Borella, P., E. Guerrieri, I. Marchesi, M. Bondi, and P. Messi. 2005a. Water ecology of Legionella and protozoan: environmental and public health perspectives. Biotechnology Annual
Review, 11: 355-380. Borella, P., S. Stampi, G. Stancanelli, V. Romano-Spica, M. Triassi, I. Marchesi, A. Bargellini, D. Tatò, C. Napoli, F. Zanetti, E. Leoni, M. Moro, S. Scaltriti, G. Ribera D'Alcalà, R. Santarpia and S. Boccia. 2005b. Legionella contamination in hot water of Italian hotels. Applied and Environmental Microbiology, 71(10): 5805-5813.
Fantone, and C. Engleberg. 1996. Co-inoculation with Hartmannella vermiformis enhances replicative Legionella pneumophila lung infection in a murine model of Legionnaires' disease. Infection and Immunity, 64: 2449-2456.
Buse, H.Y. and N.J. Ashbolt. 2011. Differential growth of Legionella pneumophila strains within a range of amoebae at various temperatures associated with in-premise plumbing. Letters in Applied Microbiology, 53: 217-224.
Buse, H.Y. and N.J. Ashbolt. 2012. Counting Legionella cells within single amoeba host cells. Applied and Environmental Microbiology, 78(6): 2070-2072. Technologies for Legionella Control in Premise Plumbing Systems: Scientific Literature Review
Buse, H. Y., J. Lu, I. T. Struewing, N. J. Ashbolt. 2013. Preferential colonization and release of Legionella pneumophila from mature drinking water biofilms grown on copper versus unplasticized polyvinylchloride coupons. International Journal of Hygiene and Environmental