NIOSH Manual of Analytical Methods (NMAM), 5th Edition, Section 2
Other documents for the same rulemaking (all, by stage)
References: 1,700 extracted, 0 linked to papers
[2] Institut fur Arbeitsschutz der Deutschen Gesetzlichen Unfallversicherung [2013]. GESTIS database on hazardous substances (German Social Accident Insurance). Sankt Augustin, FRG: [http://www.dguv.de/ ifa/GESTIS ]. Data accessed April 2014.
[4] Reynolds JM, Siso MC, Perkins JB [2004]. Backup Data Report for NIOSH 9109, Methamphetamine and illicit drugs, precursors, and adulterants on wipes by solid phase extraction, Abridged. Unpublished. Prepared under NIOSH Contract 200-2001-0800.
[5] Martyny JW, Arbuckle SL, McCammon CS Jr., Esswein EJ, Erb N [2003]. Chemical exposures associated with clandestine methamphetamine laboratories [https://www.nationaljewish.org/NJH/media/pdf/ pdf-EnvOccChemical_Exposures.pdf]. Date accessed April 2014.
[6] NIOSH [2011]. Methamphetamine and illicit drugs, precursors, and adulterants on wipes by liquidliquid extraction: Method 9106. In: Ashley KA, O’Connor PF, eds. NIOSH manual of analytical methods. 5th ed. Cincinnati, OH: U.S. Department of Health and Human Services, Centers for Disease Control and
[7] NIOSH [2011]. Methamphetamine on wipes by liquid chromatography/mass spectrometry: Method 9111. In: Ashley KA, O’Connor PF, eds. NIOSH manual of analytical methods. 5th ed. Cincinnati, OH: U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, [www.cdc.gov/niosh/nmam/].
[8] Baum RM [1985]. New variety of street drugs poses growing problem. Chemical and Engineering
[9] Buchanan JF, Brown CR [1988]. Designer drugs, a problem in clinical toxicology. Medical Toxicology 3:1-17.
[10] NIOSH [1994]. Chapter C: Quality Assurance. In: Eller PM, Cassinelli ME, eds. NIOSH manual of analytical methods, 4th ed. Cincinnati, OH: Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, DHHS (NIOSH) Publication No. 94-113. [www.cdc.gov/niosh/nmam/].
[11] NIOSH [1995]. NIOSH Technical Report: Guidelines for air sampling and analytical method development and evaluation. By Kennedy ER, Fischbach TJ, Song R, Eller PM, Shulman SA.
[12] Burkart JA [1986]. General procedures for limit of detection calculations in the industrial hygiene chemistry laboratory. Applied Industrial Hygiene 1(3):153-155.
METHAMPHETAMINE . . . on Wipes by SPE: METHOD 9109, Issue 1, dated 17 October 2011 - Page 9 of 32
[13] Van Dyke MV, Serrano KA, Kofford S, Contreras J, Martyny JW [2011]. Variability and specificity associated with environmental methamphetamine sampling and analysis. J Occup Environ Hyg 8(11):636-4. Date accessed May, 2011.
[14] Little JL [1999]. Artifacts in trimethylsilyl derivatization reactions and ways to avoid them. Journal of Chromatography. A, 844:1-22.
[15] Crockett DK, Frank EL, and Roberts WL [2002]. Rapid analysis of metanephrine and normetanephrine in urine by gas chromatography-mass spectrometry. Clinical Chemistry 48: 332-337.
[16] Serrano KA, Martyny JW, Kofford S, Contreras JR, Van Dyke MV [2012]. Decontamination of clothing and building materials associated with the clandestine production of methamphetamine. J Occup Environ Hyg 9(3):185-197.
[17] Budavari S, ed. [1989]. Merck Index, 11th ed. Rahway, New Jersey: Merck and Co.
[18] Sweet DV, ed. [1997]. Registry of toxic effects of chemical substances. DHHS (NIOSH) Publication No. 97-119. [https://www.cdc.gov/niosh/].
[19] Sigma-Aldrich MSDS sheets [http://www.sigma-aldrich.com]. Date accessed: May 10, 2004.
[21] Howard PH, Meylan WM [1997]. Handbook of physical properties of organic chemicals. Boca Raton, Florida: CRC/Lewis Publishers. See also Syracuse Research Corporation’s website [http://www.srcinc. com for demos and updates. Date accessed May 10, 2004.
[23] Cui JF, Zhou TH, Zhang JS, and Lou ZC [1991]. Analysis of alkaloids in chinese ephedra species by gas chromatographic methods. Phytochemical Analysis 2:116-119.
Division, OSHA Salt Lake Technical Center, Salt Lake City, Utah. [http://www.osha.gov/dts/sltc/ methods/surfacesampling/surfacesampling.pdf ]. Date accessed May 2011.
METHAMPHETAMINE . . . on Wipes by SPE: METHOD 9109, Issue 1, dated 17 October 2011 - Page 10 of 32 Table 1. Formula and registry numbers of analytes
Dion C, Perrault G [2005]. Summary of good cleanup and decontamination practices for workplaces with beryllium-containing dust (Publ. no. R-409). Montreal, Canada: IRSST.
BERYLLIUM in Surface Wipes by Fluorometry: METHOD 9110, Issue 2, 12 December 2015- Page 7 of 8
NIOSH [1994]. Elements by ICP (nitric/perchloric acid ashing): Method 7300 (supplement issued 3/15/03). In: NIOSH Manual of Analytical Methods. 4th ed. Cincinnati, OH: National Institute for Occupational Safety and Health, DHHS (NIOSH) Publication No. 94–113.
ASTM International [2015]. D7202 – Standard test method for determination of beryllium in the workplace using field-based extraction and fluorescence detection. West Conshohocken, PA: ASTM International.
Ashley K, Wise TJ, Marlow D, Agrawal A, Cronin JP, Adams L, Ashley E, Lee PA [2011]. Trace beryllium determination in polyvinyl alcohol wipes by extraction and fluorescence detection – Interlaboratory analysis. Anal Methods 3: 1906-1901.
ASTM International [2013]. D6966 - Standard practice for wipe sampling of surfaces for subsequent determination of metals. West Conshohocken, PA: ASTM International.
ASTM International [2011]. D7707 - Standard Specification for Wipe Sampling Materials for Beryllium in Surface Dust. West Conshohocken, PA: ASTM International. [10]
Goldcamp MJ, Goldcamp DM, Ashley K, Fernback JE, Agrawal A, Millson M, Marlow D,Harrison K [2009]. Extraction of beryllium from refractory beryllium oxide with dilute ammonium bifluoride and determination by fluorescence – A multi-parameter performance evaluation. J Occup Environ Hyg 6: 735-744. [11]
McCleskey TM, Agrawal A, Ashley K [2007]. Backup data—method nos. 7704 and 9110 / beryllium, Issue 1. NIOSH Docket Office, Cincinnati, Ohio 45226; e-mail: NIOSHDocket@cdc.gov. [12]
Youmans-McDonald L, Brisson MJ, Bernard M, Agrawal A, Cronin J, Adams, L [2011]. Determining beryllium by optical fluorescence using pre-wetted wipes. J ASTM Int 8(3) [JAI 103489]. [13]
Agrawal A, Adams LL, Agrawal A, Cronin JP, Tonazzi JCL, Duran BL [2011]. Beryllium measurement by optical fluorescence in samples contaminated by fluorescent impurities, J ASTM Int 8(8) [JAI 103411]. [14]
Ashley K, McCleskey TM, Brisson MJ, Goodyear G, Cronin J, Agrawal A [2005]. Interlaboratory evaluation of a portable fluorescence method for the measurement of trace beryllium in the workplace. J
[15] Kennedy ER, Fischbach TJ, Song R, Eller PM, Shulman SA [1995]. Guidelines for air sampling and analytical method development and evaluation. Cincinnati, OH: National Institute for Occupational Safety and Health; DHHS (NIOSH) Publication No. 95–117
BERYLLIUM in Surface Wipes by Fluorometry: METHOD 9110, Issue 2, 12 December 2015- Page 8 of 8
NIOSH: None for surfaces Other OELs and guidelines: [1, 2, 3] 9111 Issue 1: 17 October 2011
[2] Institut fur Arbeitsschutz der Deutschen Gesetzlichen Unfallversicherung [2013]. GESTIS database on hazardous substances (German Social Accident Insurance). Sankt Augustin, FRG: [http://www.dguv.de/ ifa/GESTIS]. Data accessed April 2014.
[3] EPA [2013]. Voluntary guidelines for methamphetamine laboratory cleanup. [https://www.epa.gov/sites/ production/files/documents/meth_lab_guidelines.pdf ]. Date accessed March 2016.
[4] Siso MC, McKay TT, Reynolds JM, Wickman DC [2005]. Backup data report for NIOSH 9111, Methamphetamine on wipes by liquid chromatography-mass spectrometry. Unpublished. Prepared under NIOSH Contract 200-2001-0800.
[5] NIOSH [2011]. Methamphetamine and illicit drugs, precursors, and adulterants on wipes by liquid-liquid extraction: Method 9106. In: Ashley KA, O’Connor PF, eds. NIOSH manual of analytical methods. 5th ed. Cincinnati, OH: U.S. Department of Health and Human Services, Centers for Disease Control and
[6] NIOSH [2011]. Methamphetamine and illicit drugs, precursors, and adulterants on wipes by solid phase extraction: Method 9109. In: Ashley KA, O’Connor PF, eds. NIOSH manual of analytical methods. 5th ed. Cincinnati, OH: U.S. Department of Health and Human Services, Centers for Disease Control and
[7] Burkart JA [1986]. General procedures for limit of detection calculations in the industrial hygiene chemistry laboratory. Appl Ind Hyg 1(3):153-155.
[8] NIOSH [1995]. NIOSH Technical Report: Guidelines for air sampling and analytical method development and evaluation. By Kennedy ER, Fischbach TJ, Song R, Eller PM, Shulman SA. Cincinnati, OH: U.S. Department of Health and Human Services, Public Health Services, Centers for Disease Control and
[9] Serrano KA, Martyny JW, Kofford S, Contreras JR, Van Dyke MV [2012]. Decontamination of clothing and building materials associated with the clandestine production of methamphetamine. J Occup Environ Hyg 9(3):185-197.
[10] Van Dyke MV, Serrano KA, Kofford S, Contreras J, Martyny JW [2011]. Variability and specificity associated with environemental methamphetamine sampling and analysis. J Occup Environ Hyg 8(11):636-41.
METHOD DEVELOPMENT BY: Maria Carolina Siso, Thomas T. McKay, John M. Reynolds, and Don C. Wickman, DataChem Laboratories, Inc., Salt Lake City, Utah under NIOSH Contract CDC 200-2001-0800.
METHAMPHETAMINE on Wipes by LC/MS : METHOD 9111, Issue 1, dated 17 October 2011 - Page 7 of 10 Disclaimer: Mention of any company or product does not constitute endorsement by NIOSH. In addition, citations to websites external to NIOSH do not constitute NIOSH endorsement of the sponsoring organizations or their programs or products. Furthermore, NIOSH is not responsible for the content of these websites. All web addresses referenced in this document were accessible as of the publication date. Table 1. Suggested Mass Spectrometer SIM Conditions Ionization Mode: Polarity: Fragmentator:
METHAMPHETAMINE on Wipes by LC/MS : METHOD 9111, Issue 1, dated 17 October 2011 - Page 8 of 10 Table 2. Suggested spiking schedule for calibration standards Volume (µL) of Methamphetamine Spiking Solution Spiked on Media Standard 200 µg/mL solution 20 µg/mL solution Internal Standard Spike (µL) Desorption Solution (mL) Final Concentration (µg/
ASTM Int 2(4):1-13, DOI: 10.1520/JAI12231.