NIOSH Manual of Analytical Methods (NMAM), 5th Edition, Section 2
Other documents for the same rulemaking (all, by stage)
References: 1,700 extracted, 0 linked to papers
[1] ACGIH [2013]. TLVs and BEIs based on the documentation of the Threshold Limit Values for chemical substances and physical agents and Biological Exposure Indices. Cincinnati, Ohio: American Conference of Governmental Industrial Hygienists. [www.acgih.org]. Date accessed: April 2014.
[5] Boogaard PJ, Van Sittert NJ [1995]. Biological monitoring of exposure to benzene: A comparison between S-phenylmercapturic acid, trans, trans-muconic acid and phenol. Occup Environ Med 52:611-620.
[6] Schettgen T, Musiol A, Kraus T [2008]. Fast determination of urinary S-phenylmercapturic acid and S-benzylmercapturic acid by column-switching liquid chromatography-mass spectrometry. J Chromatogr B 863:283-292.
[7] FDA [2001]. Guidance for industry: Bioanalytical method validation, U.S. Food and Drug
Administration, Rockville, MD. [http://www.fda.gov/downloads/Drugs/Guidances/ucm070107.pdf ]. Date accessed April 2014.
Bartolucci GB, Violante FS, Soleo L [2010]. Validity of new biomarkers of internal dose for use in the biological monitoring of occupational and environmental exposure to low concentrations of benzene and toluene. Int Arch Occup Environ Health 83:341-356.
[9] B’Hymer C [2011]. Backup data report for method no. 8326: S-benzylmercapturic acid and S-phenylmercapturic acid in urine.
[10] B’Hymer C [2011]. Validation of an HPLC-MS/MS method for the determination of urinary S-benzylmercapturic acid and S-phenylmercapturic acid. J Chromatogr Sci 49:547-553.
[11] Alwis KU, Blount BC, Britt AS, Patel D, Ashley DL [2012]. Simultaneous analysis of 28 urinary VOC metabolites using ultra high performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry (UPLC-ESI/MS-MS). Anal Chim Acta 750:152-160.
[12] CDC [2007]. 2007 Guidelines for isolation precautions: Preventing transmission of infectious agents in healthcare settings. [http://www.cdc.gov/hicpac/2007IP/2007isolationprecautions.html]. Date accessed: April 2014.
NIOSH Manual of Analytical Methods (NMAM), Fifth Edition S-Benzylmercapturic acid and S-phenylmercapturic acid in urine: METHOD 8326, Issue 1, dated 20 May 2014 - Page 7 of 10
NIOSH Manual of Analytical Methods (NMAM), Fifth Edition S-Benzylmercapturic acid and S-phenylmercapturic acid in urine: METHOD 8326, Issue 1, dated 20 May 2014 - Page 8 of 10 Figure 1. Chromatograms obtained using the described procedure: (A) fortified urine containing 1 ng/mL S-PMA, 7.2 ng/mL S-BMA, and 3.8 ng/mL of each of the deuterated internal standards (IS) and (B) non-fortified urine from above containing only the background level of 6.2 ng/mL S-BMA
NIOSH Manual of Analytical Methods (NMAM), Fifth Edition S-Benzylmercapturic acid and S-phenylmercapturic acid in urine: METHOD 8326, Issue 1, dated 20 May 2014 - Page 9 of 10 Table 2. Multiple level recovery experiment of BMA and PMA from urine Analyte BMA2 Analyte added (ng/mL) Mean background Mean corrected concentration concentration (ng/mL, n = 9) (ng/mL, n = 9) 7.43 7.18 Standard Average deviation recovery (%) (ng/mL) 0.37 %RSD1 BMA2 8.44 8.18 0.19 14.6 14.2 0.32
[1] Lange BA, Haartz JC [1979]. Determination of microgram quantities of asbestos by x-ray diffraction: chrysotile in thin dust layers of matrix material. Anal Chem 51(4):520–525.
[2] NIOSH [1979]. Chrysotile asbestos (bulk): P&CAM 309. In: Taylor DG, ed. NIOSH manual of analytical methods. 2nd ed. Vol. 5. Cincinnati, OH: U.S. Department of Health, Education, and Welfare, Center for Disease Control, National Institute for Occupational Safety and Health, DHEW (NIOSH) Publication No. 79-141, available as accession No. PB83-105445 from NTIS [www.ntis.gov].
[3] Perkins RL, Harvey BW [1993]. Test method: method for the determination of asbestos in bulk building material. Washington, DC: US Environmental Protection Agency, Office of Research and
[4] NIOSH [1976]. Revised recommended asbestos standard. Cincinnati, OH: U.S. Department of Health,
[5] Leroux J, Powers CA [1970]. Direct x-ray diffraction quantitative analysis of quartz in industrial dust films deposited on silver membrane filters. Occup Health Rev 21(1):26–34.
[6] Williams PP [1959]. Direct quantitative diffractometric analysis. Anal Chem 31(11):1842–1844.
[7] Abell MT, Dollberg DD, Lange BA, Hornung RW, Haartz JC [1981]. Absorption corrections in x-ray diffraction dust analyses: procedures employing silver filters. In: Russell PA, ed. Electron microscopy and x-ray applications to environmental and occupational health analysis. Vol. 2. Ann Arbor, MI: Ann Arbor Science Publishers, Inc., pp. 115–118.
[8] Dollberg DD, Abell MT, Lange BA [1980]. Occupational health analytical chemistry: quantitation using x-ray powder diffraction. In: Dollberg DD, Verstuyft AW, eds. Analytical techniques in occupational health chemistry. Washington, DC: American Chemical Society, ACS Symposium Series No. 120, pp. 43–65.
ASBESTON, CHRYSOTILE by XRD: METHOD 9000, Issue 3, dated 20 October 2015 - Page 6 of 7
ASBESTON, CHRYSOTILE by XRD: METHOD 9000, Issue 3, dated 20 October 2015 - Page 7 of 7 Table 1a. Absorption correction factor as a function of transmittance (1.00 to 0.70) for chrysotile primary and secondary peak combinations with silver primary peak Table 1b. Absorption correction factor as a function of transmittance (0.69 to 0.39) for chrysotile primary and secondary peak combinations with silver primary peak Absorption Correction Factor Transmittance Primary Peak Secondary Peak 1.00 0.99 0.98 0.97 0.96 0.95 0.94 0.93 0.92 0.91 0.90 0.89 0.88 0.87 0.86 0.85 0.84 0.83 0.82 0.81 0.80 0.79 0.78 0.77 0.76 0.75 0.74 0.73 0.72 0.71 0.70 1.0000 1.0157 1.0317 1.0480 1.0647
[2] Institut fur Arbeitsschutz der Deutschen Gesetzlichen Unfallversicherung [2013]. GESTIS database on hazardous substances (German Social Accident Insurance). Sankt Augustin, FRG: [http://www. dguv.de/ifa/GESTIS ]. Data accessed April 2014.
[3] EPA [2013]. Voluntary guidelines for methamphetamine laboratory cleanup. [https://www.epa.gov/ sites/production/files/documents/meth_lab_guidelines.pdf ]. Date accessed March 2016.
[4] Reynolds JM, Siso MC, Perkins JB [2004]. Backup data report for NIOSH 9106, Methamphetamine and illicit drugs, precursors, and adulterants on wipes by liquid-liquid extraction, Abridged, prepared under NIOSH Contract 200-2001-0800, Unpublished.
[5] Martyny JW, Arbuckle SL, McCammon CS Jr., Esswein EJ, Erb N [2003]. Chemical exposures associated with clandestine methamphetamine laboratories. [https://www.env.nm.gov/cdli/docs/ Chemical_Exposures.pdf ].
[6] NIOSH [2011]. Methamphetamine and illicit drugs, precursors, and adulterants on wipes by solid phase extraction: Method 9109. In: Ashley KA, O’Connor PF, eds. NIOSH manual of analytical methods. 5th ed. Cincinnati, OH: U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, [www.cdc. gov/niosh/nmam/].
[7] NIOSH [2011]. Methamphetamine on Wipes by Liquid Chromatography/Mass Spectrometry: Method 9111. In: Ashley KA, O’Connor PF, eds. NIOSH manual of analytical methods. 5th ed.
METHAMPHETAMINE . . .on Wipes by Liquid-Liquid Extraction: METHOD 9106, Issue 1, dated 17 October 2011 - Page 9 of 30
[8] ASTM International [2015]. ASTM-E982-94(2015), Standard specification for laboratory glass test tubes. West Conshohocken, PA: ASTM International.
[9] Baum RM [1985]. New variety of street drugs poses growing problem. Chemical and Engineering
[10] Buchanan JF, Brown CR [1988]. Designer drugs, a problem in clinical toxicology. Medical Toxicology 3:1-17.
[11] NIOSH [1994]. Chapter C: Quality Assurance. In: Eller PM, Cassinelli ME, eds. NIOSH Manual of Analytical Methods, 4th ed. Cincinnati, OH: Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, DHHS (NIOSH) Publication No. 94-113. [www.cdc.gov/niosh/nmam/].
[12] Burkart JA [1986]. General procedures for limit of detection calculations in the industrial hygiene chemistry laboratory. Appl Ind Hygiene 1(3):153-155.
[13] Reynolds JM, Siso MC, Perkins JB [2004]. Backup data report for NIOSH 9109, Methamphetamine and illicit drugs, precursors, and adulterants on wipes by solid phase extraction. Unpublished. Prepared under NIOSH Contract 200-2001-0800.
[14] Budavari S, ed. [1989]. Merck Index, 11th ed. Rahway, NJ: Merck and Co., Inc.
[15] Serrano KA, Martyny JW, Kofford S, Contreras JR, Van Dyke MV [2012]. Decontamination of clothing and building materials associated with the clandestine production of methamphetamine. J Occup Environ Hyg 9(3):185-197.
[16] Van Dyke MV, Serrano KA, Kofford S, Contreras J, Martyny JW [2011]. Variability and specificity associated with environmental methamphetamine sampling and analysis. J Occup Environ Hyg 8(11):636-41.
[17] Sweet DV, ed. [1997]. Registry of toxic effects of chemical substances. DHHS (NIOSH) Publ. No. 97-119. https://www.cdc.gov/niosh/.
[18] Sigma-Aldrich MSDS sheets, http://www.sigma-aldrich.com [May 10, 2004].
[20] The National Alliance for Model State Drug Laws (NAMSDL) [2007]. State Controlled Substance(s) Environmental Issues Bill – Status Update [http://www.namsdl.org/]. Date accessed: March 11, 2008.
[21] Howard PH, Meylan WM [1997]. Handbook of physical properties of organic chemicals. Boca Raton, Florida: CRC/Lewis Publishers. See also Syracuse Research Corporation’s website http://www.srcinc. com/ (May 10, 2004) for demos and updates.
[22] Zhang JS, Tian Z, Lou ZC [1989]. Quality evaluation of twelve species of chinese ephedra (Ma Huang). Acta Pharmaceutic Sinica 24(11):865-871.
[23] Cui JF, Zhou TH, Zhang JS, and Lou ZC. [1991]. Analysis of alkaloids in chinese ephedra species by gas chromatographic methods. Phytochemical Analysis 2:116-119.
[24] Andrews KM [1995]. Ephedra’s role as a precursor in the clandestine manufacture of methamphetamine. Journal of Forensic Sciences 40(4):551-560.
[25] OSHA [2001]. Evaluation guidelines for surface sampling methods. Industrial Hygiene Chemistry
Division, OSHA Salt Lake Technical Center, Salt Lake City, Utah. [http://www.osha.gov/dts/sltc/ methods/surfacesampling/surfacesampling.pdf ] Date accessed: May 2011.
METHOD DEVELOPMENT BY: John M. Reynolds, Maria Carolina Siso, and James B. Perkins, DataChem Laboratories, Inc., Salt Lake City, Utah under NIOSH Contract CDC 200-2001-0800. Disclaimer: Mention of any company or product does not constitute endorsement by NIOSH. In addition, citations to websites external to NIOSH do not constitute NIOSH endorsement of the sponsoring organizations or their programs or products. Furthermore, NIOSH is not responsible for the content of these websites. All web addresses referenced in this document were accessible as of the publication date.
METHAMPHETAMINE . . .on Wipes by Liquid-Liquid Extraction: METHOD 9106, Issue 1, dated 17 October 2011 - Page 10 of 30 Table 1. Formula and registry numbers of analytes.