NIOSH: 5 mg/m³, C 15 mg/m³ (15 min) (dust); 5 mg/m³, STEL 10 mg/m³ (fume) Issue 1: 15 February 1984 Issue 3: 20 October 2015
PROPERTIES: Solid; d 5.61 g/cm³ @ 25 °C; MP 1975 °C
BLANKS: 2 to 10 field blanks per set RANGE: 50 µg to 2000 µg per sample
[1] NIOSH [1977]. Zinc oxide in air: P&CAM 222. In: Taylor DG, ed. NIOSH manual of analytical methods. 2nd ed. Vol. 1. Cincinnati, OH: U.S. Department of Health, Education, and Welfare, Center for Disease
[2] NIOSH [1977]. Backup data report: zinc oxide fume, No. S316. In: Ten NIOSH analytical methods, set 3. Cincinnati, OH: U.S. Department of Health, Education, and Welfare, Center for Disease Control, National Institute for Occupational Safety and Health, available as accession No. PB275834 from
[3] Haartz JC, Bolyard ML, Abell MT [1975]. Quantitation of zinc chloride and zinc oxide in airborne samples. Unpublished paper presented at the American Industrial Hygiene Conference,
[4] Dollberg DD, Abell MT, Lange BA [1980]. Occupational health analytical chemistry: quantitation using x-ray powder diffraction. In: Dollberg DD, Verstuyft AW, eds. Analytical techniques in
ZINC OXIDE: METHOD 7502, Issue 3, dated 20 October 2015 - Page 5 of 5 occupational health chemistry. Washington, DC: American Chemical Society, ACS Symposium Series No. 120, pp. 43–65.
[5] NIOSH [1978]. Zinc oxide fume: Method S316. In: Taylor DG, ed. NIOSH manual of analytical methods. 2nd ed. Vol. 4. Cincinnati, OH: U.S. Department of Health, Education, and Welfare, Center for Disease Control, National Institute for Occupational Safety and Health, DHEW (NIOSH) Publication No. 78-175, available as accession No. PB83-105437 from NTIS [www.ntis.gov].
[6] NIOSH [1975]. Criteria for a recommended standard: occupational exposure to zinc oxide.
Cincinnati, OH: U.S. Department of Health, Education, and Welfare, Center for Disease Control, National Institute for Occupational Safety and Health, DHEW (NIOSH) Publication No. 76-104 [www. cdc.gov/niosh/docs/1970/76-104.html].
[7] Altree-Williams S, Lee J, Mezin NV [1977]. Quantitative x-ray diffractometry on respirable dust collected on Nuclepore filters. Ann Occup Hyg 20(2):109–126.
[8] Leroux J, Powers CA [1970]. Direct x-ray diffraction quantitative analysis of quartz in industrial dust films deposited on silver membrane filters. Occup Health Rev 21(1):26–34.
[9] Williams PP [1959]. Direct quantitative diffractometric analysis. Anal Chem 31(11):1842–1844.
[10] NIOSH [1980]. Development and validation of methods for sampling and analysis of workplace toxic substances. By Gunderson EC, Anderson CC, Smith RH, Doemeny LJ. Cincinnati, OH: U.S. Department of Health and Human Services, Centers for Disease Control, National Institute for Occupational Safety and Health, DHHS (NIOSH) Publication No. 80-133, available as accession No. PB89-182042 from NTIS [www.ntis.gov].
[1] NIOSH [1977]. Chromic acid mist in air: P&CAM 169. In: Taylor DG, ed. NIOSH manual of analytical methods. 2nd ed. Vol. 1. Cincinnati, OH: U.S. Department of Health, Education, and Welfare, Center for Disease Control, National Institute for Occupational Safety and Health, DHEW (NIOSH) Publication No. 77-157-A, available as accession No. PB274845 from NTIS [www.ntis.gov].
[2] NIOSH [1977]. Chromic acid and chromates: Method S317. In: Taylor DG, ed. NIOSH manual of analytical methods. 2nd ed. Vol. 3. Cincinnati, OH: U.S. Department of Health, Education, and
[3] NIOSH [1980]. Hexavalent chromium: P&CAM 319. In: Taylor DG, ed. NIOSH manual of analytical methods. 2nd ed. Vol. 6. Cincinnati, OH: U.S. Department of Health and Human Services, Centers for Disease Control, National Institute for Occupational Safety and Health,, DHHS (NIOSH) Publication No. 80-125, available as accession No. PB82-157728 from NTIS [www.ntis.gov].
CHROMIUM, HEXAVALENT: METHOD 7600, Issue 3, dated 20 October 2015 - Page 5 of 5
[4] NIOSH [2013]. Criteria for a recommended standard: occupational exposure to hexavalent chromium. Cincinnati, OH: U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, DHHS (NIOSH)
Publication No. 2013-128 [www.cdc.gov/niosh/docs/2013-128/].
[5] NIOSH [1977]. Backup data report: chromic acid and chromates, No. S317. By Taylor DG, Kupel
[6] Abell MT, Carlberg JR [1974]. A simple reliable method for the determination of airborne hexavalent chromium. Am Ind Hyg Assoc J 35(4):229–233.
Harper M, Sarkisian K, Andrew M [2014]. Assessment of respirable crystalline silica using Proficiency Analytical Testing results from 2003-2013. J Occup Environ Hyg 11:D157-D163.
NIOSH [2016]. Development and evaluation of methods (Chapter ME). By Kennedy ER, Fischbach TJ,
Cincinnati, OH: U.S. Department of Health and Human Services, Centers for Disease Control, National Institute for Occupational Safety and Health, DHHS (NIOSH) Publication No. 2014-151. Ojima J [2003]. Determining crystalline silica in respirable samples by infrared spectrophotometry in the presence of interferences. J Occup Health 45:94-103.
NIOSH [1977]. Method P&CAM 100 - Quartz in coal dust by infrared spectroscopy. In: Taylor DG, ed.
DHEW (NIOSH) Publication No. 77-157. Larsen DJ, von Loenhoff LJ, Crable JV [1972]. The quantitative determination of quartz in coal dust by infrared spectroscopy. Am Ind Hyg Assoc J 33:367-372.
Dodgson J, Whittaker W [1973]. The determination of quartz in respirable dust samples by infrared spectrophotometry – 1: The potassium bromide disc method. Ann Occup Hyg 16:373-387.
Cares JW, Goldin AS, Lynch JJ, Burgess WA [1973]. The determination of quartz in airborne respirable granite dust by infrared spectrophotometry. Am Ind Hyg Assoc J 34:298-305. [10]
Taylor DG, Nenadic CM, Crable JV [1970]. Infrared spectra for mineral identification. Am Ind Hyg Assoc J 31:100-108.
[11] Talvitie NA [1951]. Determination of quartz in the presence of silicates using phosphoric acid. Anal Chem 23:623-626.
RESPIRABLE CRYSTALLINE SILICA BY IR (KBr Pellet): METHOD 7602, Issue 4, dated 25 July 2017 - Page 6 of 7 [12]
NIOSH [2003]. Determination of airborne respirable silica (Chapter R). By Key-Schwartz RJ, Baron PA,
NIOSH [2003]. Methods 7603 and 7500. In: NIOSH manual of analytical methods, 4th ed.; Schlecht PC,
ASTM International [2014]. ASTM D7948, Standard test method for measurement of respirable crystalline silica in workplace air by infrared spectrometry. West Conshohocken, PA: ASTM International. [15]
Commerce, National Institute of Standards and Technology, https://www.nist.gov. Date accessed: July 25, 2017. Technology (NIST), Standard Reference Materials (SRMs); www.nist.gov (Accessed August 2016). [16]
Stacey P, Mecchia M, Verpaele S, Pretorius C, Key-Schwartz R, Mattenklott M [2014]. Differences between samplers for respirable dust and the analysis of quartz – An international study. In: Silica and Associated Respirable Mineral Particles (ASTM STP 1565); Harper M, Lee T, Eds. W.
Lee T, Lee EG, Kim SW, Chisholm W, Kashon M, Harper M [2012]. Quartz measurement in coal dust with high-flow rate samplers – Laboratory study. Ann Occup Hyg 56:413-425. [18]
ISO [1995]. Air quality – Particle size fraction definitions for health-related sampling. Geneva, Switzerland: International Organization for Standardization. [19]
Verpaele S, Jouret J [2013]. A comparison of the performance of samplers for respirable dust in workplaces and laboratory analysis for respirable quartz. Ann Occup Hyg 57:54–62. [20]
Stacey P, Kauffer EM, Moulut J-C, Dion C, Beauparlant M, Fernandez P, Key-Schwartz RJ, Friede B, Wake D [2009]. An international comparison of the crystallinity of calibration materials for the analysis of respirable α-quartz using x-ray diffraction and a comparison with results from the infrared KBr disc method. Ann Occup Hyg 53:639-649. [21]
Lee T, Chisholm WP, Kashon M, Key-Schwartz RJ, Harper M [2013]. Consideration of kaolinite interference correction for quartz measurements in coal mine dust. J Occup Environ Hyg 10:425-434.
[22] Bandyopadhyay AK [2010]. Determination of quartz content for Indian coals using an FTIR technique. Int J Coal Geol 81:73-87. [23]
Virji MV, Bello D, Woskie SR, Liu XM, Kalil AJ [2002]. Analysis of quartz by FTIR in air samples of construction Appl Occup Environ Hyg 17:165-175. [24]
Verma DK, Sebestyen A, Julian JA, Muir DCF [1992]. A comparison of two methods of sampling and analysis for free crystalline silica α-quartz. Appl Occup Environ Hyg 7:758-763. [25]
Shulman SA, Groff JH, Abell MT [1992]. Performance of laboratories measuring silica in the Proficiency Analytical Testing program. Am Ind Hyg Assoc J 53:49-56.
RESPIRABLE CRYSTALLINE SILICA BY IR (KBr Pellet): METHOD 7602, Issue 4, dated 25 July 2017 - Page 7 of 7 [26]
Stacey P, Tylee B, Bard D, Atkinson R [2003]. The performance of laboratories analyzing α-quartz in the Workplace Analysis Scheme for Proficiency. Ann Occup Hyg 47:269-277.
Farcas D, Lee T, Chisholm WP, Soo J-C, Harper M [2016]. Replacement of filters for respirable quartz measurement in coal mine dust by infrared spectroscopy. J Occup Environ Hyg 13:D17-D22. Anderson CC [1983]. Collaborative test of two methods for determining free silica in airborne dust.