Rooker SJ, Vaughn NP, LeGuen JM [1982]. On the visibility of fibers by phase contrast microscopy. Am Ind Hyg Assoc J 43:505–515.
Kenney LC, Rood AP, Blight BJN [1987]. A direct measurement of the visibility of amosite asbestos fibres by phase contrast optical microscope. Ann Occup Hyg 33:261–264.
ASBESTOS and OTHER FIBERS by PCM: METHOD 7400, Issue 3, dated 14 June 2019 - Page 17 of 40
Harper M, Lee EG, Doorn SS, Hammond O [2008]. Differentiating non-asbestiform amphibole and amphibole asbestos by size characteristics. J Occup Envir Hyg 5:761–770. [10]
Lee EG, Nelson J, Kashon M, Harper M [2015]. Evaluation of the dark-medium objective lens in counting asbestos fibers by phase-contrast microscopy. Ann Occup Hyg 59:616–628. [11]
Baron P, Deye G [1990]. Electrostatic effects in asbestos sampling: parts I and II. Am Ind Hyg Assoc J 51:51–69. [12]
ISO [2013]. ISO 13137-13 Workplace atmospheres -- Pumps for personal sampling of chemical and biological agents -- Requirements and test methods. Geneva, Switzerland: International Organization for Standardisation. [13]
Johnston AM, Jones AD, Vincent JH [1982]. The influence of external aerodynamic factors on the measurement of the airborne concentration of asbestos fibers by the membrane filter method. Ann Occup Hyg 25:309–316.
[14] Beckett ST [1980]. The effects of sampling practice on the measured concentration of airborne asbestos. Ann Occup Hyg 23:259–272. [15]
Cherrie J, Jones AD, Johnston AM [1986]. The influence of fiber density on the assessment of fiber concentration using the membrane filter method. Am Ind Hyg Assoc J 47(8):465–474. [16]
Lee EG, Nelson J, Hintz PJ, Joy G, Andrew ME, Harper M [2010]. Field performance of the CATHIA-T sampler and two cyclones against the standard cowled sampler for thoracic fiber concentrations. Ann Occup Hyg 54:545-556. [17]
NIOSH [1977]. P&CAM 239. In: Taylor DG, ed. NIOSH manual of analytical methods, 2nd ed. Cincinnati,
AIA [1979]. AIA Health and Safety Recommended Technical Method #1: airborne asbestos fiber concentrations at workplaces by light microscopy. London, England: Asbestos International Association. [19]
Crane D, Harper M [2011]. The phase-shift test slide. https://www2.aiha.org/Registries/aar/Documents/Phase%20Shift%20Interpretation%20OSHA% 20NIOSH_2011_04_11.pdf . [20]
Abell MS, Shulman SA, Baron P [1989]. The quality of fiber count data. Appl Ind Hyg 4:273–285. [21]
AIA [1983]. A study of the empirical precision of airborne asbestos concentration measurements in the workplace by the membrane filter method. Arlington, VA: Asbestos Information Association, Air Monitoring Committee. [22]
NIOSH [1976]. Revised Recommended Asbestos Standard. Cincinnati, OH: U.S. Department of Health,
IOM [1982]. A comparison of the effects of different counting rules and aspect ratios on the level and reproducibility of asbestos fiber counts. Part I: effects on level and Part II: effects on reproducibility. By Crawford NP, Thorpe HL, Alexander W. Edinburgh, Scotland: Institute of Occupational Medicine. [24]
HSE [1982]. Health and Safety Executive research paper 18: the reproducibility of fiber counts. By
ASBESTOS and OTHER FIBERS by PCM: METHOD 7400, Issue 3, dated 14 June 2019 - Page 18 of 40 [25]
Schlecht PC, Schulman SA [1986]. Performance of asbestos fiber counting laboratories in the NIOSH Proficiency Analytical Testing (PAT) Program. Am Ind Hyg Assoc J 47:259–266. [26]
Edwards GH, Lynch JR [1968]. The method used by the Public Health Service, for enumeration of asbestos dust on membrane filters. Ann Occup Hyg 11:1-6. [27]
Lane RE, Barnes JM, Roach SA, Smith S, Addingley CG, Holmes S, Hunt R, Knox JF, King E [1968]. Hygiene standard for chrysotile asbestos dust. Ann Occup Hyg 11:47 -49. [28]
NIOSH [1972]. NIOSH criteria for a recommended standard: occupational exposure to asbestos.
[30] Walton WH [1982]. The nature, hazards, and assessment of occupational exposure to airborne asbestos dust: a review. Ann Occup Hyg 25:115–247. [31]
LeGuen JMM, Ogden TL, Shenton-Taylor T [1984]. The phase-shift test slide. Ann Occup Hyg 28:237247. [32]
Taylor DG, Baron PA, Shulman SA, Carter JW [1984]. Identification and counting of asbestos fibers. Am Ind Hyg Assoc J 45:84–88. [33]
Pang TWS, Harper M [2008]. The quality of fiber counts using improved slides with relocatable fields. J Environ Monit 10:89-95. [34]
Harper M, Slaven JE, Pang TWS [2009]. Continued participation in an asbestos fiber counting proficiency test with relocatable grid slides. J Environ Monit 11:434-438. [35]
ISO [2014]. ISO 8672-14[E] Air quality — determination of the number concentration of airborne inorganic fibres by phase contrast optical microscopy — membrane filter method. Geneva, Switzerland: International Organization for Standardisation. [36]
[37] Pang TWS [2000]. Precision and accuracy of asbestos fiber counting by phase contrast microscopy. Am Ind Hyg Assoc J 61:529–538. [38]
Harper M, Bartolucci A [2003]. Preparation and examination of proposed consensus reference standards for fiber-counting. Am Ind Hyg Assoc J 64:283-287. [39]
WHO [1985]. Reference methods for measuring airborne man-made mineral fibers (MMMF). By: The
NIOSH [1977]. NIOSH criteria for a recommended standard: occupational exposure to fibrous glass.
ASBESTOS and OTHER FIBERS by PCM: METHOD 7400, Issue 3, dated 14 June 2019 - Page 19 of 40
ASBESTOS and OTHER FIBERS by PCM: METHOD 7400, Issue 3, dated 14 June 2019 - Page 20 of 40 with a permanent Euparal medium and covered with a relocatable gridded cover slip. The fibers visible in each grid opening have been identified and their locations marked on a drawing of each opening. The identity, number and position of each fiber have been verified by a second microscopist. The accuracy of this verification has been shown to be within 3% of consensus values determined by
Springfield, Illinois, 1958. 11.13. Clark, G. L., The Encyclopedia of Microscopy, Rheinhold Publishing Corporation, New York, 1961. 11.14. McCrone, W. C. and J. G. Delly, I. The Particle Atlas, Edition Two, Ann Arbor Science Publishers, Inc., Ann Arbor, Michigan, 1973.
ASBESTOS and OTHER FIBERS by PCM: METHOD 7400, Issue 3, dated 14 June 2019 - Page 37 of 40 Figure 1 Optimum Sampling Times for airborne asbestos where microscopic field area = 0.003 mm2
ASBESTOS and OTHER FIBERS by PCM: METHOD 7400, Issue 3, dated 14 June 2019 - Page 38 of 40 Figure 2 Optimum sampling times for airborne asbestos where microscopic field area = 0.006 mm2 Figure 3 Total coefficient of variation as a function of total fiber count
ASBESTOS and OTHER FIBERS by PCM: METHOD 7400, Issue 3, dated 14 June 2019 - Page 39 of 40 Figure 4 Nomogram of optimum sampling times for airborne asbestos fibers in concentrations of 1 to 10 fibers/cm3 Figure 5 DO NOT COUNT. Fiber crosses top and bottom sides. Figure 6 COUNT. One fiber.
ASBESTOS and OTHER FIBERS by PCM: METHOD 7400, Issue 3, dated 14 june 2019 - Page 40 of 40 Figure 7 COUNT. One-half fiber. Fiber crosses left side and one end lies within the count area. Figure 8 COUNT. One-half fiber. Fiber crosses bottom side and one end lies within count area. Figure 9 DO NOT COUNT. Fiber crosses two sides. Figure 10 DO NOT COUNT. Fiber crosses two sides (bottom left corner). COUNT. One-half fiber. Fiber crosses bottom side and one end lies within count area. COUNT. One fiber (top right corner).
OTHER OELs: Refs. [1,2] Issue 1: 20 March 2018
Breuer D, Heinrich B [2001]. Alkali metal hydroxides and alkaline earth hydroxides, Method no. 1 (lithium hydroxide, sodium hydroxide, potassium hydroxide, calcium hydroxide); in Air monitoring methods, Vol. 8 – The MAK Collection for Occupational Health and Safety. Weinheim, Germany: Wiley-VCH. International Organization for Standardization (ISO) [2013]. ISO 17091, Workplace air – Determination of lithium hydroxide, sodium hydroxide, potassium hydroxide and calcium dihydroxide – Method by measurement of corresponding cations by suppressed ion chromatography. Geneva: ISO.
ISO [1995]. ISO Guide 98, Guide to the expression of uncertainty in measurement. Geneva: ISO.
ALKALI METAL CATIONS: METHOD 7405, Issue 1, dated 20 March 2018 - Page 5 of 5 Breuer D [2009]. Hydroxides (LiOH, NaOH, KOH, Ca(OH)2), in BGIA working folder, Sheet no. 7683. Berlin: Erich-Schmidt Verlag.
NIOSH [1994]. Method 7401, Alkaline dusts. In Schlect PC, O’Connor PF, eds. NIOSH manual of analytical methods, 4th ed. Cincinnati, OH: U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, DHHS (NIOSH) Publication No. 94-113.
ASTM International [2010]. ASTM D4840, Standard guide for sampling chain of custody procedures. West Conshohocken, PA: ASTM International.
ISO [2016]. ISO 20581, Workplace air quality – General requirements for the performance of procedures for the measurement of chemical agents. Geneva: ISO.
[10] Comité Européen de Normalisacion (CEN) [2009]. EN 13890, Workplace exposure – Procedures for measuring metals and metalloids in airborne particles – Requirements and test methods. Brussels:
[11] NIOSH [1995]. Guidelines for air sampling and analytical method development and evaluation. By