020_Potlatchdeltic_mnsr_analysis
Other documents for the same rulemaking (all, by stage)
References: 64 extracted, 0 linked to papers
Country, May 8, 2014. See https://www.epa.gov/sites/production/files/201609/documents/bbnonhappteef_memo.pdf. See Option 2 for Boiler MACT CO emission limit applicable to existing stokers/sloped grate/others designed to burn wet biomass fuel. Measured CO emission rate of 0.641 lb/MMBtu is not employed because the source is not required to achieve the emission rate observed. See Bison Engineering, Inc. April 22, 2016 Boiler MACT Stack Test Report prepared for Potlatch Land and Lumber, LLC. Table 7 of the report documents February 25, 2016 testing of Hurst boiler while generating approximately 28,500 lb steam/hr. 0.641 lb CO/Mlb steam = [(28.0 lb/hr / 28.389 Mlb steam/hr) + (5.9 lb/hr / 27.844 Mlb steam/hr) + (21.2 lb/hr / 29.244 Mlb steam/hr)] / 3.
AP-42, September 2003. Table 1.6-4. Spidell and Associates. August 27, 2004 Source Test Report prepared for Potlatch Corporation. Table 2 of the report documents August 4, 2004 testing of Hurst boiler while generating approximately 31,500 lb steam/hr. 0.267 lb
NOX/Mlb steam = [(8.84 lb/hr / 30.990 Mlb steam/hr) + (7.02 lb/hr / 32.271 Mlb steam/hr) + (9.32 lb/hr / 31.113 Mlb steam/hr)] / 3. No NOX testing reported in 2016 Boiler MACT Stack Test Report. Page A-4 of A-74 Appendix A: Potential Emissions Inventory Boiler MACT PM emission limit applicable at all times unit is operating except startup and shutdown. See July 8, 2016 Notification of Compliance Status for Potlatch's selection of PM compliance option rather than total selected metals. For PM limit, see row 7.b of Table 2 to 40 CFR 63 subpart DDDDD. PM emissions are the "filterable" fraction quantified via EPA RM5. PM emissions do not include the "condensible" fraction. See EPA final rulemaking in the October 25, 2012 Federal Register, pages 65107-65119, at http://www.gpo.gov/fdsys/pkg/FR-2012-1025/pdf/2012-25978.pdf. The 0.033 lb/mlb steam PM EF derived from stack testing is not employed to determine
Engineering, Inc. April 22, 2016 Boiler MACT Stack Test Report prepared for Potlatch Land and Lumber, LLC. Table 7 of the report documents February 25, 2016 testing of Hurst boiler while generating approximately 28,500 lb steam/hr. 0.033 lb PM/Mlb steam = [(1.01 lb/hr / 28.389 Mlb steam/hr) + (0.81 lb/hr / 27.844 Mlb steam/hr) + (0.98 lb/hr / 29.244 Mlb steam/hr)] / 3. 0.054 10.8 Boiler MACT for filterable portion and AP-42's Table 1.6-1, September 2003 for condensible portion. Assume all PM is also PM10. 0.037 lb/MMBtu (filterable) + 0.017 lb/MMBtu (condensible) = 0.054 lb/MMBtu. Fine Particulate (PM2.5) 0.054 10.8 Boiler MACT for filterable portion and AP-42's Table 1.6-1, September 2003 for condensible portion. Assume all PM is also PM10. 0.037 lb/MMBtu (filterable) + 0.017 lb/MMBtu (condensible) = 0.054 lb/MMBtu. Sulfur Dioxide (SO2) 0.009 Volatile Organic Compounds (VOC) 0.0023 Sulfuric Acid Mist (H2SO4) 0.0043 Particulate (PM) 0.037 Inhalable Coarse Particulate (PM10) Greenhouse Gas Emissions (CO2 Equivalent) (lb/MMBtu) 0.033 (lb/mlb steam) Biomass fuel upper bound sulfur estimate of 0.026% by weight (dry) and 15% conversion to SO2. See derivation of 0.009 lb/MMBtu EF below. Travis Energy & Environment, Inc. December 18, 1994 Emission Test Report prepared for Potlatch Corp. Table 33b of the report documents November 16, 1994 testing of the Hurst boiler. The portions of the report provided to
EPA do not present the heat input or steam generating rates experienced during testing. We assume the heat input was approximately 49 MMBtu/hr during November 1994 testing as that was the rate calculated for the 2016 Boiler
MACT testing. The 2016 Boiler MACT Stack Test Report indicates that no VOC testing was performed at that time, and the VOC testing conducted on August 4, 2004 was determined to be invalid by Idaho DEQ. See derivation of 0.002 lb/MMBtu EF below. 8 percent of PM2.5 emissions, based on BART-recommended PM2.5 / sulfate speciation for hog fuel boilers. (tpy)
TOTAL 42,184 SO2 EF: 0.009 lb/MMBtu Basis: Maximum sulfur content of 0.026% by weight, dry basis was measured during March 2017 sampling event at the facility. Upper bound 15% conversion to SO2. See H. S. Oglesby & R.
Blosser (1980) Information on the Sulfur Content of Bark and its Contribution to SO2 Emissions when Burned as a Fuel, Journal of the Air Pollution Control Association, 30:7, 769-772, DOI:10.1080/00022470.1980.10465107. A 15% sulfur to SO2 conversion factor is a reasonable upper bound estimate given 10% conversion measured by Oglesby and Blosser based upon limited amount of data from a handful of species.
VOCC equals "0.0017 lb/MMBtu" from December 18, 1994 Emission Test Report. Method 25A 0.0017 lb/MMBtu = 0.082 lb/hr / 49 MMBtu/hr.
VOC (as weighted average VOC) 12.011 lb/MMBtu lb/lb-mol Factor to convert VOCC to VOC (as weighted average VOC) = 1.355 lb/lb-mol 3.975 0.0023 lb/MMBtu The first two columns of the following table are extracted from AP-42, September 2003. Table 1.6-3. The third and fourth columns were created based upon information widely available over the internet. The fifth and sixth columns illustrate calculations necessary to determine weighted-average molecular weight and weighted-average number of carbon atoms comprising VOC emissions resulting from wood residue combustion. Wood Residue Combustion Organic Compounds Acenaphthene Acenaphthylene Acetaldehyde Acetone Acetophenone Acrolein Anthracene Benzaldehyde Benzene Benzo(a)anthracene Benzo(a)pyrene Benzo(b)fluoranthene Benzo(e)pyrene Benzo(g,h,i)perylene Benzo(j,k)fluoranthene Benzo(k)fluoranthene Benzoic acid Bis(2-ethylhexyl)phthalate (DEHP) Bromomethane (Methyle bromide) 2-Butanone (MEK) Carbazole Carbon tetrachloride Chlorobenzene Chloroform Chloromethane (Methyl chloride) 2-Chloronaphthalene 2-Chlorophenol Chrysene Crotonaldehyde Decachlorobiphenyl Dibenzo(a,h)anthracene 1,2-Dibromoethene (lb/MMBtu)
EF Reference Description February & May/June 2013 emissions testing of Hemlock lumber drying at less than 180°F within a pilot-scale kiln at Chemco in
Ferndale, Washington. Testing was performed by Emission Technologies, Inc. on behalf of Sierra Pacific Industries and consisted of RM5 and 202. http://www.swcleanair.org/docs/Dry%20Kilns/SourceTests/2013-02-21%20Sierra%20Pacific%20-%20Chemco%20%20Ferndale%20-%20Dry%20Kiln%20PM%20Test%20Report.pdf & http://www.swcleanair.org/docs/Dry%20Kilns/SourceTests/2013-05-29%20Sierra%20Pacific%20-%20Mt%20Vernon%20%20Pilot%20Dry%20Kiln%20Filterable%20and%20Condensable%20PM%20Test%20Report.pdf
EPA Region 10 HAP and VOC Emission Factors for Lumber Drying, December 2012. https://www.epa.gov/sites/production/files/201609/documents/ldkhapvocpteef_memo.pdf PotlatchDeltic St. Maries Complex, Technical Support Document
EPA Region 10 Non-HAP Potential to Emit Emission Factors for Biomass Boilers Located in Pacific Northwest Indian Country, May 8, 2014. CO Option 2 for Boiler MACT CO emission limit applicable to existing fuel cell units designed to burn biomass/bio-based solid fuel. See https://www.epa.gov/sites/production/files/2016-09/documents/bbnonhappteef_memo.pdf Boiler MACT
CO emission limit of 1100 ppmdv @ 3% O2 equivalent to 0.914 lb/MMBtu for biomass combusted during February 2016 Boiler MACT testing in which Fd = 9791 dscf/MMBtu. There is only a 3-run average compliance option; there is no 30-day rolling average available. Row 12.a of Table 2 to 40 CFR 63 subpart DDDDD. Boiler MACT emission limit applicable at all times unit is operating except startup and shutdown. Measured CO emission rate of 0.635 lb/Mlb steam is not employed because the source is not required to achieve the emission rate observed. See Bison Engineering, Inc. April 22, 2016 Boiler
MACT Stack Test Report prepared for Potlatch Land and Lumber, LLC. Table 5 of the report documents February 24, 2016 testing of CE boiler while generating approximately 34,300 lb steam/hr. 0.635 lb
EPA Region 10 Non-HAP Potential to Emit Emission Factors for Biomass Boilers Located in Pacific Northwest Indian Country, May 8, 2014. Pb Option 1 as no emission limits apply. See https://www.epa.gov/sites/production/files/2016-09/documents/bbnonhappteef_memo.pdf 54.7 Horizon Engineering. Project No. 3020 Source Evaluation Report prepared for Potlatch Forest Products Corporation. Table 2 of the report documents April 30, 2008 testing of CE boiler while generating approximately 23,700 lb steam/hr. No NOX testing reported in 2016 Boiler MACT Stack Test Report.
EPA Region 10 Non-HAP Potential to Emit Emission Factors for Biomass Boilers Located in Pacific Northwest Indian Country, May 8, 2014. PM Option 4 for Boiler MACT PM emission limit applicable to existing fuel cell units designed to burn biomass/bio-based solid fuel. See https://www.epa.gov/sites/production/files/2016-09/documents/bbnonhappteef_memo.pdf Boiler MACT
PM emission limit applicable at all times unit is operating except startup and shutdown. See July 8, 2016 Notification of Compliance Status for Potlatch's selection of PM compliance option rather than total selected metals. For PM limit, see row 7.b of Table 2 to 40 CFR 63 subpart DDDDD. PM emissions are the "filterable" fraction quantified via EPA RM5. PM emissions do not include the "condensible" fraction. See EPA final rulemaking in the October 25, 2012 Federal Register, pages 65107-65119, at http://www.gpo.gov/fdsys/pkg/FR-2012-10-25/pdf/2012-25978.pdf. The 0.008 lb/Mlb steam PM EF derived from stack testing is not employed to determine PTE because (a) control devices (multiclones and electrostatic precipitator (ESP)) were employed to reduce PM emission during the test and (b) the source is not required to achieve the emission rates observed. See Bison Engineering, Inc. April 22, 2016 Boiler MACT Stack Test Report prepared for Potlatch Land and Lumber, LLC. Table 5 of the report documents February 24, 2016 testing of CE boiler while generating approximately 34,300 lb steam/hr. 0.008 lb PM/Mlb steam = [(0.38 lb/hr / 33.355 Mlb steam/hr) + (0.19 lb/hr / 34.509 Mlb steam/hr) + (0.26 lb/hr / 35.069 Mlb steam/hr)] / 3.
EPA Region 10 Non-HAP Potential to Emit Emission Factors for Biomass Boilers Located in Pacific Northwest Indian Country, May 8, 2014. PM10 Option 4 for Boiler MACT PM emission limit applicable to existing fuel cell units designed to burn biomass/bio-based solid fuel. See https://www.epa.gov/sites/production/files/2016-09/documents/bbnonhappteef_memo.pdf. Assume all of filterable PM is PM10. Based upon April 2008 testing, condensible fraction is 6.3 lb/MMlb steam which is equivalent to 0.005 lb/MMBtu assuming FHISOR of 1.342 MMBtu/Mlb steam. 0.020 lb/MMBtu (filterable) + 0.005 lb/MMBtu (condensible) = 0.025 lb/MMBtu. Fine Particulate (PM2.5) 0.025
EPA Region 10 Non-HAP Potential to Emit Emission Factors for Biomass Boilers Located in Pacific Northwest Indian Country, May 8, 2014. PM2.5 Option 4 for Boiler MACT PM emission limit applicable to existing fuel cell units designed to burn biomass/bio-based solid fuel. See https://www.epa.gov/sites/production/files/2016-09/documents/bbnonhappteef_memo.pdf. Assume all of filterable PM is PM10. Based upon April 2008 testing, condensible fraction is 6.3 lb/MMlb steam which is equivalent to 0.005 lb/MMBtu assuming FHISOR of 1.342 MMBtu/Mlb steam. 0.020 lb/MMBtu (filterable) + 0.005 lb/MMBtu (condensible) = 0.025 lb/MMBtu. Sulfur Dioxide (SO2) 0.009 Biomass fuel upper bound sulfur estimate of 0.026% by weight (dry) and 15% conversion to SO2. See derivation of 0.009 lb/MMBtu EF below. PotlatchDeltic St. Maries Complex, Technical Support Document
PSD Permit No. R10PSD00100 and Minor NSR Permit No. R10TNSR01800 Horizon Engineering. Project No. 3020 Source Evaluation Report prepared for Potlatch Forest Products Corporation. Table 2 of the report documents April 30, 2008 testing of CE boiler while generating approximately 23,700 lb steam/hr. No VOC testing reported in 2016 Boiler MACT Stack Test Report. The three-run average value (as carbon) of 0.0067 lb/mlb steam is converted to 0.009 lb/Mlb steam (as compound emitted) assuming a weighted average VOC molecular weight of 64.7 lb/lb-mol and 4 carbon atoms per compound. The calculation to convert VOC (as carbon) to VOC (as compound) is displayed below. 8 percent of PM2.5 emissions, based on BART-recommended PM2.5 / sulfate speciation for hog fuel boilers. Page A-12 of A-74 Appendix A: Potential Emissions Inventory Greenhouse Gas Emissions (CO2 Equivalent) (lb/MMBtu) Carbon Dioxide (CO2) (lb/Mlb steam) 206.8 Methane (CH4) 1.764 Nitrous Oxide (N2O) 2.759
TOTAL (tpy) EF Reference 52,310.5 EPA Region 10 Non-HAP Potential to Emit Emission Factors for Biomass Boilers Located in Pacific Northwest Indian Country, May 8, 2014. CO2 Option 2 because the GHG Reporting Rule (40 CFR 98) is considered the primary reference for estimating GHG emissions when preparing or processing permit applications. See https://www.epa.gov/sites/production/files/201609/documents/bbnonhappteef_memo.pdf. 446.2
VOCC equals "0.0067 lb/Mlb steam" from April 30, 2008 testing of CE boiler. Value represents average value among three Method 25A test runs.
PSD Permit No. R10PSD00100 and Minor NSR Permit No. R10TNSR01800 Page A-13 of A-74 Appendix A: Potential Emissions Inventory The first two columns of the following table are extracted from AP-42, September 2003. Table 1.6-3. The third and fourth columns were created based upon information widely available over the internet. The fifth and sixth columns illustrate calculations necessary to determine weighted-average molecular weight and weighted-average number of carbon atoms comprising VOC emissions resulting from wood residue combustion. Wood Residue Combustion Organic Compounds Acenaphthene Acenaphthylene Acetaldehyde Acetone Acetophenone Acrolein Anthracene Benzaldehyde Benzene Benzo(a)anthracene Benzo(a)pyrene Benzo(b)fluoranthene Benzo(e)pyrene Benzo(g,h,i)perylene Benzo(j,k)fluoranthene Benzo(k)fluoranthene Benzoic acid Bis(2-ethylhexyl)phthalate (DEHP) Bromomethane (Methyle bromide) 2-Butanone (MEK) Carbazole Carbon tetrachloride Chlorobenzene Chloroform Chloromethane (Methyl chloride) 2-Chloronaphthalene 2-Chlorophenol Chrysene Crotonaldehyde
EPA Region 10 Non-HAP Potential to Emit Emission Factors for Biomass Boilers Located in Pacific Northwest Indian Country, May 8, 2014. CO Option 2 for Boiler MACT CO emission limit applicable to existing stokers/sloped grate/others designed to burn wet biomass fuel. See https://www.epa.gov/sites/production/files/2016-09/documents/bbnonhappteef_memo.pdf. Boiler MACT
CO emission limit of 1500 ppmdv @ 3% O2 equivalent to 1.231 lb/MMBtu for biomass combusted during February 2016 Boiler MACT testing in which Fd = 9669 dscf/MMBtu. See July 8, 2016 Notification of Compliance Status for Potlatch's selection of 3-hour average compliance option rather than 720 ppmdv @ 3% O2 30-day rolling average. Row 7.a of Table 2 to 40 CFR 63 subpart DDDDD. Boiler
CO emission rate of 0.967 lb/Mlb steam is not employed because the source is not required to achieve the emission rate observed. See Bison Engineering, Inc. April 22, 2016 Boiler MACT Stack Test Report prepared for Potlatch Land and Lumber, LLC. Table 3 of the report documents February 23, 2016 testing of CE boiler while generating approximately 90,100 lb steam/hr. 0.967 lb CO/Mlb steam = [(91.7 lb/hr / 90.026 Mlb steam/hr) + (98.2 lb/hr / 89.287 Mlb steam/hr) + (71.3 lb/hr / 90.990 Mlb steam/hr)] / 3. Page A-16 of A-74 Appendix A: Potential Emissions Inventory Lead (Pb) 0.000048 Nitrogen Oxides (NOX) Particulate (PM) 0.27 0.037 0.005 0.03
EPA Region 10 Non-HAP Potential to Emit Emission Factors for Biomass Boilers Located in Pacific Northwest Indian Country, May 8, 2014. Pb Option 1 as no emission limits apply. See https://www.epa.gov/sites/production/files/2016-09/documents/bbnonhappteef_memo.pdf 115.9 Horizon Engineering. Project No. 3020 Source Evaluation Report prepared for Potlatch Forest Products Corporation. Table 4 of the report documents May 1, 2008 testing of Riley boiler while generating approximately 96,900 lb steam/hr. No NOX testing reported in 2016 Boiler MACT Stack Test Report. 21.2
EPA Region 10 Non-HAP Potential to Emit Emission Factors for Biomass Boilers Located in Pacific Northwest Indian Country, May 8, 2014. PM Option 4 for Boiler MACT PM emission limit applicable to existing stokers/sloped grate/others designed to burn wet biomass fuel. See https://www.epa.gov/sites/production/files/2016-09/documents/bbnonhappteef_memo.pdf Boiler MACT
PM emission limit applicable at all times unit is operating except startup and shutdown. See July 8, 2016 Notification of Compliance Status for Potlatch's selection of PM compliance option rather than total selected metals. For PM limit, see row 7.b of Table 2 to 40 CFR 63 subpart DDDDD. PM emissions are the "filterable" fraction quantified via EPA RM5. PM emissions do not include the "condensible" fraction. See EPA final rulemaking in the October 25, 2012 Federal Register, pages 65107-65119, at http://www.gpo.gov/fdsys/pkg/FR-2012-10-25/pdf/2012-25978.pdf. The 0.005 lb/mlb steam PM EF derived from stack testing is not employed to determine PTE because (a) control devices (multiclones and electrostatic precipitator (ESP)) were employed to reduce PM emission during the test and (b) the source is not required to achieve the emission rates observed. See Bison Engineering, Inc. April 22, 2016 Boiler MACT Stack Test Report prepared for Potlatch Land and Lumber, LLC. Table 3 of the report documents February 23, 2016 testing of Riley boiler while generating approximately 90,100 lb steam/hr. 0.005 lb PM/Mlb steam = [(0.37 lb/hr / 90.026 Mlb steam/hr) + (0.49 lb/hr / 89.287 Mlb steam/hr) + (0.43 lb/hr / 90.990 Mlb steam/hr)] / 3. Inhalable Coarse Particulate (PM10) 0.039 22.3 Fine Particulate (PM2.5) 0.039 22.3 Sulfur Dioxide (SO2) 0.009 Volatile Organic Compounds (VOC) Sulfuric Acid Mist (H2SO4) 0.0106 0.0031 PotlatchDeltic St. Maries Complex, Technical Support Document
EPA Region 10 Non-HAP Potential to Emit Emission Factors for Biomass Boilers Located in Pacific Northwest Indian Country, May 8, 2014. PM Option 4 for Boiler MACT PM emission limit applicable to existing stokers/sloped grate/others designed to burn wet biomass fuel. See https://www.epa.gov/sites/production/files/2016-09/documents/bbnonhappteef_memo.pdf. Assume all of filterable PM is PM10. Based upon May 2008 testing, condensible fraction is 2.3 lb/MMlb steam which is equivalent to 0.002 lb/MMBtu assuming FHISOR of 1.335 MMBtu/Mlb steam. 0.037 lb/MMBtu (filterable) + 0.002 lb/MMBtu (condensible) = 0.039 lb/MMBtu.
TOTAL (tpy) EF Reference 118,503.7 EPA Region 10 Non-HAP Potential to Emit Emission Factors for Biomass Boilers Located in Pacific Northwest Indian Country, May 8, 2014. CO2 Option 2 because the GHG Reporting Rule (40 CFR 98) is considered the primary reference for estimating GHG emissions when preparing or processing permit applications. See https://www.epa.gov/sites/production/files/201609/documents/bbnonhappteef_memo.pdf. 1,010.8
VOCC equals "0.0078 lb/Mlb steam" from May 1, 2008 testing of Riley boiler. Value represents average value among three Method 25A test runs.
PSD Permit No. R10PSD00100 and Minor NSR Permit No. R10TNSR01800 Page A-18 of A-74 Appendix A: Potential Emissions Inventory The first two columns of the following table are extracted from AP-42, September 2003. Table 1.6-3. The third and fourth columns were created based upon information widely available over the internet. The fifth and sixth columns illustrate calculations necessary to determine weighted-average molecular weight and weighted-average number of carbon atoms comprising VOC emissions resulting from wood residue combustion. Wood Residue Combustion Organic Compounds Acenaphthene Acenaphthylene Acetaldehyde Acetone Acetophenone Acrolein Anthracene Benzaldehyde Benzene Benzo(a)anthracene Benzo(a)pyrene Benzo(b)fluoranthene Benzo(e)pyrene Benzo(g,h,i)perylene Benzo(j,k)fluoranthene Benzo(k)fluoranthene Benzoic acid Bis(2-ethylhexyl)phthalate (DEHP) Bromomethane (Methyle bromide) 2-Butanone (MEK) Carbazole Carbon tetrachloride Chlorobenzene Chloroform Chloromethane (Methyl chloride) 2-Chloronaphthalene 2-Chlorophenol Chrysene Crotonaldehyde
EF Reference Description February & May/June 2013 emissions testing of Hemlock lumber drying at less than 180°F within a pilot-scale kiln at Chemco in Ferndale, Washington. Testing was performed by Emission Technologies, Inc. on behalf of Sierra Pacific Industries and consisted of RM5 and 202. http://www.swcleanair.org/docs/Dry%20Kilns/SourceTests/2013-02-21%20Sierra%20Pacific%20-%20Chemco%20-%20Ferndale%20%20Dry%20Kiln%20PM%20Test%20Report.pdf & http://www.swcleanair.org/docs/Dry%20Kilns/SourceTests/2013-0529%20Sierra%20Pacific%20-%20Mt%20Vernon%20%20Pilot%20Dry%20Kiln%20Filterable%20and%20Condensable%20PM%20Test%20Report.pdf
EPA Region 10 HAP and VOC Emission Factors for Lumber Drying, December 2012. https://www.epa.gov/sites/production/files/201609/documents/ldkhapvocpteef_memo.pdf Species-Specific VOC Emissions Calculations Drying Time Species (hr/charge) HemFir (Hemlock/Grand Fir) Douglas Fir Larch Maximum Annual Charges (charges/yr)
Matter, Carbon Monoxide, Nitrogen Oxide, and Opacity Emission Factors. September 24, 2008. Table 1 of the report documents filterable and condensable particulate matter emission measurements downstream of the regenerative catalytic oxidizer.
EPA Region 10 HAP and VOC Emission Factors for Veneer Dryer Employing Indirect Steam Heat without Air Pollution Controls, February 2016. See https://www.epa.gov/sites/production/files/201603/documents/veneer-dryer-hap-voc-emissionfactors.pdf
EPA Region 10 is not aware of any emissions testing to measure PM, PM10 or PM2.5 emissions resulting from veneer dryer leaks. EPA Region 10 has estimated what these emissions might be based upon (1) measurement of post-control (regenerative catalytic oxidizer) filterable and condensable PM emissions generated by Potlatch veneer dryer heating section while processing resinous softwood non-pine family wood species, (2) assumption that filterable and condensable PM control efficiency across the regenerative catalytic oxidizer is approximately equal to measured VOC control efficiency of 94.2 percent, (3) measurement of methanol emissions generated by veneer dryer heating section and veneer dryer leaks at similar source to Potlatch while processing resinous softwood non-pine family wood species, and (4) assumption that PM/PM10/PM2.5 emissions across the two emission generating activities (veneer dryer heating section and veneer dryer leaks) are proportional to methanol emissions. The degree of uncertainty surrounding assumptions associated with items (2) and (4) is unknown. For further information with respect to item (3), see EPA Region 10 HAP and VOC Emission Factors for Veneer Dryer Employing Indirect Steam Heat without Air Pollution Controls, February 2016, at http://www.epa.gov/sites/production/files/2016-03/documents/veneer-dryer-hap-voc-emissionfactors.pdf PotlatchDeltic St. Maries Complex, Technical Support Document
VDHS-1 to 4 PM Uncontrolled EF = (VDHS-1 to 4 Filterable PM Controlled EF) / (1 - VOC control efficiency) = (0.014 lb/msf 3/8") / (1 - 0.942); Potlatch St. Maries September 2008 VDHS post-control (RCO) test measurements while processing "larch and red fir" = 0.2414 lb/msf 3/8"
VDHS-1 to 4 PM10/PM2.5 Uncontrolled EF = (VDHS-1 to 4 Filterable + Condensable PM Controlled EF) / (1 - VOC control efficiency) = (0.029 lb/msf 3/8") / (1 - 0.942); Potlatch St. Maries September 2008 VDHS post-control (RCO) test measurements while processing "larch and red fir" = 0.5 lb/msf 3/8"
SMC Non-HAP Potential to Emit Emission Units: VDCS-1, VDCS-2, VDCS-3 and VDCS-4 Description: Cooling sections of four steam-heated veneer dryers. Steam provided by PB-1 and PB-2. Make: Dryer Technology: Number of Heated Sections: Installation Date: Classification of Veneer Dried: Maximum Observed Operating Rate during September 24, 2008
PCWP MACT Testing (msf 3/8"/hr): Operation: Heated Section Control Technology: Observed RCO Exhaust Flow Rate during September 24, 2008 PCWP
VD-1 Moore Longitudinal February 1964 Re-dry
VD-2 Moore Longitudinal February 1964 Strips
VD-3 E.V. Preutire Prentice July 1967 Full Sheets
EF Reference Description Horizon Engineering. Project No. 3086-1. Source Evaluation Report prepared for Potlatch Forest Products Corporation. Veneer Dryers Nos. 1, 2, 3, 4 - Regenerative Catalytic Oxidizer Inlet and Outlet - Total Hazardous Air Pollutant Measured as Total Hydrocarbon - Plywood and Composite Wood Products MACT. September 24, 2008. Table 1 of the report documents total gaseous organic carbon destruction efficiency of 94.2 percent across the regenerative catalytic oxidizer. Horizon Engineering. Project No. 3086-2. Source Evaluation Report prepared for Potlatch Forest Products Corporation. Veneer Dryers Nos. 1, 2, 3, 4 - Regenerative Catalytic Oxidizer Outlet - Particulate
EPA Region 10 HAP and VOC Emission Factors for Veneer Dryer Employing Indirect Steam Heat without Air Pollution Controls, February 2016. See https://www.epa.gov/sites/production/files/201603/documents/veneer-dryer-hap-voc-emissionfactors.pdf PotlatchDeltic St. Maries Complex, Technical Support Document
PSD Permit No. R10PSD00100 and Minor NSR Permit No. R10TNSR01800 Page A-27 of A-74 Appendix A: Potential Emissions Inventory Interpoll Laboratories, Inc. Results of the May 2005 Air Emission Testing Conducted for The Potlatch Corporation Plywood Facility Located in St. Maries, Idaho. July 1, 2005. Potlatch Land and Lumber, LLC's March 2015 Consolidated Title V Operating Permit Application - Appendix C (Detailed Emission Calculations). The report does not indicate which species of wood was being dried while emissions testing was being conducted. Emission Unit Run No. Acetaldehyde Acrolein Benzene Formaldehyde Methanol Phenol Propionaldehyde 0.0017