{"document":{"doc_id":173906,"source":"docket_item","org":"EPA","doc_type":"other","title":"020_Potlatchdeltic_mnsr_analysis","date":"2022-10-12","url":"https://www.regulations.gov/document/EPA-R10-OAR-2020-0361-0021","source_native_id":"EPA-R10-OAR-2020-0361-0021","status":"fetched","abstract":null,"action":null},"dockets":["EPA-R10-OAR-2020-0361"],"rins":["RIN 2012-AA02"],"related":[{"doc_id":5204,"source":"fr_rule","org":"ENVIRONMENTAL PROTECTION AGENCY","doc_type":"Proposed Rule","title":"Federal Implementation Plans Under the Clean Air Act for Indian Reservations in Idaho, Oregon, and Washington","date":"2022-10-12"},{"doc_id":128388,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"211_EO12866_FARR Part 49 2012-AA02 PRM Response to Interagency Comments_EO 12866 Passback 6-14-2022","date":"2022-10-12"},{"doc_id":128389,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"212_EO12866_FARR Part 49 2012-AA02 PRM 20220527PL_EO 12866 Passback 6-14-2022","date":"2022-10-12"},{"doc_id":128390,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"214_EO12866_FARR Part 49 2012-AA02 PRM Response to Interagency Comments_EO 12866 20220624","date":"2022-10-12"},{"doc_id":128391,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"216_Part of E.O. 12866 Review EPA Response Interagency Comments Final Passback 20220707","date":"2022-10-12"},{"doc_id":128392,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"220_Part of E.O. 12866 Review Closing Review 20220711","date":"2022-10-12"},{"doc_id":128393,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"202_Part of E_O_ 12866 Review_ EPA Response to Initiated Review","date":"2022-10-12"},{"doc_id":128394,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"203_EO12866_FARR Part 49 2012-AA02 PRM Response to Interagency Comments 20220504","date":"2022-10-12"},{"doc_id":128395,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"206_EO12866_FARR Part 49 2012-AA02 PRM Response to Interagency Comments 20220513 passback2","date":"2022-10-12"},{"doc_id":128396,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"208_EO12866_FARR Part 49 2012-AA02 PRM Response to Interagency Comments 20220527","date":"2022-10-12"},{"doc_id":128397,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"210_Part of E.O. 12866 Review_passback 3_06142022","date":"2022-10-12"},{"doc_id":128398,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"213_Part of E.O. 12866 Review EPA Response Interagency Comments_20220624","date":"2022-10-12"},{"doc_id":128399,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"205_RE Part of E.O. 12866 Review 20220513 passback 2","date":"2022-10-12"},{"doc_id":128400,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"207_Part of E_O_ 12866 Review_ EPA Response to Interagency Comments 20220527","date":"2022-10-12"},{"doc_id":128401,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"200_5565_2012-AA02_FARR_proposed rule_20220208_EO12866_Initiated Interagency Comments 04042022","date":"2022-10-12"},{"doc_id":173905,"source":"docket_item","org":"EPA","doc_type":"data","title":"011_FORS 2019 Registrations.xls","date":"2022-10-12"},{"doc_id":173907,"source":"docket_item","org":"EPA","doc_type":"other","title":"021_potlatchdeltic_air quality impact analysis","date":"2022-10-12"},{"doc_id":204769,"source":"docket_item","org":"EPA","doc_type":"other","title":"401_EPA Form 7630-4","date":"2022-10-12"},{"doc_id":204770,"source":"docket_item","org":"EPA","doc_type":"other","title":"407_EPA Form 7630-10","date":"2022-10-12"},{"doc_id":204771,"source":"docket_item","org":"EPA","doc_type":"other","title":"409_EPA Form 7630-12","date":"2022-10-12"},{"doc_id":204772,"source":"docket_item","org":"EPA","doc_type":"other","title":"006_FARR Form 7630-8 NPT","date":"2022-10-12"},{"doc_id":204773,"source":"docket_item","org":"EPA","doc_type":"other","title":"014_EPA EJ Technical Guidance","date":"2022-10-12"},{"doc_id":204774,"source":"docket_item","org":"EPA","doc_type":"other","title":"108_EIA_2015_RECS - Annual hh site end-use consumption in US - totals and averages","date":"2022-10-12"},{"doc_id":204775,"source":"docket_item","org":"EPA","doc_type":"other","title":"100_FINAL_R10_FIP_EIA_01July2022","date":"2022-10-12"},{"doc_id":204777,"source":"docket_item","org":"EPA","doc_type":"other","title":"028_Orchard Heater Rules Summary","date":"2022-10-12"},{"doc_id":204778,"source":"docket_item","org":"EPA","doc_type":"other","title":"022_2015NSPSfs-overview","date":"2022-10-12"},{"doc_id":204779,"source":"docket_item","org":"EPA","doc_type":"other","title":"411_EPA Form 5800-066","date":"2022-10-12"},{"doc_id":204780,"source":"docket_item","org":"EPA","doc_type":"other","title":"217_EO12866_FARR Part 49 2012-AA02 PRM 20220707","date":"2022-10-12"},{"doc_id":204781,"source":"docket_item","org":"EPA","doc_type":"other","title":"403_EPA Form 7630-6","date":"2022-10-12"},{"doc_id":204783,"source":"docket_item","org":"EPA","doc_type":"other","title":"007_FARR Form 7630-12","date":"2022-10-12"},{"doc_id":204785,"source":"docket_item","org":"EPA","doc_type":"other","title":"015_Kamiah Monitoring Data Reports 2010-2019","date":"2022-10-12"},{"doc_id":204786,"source":"docket_item","org":"EPA","doc_type":"other","title":"109_EIA_2015_RECS - End-use expenditures in the West - totals and averages","date":"2022-10-12"},{"doc_id":204787,"source":"docket_item","org":"EPA","doc_type":"other","title":"408_EPA Form 7630-11","date":"2022-10-12"},{"doc_id":204788,"source":"docket_item","org":"EPA","doc_type":"other","title":"402_EPA Form 7630-5","date":"2022-10-12"},{"doc_id":204789,"source":"docket_item","org":"EPA","doc_type":"other","title":"204_EO12866_FARR Part 49 2012-AA02 PRM 20220504","date":"2022-10-12"},{"doc_id":204790,"source":"docket_item","org":"EPA","doc_type":"other","title":"218_FINAL_R10_FIP_EIA_07July2022_RLSO","date":"2022-10-12"},{"doc_id":204791,"source":"docket_item","org":"EPA","doc_type":"other","title":"008_2007-02-02 ltr from R10 to WA Hop Comm","date":"2022-10-12"},{"doc_id":204792,"source":"docket_item","org":"EPA","doc_type":"other","title":"110_SalaryTable_2021-SEA","date":"2022-10-12"},{"doc_id":204793,"source":"docket_item","org":"EPA","doc_type":"other","title":"102_Summary_FARR_Benefit_Calculations_final","date":"2022-10-12"},{"doc_id":204794,"source":"docket_item","org":"EPA","doc_type":"other","title":"016_Lapwai Monitoring Data Reports 2010-2019","date":"2022-10-12"},{"doc_id":204796,"source":"docket_item","org":"EPA","doc_type":"other","title":"029_Basis for the Applicability of the Additional FARR Rules to Specific Indian Reservations","date":"2022-10-12"},{"doc_id":204797,"source":"docket_item","org":"EPA","doc_type":"other","title":"400_ICR Supporting Statement 2703ss01","date":"2022-10-12"},{"doc_id":204798,"source":"docket_item","org":"EPA","doc_type":"other","title":"301_FARR Revisions Coord and Consult Record APPENDICES DRAFT RULES","date":"2022-10-12"},{"doc_id":204799,"source":"docket_item","org":"EPA","doc_type":"other","title":"009_2007-02-05 ltr from R10 to WA Mint Comm","date":"2022-10-12"},{"doc_id":204800,"source":"docket_item","org":"EPA","doc_type":"other","title":"001_EPA-HQ-OAR-2004-0067-0007_Final Response to Comments Document","date":"2022-10-12"},{"doc_id":204801,"source":"docket_item","org":"EPA","doc_type":"other","title":"026_id-st-maries-2021-path-forward-","date":"2022-10-12"},{"doc_id":204804,"source":"docket_item","org":"EPA","doc_type":"other","title":"017_EPA KotchenrutherwinterPM","date":"2022-10-12"},{"doc_id":204806,"source":"docket_item","org":"EPA","doc_type":"other","title":"023_EPA Certified Wood Burning Devices and FARR","date":"2022-10-12"},{"doc_id":204807,"source":"docket_item","org":"EPA","doc_type":"other","title":"215_EO12866_FARR Part 49 2012-AA02 PRM 20220624","date":"2022-10-12"},{"doc_id":204808,"source":"docket_item","org":"EPA","doc_type":"other","title":"410_EPA Form 5800-057","date":"2022-10-12"},{"doc_id":204809,"source":"docket_item","org":"EPA","doc_type":"other","title":"302_R10 Consultation and Coordination Procedures","date":"2022-10-12"},{"doc_id":204810,"source":"docket_item","org":"EPA","doc_type":"other","title":"027_Nez Perce Woodstove Changeout Scope FINAL","date":"2022-10-12"},{"doc_id":204811,"source":"docket_item","org":"EPA","doc_type":"other","title":"010_FORS 2015 Registrations","date":"2022-10-12"},{"doc_id":204812,"source":"docket_item","org":"EPA","doc_type":"other","title":"002_TSD for 2005 Rulemaking","date":"2022-10-12"},{"doc_id":204813,"source":"docket_item","org":"EPA","doc_type":"other","title":"018_EPA strategies for reducing residential wood smoke","date":"2022-10-12"},{"doc_id":204814,"source":"docket_item","org":"EPA","doc_type":"other","title":"104_Map of Nez Perce Reservation","date":"2022-10-12"},{"doc_id":204818,"source":"docket_item","org":"EPA","doc_type":"other","title":"030_FARR Rule 2005 and Proposed Comparison_RLSO","date":"2022-10-12"},{"doc_id":204819,"source":"docket_item","org":"EPA","doc_type":"other","title":"412_EPA Form 5800-077","date":"2022-10-12"},{"doc_id":204820,"source":"docket_item","org":"EPA","doc_type":"other","title":"209_EO12866_FARR Part 49 2012-AA02 PRM 20220527","date":"2022-10-12"},{"doc_id":204821,"source":"docket_item","org":"EPA","doc_type":"other","title":"003_BIA List of Tribes 2022","date":"2022-10-12"}],"references":[{"citation_id":1733182,"raw_reference":"Country, May 8, 2014. See https://www.epa.gov/sites/production/files/201609/documents/bbnonhappteef_memo.pdf. See Option 2 for Boiler MACT CO emission limit applicable to existing stokers/sloped grate/others designed to burn wet biomass fuel. Measured CO emission rate of 0.641 lb/MMBtu is not employed because the source is not required to achieve the emission rate observed. See Bison Engineering, Inc. April 22, 2016 Boiler MACT Stack Test Report prepared for Potlatch Land and Lumber, LLC. Table 7 of the report documents February 25, 2016 testing of Hurst boiler while generating approximately 28,500 lb steam/hr. 0.641 lb CO/Mlb steam = [(28.0 lb/hr / 28.389 Mlb steam/hr) + (5.9 lb/hr / 27.844 Mlb steam/hr) + (21.2 lb/hr / 29.244 Mlb steam/hr)] / 3.","cited_authors":"Country, May 8","cited_year":"2014","cited_title":"See https://www.epa.gov/sites/production/files/201609/documents/bbnonhappteef_memo.pdf","cited_venue":null,"cited_doi":null,"cited_url":"https://www.epa.gov/sites/production/files/201609/documents/bbnonhappteef_memo.pdf","ref_kind":"dataset","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733183,"raw_reference":"AP-42, September 2003. Table 1.6-4. Spidell and Associates. August 27, 2004 Source Test Report prepared for Potlatch Corporation. Table 2 of the report documents August 4, 2004 testing of Hurst boiler while generating approximately 31,500 lb steam/hr. 0.267 lb","cited_authors":"AP-42, September","cited_year":"2003","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"dataset","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733184,"raw_reference":"NOX/Mlb steam = [(8.84 lb/hr / 30.990 Mlb steam/hr) + (7.02 lb/hr / 32.271 Mlb steam/hr) + (9.32 lb/hr / 31.113 Mlb steam/hr)] / 3. No NOX testing reported in 2016 Boiler MACT Stack Test Report. Page A-4 of A-74 Appendix A: Potential Emissions Inventory Boiler MACT PM emission limit applicable at all times unit is operating except startup and shutdown. See July 8, 2016 Notification of Compliance Status for Potlatch's selection of PM compliance option rather than total selected metals. For PM limit, see row 7.b of Table 2 to 40 CFR 63 subpart DDDDD. PM emissions are the \"filterable\" fraction quantified via EPA RM5. PM emissions do not include the \"condensible\" fraction. See EPA final rulemaking in the October 25, 2012 Federal Register, pages 65107-65119, at http://www.gpo.gov/fdsys/pkg/FR-2012-1025/pdf/2012-25978.pdf. The 0.033 lb/mlb steam PM EF derived from stack testing is not employed to determine","cited_authors":null,"cited_year":null,"cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":"http://www.gpo.gov/fdsys/pkg/FR-2012-1025/pdf/2012-25978.pdf","ref_kind":"dataset","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733185,"raw_reference":"Engineering, Inc. April 22, 2016 Boiler MACT Stack Test Report prepared for Potlatch Land and Lumber, LLC. Table 7 of the report documents February 25, 2016 testing of Hurst boiler while generating approximately 28,500 lb steam/hr. 0.033 lb PM/Mlb steam = [(1.01 lb/hr / 28.389 Mlb steam/hr) + (0.81 lb/hr / 27.844 Mlb steam/hr) + (0.98 lb/hr / 29.244 Mlb steam/hr)] / 3. 0.054 10.8 Boiler MACT for filterable portion and AP-42's Table 1.6-1, September 2003 for condensible portion. Assume all PM is also PM10. 0.037 lb/MMBtu (filterable) + 0.017 lb/MMBtu (condensible) = 0.054 lb/MMBtu. Fine Particulate (PM2.5) 0.054 10.8 Boiler MACT for filterable portion and AP-42's Table 1.6-1, September 2003 for condensible portion. Assume all PM is also PM10. 0.037 lb/MMBtu (filterable) + 0.017 lb/MMBtu (condensible) = 0.054 lb/MMBtu. Sulfur Dioxide (SO2) 0.009 Volatile Organic Compounds (VOC) 0.0023 Sulfuric Acid Mist (H2SO4) 0.0043 Particulate (PM) 0.037 Inhalable Coarse Particulate (PM10) Greenhouse Gas Emissions (CO2 Equivalent) (lb/MMBtu) 0.033 (lb/mlb steam) Biomass fuel upper bound sulfur estimate of 0.026% by weight (dry) and 15% conversion to SO2. See derivation of 0.009 lb/MMBtu EF below. Travis Energy & Environment, Inc. December 18, 1994 Emission Test Report prepared for Potlatch Corp. Table 33b of the report documents November 16, 1994 testing of the Hurst boiler. The portions of the report provided to","cited_authors":null,"cited_year":null,"cited_title":"Engineering, Inc","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"dataset","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733186,"raw_reference":"EPA do not present the heat input or steam generating rates experienced during testing. We assume the heat input was approximately 49 MMBtu/hr during November 1994 testing as that was the rate calculated for the 2016 Boiler","cited_authors":null,"cited_year":null,"cited_title":"EPA do not present the heat input or steam generating rates experienced during testing","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733187,"raw_reference":"MACT testing. The 2016 Boiler MACT Stack Test Report indicates that no VOC testing was performed at that time, and the VOC testing conducted on August 4, 2004 was determined to be invalid by Idaho DEQ. See derivation of 0.002 lb/MMBtu EF below. 8 percent of PM2.5 emissions, based on BART-recommended PM2.5 / sulfate speciation for hog fuel boilers. (tpy)","cited_authors":null,"cited_year":null,"cited_title":"MACT testing","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733188,"raw_reference":"TOTAL 42,184 SO2 EF: 0.009 lb/MMBtu Basis: Maximum sulfur content of 0.026% by weight, dry basis was measured during March 2017 sampling event at the facility. Upper bound 15% conversion to SO2. See H. S. Oglesby & R.","cited_authors":null,"cited_year":null,"cited_title":"TOTAL 42,184 SO2 EF: 0.009 lb/MMBtu Basis: Maximum sulfur content of 0.026% by weight, dry basis was measured during March 2017 sampling event at the facility","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733189,"raw_reference":"Blosser (1980) Information on the Sulfur Content of Bark and its Contribution to SO2 Emissions when Burned as a Fuel, Journal of the Air Pollution Control Association, 30:7, 769-772, DOI:10.1080/00022470.1980.10465107. A 15% sulfur to SO2 conversion factor is a reasonable upper bound estimate given 10% conversion measured by Oglesby and Blosser based upon limited amount of data from a handful of species.","cited_authors":"Blosser","cited_year":"1980","cited_title":"Information on the Sulfur Content of Bark and its Contribution to SO2 Emissions when Burned as a Fuel, Journal of the Air Pollution Control Association, 30:7, 769-772, DOI:10.1080/00022470.1980.10465107","cited_venue":null,"cited_doi":"10.1080/00022470.1980.10465107","cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733190,"raw_reference":"VOCC equals \"0.0017 lb/MMBtu\" from December 18, 1994 Emission Test Report. Method 25A 0.0017 lb/MMBtu = 0.082 lb/hr / 49 MMBtu/hr.","cited_authors":null,"cited_year":null,"cited_title":"0.0017 lb/MMBtu","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733191,"raw_reference":"VOC (as weighted average VOC) 12.011 lb/MMBtu lb/lb-mol Factor to convert VOCC to VOC (as weighted average VOC) = 1.355 lb/lb-mol 3.975 0.0023 lb/MMBtu The first two columns of the following table are extracted from AP-42, September 2003. Table 1.6-3. The third and fourth columns were created based upon information widely available over the internet. The fifth and sixth columns illustrate calculations necessary to determine weighted-average molecular weight and weighted-average number of carbon atoms comprising VOC emissions resulting from wood residue combustion. Wood Residue Combustion Organic Compounds Acenaphthene Acenaphthylene Acetaldehyde Acetone Acetophenone Acrolein Anthracene Benzaldehyde Benzene Benzo(a)anthracene Benzo(a)pyrene Benzo(b)fluoranthene Benzo(e)pyrene Benzo(g,h,i)perylene Benzo(j,k)fluoranthene Benzo(k)fluoranthene Benzoic acid Bis(2-ethylhexyl)phthalate (DEHP) Bromomethane (Methyle bromide) 2-Butanone (MEK) Carbazole Carbon tetrachloride Chlorobenzene Chloroform Chloromethane (Methyl chloride) 2-Chloronaphthalene 2-Chlorophenol Chrysene Crotonaldehyde Decachlorobiphenyl Dibenzo(a,h)anthracene 1,2-Dibromoethene (lb/MMBtu)","cited_authors":"VOC (as weighted average VOC) 12.011 lb/MMBtu lb/lb-mol Factor to convert VOCC to VOC (as weighted average VOC) = 1.355 lb/lb-mol 3.975 0.0023 lb/MMBtu The first two columns of the following table are extracted from AP-42, September","cited_year":"2003","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733192,"raw_reference":"EF Reference Description February & May/June 2013 emissions testing of Hemlock lumber drying at less than 180°F within a pilot-scale kiln at Chemco in","cited_authors":null,"cited_year":null,"cited_title":"EF Reference Description February & May/June 2013 emissions testing of Hemlock lumber drying at less than 180°F within a pilot-scale kiln at Chemco in","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733193,"raw_reference":"Ferndale, Washington. Testing was performed by Emission Technologies, Inc. on behalf of Sierra Pacific Industries and consisted of RM5 and 202. http://www.swcleanair.org/docs/Dry%20Kilns/SourceTests/2013-02-21%20Sierra%20Pacific%20-%20Chemco%20%20Ferndale%20-%20Dry%20Kiln%20PM%20Test%20Report.pdf & http://www.swcleanair.org/docs/Dry%20Kilns/SourceTests/2013-05-29%20Sierra%20Pacific%20-%20Mt%20Vernon%20%20Pilot%20Dry%20Kiln%20Filterable%20and%20Condensable%20PM%20Test%20Report.pdf","cited_authors":null,"cited_year":null,"cited_title":"Ferndale, Washington","cited_venue":null,"cited_doi":null,"cited_url":"http://www.swcleanair.org/docs/Dry%20Kilns/SourceTests/2013-02-21%20Sierra%20Pacific%20-%20Chemco%20%20Ferndale%20-%20Dry%20Kiln%20PM%20Test%20Report.pdf","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733194,"raw_reference":"EPA Region 10 HAP and VOC Emission Factors for Lumber Drying, December 2012. https://www.epa.gov/sites/production/files/201609/documents/ldkhapvocpteef_memo.pdf PotlatchDeltic St. Maries Complex, Technical Support Document","cited_authors":"EPA Region 10 HAP and VOC Emission Factors for Lumber Drying, December","cited_year":"2012","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":"https://www.epa.gov/sites/production/files/201609/documents/ldkhapvocpteef_memo.pdf","ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733195,"raw_reference":"EPA Region 10 Non-HAP Potential to Emit Emission Factors for Biomass Boilers Located in Pacific Northwest Indian Country, May 8, 2014. CO Option 2 for Boiler MACT CO emission limit applicable to existing fuel cell units designed to burn biomass/bio-based solid fuel. See https://www.epa.gov/sites/production/files/2016-09/documents/bbnonhappteef_memo.pdf Boiler MACT","cited_authors":"EPA Region 10 Non-HAP Potential to Emit Emission Factors for Biomass Boilers Located in Pacific Northwest Indian Country, May 8","cited_year":"2014","cited_title":"CO Option 2 for Boiler MACT CO emission limit applicable to existing fuel cell units designed to burn biomass/bio-based solid fuel","cited_venue":null,"cited_doi":null,"cited_url":"https://www.epa.gov/sites/production/files/2016-09/documents/bbnonhappteef_memo.pdf","ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733196,"raw_reference":"CO emission limit of 1100 ppmdv @ 3% O2 equivalent to 0.914 lb/MMBtu for biomass combusted during February 2016 Boiler MACT testing in which Fd = 9791 dscf/MMBtu. There is only a 3-run average compliance option; there is no 30-day rolling average available. Row 12.a of Table 2 to 40 CFR 63 subpart DDDDD. Boiler MACT emission limit applicable at all times unit is operating except startup and shutdown. Measured CO emission rate of 0.635 lb/Mlb steam is not employed because the source is not required to achieve the emission rate observed. See Bison Engineering, Inc. April 22, 2016 Boiler","cited_authors":null,"cited_year":null,"cited_title":"CO emission limit of 1100 ppmdv @ 3% O2 equivalent to 0.914 lb/MMBtu for biomass combusted during February 2016 Boiler MACT testing in which Fd = 9791 dscf/MMBtu","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"dataset","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733197,"raw_reference":"MACT Stack Test Report prepared for Potlatch Land and Lumber, LLC. Table 5 of the report documents February 24, 2016 testing of CE boiler while generating approximately 34,300 lb steam/hr. 0.635 lb","cited_authors":null,"cited_year":null,"cited_title":"MACT Stack Test Report prepared for Potlatch Land and Lumber, LLC. Table 5 of the report documents February 24, 2016 testing of CE boiler while generating approximately 34,300 lb steam/hr","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"dataset","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733198,"raw_reference":"EPA Region 10 Non-HAP Potential to Emit Emission Factors for Biomass Boilers Located in Pacific Northwest Indian Country, May 8, 2014. Pb Option 1 as no emission limits apply. See https://www.epa.gov/sites/production/files/2016-09/documents/bbnonhappteef_memo.pdf 54.7 Horizon Engineering. Project No. 3020 Source Evaluation Report prepared for Potlatch Forest Products Corporation. Table 2 of the report documents April 30, 2008 testing of CE boiler while generating approximately 23,700 lb steam/hr. No NOX testing reported in 2016 Boiler MACT Stack Test Report.","cited_authors":"EPA Region 10 Non-HAP Potential to Emit Emission Factors for Biomass Boilers Located in Pacific Northwest Indian Country, May 8","cited_year":"2014","cited_title":"Pb Option 1 as no emission limits apply","cited_venue":null,"cited_doi":null,"cited_url":"https://www.epa.gov/sites/production/files/2016-09/documents/bbnonhappteef_memo.pdf","ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733199,"raw_reference":"EPA Region 10 Non-HAP Potential to Emit Emission Factors for Biomass Boilers Located in Pacific Northwest Indian Country, May 8, 2014. PM Option 4 for Boiler MACT PM emission limit applicable to existing fuel cell units designed to burn biomass/bio-based solid fuel. See https://www.epa.gov/sites/production/files/2016-09/documents/bbnonhappteef_memo.pdf Boiler MACT","cited_authors":"EPA Region 10 Non-HAP Potential to Emit Emission Factors for Biomass Boilers Located in Pacific Northwest Indian Country, May 8","cited_year":"2014","cited_title":"PM Option 4 for Boiler MACT PM emission limit applicable to existing fuel cell units designed to burn biomass/bio-based solid fuel","cited_venue":null,"cited_doi":null,"cited_url":"https://www.epa.gov/sites/production/files/2016-09/documents/bbnonhappteef_memo.pdf","ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733200,"raw_reference":"PM emission limit applicable at all times unit is operating except startup and shutdown. See July 8, 2016 Notification of Compliance Status for Potlatch's selection of PM compliance option rather than total selected metals. For PM limit, see row 7.b of Table 2 to 40 CFR 63 subpart DDDDD. PM emissions are the \"filterable\" fraction quantified via EPA RM5. PM emissions do not include the \"condensible\" fraction. See EPA final rulemaking in the October 25, 2012 Federal Register, pages 65107-65119, at http://www.gpo.gov/fdsys/pkg/FR-2012-10-25/pdf/2012-25978.pdf. The 0.008 lb/Mlb steam PM EF derived from stack testing is not employed to determine PTE because (a) control devices (multiclones and electrostatic precipitator (ESP)) were employed to reduce PM emission during the test and (b) the source is not required to achieve the emission rates observed. See Bison Engineering, Inc. April 22, 2016 Boiler MACT Stack Test Report prepared for Potlatch Land and Lumber, LLC. Table 5 of the report documents February 24, 2016 testing of CE boiler while generating approximately 34,300 lb steam/hr. 0.008 lb PM/Mlb steam = [(0.38 lb/hr / 33.355 Mlb steam/hr) + (0.19 lb/hr / 34.509 Mlb steam/hr) + (0.26 lb/hr / 35.069 Mlb steam/hr)] / 3.","cited_authors":null,"cited_year":null,"cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":"http://www.gpo.gov/fdsys/pkg/FR-2012-10-25/pdf/2012-25978.pdf","ref_kind":"dataset","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733201,"raw_reference":"EPA Region 10 Non-HAP Potential to Emit Emission Factors for Biomass Boilers Located in Pacific Northwest Indian Country, May 8, 2014. PM10 Option 4 for Boiler MACT PM emission limit applicable to existing fuel cell units designed to burn biomass/bio-based solid fuel. See https://www.epa.gov/sites/production/files/2016-09/documents/bbnonhappteef_memo.pdf. Assume all of filterable PM is PM10. Based upon April 2008 testing, condensible fraction is 6.3 lb/MMlb steam which is equivalent to 0.005 lb/MMBtu assuming FHISOR of 1.342 MMBtu/Mlb steam. 0.020 lb/MMBtu (filterable) + 0.005 lb/MMBtu (condensible) = 0.025 lb/MMBtu. Fine Particulate (PM2.5) 0.025","cited_authors":"EPA Region 10 Non-HAP Potential to Emit Emission Factors for Biomass Boilers Located in Pacific Northwest Indian Country, May 8","cited_year":"2014","cited_title":"PM10 Option 4 for Boiler MACT PM emission limit applicable to existing fuel cell units designed to burn biomass/bio-based solid fuel","cited_venue":null,"cited_doi":null,"cited_url":"https://www.epa.gov/sites/production/files/2016-09/documents/bbnonhappteef_memo.pdf","ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733202,"raw_reference":"EPA Region 10 Non-HAP Potential to Emit Emission Factors for Biomass Boilers Located in Pacific Northwest Indian Country, May 8, 2014. PM2.5 Option 4 for Boiler MACT PM emission limit applicable to existing fuel cell units designed to burn biomass/bio-based solid fuel. See https://www.epa.gov/sites/production/files/2016-09/documents/bbnonhappteef_memo.pdf. Assume all of filterable PM is PM10. Based upon April 2008 testing, condensible fraction is 6.3 lb/MMlb steam which is equivalent to 0.005 lb/MMBtu assuming FHISOR of 1.342 MMBtu/Mlb steam. 0.020 lb/MMBtu (filterable) + 0.005 lb/MMBtu (condensible) = 0.025 lb/MMBtu. Sulfur Dioxide (SO2) 0.009 Biomass fuel upper bound sulfur estimate of 0.026% by weight (dry) and 15% conversion to SO2. See derivation of 0.009 lb/MMBtu EF below. PotlatchDeltic St. Maries Complex, Technical Support Document","cited_authors":"EPA Region 10 Non-HAP Potential to Emit Emission Factors for Biomass Boilers Located in Pacific Northwest Indian Country, May 8","cited_year":"2014","cited_title":"PM2.5 Option 4 for Boiler MACT PM emission limit applicable to existing fuel cell units designed to burn biomass/bio-based solid fuel","cited_venue":null,"cited_doi":null,"cited_url":"https://www.epa.gov/sites/production/files/2016-09/documents/bbnonhappteef_memo.pdf","ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733203,"raw_reference":"PSD Permit No. R10PSD00100 and Minor NSR Permit No. R10TNSR01800 Horizon Engineering. Project No. 3020 Source Evaluation Report prepared for Potlatch Forest Products Corporation. Table 2 of the report documents April 30, 2008 testing of CE boiler while generating approximately 23,700 lb steam/hr. No VOC testing reported in 2016 Boiler MACT Stack Test Report. The three-run average value (as carbon) of 0.0067 lb/mlb steam is converted to 0.009 lb/Mlb steam (as compound emitted) assuming a weighted average VOC molecular weight of 64.7 lb/lb-mol and 4 carbon atoms per compound. The calculation to convert VOC (as carbon) to VOC (as compound) is displayed below. 8 percent of PM2.5 emissions, based on BART-recommended PM2.5 / sulfate speciation for hog fuel boilers. Page A-12 of A-74 Appendix A: Potential Emissions Inventory Greenhouse Gas Emissions (CO2 Equivalent) (lb/MMBtu) Carbon Dioxide (CO2) (lb/Mlb steam) 206.8 Methane (CH4) 1.764 Nitrous Oxide (N2O) 2.759","cited_authors":null,"cited_year":null,"cited_title":"PSD Permit No","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"dataset","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733204,"raw_reference":"TOTAL (tpy) EF Reference 52,310.5 EPA Region 10 Non-HAP Potential to Emit Emission Factors for Biomass Boilers Located in Pacific Northwest Indian Country, May 8, 2014. CO2 Option 2 because the GHG Reporting Rule (40 CFR 98) is considered the primary reference for estimating GHG emissions when preparing or processing permit applications. See https://www.epa.gov/sites/production/files/201609/documents/bbnonhappteef_memo.pdf. 446.2","cited_authors":"TOTAL (tpy) EF Reference 52,310.5 EPA Region 10 Non-HAP Potential to Emit Emission Factors for Biomass Boilers Located in Pacific Northwest Indian Country, May 8","cited_year":"2014","cited_title":"CO2 Option 2 because the GHG Reporting Rule (40 CFR 98) is considered the primary reference for estimating GHG emissions when preparing or processing permit applications","cited_venue":null,"cited_doi":null,"cited_url":"https://www.epa.gov/sites/production/files/201609/documents/bbnonhappteef_memo.pdf","ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733205,"raw_reference":"VOCC equals \"0.0067 lb/Mlb steam\" from April 30, 2008 testing of CE boiler. Value represents average value among three Method 25A test runs.","cited_authors":null,"cited_year":null,"cited_title":"0.0067 lb/Mlb steam","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733206,"raw_reference":"PSD Permit No. R10PSD00100 and Minor NSR Permit No. R10TNSR01800 Page A-13 of A-74 Appendix A: Potential Emissions Inventory The first two columns of the following table are extracted from AP-42, September 2003. Table 1.6-3. The third and fourth columns were created based upon information widely available over the internet. The fifth and sixth columns illustrate calculations necessary to determine weighted-average molecular weight and weighted-average number of carbon atoms comprising VOC emissions resulting from wood residue combustion. Wood Residue Combustion Organic Compounds Acenaphthene Acenaphthylene Acetaldehyde Acetone Acetophenone Acrolein Anthracene Benzaldehyde Benzene Benzo(a)anthracene Benzo(a)pyrene Benzo(b)fluoranthene Benzo(e)pyrene Benzo(g,h,i)perylene Benzo(j,k)fluoranthene Benzo(k)fluoranthene Benzoic acid Bis(2-ethylhexyl)phthalate (DEHP) Bromomethane (Methyle bromide) 2-Butanone (MEK) Carbazole Carbon tetrachloride Chlorobenzene Chloroform Chloromethane (Methyl chloride) 2-Chloronaphthalene 2-Chlorophenol Chrysene Crotonaldehyde","cited_authors":"PSD Permit No. R10PSD00100 and Minor NSR Permit No. R10TNSR01800 Page A-13 of A-74 Appendix A: Potential Emissions Inventory The first two columns of the following table are extracted from AP-42, September","cited_year":"2003","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"dataset","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733207,"raw_reference":"EPA Region 10 Non-HAP Potential to Emit Emission Factors for Biomass Boilers Located in Pacific Northwest Indian Country, May 8, 2014. CO Option 2 for Boiler MACT CO emission limit applicable to existing stokers/sloped grate/others designed to burn wet biomass fuel. See https://www.epa.gov/sites/production/files/2016-09/documents/bbnonhappteef_memo.pdf. Boiler MACT","cited_authors":"EPA Region 10 Non-HAP Potential to Emit Emission Factors for Biomass Boilers Located in Pacific Northwest Indian Country, May 8","cited_year":"2014","cited_title":"CO Option 2 for Boiler MACT CO emission limit applicable to existing stokers/sloped grate/others designed to burn wet biomass fuel","cited_venue":null,"cited_doi":null,"cited_url":"https://www.epa.gov/sites/production/files/2016-09/documents/bbnonhappteef_memo.pdf","ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733208,"raw_reference":"CO emission limit of 1500 ppmdv @ 3% O2 equivalent to 1.231 lb/MMBtu for biomass combusted during February 2016 Boiler MACT testing in which Fd = 9669 dscf/MMBtu. See July 8, 2016 Notification of Compliance Status for Potlatch's selection of 3-hour average compliance option rather than 720 ppmdv @ 3% O2 30-day rolling average. Row 7.a of Table 2 to 40 CFR 63 subpart DDDDD. Boiler","cited_authors":null,"cited_year":null,"cited_title":"CO emission limit of 1500 ppmdv @ 3% O2 equivalent to 1.231 lb/MMBtu for biomass combusted during February 2016 Boiler MACT testing in which Fd = 9669 dscf/MMBtu","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"dataset","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733209,"raw_reference":"CO emission rate of 0.967 lb/Mlb steam is not employed because the source is not required to achieve the emission rate observed. See Bison Engineering, Inc. April 22, 2016 Boiler MACT Stack Test Report prepared for Potlatch Land and Lumber, LLC. Table 3 of the report documents February 23, 2016 testing of CE boiler while generating approximately 90,100 lb steam/hr. 0.967 lb CO/Mlb steam = [(91.7 lb/hr / 90.026 Mlb steam/hr) + (98.2 lb/hr / 89.287 Mlb steam/hr) + (71.3 lb/hr / 90.990 Mlb steam/hr)] / 3. Page A-16 of A-74 Appendix A: Potential Emissions Inventory Lead (Pb) 0.000048 Nitrogen Oxides (NOX) Particulate (PM) 0.27 0.037 0.005 0.03","cited_authors":null,"cited_year":null,"cited_title":"CO emission rate of 0.967 lb/Mlb steam is not employed because the source is not required to achieve the emission rate observed","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"dataset","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733210,"raw_reference":"EPA Region 10 Non-HAP Potential to Emit Emission Factors for Biomass Boilers Located in Pacific Northwest Indian Country, May 8, 2014. Pb Option 1 as no emission limits apply. See https://www.epa.gov/sites/production/files/2016-09/documents/bbnonhappteef_memo.pdf 115.9 Horizon Engineering. Project No. 3020 Source Evaluation Report prepared for Potlatch Forest Products Corporation. Table 4 of the report documents May 1, 2008 testing of Riley boiler while generating approximately 96,900 lb steam/hr. No NOX testing reported in 2016 Boiler MACT Stack Test Report. 21.2","cited_authors":"EPA Region 10 Non-HAP Potential to Emit Emission Factors for Biomass Boilers Located in Pacific Northwest Indian Country, May 8","cited_year":"2014","cited_title":"Pb Option 1 as no emission limits apply","cited_venue":null,"cited_doi":null,"cited_url":"https://www.epa.gov/sites/production/files/2016-09/documents/bbnonhappteef_memo.pdf","ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733211,"raw_reference":"EPA Region 10 Non-HAP Potential to Emit Emission Factors for Biomass Boilers Located in Pacific Northwest Indian Country, May 8, 2014. PM Option 4 for Boiler MACT PM emission limit applicable to existing stokers/sloped grate/others designed to burn wet biomass fuel. See https://www.epa.gov/sites/production/files/2016-09/documents/bbnonhappteef_memo.pdf Boiler MACT","cited_authors":"EPA Region 10 Non-HAP Potential to Emit Emission Factors for Biomass Boilers Located in Pacific Northwest Indian Country, May 8","cited_year":"2014","cited_title":"PM Option 4 for Boiler MACT PM emission limit applicable to existing stokers/sloped grate/others designed to burn wet biomass fuel","cited_venue":null,"cited_doi":null,"cited_url":"https://www.epa.gov/sites/production/files/2016-09/documents/bbnonhappteef_memo.pdf","ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733212,"raw_reference":"PM emission limit applicable at all times unit is operating except startup and shutdown. See July 8, 2016 Notification of Compliance Status for Potlatch's selection of PM compliance option rather than total selected metals. For PM limit, see row 7.b of Table 2 to 40 CFR 63 subpart DDDDD. PM emissions are the \"filterable\" fraction quantified via EPA RM5. PM emissions do not include the \"condensible\" fraction. See EPA final rulemaking in the October 25, 2012 Federal Register, pages 65107-65119, at http://www.gpo.gov/fdsys/pkg/FR-2012-10-25/pdf/2012-25978.pdf. The 0.005 lb/mlb steam PM EF derived from stack testing is not employed to determine PTE because (a) control devices (multiclones and electrostatic precipitator (ESP)) were employed to reduce PM emission during the test and (b) the source is not required to achieve the emission rates observed. See Bison Engineering, Inc. April 22, 2016 Boiler MACT Stack Test Report prepared for Potlatch Land and Lumber, LLC. Table 3 of the report documents February 23, 2016 testing of Riley boiler while generating approximately 90,100 lb steam/hr. 0.005 lb PM/Mlb steam = [(0.37 lb/hr / 90.026 Mlb steam/hr) + (0.49 lb/hr / 89.287 Mlb steam/hr) + (0.43 lb/hr / 90.990 Mlb steam/hr)] / 3. Inhalable Coarse Particulate (PM10) 0.039 22.3 Fine Particulate (PM2.5) 0.039 22.3 Sulfur Dioxide (SO2) 0.009 Volatile Organic Compounds (VOC) Sulfuric Acid Mist (H2SO4) 0.0106 0.0031 PotlatchDeltic St. Maries Complex, Technical Support Document","cited_authors":null,"cited_year":null,"cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":"http://www.gpo.gov/fdsys/pkg/FR-2012-10-25/pdf/2012-25978.pdf","ref_kind":"dataset","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733213,"raw_reference":"EPA Region 10 Non-HAP Potential to Emit Emission Factors for Biomass Boilers Located in Pacific Northwest Indian Country, May 8, 2014. PM Option 4 for Boiler MACT PM emission limit applicable to existing stokers/sloped grate/others designed to burn wet biomass fuel. See https://www.epa.gov/sites/production/files/2016-09/documents/bbnonhappteef_memo.pdf. Assume all of filterable PM is PM10. Based upon May 2008 testing, condensible fraction is 2.3 lb/MMlb steam which is equivalent to 0.002 lb/MMBtu assuming FHISOR of 1.335 MMBtu/Mlb steam. 0.037 lb/MMBtu (filterable) + 0.002 lb/MMBtu (condensible) = 0.039 lb/MMBtu.","cited_authors":"EPA Region 10 Non-HAP Potential to Emit Emission Factors for Biomass Boilers Located in Pacific Northwest Indian Country, May 8","cited_year":"2014","cited_title":"PM Option 4 for Boiler MACT PM emission limit applicable to existing stokers/sloped grate/others designed to burn wet biomass fuel","cited_venue":null,"cited_doi":null,"cited_url":"https://www.epa.gov/sites/production/files/2016-09/documents/bbnonhappteef_memo.pdf","ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733214,"raw_reference":"TOTAL (tpy) EF Reference 118,503.7 EPA Region 10 Non-HAP Potential to Emit Emission Factors for Biomass Boilers Located in Pacific Northwest Indian Country, May 8, 2014. CO2 Option 2 because the GHG Reporting Rule (40 CFR 98) is considered the primary reference for estimating GHG emissions when preparing or processing permit applications. See https://www.epa.gov/sites/production/files/201609/documents/bbnonhappteef_memo.pdf. 1,010.8","cited_authors":"TOTAL (tpy) EF Reference 118,503.7 EPA Region 10 Non-HAP Potential to Emit Emission Factors for Biomass Boilers Located in Pacific Northwest Indian Country, May 8","cited_year":"2014","cited_title":"CO2 Option 2 because the GHG Reporting Rule (40 CFR 98) is considered the primary reference for estimating GHG emissions when preparing or processing permit applications","cited_venue":null,"cited_doi":null,"cited_url":"https://www.epa.gov/sites/production/files/201609/documents/bbnonhappteef_memo.pdf","ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733215,"raw_reference":"VOCC equals \"0.0078 lb/Mlb steam\" from May 1, 2008 testing of Riley boiler. Value represents average value among three Method 25A test runs.","cited_authors":null,"cited_year":null,"cited_title":"0.0078 lb/Mlb steam","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733216,"raw_reference":"PSD Permit No. R10PSD00100 and Minor NSR Permit No. R10TNSR01800 Page A-18 of A-74 Appendix A: Potential Emissions Inventory The first two columns of the following table are extracted from AP-42, September 2003. Table 1.6-3. The third and fourth columns were created based upon information widely available over the internet. The fifth and sixth columns illustrate calculations necessary to determine weighted-average molecular weight and weighted-average number of carbon atoms comprising VOC emissions resulting from wood residue combustion. Wood Residue Combustion Organic Compounds Acenaphthene Acenaphthylene Acetaldehyde Acetone Acetophenone Acrolein Anthracene Benzaldehyde Benzene Benzo(a)anthracene Benzo(a)pyrene Benzo(b)fluoranthene Benzo(e)pyrene Benzo(g,h,i)perylene Benzo(j,k)fluoranthene Benzo(k)fluoranthene Benzoic acid Bis(2-ethylhexyl)phthalate (DEHP) Bromomethane (Methyle bromide) 2-Butanone (MEK) Carbazole Carbon tetrachloride Chlorobenzene Chloroform Chloromethane (Methyl chloride) 2-Chloronaphthalene 2-Chlorophenol Chrysene Crotonaldehyde","cited_authors":"PSD Permit No. R10PSD00100 and Minor NSR Permit No. R10TNSR01800 Page A-18 of A-74 Appendix A: Potential Emissions Inventory The first two columns of the following table are extracted from AP-42, September","cited_year":"2003","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"dataset","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733217,"raw_reference":"EF Reference Description February & May/June 2013 emissions testing of Hemlock lumber drying at less than 180°F within a pilot-scale kiln at Chemco in Ferndale, Washington. Testing was performed by Emission Technologies, Inc. on behalf of Sierra Pacific Industries and consisted of RM5 and 202. http://www.swcleanair.org/docs/Dry%20Kilns/SourceTests/2013-02-21%20Sierra%20Pacific%20-%20Chemco%20-%20Ferndale%20%20Dry%20Kiln%20PM%20Test%20Report.pdf & http://www.swcleanair.org/docs/Dry%20Kilns/SourceTests/2013-0529%20Sierra%20Pacific%20-%20Mt%20Vernon%20%20Pilot%20Dry%20Kiln%20Filterable%20and%20Condensable%20PM%20Test%20Report.pdf","cited_authors":null,"cited_year":null,"cited_title":"EF Reference Description February & May/June 2013 emissions testing of Hemlock lumber drying at less than 180°F within a pilot-scale kiln at Chemco in Ferndale, Washington","cited_venue":null,"cited_doi":null,"cited_url":"http://www.swcleanair.org/docs/Dry%20Kilns/SourceTests/2013-02-21%20Sierra%20Pacific%20-%20Chemco%20-%20Ferndale%20%20Dry%20Kiln%20PM%20Test%20Report.pdf","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733218,"raw_reference":"EPA Region 10 HAP and VOC Emission Factors for Lumber Drying, December 2012. https://www.epa.gov/sites/production/files/201609/documents/ldkhapvocpteef_memo.pdf Species-Specific VOC Emissions Calculations Drying Time Species (hr/charge) HemFir (Hemlock/Grand Fir) Douglas Fir Larch Maximum Annual Charges (charges/yr)","cited_authors":"EPA Region 10 HAP and VOC Emission Factors for Lumber Drying, December","cited_year":"2012","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":"https://www.epa.gov/sites/production/files/201609/documents/ldkhapvocpteef_memo.pdf","ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733219,"raw_reference":"Matter, Carbon Monoxide, Nitrogen Oxide, and Opacity Emission Factors. September 24, 2008. Table 1 of the report documents filterable and condensable particulate matter emission measurements downstream of the regenerative catalytic oxidizer.","cited_authors":"Matter, Carbon Monoxide, Nitrogen Oxide, and Opacity Emission Factors. September 24","cited_year":"2008","cited_title":"Table 1 of the report documents filterable and condensable particulate matter emission measurements downstream of the regenerative catalytic oxidizer","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"dataset","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733220,"raw_reference":"EPA Region 10 HAP and VOC Emission Factors for Veneer Dryer Employing Indirect Steam Heat without Air Pollution Controls, February 2016. See https://www.epa.gov/sites/production/files/201603/documents/veneer-dryer-hap-voc-emissionfactors.pdf","cited_authors":"EPA Region 10 HAP and VOC Emission Factors for Veneer Dryer Employing Indirect Steam Heat without Air Pollution Controls, February","cited_year":"2016","cited_title":"See https://www.epa.gov/sites/production/files/201603/documents/veneer-dryer-hap-voc-emissionfactors.pdf","cited_venue":null,"cited_doi":null,"cited_url":"https://www.epa.gov/sites/production/files/201603/documents/veneer-dryer-hap-voc-emissionfactors.pdf","ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733221,"raw_reference":"EPA Region 10 is not aware of any emissions testing to measure PM, PM10 or PM2.5 emissions resulting from veneer dryer leaks. EPA Region 10 has estimated what these emissions might be based upon (1) measurement of post-control (regenerative catalytic oxidizer) filterable and condensable PM emissions generated by Potlatch veneer dryer heating section while processing resinous softwood non-pine family wood species, (2) assumption that filterable and condensable PM control efficiency across the regenerative catalytic oxidizer is approximately equal to measured VOC control efficiency of 94.2 percent, (3) measurement of methanol emissions generated by veneer dryer heating section and veneer dryer leaks at similar source to Potlatch while processing resinous softwood non-pine family wood species, and (4) assumption that PM/PM10/PM2.5 emissions across the two emission generating activities (veneer dryer heating section and veneer dryer leaks) are proportional to methanol emissions. The degree of uncertainty surrounding assumptions associated with items (2) and (4) is unknown. For further information with respect to item (3), see EPA Region 10 HAP and VOC Emission Factors for Veneer Dryer Employing Indirect Steam Heat without Air Pollution Controls, February 2016, at http://www.epa.gov/sites/production/files/2016-03/documents/veneer-dryer-hap-voc-emissionfactors.pdf PotlatchDeltic St. Maries Complex, Technical Support Document","cited_authors":"EPA Region 10 is not aware of any emissions testing to measure PM, PM10 or PM2.5 emissions resulting from veneer dryer leaks. EPA Region 10 has estimated what these emissions might be based upon (1) measurement of post-control (regenerative catalytic oxidizer) filterable and condensable PM emissions generated by Potlatch veneer dryer heating section while processing resinous softwood non-pine family wood species, (2) assumption that filterable and condensable PM control efficiency across the regenerative catalytic oxidizer is approximately equal to measured VOC control efficiency of 94.2 percent, (3) measurement of methanol emissions generated by veneer dryer heating section and veneer dryer leaks at similar source to Potlatch while processing resinous softwood non-pine family wood species, and (4) assumption that PM/PM10/PM2.5 emissions across the two emission generating activities (veneer dryer heating section and veneer dryer leaks) are proportional to methanol emissions. The degree of uncertainty surrounding assumptions associated with items (2) and (4) is unknown. For further information with respect to item (3), see EPA Region 10 HAP and VOC Emission Factors for Veneer Dryer Employing Indirect Steam Heat without Air Pollution Controls, February","cited_year":"2016","cited_title":"at http://www.epa.gov/sites/production/files/2016-03/documents/veneer-dryer-hap-voc-emissionfactors.pdf PotlatchDeltic St","cited_venue":null,"cited_doi":null,"cited_url":"http://www.epa.gov/sites/production/files/2016-03/documents/veneer-dryer-hap-voc-emissionfactors.pdf","ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733222,"raw_reference":"VDHS-1 to 4 PM Uncontrolled EF = (VDHS-1 to 4 Filterable PM Controlled EF) / (1 - VOC control efficiency) = (0.014 lb/msf 3/8\") / (1 - 0.942); Potlatch St. Maries September 2008 VDHS post-control (RCO) test measurements while processing \"larch and red fir\" = 0.2414 lb/msf 3/8\"","cited_authors":null,"cited_year":null,"cited_title":") / (1 - 0.942); Potlatch St. Maries September 2008 VDHS post-control (RCO) test measurements while processing","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733223,"raw_reference":"VDHS-1 to 4 PM10/PM2.5 Uncontrolled EF = (VDHS-1 to 4 Filterable + Condensable PM Controlled EF) / (1 - VOC control efficiency) = (0.029 lb/msf 3/8\") / (1 - 0.942); Potlatch St. Maries September 2008 VDHS post-control (RCO) test measurements while processing \"larch and red fir\" = 0.5 lb/msf 3/8\"","cited_authors":null,"cited_year":null,"cited_title":") / (1 - 0.942); Potlatch St. Maries September 2008 VDHS post-control (RCO) test measurements while processing","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733224,"raw_reference":"SMC Non-HAP Potential to Emit Emission Units: VDCS-1, VDCS-2, VDCS-3 and VDCS-4 Description: Cooling sections of four steam-heated veneer dryers. Steam provided by PB-1 and PB-2. Make: Dryer Technology: Number of Heated Sections: Installation Date: Classification of Veneer Dried: Maximum Observed Operating Rate during September 24, 2008","cited_authors":null,"cited_year":null,"cited_title":"SMC Non-HAP Potential to Emit Emission Units: VDCS-1, VDCS-2, VDCS-3 and VDCS-4 Description: Cooling sections of four steam-heated veneer dryers","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733225,"raw_reference":"PCWP MACT Testing (msf 3/8\"/hr): Operation: Heated Section Control Technology: Observed RCO Exhaust Flow Rate during September 24, 2008 PCWP","cited_authors":null,"cited_year":null,"cited_title":"PCWP MACT Testing (msf 3/8\"/hr): Operation: Heated Section Control Technology: Observed RCO Exhaust Flow Rate during September 24, 2008 PCWP","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733226,"raw_reference":"VD-1 Moore Longitudinal February 1964 Re-dry","cited_authors":null,"cited_year":null,"cited_title":"VD-1 Moore Longitudinal February 1964 Re-dry","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733227,"raw_reference":"VD-2 Moore Longitudinal February 1964 Strips","cited_authors":null,"cited_year":null,"cited_title":"VD-2 Moore Longitudinal February 1964 Strips","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733228,"raw_reference":"VD-3 E.V. Preutire Prentice July 1967 Full Sheets","cited_authors":null,"cited_year":null,"cited_title":"VD-3 E.V. Preutire Prentice July 1967 Full Sheets","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733229,"raw_reference":"EF Reference Description Horizon Engineering. Project No. 3086-1. Source Evaluation Report prepared for Potlatch Forest Products Corporation. Veneer Dryers Nos. 1, 2, 3, 4 - Regenerative Catalytic Oxidizer Inlet and Outlet - Total Hazardous Air Pollutant Measured as Total Hydrocarbon - Plywood and Composite Wood Products MACT. September 24, 2008. Table 1 of the report documents total gaseous organic carbon destruction efficiency of 94.2 percent across the regenerative catalytic oxidizer. Horizon Engineering. Project No. 3086-2. Source Evaluation Report prepared for Potlatch Forest Products Corporation. Veneer Dryers Nos. 1, 2, 3, 4 - Regenerative Catalytic Oxidizer Outlet - Particulate","cited_authors":"EF Reference Description Horizon Engineering. Project No. 3086-1. Source Evaluation Report prepared for Potlatch Forest Products Corporation. Veneer Dryers Nos. 1, 2, 3, 4 - Regenerative Catalytic Oxidizer Inlet and Outlet - Total Hazardous Air Pollutant Measured as Total Hydrocarbon - Plywood and Composite Wood Products MACT. September 24","cited_year":"2008","cited_title":"Table 1 of the report documents total gaseous organic carbon destruction efficiency of 94.2 percent across the regenerative catalytic oxidizer","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"dataset","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733230,"raw_reference":"EPA Region 10 HAP and VOC Emission Factors for Veneer Dryer Employing Indirect Steam Heat without Air Pollution Controls, February 2016. See https://www.epa.gov/sites/production/files/201603/documents/veneer-dryer-hap-voc-emissionfactors.pdf PotlatchDeltic St. Maries Complex, Technical Support Document","cited_authors":"EPA Region 10 HAP and VOC Emission Factors for Veneer Dryer Employing Indirect Steam Heat without Air Pollution Controls, February","cited_year":"2016","cited_title":"See https://www.epa.gov/sites/production/files/201603/documents/veneer-dryer-hap-voc-emissionfactors.pdf PotlatchDeltic St","cited_venue":null,"cited_doi":null,"cited_url":"https://www.epa.gov/sites/production/files/201603/documents/veneer-dryer-hap-voc-emissionfactors.pdf","ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733231,"raw_reference":"PSD Permit No. R10PSD00100 and Minor NSR Permit No. R10TNSR01800 Page A-27 of A-74 Appendix A: Potential Emissions Inventory Interpoll Laboratories, Inc. Results of the May 2005 Air Emission Testing Conducted for The Potlatch Corporation Plywood Facility Located in St. Maries, Idaho. July 1, 2005. Potlatch Land and Lumber, LLC's March 2015 Consolidated Title V Operating Permit Application - Appendix C (Detailed Emission Calculations). The report does not indicate which species of wood was being dried while emissions testing was being conducted. Emission Unit Run No. Acetaldehyde Acrolein Benzene Formaldehyde Methanol Phenol Propionaldehyde 0.0017","cited_authors":"PSD Permit No. R10PSD00100 and Minor NSR Permit No. R10TNSR01800 Page A-27 of A-74 Appendix A: Potential Emissions Inventory Interpoll Laboratories, Inc. Results of the May 2005 Air Emission Testing Conducted for The Potlatch Corporation Plywood Facility Located in St. Maries, Idaho. July 1","cited_year":"2005","cited_title":"Potlatch Land and Lumber, LLC's March 2015 Consolidated Title V Operating Permit Application - Appendix C (Detailed Emission Calculations)","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733232,"raw_reference":"EF Reference Description AP-42, Table 10.5-4, January 2002. In the absence of any PM2.5 EF, assume PM10 EF representative of PM2.5 EF. Derivation of emission factor presented at the conclusion of this emissions inventory. PotlatchDeltic St. Maries Complex, Technical Support Document","cited_authors":"EF Reference Description AP-42, Table 10.5-4, January","cited_year":"2002","cited_title":"In the absence of any PM2.5 EF, assume PM10 EF representative of PM2.5 EF. Derivation of emission factor presented at the conclusion of this emissions inventory","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733233,"raw_reference":"Hemlock, douglas fir, grand fir and western red cedar. Smaller amounts of Wood Species: lodgepole pine, subalpine fir, engelmann spruce, ponderosa pine and white pine Installation Date: 1964 Capacity: msf (3/8\")/hr Operation: 8760 hr/yr","cited_authors":null,"cited_year":null,"cited_title":"Hemlock, douglas fir, grand fir and western red cedar","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733234,"raw_reference":"TOTAL (tpy): EF Reference Heat Input = Power Output (MMBtu/hr) X Average BSFC (Btu/hp-hr) X (MMBtu/1x106 Btu), where BSFC stands for brake-specific fuel consumption. See footnote A of Table 3.3-1 of AP-42, October 1996. 1.86 MMBtu/hr = (265 hp-hr) X (7,000 Btu/hp-hr) X (MMBtu/1x106 Btu) The engines are emergency stationary reciprocating internal combustion engines subject to NESHAP subpart ZZZZ, and the proposed Title V permit prohibits the permittee from operating them in non-emergency situations for more than 100 hours per calendar year pursuant to 40 CFR 63.6640(f).","cited_authors":"TOTAL (tpy): EF Reference Heat Input = Power Output (MMBtu/hr) X Average BSFC (Btu/hp-hr) X (MMBtu/1x106 Btu), where BSFC stands for brake-specific fuel consumption. See footnote A of Table 3.3-1 of AP-42, October","cited_year":"1996","cited_title":"1.86 MMBtu/hr = (265 hp-hr) X (7,000 Btu/hp-hr) X (MMBtu/1x106 Btu) The engines are emergency stationary reciprocating internal combustion engines subject to NESHAP subpart ZZZZ, and the proposed Title V permit prohibits the permittee from operating them in non-emergency situations for more than 100 hours per calendar year pursuant to 40 CFR 63.6640(f)","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733235,"raw_reference":"FARR PM FARR PM Calculated EF Emission Limit (gr/dscf @7%O2) (lb/MMBtu) 0.1871 • Assume PM2.5 = PM10 = PM PotlatchDeltic St. Maries Complex, Technical Support Document","cited_authors":null,"cited_year":null,"cited_title":"FARR PM FARR PM Calculated EF Emission Limit (gr/dscf @7%O2) (lb/MMBtu) 0.1871 • Assume PM2.5 = PM10 = PM PotlatchDeltic St","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733236,"raw_reference":"PSD Permit No. R10PSD00100 and Minor NSR Permit No. R10TNSR01800 CF7→0%O2 CFgr→lb (unitless) 1.504 (dscf/MMBtu) 8,710 (gr/lb) 7,000 Page A-38 of A-74 Appendix A: Potential Emissions Inventory Basis: FARR PM limit for filterable portion and AP-42's Table 3.2-3, July 2000 for condensible portion of 0.00991 lb/MMBtu. Assume all PM is also PM10 and PM2.5. 0.1871 lb/MMBtu (filterable) + 0.00991 lb/MMBtu (condensible) = 0.19701 lb/MMBtu. Option 1: 0.0173 lb/MMBtu. This emission factor is employed to determine PTE as it limits emissions to less than Options 2 and 3 below. Basis: Pursuant to ASTM D1835-16 and Gas Processors Association (GPA) Standard 2140, the sulfur content of commerical propane must not exceed 185 ppm by mass.","cited_authors":null,"cited_year":null,"cited_title":"PSD Permit No","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"dataset","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733237,"raw_reference":"EF (lb/MMBtu) = [ASTM & GPA Fuel S Limit (ppm) / 1x106] X CFS→SO2 X CFlb→gal (lb/gal) X CFBtu→MMBtu (Btu/MMBtu) / CFgal→Btu (Btu/gal) • CFS→SO2 = 2 lb SO2/lb S. S + O2 → SO2. For every 1 mol S (16 lb/lb-mol) reactant, there is 1 mol SO2 (32 lb/lb-mol) product. 32 / 16 = 2. • CFlb→gal = 4.24 lb/gal fuel at 60°F. See weight of liquid propane on page A-6 of Appendix A to AP-42, September 1985. • CFgal→Btu = 90,500 Btu/gal fuel. See heating value of liquid propane on page A-6 of Appendix A to AP-42, September 1985.","cited_authors":"EF (lb/MMBtu) = [ASTM & GPA Fuel S Limit (ppm) / 1x106] X CFS→SO2 X CFlb→gal (lb/gal) X CFBtu→MMBtu (Btu/MMBtu) / CFgal→Btu (Btu/gal) • CFS→SO2 = 2 lb SO2/lb S. S + O2 → SO2. For every 1 mol S (16 lb/lb-mol) reactant, there is 1 mol SO2 (32 lb/lb-mol) product. 32 / 16 = 2. • CFlb→gal = 4.24 lb/gal fuel at 60°F. See weight of liquid propane on page A-6 of Appendix A to AP-42, September","cited_year":"1985","cited_title":"• CFgal→Btu = 90,500 Btu/gal fuel","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733238,"raw_reference":"NON-FUGITIVE EMISSIONS Potential to Emit, (tons per year) Seal/Surface Coating Material Edge Seal Surface Coating Material Content (lb/gal) 0.02 0.83 2012 Actual 2012 Actual Maximum Material Plywood Plywood Usage Coated Throughput (msf 3/8\"/yr) (msf 3/8\"/yr) (gal/yr) 3,596 5,570 350,400 5,570 350,400","cited_authors":null,"cited_year":null,"cited_title":"/yr) (msf 3/8","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733239,"raw_reference":"TOTAL (tpy): Projected Maximum Mateial Usage (gal/yr) 226,219 44,036 (tpy) 18.3 20.5 Projected maximum material usage = (2012 actual material usage) X (maximum plywood throughput) / (2012 actual plywood throughput)","cited_authors":null,"cited_year":null,"cited_title":"TOTAL (tpy): Projected Maximum Mateial Usage (gal/yr) 226,219 44,036 (tpy) 18.3 20.5 Projected maximum material usage = (2012 actual material usage) X (maximum plywood throughput) / (2012 actual plywood throughput)","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733240,"raw_reference":"EF Reference March 2015 Potlatch Part 71 Renewal Application PotlatchDeltic St. Maries Complex, Technical Support Document","cited_authors":null,"cited_year":null,"cited_title":"EF Reference March 2015 Potlatch Part 71 Renewal Application PotlatchDeltic St","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733241,"raw_reference":"NON-FUGITIVE EMISSIONS Potential to Emit, (tons per year) Patch Material Putty Material Content (lb/gal) 0.32 2014 Actual 2014 Actual Maximum Plywood Plywood Material Usage Throughput Throughput (gal/yr) (msf 3/8\"/yr) (msf 3/8\"/yr) 57,701 144,313 350,400 Projected Maximum Material Usage (gal/yr) 140,101","cited_authors":null,"cited_year":null,"cited_title":"/yr) (msf 3/8","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733242,"raw_reference":"TOTAL (tpy): (tpy) 22.4 22.4 Projected maximum patch material usage = (2014 actual patch usage) X (maximum plywood throughput) / (2014 actual plywood throughput)","cited_authors":null,"cited_year":null,"cited_title":"TOTAL (tpy): (tpy) 22.4 22.4 Projected maximum patch material usage = (2014 actual patch usage) X (maximum plywood throughput) / (2014 actual plywood throughput)","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733243,"raw_reference":"EF Reference March 2015 Potlatch Part 71 Renewal Application Emission Unit: PP Description: Two synthetic patch lines Combined Dryer Rated Capacity: msf 3/8\"/hr Operation: 8760 hr/yr","cited_authors":null,"cited_year":null,"cited_title":"EF Reference March 2015 Potlatch Part 71 Renewal Application Emission Unit: PP Description: Two synthetic patch lines Combined Dryer Rated Capacity: msf 3/8\"/hr Operation: 8760 hr/yr","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733244,"raw_reference":"NON-FUGITIVE EMISSIONS Potential to Emit, (tons per year) Patch Material Part A Part B Material Content (lb/gal) 2014 Actual 2014 Actual Maximum Material Plywood Plywood Usage Throughput Throughput (msf 3/8\"/yr) (msf 3/8\"/yr) (gal/yr) 71,875 144,313 350,400 12,720 144,313 350,400","cited_authors":null,"cited_year":null,"cited_title":"/yr) (msf 3/8","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":1733245,"raw_reference":"TOTAL (tpy): Projected Maximum Material Usage (gal/yr) 174,517 30,885 (tpy) Projected maximum patch material usage = (2014 actual patch usage) X (maximum plywood throughput) / (2014 actual plywood throughput)","cited_authors":null,"cited_year":null,"cited_title":"TOTAL (tpy): Projected Maximum Material Usage (gal/yr) 174,517 30,885 (tpy) Projected maximum patch material usage = (2014 actual patch usage) X (maximum plywood throughput) / (2014 actual plywood throughput)","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null}]}