Response to 2019 Section 114 ICR from Centurion Medical Products in Howell, MI
Original sourcePDF at sourceAttachment at sourceAttachment at sourceAttachment at sourcePDF at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at source
Other documents for the same rulemaking
References
SER V1 Cls Medline Industries - Howell, Ml 2019 Destruction Efficiency Test Report
FTIR EPA 320 Ethylene Oxide FTIR EPA320 928ET-647141 12 of 87 ~MONTROSE 11 AIR QUALITY ~fRVIC[!I Medline Industries - Howell, Ml 2019 Destruction Efficiency Test Report 3.4.1
QUALITY CONTROL PROCEDURES Our Quality Assurance Program Summary. located in Appendix A, provides our equipment maintenance and calibration schedule, quality control acceptance limits, and any corrective action that may be needed. For additional quality control, Montrose followed the procedures outlined below and in the method write-ups in Section 3.4. 928ET-647141 14of 87 ~ MONTROSE Ala. Q.U.-.LITY )(~VICf) Medline Industries - Howell, Ml 2019 Destruction Efficiency Test Report 4.2.1 Equipment Inspection and Maintenance Each critical piece of field equipment was assigned a unique identification number to allow tracking of its calibration history All field equipment was visually inspected prior to testing and included pre-test calibration checks 4.2.2 Equipment Calibrations Our equipment maintenance and calibration schedule is located in Appendix A.
OUTLET DETECTION LIMIT The MAX Analytical Starboost FTIR was used in measuring the outlet EtO concentrations. According to ASTM 0-6348, the detection limits are calculated as three times the noise equivalent absorbance. The minimum detectable concentration (MDC) for EtO at the outlet was 7.8 ppb. During the DE testing of the TO, several data points were below the detection limit (non-detect). For these data points the detection limit of 7.8 ppb was used in calculating the run average. 928ET-647141 16 of 87 ~MONTRO~E I I AIR Q_UALl{Y ~ERVlCllo Medline Industries - Howell, Ml 2019 Destruction Efficiency Test Report
ZERO SYSTEM_0000084.LAB 11:56 0.005 Noise Equivalent Absorbance (Standard Deviation) 0.002 Minimum Detectable Concentration (MDC) 0.0078 928ET-647141 17 of8.r Medline Industries - Howell, Ml 2019 Destruction Efficiency Test Report