Original sourcePDF at sourcePDF at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at sourceAttachment at source
Other documents for the same rulemaking
References
PEL: 1ppm STEL: 5 ppm OSHA 1910 MSDS Attached Page 3 of 3
CERTIFICATE OF ANALYSIS Primary Standard Requested Certified Concentration Concentration Analytical Analytical (Molar) (Molar) Reference Uncertainty 10ppm 10.2 ppm :i: 1 % Balance Balance Component Ethylene oxide Nitrogen Cylinder Style: A3 Cylinder Pressure@ 70 F: 2000 psig Cylinder Volume: 28.3 ft3 Valve Outlet Connection: CGA 350 Cylinder Number(s): EA0022418 · Fill Date:3/8/2019 Analysis Date: 3/14/2019 Filling Method: Gravimetric Key to Analytical Technique : Raferance Analytlcal instnimeht - Analytical Principia Hewlett-Packarcf6890 - Gas Chromatography with FID
ISO 9001 Registered 37256 Highway 30 Gelsmar, LA 70734 Tel: 225-677-nOO Fax: 225-673-3531 1fffl Certificate Issuance Date: Customer & Order Information: 5/6/2019 Certification Date: 5/6/2019 Lot Number: 70340 9119 1 F Part Number: NI EO100P-A3 DocNumber: 71177 Expiration Date: 4/30/2021
CERTIFICATE OF ANALYSIS Primary Standard Ethylene oxide Requested Certified Concentration Concentration Analytical Analytical (Molar) (Molar) Reference Uncertainty 100 ppm 100 ppm Nitrogen Balance Component Cylinder Style: A3 Cylinder Pressure @ 70 F: 2000 pslg Cylinder Volume: 28.7 ft3 Valve Outlet Connection: CGA 350 Cylinder Number(s): EA0023428 Fill Date:4/29/2019 Analysis Date: 4/30/2019 Balance Filling Method: Gravimetric fb., ..t-k-~ Analyst RDnnle Key to Analytical Techniques: Reference · Analytical Instrument • Analytical Prlnclple Hewlett-Packard 6890 - Gas Chromatography with FID The gas calib1'1111on cylinder standard prepared by PraXalr Distribution, Inc. is considered a camfied standarll. 11 IB prepared by gravlmetr1c, 1101umetr1c, or partial prasStn tedlnlqUea. The cellbrallon slaldard provided Is certified again&! Praxair Dlatrtt>ution, Inc. Reference Materials which are either prepared by weights traceable to the National Institute of Standarlls and Technology (NIST), Measurement Canada, or by using NIST Stendarll Reference Matertals where available. Note: All expra881on1 for concentration (e.g., 'II, or ppm) &I'll for gas phase, by volume (a.g., ppmv) unau otllefWlae noted. Analytical uncartanlty Is expl'llssed as a Ralatlve 'II, unlau otharwlae noted.