Shintani 2017. Ethylene oxide gas sterilization of medical devices. (3/25/2015)
Other documents for the same rulemaking
References: 64 extracted, 0 linked to papers
AAMI TIR 15 2009. Physical Aspect of Ethylene Oxide Sterilization. Association for the Advancement of Medical
Instrumentation, Arlington, USA. AAMI TIR 16 2009. Microbiological Aspects of Ethylene Oxide Sterilization. Association for the Advancement of Medical
Instrumentation, Arlington, USA. AAMI TIR 17 2008. Compatibility of Materials Subject to Sterilization. Association for the Advancement of Medical
AAMI TIR 19 1998 AAMI TIR 17 2008. Guidance for ANSI/
AAMI/ISO 10993-7: 1995. Biological Evaluation of Medical Devices- Part 7. Ethylene Oxide Residue. Association for the Advancement of Medical Instrumentation, Arlington,
USA. AAMI TIR 19/A1 1999, AAMI TIR 17 2008. Guidance for ANSI/
AAMI/ISO 10993-7: 1995. Biological Evaluation of Medical Devices- Part 7. Ethylene Oxide Residue. Association for the Advancement of Medical Instrumentation, Arlington, USA.
AAMI TIR 20 2001. Parametric Release for EO Sterilization. Association for the Advancement of Medical Instrumentation,
Arlington, USA. AAMI TIR 28 2009. Product Adoption and Process Equivalency for Ethylene Oxide Sterilization. Association for the Advancement of Medical Instrumentation, Arlington, USA.
Alfa, M. J., DeGagne, R., and Olson, N. 1997 Bacterial killing ability of 10 ethylene oxide plus 90 hydrochlorofluorocarbon sterilizing gas. Infection Control and Hospital Epidemiology. 18, 641-645.
Alfa M. J., DeGagne, R, Olson, N., and Hizon, R. 1998a Comparison of liquid chemical sterilization with peracetic acid and ethylene oxide sterilization for long narrow lumens. Am. J. Infect. Control., 26, 469-477.
Alfa M. J., DeGagne, R, Olson, N., and Puchalski, T.1996 Comparison of ion plasma, vaporized hydrogen peroxide and 100 ethylene oxide sterilizers to the 12/88 ethylene oxide gas sterilizer. Infect. Control Hosp. Epidemiol., 17, 92-100.
Alfa, M. J., DeGagne, R, Olson, N., and Hizon, R. 1998b New low temperature sterilization technologies: microbicidal activity and clinical efficacy. In Rutala, W. A. ed.
ANSI/AAMI ST 41 2008 . Ethylene Oxide Sterilization in Health Care Facilities: Safety and Effectiveness. Association for the Advancement of Medical Instrumentation, Arlington,
USA. Buben, I., Melichercfkovji, V, Novotn1 N., and Svitjkovj, R. 1999 Problems associated with sterilization using ethylene oxide. Residues in treated materials. Cent. Europ. J. Public Health, 4, 197-202.
Ernest, R. R.1973 Ethylene Oxide Gaseous Sterilization for Industrial Applications. Industrial Sterilization. Amsterdam: Duke University Press.
Handlos, V.1980 Kinetics of the aeration of ethylene-oxide sterilized plastics. Biomaterials, 1, 149-157.
ISO 10993-7 2008. Biological Evaluation of Medical DevicesPart 7; Ethylene Oxide Sterilization Residuals. International Organization for Standardization, USA.
USA. ISO 11138-1 2006. Sterilization of Health Care ProductsBiological Indicators. Part 1:General Requirements. International Organization for Standardization, USA.
ISO 11138-2 2006. Sterilization of Health Care ProductsBiological Indicators. Part 2: Biological Indicators for Ethylene Oxide Sterilization Processes. International Organization for Standardization, USA.
ISO 14161 2009. Sterilization of Health Care Products-Biological Indicators.-Guidance for the Selection, Use and Interpretation of Results. International Organization for Standardization,
USA. ISO 11137 2012 Sterilization of health care products –Radiation.
McNamee, S. G., Lyle, D. B., and Brown, S. A. 2003 Residual ethylene oxide in medical devices and device material. J. Biomed. Mater. Res., 66B, 548-552.
Mendes, G. C., Brandao, T. R., and Silva, C. L. 2007 Ethylene oxide sterilization of medical devices: A review. Am. J. Infect. Disease. 35, 574-581.
Mendes, G. C., Brandao, T. R., and Silva, C. L. 2008 Ethylene Oxide Potential Toxicity. Expert Rev. Med. Devices, 5, 323-328.
Mosley, G. A., Gillis, J. R., and Krushefski, G. 2005 Evaluating the formulae for integrated lethality in ethylene oxide sterilization using six different endospores forming strains of bacteria, and comparisons of integrated lethality for ethylene oxide and steam systems. PDA J. Pharm Sci. Technol., 59, 64-86.
Mosley, G. A., Gillis, J. R., and Whitbourne, J. E. 2002 Calculating equivalent time for use in determining the lethality of EtO sterilization processes. Med. Device Diagnost. Indust.
News, 24, 54-63. Mosley, G. A., and Houghtling, C. W.2005 Interpreting and understanding microbial data in validation of ethylene oxide sterilization processes. Biomed. Instrument. Technol., 39, 466-482.
Muzeni, R. J.1985 Rapid gas chromatographic determination of ethylene oxide, ethylene chlorhydrin and ethylene glycol residues in rubber catheters, J. Assoc. Official Anal. Chem., 68, 506-508. NFPA70 2008. National Electric Code Handbook. National Fire Protection Association, USA. Poothuli1, J., Shimizu, A., Day, R. R., and Dolovich, J. 1975 Anaphylaxis from the product s of ethylene oxide gas. Ann. Internal Medicine, 82, 58-60.
Ries, M. D., Weaver, K., and Beals, N. 1996 Safety and efficacy of ethylene oxide sterilized polyethylene in total knee arthroplasty. Clin. Orthoped. 159-163.
Rodriguez, A. C., Young, B., Cauck, K., Zelewski, J., Kwasnica, S., and Aguirre, S. 2001 Calculating accumulated lethality and survivorship in EtO sterilization processes. Med. Dev. Diagnost. Indust. News, 23, 100-107.
Rogers, W. 2005 Sterilization of Polymer Healthcare Products. Shrewsbury: Rapra Technology.
Rutala, XV. A., Gergen, M. F., and Weber, D. J. 1998 Comparative evaluation of the sporicidal activity of new low temperature sterilization technologies: Ethylene oxide, 2 plasma sterilization systems, and liquid peracetic acid. Am. J. Infect. Cont., 26, 393-398.
Scott, H. 1982 Solubility parameter, specific molar cohesion, and the solubility of ethylene oxide in polymers. Biomater., 3, 195-198.
Shintani, H., Suzuki, H., and Oba, T.1981a Qualitative and quantitative aspects of ethylene chlorohydrin, ethylene glycol; and the other reaction products of ethylene oxide in saline during the prolonged incubation. Hygienic Scinces, 27, 285-295.
Shintani, H., and Oba, T.1981b Colorimetric determination of residual ethylene oxide on medical devices. Hygienic
Scinces, 27, 224-230. Shintani, H., and Nakamura, A. 1991a Mechanisms of degradation and crosslinking of polyurethane when irradiated by gamma-rays. J. Applied Polymer Sci., 42, 1979-1987.
Shintani, H., and Nakamura, A. 1991b Formation of 4,4 H. SHINTANI -methylenedianiline in polyurethane potting materials by either gamma-ray or autoclave sterilization. J. Biomed. Mater. Res., 25, 1275-1286.
Shintani, H. 1991c Degradation and cross-linking pf polyurethane irradiated by gamma-rays. Polymer Degradation and Stability, 32, 191-208.
Shintani, H.1991d Solid-phase extraction of a carcinogen, 4,4 -methylenedianiline, in serum. J. Anal. Toxicol., 15, 198201.
Shintani, H.1992 Gamma-radiation and autoclave sterilization of thermophilic and thermosetting polyurethane. J. Rad. Steril., 1, 11-28.
Shintani, H., Hata, Y., and Nakamura, A.1993 Solid phase extraction and HPLC analysis of toxic components eluted from methyl methacrylate dental materials. J. Anal. Toxicol., 17, 73-78.
Shintani, H.1995a The relative safety of gamma-ray, autoclave, and ethylene oxide gas sterilization of thermosetting polyurethanes. Biomed. Instrument. Technol., 29, 513-519.
Shintani, H 1995b Formation and elution of toxic compounds from sterilized medical products: methylenedianiline formation in polyurethane. J. Biomater. Appl., 10, 23-58.
Shintani, H.1995c Comparison of D10-value accuracy by the limited Sperman-Karber procedure LSKP , the Stumbo-Murphy-Cochran procedure SMCP , and the survival-curve methodEN . Biomed. Instrument. Technol., 29, 113-124.
Shintani, H. 1996a Formation and elution if toxic compounds from sterilized medical products: Toxic compound formation from irradiated products. Rad. Phys. Chem., 47, 139-148.
Shintani, H. 1996b Comparison of solid phase extraction and dialysis on pretreatment efficiency of blood urea analysis. J. Chromatogr. Science, 34, 92-98.
Shintani, H. 2001a Confirmation of the sterility of medical devices and changes in the characteristics of polymers upon sterilization. Biocontyrol Science, 6, 63-68.
Shintani, H.2004a Study on radiation sterilization-Resistant polysulfones fabricated free from bisphenol A. Trends Biomaterial Art. Organs, 18, 36-40.
Shintani, H., taniai, E., Miki, A., Kurosu, S., and Hayashi, F. 2004b Comparison of the collecting efficiency of microbiological air samplers. J. Hosp. Infect., 56, 42-48.