Characterization of Air Emissions from Open Burning at the Radford Army Ammunition Plant
Other documents for the same rulemaking (all, by stage)
References: 33 extracted, 0 linked to papers
Aurell, J.; Gullett, B.K.; Tabor, D.; Williams, R.K.; Mitchell, W.; Kemme, M.R. Aerostat-based sampling of emissions from open burning and open detonation of military ordnance. Journal of Hazardous Materials. 284:108-120; 2015.
Ragland, K.W.; Aerts, D.J.; Baker, A.J. Properties of wood for combustion analysis. Bioresource Technology. 37:161-168; 1991.
Aurell, J.; Gullett, B. Characterization of Emissions from Open Burning of Meals Readyto-Eat and their Paperboard Packaging. EPA 600/R-16/220. U.S. EPA. 2016. https://nepis.epa.gov/Exe/ZyPDF.cgi/P100PZ6F.PDF?Dockey=P100PZ6F.PDF Accessed April 5, 2017 U.S. EPA Method 3A. Determination of oxygen and carbon dioxide concentrations in emissions from stationary sources (instrumental analyzer procedure). 1989. http://www.epa.gov/ttn/emc/promgate/m-03a.pdf Accessed May 5, 2014 40 CFR Part 50, Appendix L. Reference method for the determination of particulate matter as PM2.5 in the Atmosphere. 1987. https://www.gpo.gov/fdsys/pkg/CFR-2014title40-vol2/pdf/CFR-2014-title40-vol2-part50-appL.pdf Accessed November 22, 2016 U.S. EPA Compendium Method IO-3.3. Determination of metals in ambient particulate matter using X-Ray Fluorescence (XRF) Spectroscopy. 1999. http://www.epa.gov/ttnamti1/files/ambient/inorganic/mthd-3-3.pdf Accessed May 5, 2014 U.S. EPA Hazardous Air Pollution List. Clean Air Act: Title 42 - The public health and welfare. U.S. Government Printing Office. 2008. http://www.gpo.gov/fdsys/pkg/USCODE-2008-title42/pdf/USCODE-2008-title42chap85.pdf Accessed May 5 2014 U.S. EPA SOP. Standard Operating Procedure for the Determination of Hexavalent Chromium In Ambient Air Analyzed By Ion Chromatography (IC). 2006. https://www3.epa.gov/ttnamti1/files/ambient/airtox/hexchromsop.pdf Accessed April 4, 2017 U.S. EPA Method TO-17. Determination of Volatile Organic Compounds in Ambient Air
Tohyama, C.; Tritscher, A.; Tuomisto, J.; Tysklind, M.; Walker, N.; Peterson, R.E. The 2005 World Health Organization reevaluation of human and mammalian toxic equivalency factors for dioxins and dioxin-like compounds. Toxicological Sciences 93:223-241; 2006.
Warneke, C.; Urbanski, S.P.; Reardon, J.; Weise, D.R.; Hao, W.M.; de Gouw, J. Laboratory measurements of trace gas emissions from biomass burning of fuel types from the southeastern and southwestern United States. Atmospheric Chemistry and Physics 10:11115-11130; 2010. CH2M HILL. Human Health Risk Assessment for the Open Burning Ground, Radford
Army Ammunition Plant. 2005. Gullett, B.K.; Aurell, J.; Williams, R. Characterization of Air Emissions from Open Burning and Open Detonation of Gun Propellants and Ammunition. SERDP WP-2233. 2016. https://www.serdp-estcp.org/index.php/Program-Areas/Weapons-Systems-andPlatforms/Energetic-Materials-and-Munitions/Munitions-Emissions/WP-2233/WP-2233TR Accessed March 29, 2017
VOC, and PCDD/PCDF. Environmental Science & Technology. 47:8443-8452; 2013.
Aurell, J.; Gullett, B.K.; Yamamoto, D. Emissions from Open Burning of Simulated Military Waste from Forward Operating Bases. Environmental Science & Technology. 46:11004-11012; 2012. Appendices Appendix A: Element emission factors Table A-1. Elements analyzed for each sample collected in mg/kg initial source.a Date MK90 MK90 MK90 MK90 MK90 Skid waste Skid waste 09/27/16 09/27/16 10/05/16 10/05/16 10/05/16 10/06/16 10/06/16 Element Unit Burn 1 Burn 2,3 Burn 1 Burn 2 Burn 3 Burn 1 Burn 1 mg/kg initial source 8.58E+02 9.24E+02 1.06E+03 1.05E+03 6.66E+02 2.77E+01 4.32E+01 Na Unc. mg/kg initial source 1.16E+02 1.37E+02 1.62E+02 1.68E+02 1.32E+02 1.40E+01 1.61E+01 mg/kg initial source 1.40E+02 1.66E+02 1.96E+02 1.86E+02 1.25E+02 1.91E+00 2.92E+00 Mg Unc.
PS-SW-HCl-092816-01 1-Topp R1611762-001 Service Request: R1611762 Date Collected: 09/28/16 Date Received: 10/28/16 09:30 Units: ug/Filter Basis: As Received Perchlorates in Water, Soils, Solid Wastes Using High Performance LC/Electrospray/Mass Spectrometry Analysis Method: Prep Method: 6850 Method Analyte Name Chlorate Perchlorate Result 0.0040 U 0.0040 U 0.0040 0.0040 Printed 11/30/2016 9:09:08 AM Dil. Date Analyzed 11/09/16 10:57 11/09/16 10:57 Date Extracted 11/8/16 11/8/16 Superset Reference:16-0000400334 rev 00 20 of 41
CO from AirGas (ca. 100 ppm) will be used for calibration. All gas cylinders used for calibration are certified by the suppliers that they are traceable to NIST standards. A precision dilution calibrator Serinus Cal 2000 (American ECOTECH L.C., Warren, RI, USA) will be used to dilute the high-level span gases for acquiring the mid-point concentrations for the e2V EC4-500-CO calibration curves. The Serinus Cal will be evaluated in the field as specified in U.S. EPA Method 205 – Verification of Gas Dilution Systems for Field Instrument Calibrations 4. Table 4-2. CO Quality Information. Target Compound Sampling/ Measurement/ Analytical Method Sampling Rate
Aurell, J.; Gullett, B. K.; Tabor, D.; Williams, R. K.; Mitchell, W.; Kemme, M. R. Aerostatbased sampling of emissions from open burning and open detonation of military ordnance. Journal of Hazardous Materials 2015, 284 (0), 108-120. U.S. EPA Hazardous Air Pollution List.Clean Air Act: Title 42 - The public health and welfare. U.S. Government Printing Office, 2008; p 5713, http://www.gpo.gov/fdsys/pkg/USCODE-2008-title42/pdf/USCODE-2008-title42-chap85.pdf. U.S. EPA Method 3A.Determination of oxygen and carbon dioxide concentrations in emissions from stationary sources (instrumental analyzer procedure). 1989, http://www.epa.gov/ttn/emc/promgate/m-03a.pdf.
EPA, U. S. EPA Method 205. Verification of Gas Dilution Systems for Field Instrument Calibrations. http://www3.epa.gov/ttn/emc/methods/method205.html. Accessed 9/17/2015. 2015. U.S. EPA Method TO-17.Determination of Volatile Organic Compounds in Ambient Air
ANODIZING OPERATIONS—ISOKINETIC METHOD. https://www3.epa.gov/ttnemc01/promgate/m-306.pdf. U.S. EPA Method SW-846 Test Method 0061.Determination of Hexavalent Chromium Emissions from Stationary Sources. 1996, https://www.epa.gov/sites/production/files/201512/documents/0061.pdf. International standard ISO 21438-2:2009.Workplace atmospheres — Determination of inorganic acids by ion chromatography — Part 2: Volatile acids, except hydrofluoric acid (hydrochloric acid, hydrobromic acid and nitric acid). 2009, Measurement of HCl in workplace air. 2006, Institut National de Recherche et de Sécurité.Anions Minéraux Fiche Métropol 009. 2002,
Lamm, S. H.; Braverman, L. E.; Li, F. X.; Richman, K.; Pino, S.; Howearth, G. Thyroid health status of ammonium perchlorate workers: a cross-sectional occupational health study. Journal of Occupational & Environmental Medicine 1999, 41 (4), 248-260. U.S. EPA Method 26.Determination of Hydrogen Halide and Halogen Emissions from Stationary Sources Non-Isokinetic Method. https://www3.epa.gov/ttnemc01/promgate/m26.pdf.
Johnson, T. J.; Reardon, J.; Weise, D. R. Airborne and ground-based measurements of the trace gases and particles emitted by prescribed fires in the United States. Atmospheric Chemistry and Physics 2011, 11 (23), 12197-12216. Appendix F: Data Quality Audit Radford DQA
US Environmental Protection Agency Audit Date: August 9-11, 2017 Auditors: Libby Nessley, AEMD QA Manager Immediate Office of the Director
ORD. Over a 2-week period the team sampled 33 plumes, determining emissions factors for particulate matter, metals, chloride, perchlorate, volatile organic compounds, chlorinated dioxins/furans, and nitrogen-based organics. A summary report titled Characterization of Air Emissions from Open Burning at the Radford Army Ammunition Plant was generated by EPA ORD detailing sampling and analytical results. This data quality audit (DQA) focused on traceability of the reported results back to the raw data. Original laboratory reports were reviewed to ensure data was entered correctly in to spreadsheets. Spreadsheet calculations were checked and verified to be accurate. The origin of 100% of the data included in the report was traced back to the original spreadsheet or laboratory report. Associated data and calculations in ancillary spreadsheets and files were reviewed at a rate of approximately 100% for the 09-27-2016 test to check use of spreadsheets for calculation of emission factors. Other test dates were reviewed at a rate or approximately 10%. 2.0 Data QA Review Process 100% of the data in the Radford report was traced back to the original spreadsheet or laboratory report from which it came. The following folders and files were provided by the EPA Principal Investigator for use in the DQA and evaluating spreadsheets and calculation of emission factors:
Alvarado, M., Gonzalez, F., Erskine, P., Cliff, D., Heuff, D., 2017. A methodology to monitor airborne PM10 dust particles using a small unmanned aerial vehicle. Sensors 17, 343.
Aurell, J., Gullett, B.K., 2010. Aerostat sampling of PCDD/PCDF emissions from the gulf oil spill in situ burns. Environ. Sci. Technol. 44, 9431e9437.
Aurell, J., Gullett, B.K., Pressley, C., Tabor, D., Gribble, R., 2011. Aerostat-lofted instrument and sampling method for determination of emissions from open area sources. Chemosphere 85, 806e811.
Aurell, J., Gullett, B.K., Tabor, D., 2015. Emissions from southeastern U.S. Grasslands and pine savannas: comparison of aerial and ground field measurements with laboratory burns. Atmos. Environ. 111, 170e178.
Aurell, J., Gullett, B.K., Tabor, D., Williams, R.K., Mitchell, W., Kemme, M.R., 2015. Aerostat-based sampling of emissions from open burning and open detonation of military ordnance. J. Hazard Mater 284, 108e120.
Bjorklund, J., Bowers, J., Dodd, G., White, J., 1998. Open Burzzning/Open Detonation (OBODM) User's Guide. DPG Document No. DPG-TR-96e008b. U. S. Army Dugway Proving Ground, Dugway, UT. http://www.epa.gov/ttn/scram/userg/ nonepa/obodmvol2.pdf. (Accessed 14 July 2017).
Brady, J.M., Stokes, M.D., Bonnardel, J., Bertram, T.H., 2016. Characterization of a quadrotor unmanned aircraft system for aerosol-particle-concentration measurements. Environ. Sci. Technol. 50, 1376e1383.
Johnson, T.J., Reardon, J., Weise, D.R., 2011. Airborne and ground-based measurements of the trace gases and particles emitted by prescribed fires in the United States. Atmos. Chem. Phys. 11, 12197e12216.
Chang, C.-C., Wang, J.-L., Chang, C.-Y., Liang, M.-C., Lin, M.-R., 2016. Development of a multicopter-carried whole air sampling apparatus and its applications in environmental studies. Chemosphere 144, 484e492. International standard ISO 21438-2:2009, 2009. Workplace Atmospheres d Determination of Inorganic Acids by Ion Chromatography d Part 2: Volatile
Rudek, J., 2017. Assessing the methane emissions from natural gas-fired power Plants and oil refineries. Environ. Sci. Technol. 51, 3373e3381.
McGonigle, A.J.S., Aiuppa, A., Giudice, G., Tamburello, G., Hodson, A.J., Gurrieri, S., 2008. Unmanned aerial vehicle measurements of volcanic carbon dioxide fluxes. Geophys Res. Lett. 35. Nelson Jr., R.M., 1982. An Evaluation of the Carbon Balance Technique for Estimating Emission Factors and Fuel Consumption in Forest Fires. US Department of
NC, USA. Research Paper SE-231. Peng, Z.-R., Wang, D., Wang, Z., Gao, Y., Lu, S., 2015. A study of vertical distribution patterns of PM2.5 concentrations based on ambient monitoring with unmanned aerial vehicles: a case in Hangzhou, China. Atmos. Environ. 123, 357e369.
Villa, T.F., Salimi, F., Morton, K., Morawska, L., Gonzalez, F., 2016. Development and validation of a UAV based system for air pollution measurements. Sensors 16.
Weise, D.R., 2013. Coupling field and laboratory measurements to estimate the emission factors of identified and unidentified trace gases for prescribed fires. Atmos. Chem. Phys. 13, 89e116. https://doi.org/110.5194/acp-5113-5189-2013.
Zhou, X., Aurell, J., Mitchell, W., Tabor, D., Gullett, B., 2016. A small, lightweight multipollutant sensor system for ground-mobile and aerial emission sampling from open area sources. Atm Env. 154, 31e41.
http://dx.doi.org/10.1016/j.atmosenv.2017.07.046