Global Non-CO2 Greenhouse Gas Emission Projections & Marginal Abatement Cost Analysis: Methodology Documentation
Other documents for the same rulemaking (all, by stage)
References: 399 extracted, 0 linked to papers
Amazon. 2013. Falcon DPSGRN Dust-Off ECO duster, 5 oz Canister (Case of 12). http://www.amazon.com/industrial-scientific/dp/B009L9A2X6
Cook, S., TechSpray. August 2008. Personal communication with Emily Herzog, ICF International.
Ecofys. 2000. Abatement of Emissions of Other Greenhouse Gases: Engineered Chemicals. Prepared for the International Energy Agency Greenhouse Gas Research and Design Programme. Enviros. March 2000. Study on the Use of HFCs for Metered Dose Inhalers in the European Union. Commissioned by the International Pharmaceutical Aerosol Consortium (IPAC).
ITW Chemtronics. 2013. Typhoon BlastTM duster. http://www.chemtronics.com/products/product.asp?id=598
Malerba, A., Honeywell. November 2011a. E-mail communication with Pamela Mathis, ICF International. Miller-Stephenson. 2013. Aero-Duster® product information. http://www.millerstephenson.com/assets/1/Store%20Item/MS-222L.pdf
Nardini, G., May 2002. Personal communication with Iliriana Mushkolaj, ICF Consulting. 5-148 Global Non-CO2 Greenhouse Gas Emissions Projections & Marginal Abatement Cost Analysis
SECTION 5 — SECTOR-LEVEL METHODS Price, D., E. Valovirta, and J. Fischer. 2004. The importance of preserving choice in inhalation therapy: The CFC transition and beyond. Journal of Drug Assessment, 7, 45–61. Stanley Supply & Services, 2013. Techspray Renew 1580-10S Eco-Duster, 10oz. http://www.stanleysupplyservices.com/techspray-renew-1580-10s-eco-duster-10oz/p/477-260
Tourigny, J., MicroCare Corporation. August 2008. Personal communication with Emily Herzog, ICF International.
Tourigny, J., MicroCare Corporation. November 2011. E-mail communication with Emily Herzog, ICF International.
United Nations Environment Programme. 1999. 1998 Report of the Solvents, Coatings, and Adhesives Technical Options Committee (STOC): 1998 Assessment. Nairobi, Kenya: UNEP Ozone Secretariat.
United Nations Environment Programme. 2010. Report of the UNEP Medical Technical Options Committee: 2010 Assessment. Nairobi, Kenya: UNEP Ozone Secretariat. Global Non-CO2 Greenhouse Gas Emissions Projections & Marginal Abatement Cost Analysis 5-149
FK-5-1-12-mmy2 (also known as 1,1,1,2,2,4,5,5,5-nonafluoro-4-[trifluoromethyl]-3-pentanone, and commonly referred to as FK-5-1-12) is a fluorinated ketone with an atmospheric lifetime of 5 days and a 100-year GWP of approximately 1 (Kidde Fire Protection, 2011). This option examines use of FK-5-1-12 in total flooding systems. The option is applicable in new Class A total flooding applications, replacing HFCs (primarily HFC-227ea). Class A total flooding application end uses represent an estimated 95% of the total flooding sector; the additional adoption of
METHODOLOGY DOCUMENTATION cooling costs associated with this option result in an assumed annual cost of $0.17 per cubic meter of protected space for developed countries. In developing countries, annual costs were assumed to be 66% greater because of higher electricity costs. Annual Revenue: Because, on average, 0.633 kilogram of HFC-227ea is needed to protect 1 cubic meter of space (Wickham, 2003) and assuming a release rate of 2% of the installed base, the emission of approximately 13 grams of HFC-227ea is avoided each year per cubic meter of protected space. Based on an average HFC-227ea cost of about $24 per kilogram (Werner, 2011), this translates into an annual savings of $0.30 per cubic meter of protected space. These annual savings are assumed to be the same in all regions. Water Mist Systems in New Class B Total Flooding Applications Water mist systems use relatively small droplet sprays under low, medium, or high pressure to extinguish fires. These systems use specially designed nozzles to produce much smaller droplets than are produced by traditional water-spray systems or conventional sprinklers, so they use less water to extinguish a fire (UNEP, 2001;
ICF International. March 2009. Opportunities for Combined Heat and Power in Data Center. Prepared for Oak Ridge National Laboratory. Available online at https://www1.eere.energy.gov/manufacturing/datacenters/pdfs/chp_data_centers.pdf International Maritime Organization. November 30, 2001. Performance Testing and Approval Standards for Fire Safety Systems: Fire Test Protocols for Fire-Extinguishing Systems. Submitted by Germany to the International Maritime Organization Subcommittee on Fire-Protection, 46th session, Agenda item 12.
Kidde Fire Protection. 2011. Fire Suppression System Engineered for Use with 3M™ Novec™ 1230 Fire Protection Fluid. Ref. 6351-5-05/11. Available online at http://www.kfp.co.uk/utcfs/ws-438/Assets/63515_Novec_System.pdf
Kucnerowicz-Polak, B. March 28, 2002. Halon sector update. Presented at the 19th Meeting of the Ozone Operations Resource Group, The World Bank, Washington, DC. R.S. Means Company, Inc. 2007. Means Square Foot Costs, 29th Annual Edition 2008. Kingston, MA: R.S. Means
Company, Inc. United Nations Environment Programme. 2001. Standards and Codes of Practice to Eliminate Dependency on Halons: Handbook of Good Practices in the Halon Sector. United Nations Publication ISBN 92-807-1988-1.
UNEP Division of Technology, Industry and Economics (DTE) under the OzonAction Programme under the Multilateral Fund for the Implementation of the Montreal Protocol, in cooperation with The Fire Protection Research Foundation. U.S. Department of Labor, Bureau of Labor Statistics. 2011. Consumer price index. Available online at http://www.bls.gov/cpi/ U.S. Environmental Protection Agency. 2004. Analysis of Costs to Abate International Ozone-Depleting Substance Substitute Emissions. EPA #40-R-04-006. Washington, DC: EPA. Available online at http://www.epa.gov/ozone/snap/emissions/downloads/ODSsubstituteemissions.pdf 5-154 Global Non-CO2 Greenhouse Gas Emissions Projections & Marginal Abatement Cost Analysis
SECTION 5 — SECTOR-LEVEL METHODS Werner, K., 3M. October 14, 2011. Personal communication with Pamela Mathis, ICF International.
Wickham, R. 2002. Status of Industry Efforts to Replace Halon Fire Extinguishing Agents. Stratham, NH: Wickham Associates. Available online at http://www.epa.gov/ozone/snap/fire/status.pdf
Wickham, R. 2003. Review of the Use of Carbon Dioxide Total Flooding Fire Extinguishing Systems. Stratham, NH: Wickham Associates. Available online at http://www.epa.gov/ozone/snap/fire/co2/ co2report2.pdf Global Non-CO2 Greenhouse Gas Emissions Projections & Marginal Abatement Cost Analysis 5-155
UNEP (2017a) reports total nonfeedstock HCFC production by country in ODP-weighted tons. As a result, nonfeedstock HCFC-22 production for these countries was assumed to be the total reported for each country in
UNEP (2017a) after “unweighting” the production estimates by HCFC-22’s ODP of 0.055. The ratio of nonfeedstock production to feedstock production was then used to estimate nonfeedstock HCFC-22 production to total HCFC-22 production, without exceeding the production capacities reported in the Chemical and Economics Handbook (IHS
Markit, 2001; Will et al., 2004; Jebens et al., 2014). The ratio of nonfeedstock production to feedstock production, 5-156 Global Non-CO2 Greenhouse Gas Emissions Projections & Marginal Abatement Cost Analysis
SECTION 5 — SECTOR-LEVEL METHODS as shown in Table 5-56, was estimated over the time series based on data for 1990 from EPA (2006) and data for 1996 and 2007 from Montzka et al. (2010) and by linearly interpolating the intervening years. The ratio of nonfeedstock production to feedstock production from 2008 through 2015 was assumed to be equal to the 2007 estimate from Montzka et al. (2010). Table 5-56: Portion of Total HCFC-22 Production That is Feedstock HCFC-22 Production for A1 Countries 1990 1995 2001 2002 2003 2004 2005 2006 2007–2015 This total was subtracted from western Europe production from Jebens et al. (2014) across the time series, and the remaining HCFC-22 production for western Europe is allocated to France, Germany, Italy, and the U.K. based on total HCFC-22 production capacity for each country as reported in Chemical and Economics Handbook (IHS Markit, 2001; Will et al., 2008; Will et al., 2004; Jebens et al., 2014). For all European countries, it was assumed that production from 1990 through 2003 could not exceed 2001-reported capacity, production in 2004 through 2006 could not exceed 2004-reported capacity, and production in 2007 through 2015 could not exceed 2013-reported capacity. Estimating Production in the Rest of the World Based on plant capacities from Will et al. (2004), HCFC production in Mexico, Argentina, Venezuela, and India was also only HCFC-22. Again, UNEP (2017a)-reported HCFC production was assumed to be the total nonfeedstock
HCFC-22 production reported for each country by “unweighting” the production estimates by dividing the total production by HCFC-22’s ODP of 0.055. For South Korea, 33% of total HCFC production capacity was HCFC-22 (Will et al., 2004, 2008; Jebens et al., 2014). This percentage was applied across the UNEP-reported nonfeedstock HCFC production time series to estimate nonfeedstock HCFC-22 production totals. The ratio of nonfeedstock production to feedstock production was then used to estimate nonfeedstock HCFC-22 production to total HCFC-22 production. For North Korea, UNEP (2017a) provided HCFC-22 production estimates for 2007 through 2015. Jebens et al. (2014) reported China’s HCFC-22 production for 2003 through 2013. HCFC-22 production was back casted using the ratio of total HCFC-22 production reported in Jebens et al. (2014) to UNEP-reported nonfeedstock HCFC production for 2003. This ratio was applied across the UNEP-reported time series for 1990 to 2002 and 2014 to estimate China’s HCFC-22 production for those years.
UNEP (2017b) reported HCFC-22 production in China for 2015. The ratio of nonfeedstock production to feedstock production across the time series for China and other Non-A1 countries and Russia is shown in Table 5-57. Table 5-57: Portion of Total HCFC-22 Production That is Feedstock HCFC-22 Production for Non-A1 Countries Countries 1990 1995 2000 2001 2002 2003 2004 2005 2006 2007–2015 Non-A1 China Projected
METHODOLOGY DOCUMENTATION used for 2015 through 2020 (UNFCCC, 2017a). Emission trends were used to project HFC-23 emissions for the remainder of the time series (2025 through 2050). For all other A1 countries, the dispersive production and feedstock production portion of emissions were projected separately to account for the decline in the production for dispersive purposes because of the phase-out requirements of the Montreal Protocol. The following assumptions for these countries were applied to estimate dispersive production:
UNFCCC reported zero emissions of HFC-23 for Australia and Canada, beginning in 2000 and 1995, respectively (UNFCCC, 2017b). No further data were available on Australia, so the EPA assumed Australia will not produce HCFC-22 in the future. Jebens et al. (2014) reports that Canada only produces one HCFC,
HCFC-123, so it was assumed that Canada will not produce HCFC-22 in the future. For Greece and the U.K., HCFC-22 production was assumed to end due to plant closures in 2006 and 2008, respectively, and therefore emissions were set equal to zero. For Spain, HCFC production has not been reported to UNEP since 2011, so it was assumed that nonfeedstock production of HCFC-22 ended. For developed countries other than Australia, Canada, the U.K., and Spain, emissions from nonfeedstock production were assumed to decrease linearly from 2015 so that no emissions resulted from HCFC-22 nonfeedstock production by the 2020 phase-out date under the Montreal Protocol. To project the feedstock production portion of HFC-23 emissions for developed countries, a 5% global growth rate of feedstock HCFC-22 production as reported in Montzka et al. (2010) was applied for all countries.
HCFC-22 dispersive production for developing countries was projected using a 2010 HCFC-22 production estimate of 395,000 metric tons, as provided by Miller and Kuijpers (2011), and a baseline estimate of 383,000 metric tons and the percentage reductions from that baseline as prescribed by the accelerated phase-out schedule of the Montreal Protocol.
SECTION 5 — SECTOR-LEVEL METHODS operation. In 2013, the EU Emissions Trading System, New Zealand, and Australia imposed a ban on the use of Certified Emission Reduction credits from HFC-23 destruction, which significantly lowered the value of credits obtained from HFC-23 abatement projects. Signed in 2016, the Paris Agreement universally rejects HFC-23 projects for offset credits. Several facilities with CDM projects are no longer destroying
France, and Italy and 75% in the U.K. (Harnisch and Hendriks, 2000). Except for the U.K., these levels were assumed to be maintained through 2050. In 2005, the baseline market penetration of thermal oxidation in the U.K. was estimated to be 87.5%. This was intended to reflect the 2005 commissioning of a thermal oxidizer at the one U.K. plant that had not had one previously (Campbell, 2006). For 2006 through 2008, the level of baseline market penetration in the U.K. was estimated to be 100%. No emissions were estimated for the U.K. after 2008 as a result of two
HCFC-22 plants closings in 2008 (MacCarthy et al., 2010). In 2005, the baseline market penetration of thermal oxidation in the Netherlands was assumed to be 100%. Uncertainty In developing these emission estimates, the EPA made use of multiple international datasets, country-specific information on abatement levels (where available), and the 2006 IPCC Guidelines on estimating emissions from this source. Nevertheless, uncertainties exist in both the activity data and the emission rates used to generate these emission estimates. Although the EPA used four separate sources to estimate country-by-country production of HCFC-22 (UNEP-reported, country-specific HCFC production, country-by-country production capacities from the The assumption of 95% destruction efficiency is conservative. Although reduction efficiency is closer to 99.99% for incineration, a lower reduction efficiency takes into account startups, shutdowns (e.g., for cleaning), and malfunctions. Global Non-CO2 Greenhouse Gas Emissions Projections & Marginal Abatement Cost Analysis 5-159
METHODOLOGY DOCUMENTATION less expensive than the cost of installation at existing plants. This analysis used a capital cost for new facilities that is approximately 23% less than the cost of installation at existing facilities (Irrgang, 2018). 5.2.9.6 References
Campbell, N., Arkema. 2006. Personal communication with Deborah Ottinger Schaefer of EPA, April 24, 2006.
Harnisch, J. and C. Hendricks. April 2000. Economic Evaluation of Emission Reductions of HFCs, PFCs and SF6 in Europe. Contribution to the study Economic Evaluation of Sectoral Emission Reduction Objectives for Climate Change. Commission of the European Union, Directorate General Environment.
IHS Markit. 2001. CEH Marketing Research Report: Fluorocarbons. Chemical and Economics Handbook.
Irrgang, G., Selas Linde. June 11, 2018. Personal communication with Rebecca Ferenchiak, ICF. Information provided by Mr. Rost to Ms. Ottinger in 2006 confirmed by Mr. Irrgang and adjusted for inflation.
Jebens, A., T. Kalin, Y. Yamaguchi, and Y. Zhang. 2014. CEH Marketing Research Report: Fluorocarbons. Chemical Economics Handbook—IHS Chemical.
Thomson. 2010. UK Greenhouse Gas Inventory, 1990 to 2008: Annual Report for Submission under the Framework Convention on Climate Change. AEA: Oxfordshire, UK.
Salameh, J. Mühle, R.F. Weiss, R.G. Prinn, R.H.J. Wang, S. O’Doherty, B.R. Greally, and P.G. Simmonds. 2010.
Miller, B.R. and L.J.M. Kuijpers. 2011. Projecting Future HFC-23 emissions. Atmospheric Chemistry and Physics,
Discussion, 11, 23081-23102. Montzka, S.A., L. Kuijpers, M.O. Battle, M.A.K. Verhulst, E.S. Saltzman, and D.W. Fahey. 2010. Recent increases in global HFC-23 emissions. Geophysical Research Letters, 37, L02808.
Rand, S., D. Ottinger, and M. Branscome. May 26–28, 1999. Opportunities for the Reduction of HFC-23 Emissions from the Production of HCFC-22. IPCC/TEAP Joint Expert Meeting. Petten, Netherlands.
Rost, M., T-thermal. April 24, 2006. Personal communication with Debora Ottinger, EPA.
United Nations Environment Programme. 2017a. Data Access Centre. HCFC Production. Available online at http://ozone.unep.org/Data_Reporting/Data_Access/
United Nations Environment Programme. 2017b. Executive Committee of the Multilateral Fund for the Implementation of the Montreal Protocol: Seventy-eight Meeting–Key Aspects Related to HFC-23 By-Product Control Technologies. Available online at www.multilateralfund.org/78/English/1/7809.docx U.S. Environmental Protection Agency. 2006. Global Anthropogenic Non-CO2 Greenhouse Gas Emissions: 1990– 2020. Office of Atmospheric Programs: Climate Change Division. Available online at http://www.epa.gov/ climatechange/economics/international.html
National Communications. 2010. Fifth National Communications – Annex I. Available online at: https://unfccc.int/process-and-meetings/transparency-and-reporting/reporting-and-review-under-theconvention/national-communications-and-biennial-reports-annex-i-parties/national-communicationsubmissions/fifth-national-communications-annex-i
Will, R., A. Kishi, and S. Schlag. 2004. CEH Marketing Research Report: Fluorocarbons. Chemical Economics Handbook. SRI Consulting.