PHOENIX, at the ATMOsphere 2012 conference, Washington, DC. Available online at http://www.atmo.org/media.presentation.php?id=139
Hinde, D., S. Zha, and L. Lan. February 2009. Carbon dioxide in North American supermarkets. ASHRAE Journal, 51.
Honeywell. 2014. Genetron Performax® LT (R407F): first choice solution for commercial refrigeration. Available online at http://www.honeywell-refrigerants.com/europe/wp-content/uploads/2014/02/Performax-LT-4pp130204-low-res.pdf Hydrocarbons21. December 3, 2017. Are home fridges in U.S. turning toward hydrocarbons? Available online at http://hydrocarbons21.com/articles/8018/are_home_fridges_in_u_s_turning_toward_hydrocarbons_ Hydrocarbons21. February 2019. Petra converting HVAC production lines to R290. Available online at http://hydrocarbons21.com/articles/8839/petra_converting_hvac_production_lines_to_r290 Hydrocarbons21. March 18, 2016. Hoshizaki ice makers to go all natural by 2018. Available online at http://hydrocarbons21.com/articles/6925/hoshizaki_ice_makers_to_go_all_natural_by_2018
ICF International. 2008. Regulatory Impact Analysis (RIA) of Current Section 609 Requirements and Potential Updates: Draft Report. Washington, DC: ICF International. Intergovernmental Panel on Climate Change. 2005. IPCC/TEAP Special Report on Safeguarding the Ozone Layer and the Global Climate System: Issues Related to Hydrofluorocarbons and Perfluorocarbons. In B. Metz, L. Kuijpers, S. Solomon, S.O. Andersen, O. Davidson, J. Pons, et al. (Eds.). Prepared by Working Groups I and III of the IPCC, and the Technical and Economic Assessment Panel. New York, NY: Cambridge University Press.
Koban, M. April 2009. HFO-1234yf low GWP refrigerant LCCP analysis. Presented at SAE 2009 World Congress.
Linde Gas. 2014. R407A: lower global warming potential replacement for R404A. Available online at https://www.linde-gas.com/en/images/R407A-Refrigerant-Brochure_tcm17-114449.pdf
Malvicino, C. Centro Ricerche Fiat 2008. The 4 Fiat pandas experiment and other considerations on refrigerants. Presented at the SAE Alternative Refrigerant Systems Symposium, Phoenix, AZ. National Resource Defense Council. November 2014. Hydrocarbon room air conditioners: Energy-efficient, commercially viable and safe. Available online at https://www.nrdc.org/experts/avinash-kar/hydrocarbonroom-air-conditioners-energy-efficient-commercially-viable-and-safe Global Non-CO2 Greenhouse Gas Emissions Projections & Marginal Abatement Cost Analysis 5-127
METHODOLOGY DOCUMENTATION Oko-Recherche, Oko-Institute, HEAT International, Danish Technological Institute, Re-phridge, Karlsruhe University of Applied Sciences, Estonia Environmental Research Centre, and Ammonia Partnership. September 2011. Preparatory Study for a Review of Regulation (EC) No 842/2006 on Certain Fluorinated Greenhouse Gases. Prepared for the European Commission.
Pham, H. and H. Sachs. 2010. Next Generation Refrigerants: Standards and Climate Policy Implications of Engineering Constraints. ACEEE Summer Study on Energy Efficiency in Buildings. Available online at http://www.aceee.org/files/proceedings/2010/data/papers/1933.pdf Proud Green Building. May 2016. New window air conditioning units using more sustainable refrigerant. Available online at https://www.proudgreenbuilding.com/news/new-window-air-conditioning-units-using-moresustainable-refrigerant/ R744. December 18, 2012. Cascade CO2 could be winning option in emerging economies—CCAC Forum, Part I18. Available online at http://www.r744.com/news/view/3755 R744. January 24, 2019b. Lennox to launch CO2 condensing unit. Available online at http://www.r744.com/articles/8810/lennox_to_launch_co2_condensing_unit R744. March 2019a. GreenChill reports growth in CO2 systems at U.S. supermarkets. Available online at http://www.r744.com/articles/8926/greenchill_reports_growth_in_co2_systems_at_u_s_supermarkets Refrigeration and Air Conditioning (RAC) Magazine. January 7, 2013. US car giant GM publicly backs HFO-1234yf. Available online at http://www.racplus.com/news/us-car-giant-gm-publicly-backs1234yf/8640815.article?blocktitle=Latest-news&contentID=2332
Refrigeration, Air Conditioning and Heat Pumps Technical Options Committee. 2011. 2010 Assessment. Nairobi:
UNEP. Available online at http://ozone.unep.org/teap/Reports/RTOC/RTOC-Assessment-report-2010.pdf
Russian Federation. 1994. Achievable ODS Phase-out Schedule in the Russian Federation. Available online at: http://documents.worldbank.org/curated/pt/326351468776405093/pdf/multi0page.pdf
Shecco. 2012. 2012: Natural refrigerants market growth for Europe.
Shen, B., O. Abdelaziz, and L. Liudahl. 2016. Assessment of DR-55 as a drop-in replacement for R410A. International Refrigeration and Air Conditioning Conference. Paper 1708. Available online at https://pdfs.semanticscholar.org/5c1a/db29505534d9686e9560c7e0410118dea129.pdf
Stanga, M. December 13, 2012. Correspondence: cost of R-32 for unitary AC equipment.
Supermarket News. 2012. Refrigeration systems chillin’ with carbon dioxide. Available online at http://supermarketnews.com/technology/refrigeration-systems-chillin-carbondioxide?page=1showtext.cfm?t=ptb0810 Technology and Economic Assessment Panel. 2012. Decision XXIII/9 Task Force Report: Additional Information on Alternatives to Ozone-Depleting Substances.
Thermo King. 2014. Refrigerant Conversion Guide. Available online at http://thermoking.ipublishpro.com/119135919RefrGuideEN/ib/pdf.pdf U.S. Department of Agriculture. 2017. International Macroeconomic Data Set. Accessed November 2017. Available online at https://www.ers.usda.gov/data-products/international-macroeconomic-data-set/internationalmacroeconomic-data-set/. #Baseline Data Files.%20 U.S. Environmental Protection Agency and National Highway Traffic Safety Administration. 2011. Draft Joint Technical Support Document: Proposed Rulemaking for 2017–2025 Light-Duty Vehicle Greenhouse Gas Emission Standards and Corporate Average Fuel Economy Standards. U.S. Environmental Protection Agency. 2017. Vintaging Model. Version VM IO file_v4.4_02.22.17.xls. U.S. Environmental Protection Agency. May 1998. Draft Regulatory Impact Analysis: The Substitutes Recycling Rule. Prepared by ICF Incorporated for U.S. Environmental Protection Agency. Washington, DC: ICF International. 5-128 Global Non-CO2 Greenhouse Gas Emissions Projections & Marginal Abatement Cost Analysis
SECTION 5 — SECTOR-LEVEL METHODS United Nations Environment Programme. 2012. Report of the Technology and Economic Assessment Panel, Additional Information on Alternatives to Ozone Depleting Substances. Decision XXIII/9 Task Force Report. Available online at https://ozone.unep.org/science/assessment/teap?page=1
United Nations Environmental Programme. 2017a. Overall Analysis of the Results of the Surveys of ODS Alternatives (Decision 79/42(C)). Executive Committee of the Multilateral Fund for the Implementation of the Montreal Protocol. Eightieth Meeting. Montreal, 13-17 November 2017. Available online at http://www.multilateralfund.org/80/Document%20Library1/1/8054.pdf
United Nations Environment Programme. 2017b. Production and Consumption of Ozone Depleting Substances, 1986-2016. United Nations Environment Programme (UNEP) Ozone Secretariat. Available online at http://ozone.unep.org/reporting/
United Nations Environment Programme. 2018. OzonAction Kigali Fact Sheet No. 17—Refrigerant Trends in Mobile Air-Conditioning. Available online at https://wedocs.unep.org/bitstream/handle/20.500.11822/26651/7946FS17MACSector.pdf?sequence=1&isAll owed=y WalMart. September 2006. DOW Case Study: Secondary Loop Refrigeration and DOWFROSTTM Fluid Contribute to Wal-Mart “Green Initiative.”
Wang, K., M. Eisele, Y. Hwang, and R. Radermacher. October 2010. Review of secondary loop refrigeration systems. International Journal of Refrigeration, 33(2), 212-234.
Xu, X., Y. Hwang, and R. Radermacher. July 16–19, 2012. Performance measurement of R32 in vapor injection heat pump system. Presented at the International Refrigeration and Air Conditioning Conference at Purdue. Global Non-CO2 Greenhouse Gas Emissions Projections & Marginal Abatement Cost Analysis 5-129
METHODOLOGY DOCUMENTATION machines because of the associated economic, occupational, and environmental benefits (i.e., reduced emissions) (Durkee, 1997). Likewise, many European countries have imposed stringent environmental and safety regulations that require the lowest level of emissions attainable by solvent degreasing equipment. Retrofit techniques were either already implemented or simply not required if the user had purchased new emission-tight vapor degreasers.
Consequently, this analysis assumed that end users in the United States and developed countries have already adopted these controls and that any emissions from these facilities cannot be further abated by this option. In contrast, solvent users in Non-A1 (i.e., developing) countries were assumed to not have retrofitted their equipment but may consider the equipment retrofit option, because updating their equipment may be preferred over investing in entirely new units. Capital Cost: To retrofit equipment, significant upgrades must be made. One-time costs were based on the assumption that a user chooses to retrofit their equipment through increasing freeboard height, installing a cover, and installing a freeboard refrigeration device. Based on these upgrades, one-time costs were assumed to be $24,500 (Durkee, 1997). Annual O&M Costs: No annual costs are associated with this abatement option. Annual Revenue: Annual savings are associated with the avoided consumption of HFC that results from a reduction in emissions. An annual cost savings of almost $4,500 was assumed based on the assumed reduction in emissions of 250 pounds per year of HFCs that would otherwise need to be replaced.
Ultrasonic, 2008). Therefore, the cost of replacing an HFC-containing cleaning system with an aqueous system was based on the initial investment in tanks, equipment, and space (Beeks, 2008). This analysis assumed a one-time cost of $50,000 for the investment in the equipment and the additional space needed for that equipment (Owens, 2008). Annual O&M Costs: The major operating costs for an aqueous system are associated with the cost of energy and the cost of the continuous flow of de-ionized water (Crest Ultrasonic, 2008). An annual cost of $7,400 was used to represent energy and water consumption costs; this cost was based on consumption of 9 kilowatt (kW) per day and $10 worth of de-ionized water per day (Owens, 2008). Annual Revenue: Annual savings were based on the savings associated with not using an HFC-based cleaning system. An annual savings of $6,700 was used to represent energy and HFC solvent cleaner costs associated with using a retrofitted HFC-based cleaning system, while an annual savings of $11,200 was used to represent energy and HFC solvent cleaner costs associated with using a nonretrofitted HFC-based cleaning system; this savings was based on consumption of 4 kW per day and 250 to 500 pounds of HFC lost per year (Owens, 2008; Durkee, 1997).
SECTION 5 — SECTOR-LEVEL METHODS Capital Cost: Compared with aqueous systems, semi-aqueous systems often require an extra tank or two as well as the need for ventilation. Therefore, semi-aqueous systems were assumed to be slightly higher in cost than aqueous systems (Crest Ultrasonic, 2008). Additionally, vapor degreasers are not suitable for retrofit to semi-aqueous cleaning processes (Crest Ultrasonic, 2008). Therefore, the cost of replacing an
Beeks, M., Brulin & Company, Inc. October 2008. Personal communication with Emily Herzog and Mollie Averyt,
ICF International. Crest Ultrasonic. September/October 2008. Personal communication between Eric Larson of Crest Ultrasonics and Emily Herzog, ICF International.
Durkee, J.B. November 12–13, 1997. Chlorinated solvents NESHAP—results to date, recommendations and conclusions. Presented at the International Conference on Ozone Layer Protection Technologies, Baltimore,
ICF Consulting, October 7, 2003. Personal communication between solvent industry experts and William Kenyon,
ICF Consulting. Owens, J., 3M. August 2008. Personal communication with Emily Herzog, ICF International.
Owens, J.G., P.E., 3M Performance Materials. October 27, 2003. Written correspondence with Mollie Averyt and Marian Martin Van Pelt, ICF Consulting. Global Non-CO2 Greenhouse Gas Emissions Projections & Marginal Abatement Cost Analysis 5-135
HCFO-1233zd(E) in Commercial Refrigeration This option replaces HFC-245fa used in commercial refrigeration foam with unsaturated HCFCs or HCFOs, namely HCFO-1233zd(E). HCFO-1233zd(E) has a GWP of 4.7 to 7 (EPA, 2012). Unsaturated HFCs and HCFCs with low GWPs have emerged in the market on a commercial scale as alternative blowing agents in various foam applications over the last several years. This abatement option was applied to a facility that manufactures 50,000 units annually, with each unit containing 1.4 kilograms of blowing agent. This option is applicable to HFC-245fa in newly manufactured commercial refrigeration equipment in the EU. 5-136 Capital Costs: HCFO-1233zd(E) is very similar to HFC-245fa, such that existing manufacturing equipment requires little to no change to achieve the desired operational characteristics. Therefore, no one-time costs were assumed. Annual O&M Costs: Annual costs were assumed to be a result of the incremental cost of the blowing agent replacement, which is approximately $4/kg for HCFO-1233zd(E) relative to HFC-245fa (UNEP, 2012). Annual Revenue: No annual savings were assumed. Global Non-CO2 Greenhouse Gas Emissions Projections & Marginal Abatement Cost Analysis
HFC-134a and HFC-245fa in low-pressure (LP), two-component spray foam (i.e., frothing insulation and sealant). The abatement option was assumed to be a blowing agent blend of HFO-1234ze(E) and HCFO-1233zd(E), with the same composition as the respective gaseous and liquid HFC blowing agent components assuming a 1:1 replacement ratio. This abatement option was applied to a facility that manufactures 2.1 million pounds of LP two-component PU spray foam using HFC-134a/HFC-245fa blowing agent annually (Dow, 2018).72 It was assumed that the foam formulation is 17% by weight blowing agent (Dow, 2018), so the facility uses 350,000 pounds of blowing agent annually. This option is applicable to HFC-134a and HFC-245fa in newly manufactured LP two-component spray foam products in developed countries, except the EU. Capital Costs: Capital costs for transitioning to HFO-1234ze(E)/HCFO-1233zd(E) blowing agent are estimated to be up to $2 million per facility (i.e., $1 million for equipment modifications and $1 million for manufacturing plant upgrades to handle flammable material [BASF, 2014; Dow, 2018]). HFO-1234ze(E) is mildly flammable, so the manufacturing plant will need to be upgraded to accommodate the use of flammable material. These upgrades include safety modifications such as new leak detection monitors, new holding tanks for raw material with containment barriers, and ventilation (BASF, 2014; Dow, 2018).
Furthermore, the electrical classification must be upgraded for all equipment, such as mixing tanks, motors, light switches, and light fixtures (Dow, 2018). Costs depend on the size, layout, and existing equipment in the plant (BASF, 2014). Standard spraying equipment at end use was also assumed to be used for this abatement option (UNEP, 2008). Conversion Costs: Conversion costs include foam reformulation, product development, certifications, shelf-life studies, field and external testing, and commercialization (American Chemistry Council Center for Polyurethanes Industry [ACC CPI], 2014; BASF, 2014; Clayton Corporation, 2014; Dow, 2014; Fomo
Products, 2014; RHH, 2014). Reformulation includes studying, optimizing, and testing the new foam product and requires third-party testing approvals, internal manufacturer or customer standards, the use of third-party testing, and iterative research and development (ACC CPI, 2014). New products must be tested to meet internal quality controls, dimensional stability, voluntary performance standards, and/or mandatory standards and regulations. The tests verify performance metrics such as thermal performance, fire safety, and other life and safety requirements (ACC CPI, 2014; BASF, 2014). Conversion costs are estimated to be several million dollars (BASF, 2014). For the purposes of this analysis, conversion costs were assumed to be $3 million. Annual O&M Costs: Annual O&M costs include labor, energy, and training. Annual O&M costs for HFO1234ze(E)/HCFO-1233zd(E) in LP two-component PU spray foam are expected to be the same as with
HFC-134a/HFC-245fa. Additional training required to handle flammable material is not expected to be significantly different (i.e., may add one to two hours per employee [Dow, 2018]). Thus, the only annual incremental cost increase is due to the price differential between the blowing agents, which is approximately $7.5/kg for HFO-1234ze(E) relative to HFC-134a and $4/kg for HCFO-1233zd(E) relative to
HFC-245fa (UNEP, 2012). Annual Revenue: Because the alternative blowing agents are more expensive on a mass basis than HFC134a/HFC-245fa, no annual cost savings are associated with this option. Cost savings associated with the 72 This estimate was calculated using blowing agent consumption for the spray foam market in the United States modeled in
HC blowing agent. HCs are inexpensive and have very low direct GWPs. Technical issues exist with using HCs, such as flammability and lower insulation performance, but these can be overcome through proper safety controls and engineering design (EPA, 2009). A significant advantage of HCs is that they can be easily blended to affect a range of properties, such as thermal performance, cell gas pressure, and foam density, as well as cost (UNEP, 2012).
Russell, Vice President, Plastics Division, CPI, ACC, for Docket ID No. EPA-HQ-OAR-2014-0198, Protection of stratospheric ozone: change of listing status for certain substitutes under the significant new alternatives policy program. Federal Register. Vol. 79. 46,126 (Aug. 6, 2014). Available online at https://www.regulations.gov/document?D=EPA-HQ-OAR-2014-0198-0175
BASF Corporation. October 17, 2014. Comments of BASF Corporation on US EPA’s Proposal to Change the Listings from Acceptable to Unacceptable for HFC–134a, HFC–245fa, HFC–365mfc, and Any Blends Containing These Blowing Agents for All Foam End-Uses and Applications Except for Spray Foam as of January 1, 2017. Available online at https://www.regulations.gov/document?D=EPA-HQ-OAR-2014-0198-0093
Clayton Corporation. 2014. Comment submitted by Clayton Corporation for Docket ID No. EPA-HQ-OAR-20140198, Protection of stratospheric ozone: change of listing status for certain substitutes under the significant new alternatives policy program. Federal Register. Vol. 79. 46,126 (Aug. 6, 2014). October 20, 2014. Available online at https://www.regulations.gov/document?D=EPA-HQ-OAR-2014-0198-0133 Dow Chemical Company. October 17, 2014. Comment submitted by the Dow Chemical Company for Docket ID No.
EPA-HQ-OAR-2014-0198, Protection of stratospheric ozone: change of listing status for certain substitutes under the significant new alternatives policy program. Federal Register. Vol. 79.46,126 (Aug. 6, 2014). Available online at https://www.regulations.gov/document?D=EPA-HQ-OAR-2014-0198-0204 Dow Chemical Company. August 7, August 29, September 28, and October 10, 2018. Personal communication regarding foam abatement option assumptions between Dow (Lisa Massaro and Kristie Murray), EPA (Dave Godwin), and ICF (Kasey Knoell). Extruded Polystyrene Foam Association. October 20, 2014. Comment submitted by John Ferraro, Executive
Director, XPSA, for Docket ID No. EPA-HQ-OAR-2014-0198, Protection of stratospheric ozone: change of listing status for certain substitutes under the significant new alternatives policy program, Federal Register. Vol. 79. 46,126 (Aug. 6, 2014). Available online at https://www.regulations.gov/document?D=EPA-HQ-OAR-20140198-0189 Extruded Polystyrene Foam Association. September 17, 2018. Personal communication regarding foam abatement option assumptions between EPA (Dave Godwin) and XPSA (John Heinze). Fomo Products, Inc. October 17, 2014. Comment submitted by Dr. Thomas Fishback, Vice President, Research and
Development, Fomo Products, Inc., for Docket ID No. EPA-HQ-OAR-2014-0198, Protection of stratospheric ozone: change of listing status for certain substitutes under the significant new alternatives policy program. Federal Register. Vol. 79. 46,126 (Aug. 6, 2014). Available online at https://www.regulations.gov/document?D=EPA-HQ-OAR-2014-0198-0139 Owens Corning. October 20, 2014. Comment submitted by Greg Mather, Vice President and General Manager Foam Insulation Building Materials Group, Owens Corning, for Docket ID: No. EPA-HQ-OAR-2014-0198, Protection of stratospheric ozone: change of listing status for certain substitutes under the significant new alternatives policy program. Federal Register. Vol. 79. 46,126 (Aug. 6, 2014). Available online at https://www.regulations.gov/document?D=EPA-HQ-OAR-2014-0198-0085 5-142 Global Non-CO2 Greenhouse Gas Emissions Projections & Marginal Abatement Cost Analysis
SECTION 5 — SECTOR-LEVEL METHODS RHH Foam Systems, Inc. October 20, 2014. Comment submitted by Peter J. Bartell, Vice President/Co-Owner, RHH Foam Systems, Inc., for Docket ID: No. EPA-HQ-OAR-2014-0198, Protection of stratospheric ozone: change of listing status for certain substitutes under the significant new alternatives policy program. Federal Register. Vol. 79. 46,126 (Aug. 6, 2014). Available online at https://www.regulations.gov/document?D=EPA-HQ-OAR2014-0198-0112
Russell, R. April 2005. Personal communication regarding foam production costs between ICF and Robert Russell. United Nations Environment Programme. June 2008. Revised analysis of relevant cost considerations surrounding the financing of HCFC phase-out (Decisions 53/37(I) and 54/40). 55th Meeting of the Executive Committee of the Multilateral Fund for the Implementation of the Montreal Protocol. Available online at http://www.multilateralfund.org/sites/55th/Document%20Library2/1/5547.pdf
United Nations Environment Programme. 2012. Report of the Technology and Economic Assessment Panel (TEAP) Decision XXIII/9 Task Force Report Additional Information on Alternatives to Ozone Depleting Substances. Available online at http://ozone.unep.org/Assessment_Panels/TEAP/Reports/TEAP_Reports/teap-task-forceXXIII-9-report-may2012.pdf U.S. Environmental Protection Agency. October 30, 2009. 2009 Marginal Abatement Cost Curve Analysis for Reduction of HFCs in Traditional Ozone Depleting Substance (ODS) End-Use Applications: Draft Report. Prepared by ICF International. U.S. Environmental Protection Agency. August 10, 2012. Protection of stratospheric ozone: determination 27 for significant new alternatives policy program. Federal Register. Vol. 77, No. 155. Available online at http://www.gpo.gov/fdsys/pkg/FR-2012-08-10/pdf/2012-19688.pdf Global Non-CO2 Greenhouse Gas Emissions Projections & Marginal Abatement Cost Analysis 5-143
MDIs, the abatement measure examined by this analysis is further use of dry powder inhaler (DPI) technology where suitable for the patient. Costs were analyzed based on a single DPI compared with a single MDI, with estimated cost data that incorporate the cost associated with avoided use of HFC-134a propellant, the increase in the cost of DPI treatment, the cost to market the new treatment, and the cost to retrain patients in using the DPI (Ecofys, 2000; Enviros, 2000). Table 5-50 summarizes the applicability of each abatement option to the aerosol emission categories. The subsequent subsections describe each abatement option in more detail. Table 5-50: Aerosol Product Use Abatement Options Reduction Efficiency Abatement Option Consumer Aerosol Facility/