Policy Replication

Damage Case Compendium Technical Support Document, Volume IIa: Potential Damage Cases - DCN SE04459

Docket document2015-11-03 · EPA · report · EPA-HQ-OW-2009-0819-5768
RIN 2040-AG41, RIN 2040-AF77, RIN 2040-AF14, RIN 2040-AG54, RIN 2040-AG48, RIN 2040-AG23, RIN 2040-AF76 · Docket EPA-HQ-OW-2009-0819

Other documents for the same rulemaking

2009-10-29 Docket documentSteam Electric Power Generating Point Source Category: Final Detailed Study Report [EPA 821-R-09-008] [DCN 00003]
2009-10-29 Docket documentSupporting Statement for the Draft Questionnaire for the Steam Electric Power Generating Effluent Guidelines Information Collection Request [DCN 00001]
2009-10-29 Docket documentDraft Questionnaire for the Steam Electric Power Generating Effluent Guidelines [DCN 00002]
2009-10-29 Docket documentAgency Information Collection Activities; Proposed Collection; Comment Request; Proposed Information Collection Request for the Steam Electric Power Generating Effluent Guidelines; EPA ICR No. 2368.01, OMB Control No. 2040-NEW
2009-12-30 Docket documentLetter to Peter Silva, USEPA from Elizabeth E. Aldridge, Hunton and Williams L.L.P on behalf of the Utility Water Act Group (UWAG) [DCN SE00112]
2009-12-31 Docket documentLetter to Elizabeth E. Aldridge, Hunton and Williams, LLP from Peter S. Silva, Assistant Administrator, USEPA [DCN SE00113]
2010-03-09 Docket documentLetter to Ron Jordan, USEPA/Engineering and Analysis Division regarding USEPA Draft Steam Effluent Guidelines Questionnaire (November 17, 2009) [DCN SE00195]
2010-03-09 Docket documentLetter to Ron Jordan, USEPA/Engineering and Analysis Division regarding Comments on USEPA (February 1, 2010) [DCN SE00197]
2010-03-09 Docket documentEmail to Ron Jordan, USEPA/Engineering and Analysis Division regarding Steam Electric Power Generating EG - Proposed ICR Follow up Materials (January 20, 2010) [DCN SE00198]
2010-03-09 Docket documentLetter to Ron Jordan, USEPA/Engineering and Analysis Division regarding Ash Handling Systems Cost List (February 18, 2010) [DCN SE00200]
2010-03-09 Docket documentSupporting Statement for the Draft Questionnaire for the Steam Electric Power Generating Effluent Guidelines Information Collection Request (Part A) [DCN SE00205]
2010-03-09 Docket documentEmail to Ron Jordan, USEPA (February 19, 2010) [DCN SE00191]
2010-03-09 Docket documentEmail to Defenders of Wildlife, Sierra Club, Environmental Integrity, Earth Justice, and Natural Resources Defense Council [DCN SE00192]
2010-03-09 Docket documentEmail to Utility Water Act Group, American Public Power Association, and Edison Electric Institute [DCN SE00193]
2010-03-09 Docket documentEmail to Ron Jordan, USEPA dated February 3, 2010 [DCN SE00199]
2010-03-09 Docket documentAgenda and Example Flue Gas Desulfurization (FGD) Diagram for Discussion Between USEPA and Utility Water Act Group (UWAG) [DCN SE00201]
2010-03-09 Docket documentMemorandum to Steam Electric Record [DCN SE00204]
2010-03-09 Docket documentRon Jordan and Jezebele Alicea (February 25, 2010) [DCN SE00203]
2010-03-09 Docket documentEmail to Ron Jordan, US EPA (January 22, 2010) [DCN SE00190]
2010-03-09 Docket documentMemorandum to Ron Jordan, USEPA [DCN SE00206]
2010-03-09 Docket documentAgency Information Collection Activities; Submission to OMB for Review and Approval; Comment Request; Questionnaire for Steam Electric Power Generating Effluent Guidelines (NEW); EPA ICR No. 2368.01, OMB Control No. 2040-NEW
2013-06-07 Regulatory impact analysisRegulatory Impact Analysis For EPA’s Proposed RCRA Regulation Of Coal Combustion Residues (CCR) Generated by the Electric Utility Industry [DCN SE02969]
2013-06-07 Regulatory impact analysisTechnical Support Document: Calculating Benefit Per-Ton Estimates. Final Ozone NAAQS regulatory impact analysis [DCN SE03161]
2013-06-07 Regulatory impact analysisRegulatory Impact Analysis of the Clean Air Mercury Rule (EPA-452/R-05-003) [DCN SE03159]
2013-06-07 Regulatory impact analysisRegulatory Impact Analysis for the Industrial Boilers and Process Heaters NESHAP: Final Report (EPA-452/R-04-0020) [DCN SE03156]
2013-06-07 Regulatory impact analysisRegulatory Impact Analysis for the Proposed Effluent Limitations Guidelines and Standards for the Steam Electric Power Generating Point Source Category [DCN SE03170]
2013-06-07 Regulatory impact analysisFinal Regulatory Analysis: Control of Emissions from Nonroad Diesel Engines (EPA420-R-04-007) [DCN SE03157]
2013-06-07 Regulatory impact analysisQuality Assurance Project Plan (QAPP) for Economic Impact and Benefits Analysis for Steam Electric Rulemaking [DCN SE03376]
2013-06-07 Regulatory impact analysisList of Rulemaking Cost and Economic Impact Files: Steam Electric Effluent Guidelines Rulemaking [DCN SE03351]
2013-06-07 Docket documentEconomic Assessment of Damage Related to the Eagle Mine Facility [DCN SE03117]
2013-06-07 Docket documentRegulatory Impact Analysis for USEPA’s Proposed RCRA Regulation of Coal Combustion Residues (CCR) Generated by the Electric Utility Industry [DCN SE03168]
2013-06-07 Docket documentDocument submitted to initiate E.O. 12866 review - Steam Electric ELG NPRM FRN [DCN SE03884]
2013-06-07 Docket documentDocument submitted to conclude E.O. 12866 review - SteamElectricELG NPRM FRN - [DCN SE03958]
2013-06-07 Docket documentDocument of Changes Made During OMB Review Under E.O. 12866 - SteamElectric ELG NPRM FRN [DCN SE03972]
2013-06-07 Docket documentFishbase (version 07/2009) [DCN SE03047]
2013-06-07 Docket documentGuidance for Assessing Chemical Contaminant Data for Use in Fish Advisories, Volume 1 Fish Sampling Analysis, Third Edition [DCN SE01922]
2013-06-07 Docket documentDraft Human and Ecological Risk Assessment of Coal Combustion Wastes [DCN SE01834]
2013-06-07 Docket documentThe use of willingness-to-pay approaches in mammal conservation [DCN SE03191]
2013-06-07 Docket documentUsing the Basic Auto-validation Model to Assess the Effect of Environmental Quality on Texas Recreational Fishing Demand: Welfare Estimates [DCN SE03022]
2013-06-07 Docket documentNOAA National Marine Fisheries Service Southwest Regional Office, GIS Data [DCN SE03091]
2013-06-07 Docket documentSouthwest Fisheries Science Center Fisheries Biology Publications Database [DCN SE03134]
2013-06-07 Docket documentFinal report: Health Study to Assess the Human Health Effects of Mercury Exposure to Fish Consumed from the Everglades [DCN SE03152]
2013-06-07 Docket documentSTORET, EPA’s largest computerized environmental data system [DCN SE03160]
2013-06-07 Docket documentNational Recommended Water Quality Criteria [DCN SE03175]
2013-06-07 Docket documentNorth Florida Ecological Services Office Loggerhead Sea Turtle Caretta caretta [DCN SE03180]
2013-06-07 Docket documentNew Hampshire Clean Air Project Final Report Prepared for New Hampshire Public Utilities Commission [DCN SE02011]
2013-06-07 Docket documentFinal Site Visit Notes: Dominion Resources' Chesterfield Power Station [DCN SE00076]
2013-06-07 Docket documentMay 2011 National Industry-Specific Occupational Employment and Wages Estimates NAICS 221100 Electric Power Generation, Transmission and Distribution [DCN SE03221]
2013-06-07 Docket documentState Tax Rate Comparisons [DCN SE03229]
2013-06-07 Docket documentPopulation Estimates. National Population Datasets [DCN SE03241]
2013-06-07 Docket documentSustainable Financing Strategies [DCN SE03257]
2013-06-07 Docket documentAnnual Energy Outlook 2011 (AEO2011) [DCN SE03249]
2013-06-07 Docket documentEPA’s IPM Base Case v. 4.10 [DCN SE03265]
2013-06-07 Docket documentPlant Comments on Draft Kinder Morgan (Jackson Power Facility) Site Visit Notes [DCN SE00600]
2013-06-07 Docket documentFinal Engineering Site Visit Report for Georgia Power's Plant Yates [DCN SE02053]
2013-06-07 Docket documentNon CBI - Final Site Visit Notes: Appalachian Power Company's Mountaineer Plant [DCN SE02071]
2013-06-07 Docket documentNotes from Site Visit at the AES Cayuga Generation Plant on May 21, 2007 [DCN SE02061]
2013-06-07 Docket documentFinal Site Visit Notes: Tennessee Valley Authority’s Paradise Fossil Plant [DCN SE02101]
2013-06-07 Docket documentUWAG Draft Sampling Instructions for USEPA Collision Cell ICP-MS Methods Study [DCN SE00491]
2013-06-07 Docket documentPlant Comments to Belews Creek Sampling Episode Report, Revised SER [DCN SE01377]

References: 514 extracted, 0 linked to papers

Page 5Download these results: CSV · JSON
EPRI (2010), Area 1 installed toe-drain at base to capture water as it comes up near the base. Area 2 applies modified stormwater control methods to limit the amount of incidental ash in the perimeter ditch. The unlined landfill is inactive and the lined landfill is active. Remediation has been performed. According to EPRI (2010), a groundwater monitoring program is in place. In response to state requirement, monitoring is performed in the uppermost zone containing groundwater (the perched zone) rather than in the deeper drinking water aquifer. Post-remediation exceedances are limited to chloride and sulfate.270 Monitoring of three wells screened in a deeper groundwater aquifer was recently initiated and no exceedances were observed. This is so because the shale bedrock unit on which groundwater is perched is a confining unit that restricts downward migration to the deeper drinking water aquifer. Basis for Consideration as a Potential Damage Case: “The exceedances found at this site, primary MCLs for barium, chromium, cadmium, and lead and secondary MCLs for sulfate and chloride, are all confined to on-site wells. Therefore, this case is a potential damage case.”271 References
government reportNot linked to a paper · refsec
EA Engineering, Science, and Technology (2010): Biological and Chemical Monitoring in Turtle Creek Reservoir near Merom Generating Station, 2008. Final Report Prepared for Hoosier Energy Rural Electric
journal articleNot linked to a paper · refsec
Cooperative, Bloomington, Indiana, by EA Engineering, Science, and Technology, Deerfield, Illinois, March 2010. In Docket comment EPA-HQ-RCRA-2009-0640-10019. Asccessed Online October 2012.
journal articleNot linked to a paper · refsec
Earthjustice (2011): EPA’s Blind Spot: Hexavalent Chromium in Coal Ash. Lisa Evans, Earthjustice; Barb Gottlieb, Physicians for Social Responsibility; Lisa Widawsky, Jeff Stant, Abel Russ, John Dawes, Environmental Integrity Project, February 1, 2011. Accessed Online October 2012. http://earthjustice.org/sites/default/files/CoalAshChromeReport.pdf Hoosier Energy (2009): Hoosier Energy REC, Inc., Response to Request for Information under CERCLA Section 104(e), 42 U.S.C. 9604(e), March 28, 2009. Accessed Online January 2013. http://www.epa.gov/osw/nonhaz/industrial/special/fossil/surveys/hoosier-merom.pdf Louisville Public Hearing (2010): Public Hearing on EPA's Proposed Rule on Hazardous and Solid Waste Management System; Identification and Listing of Special Wastes; Disposal of Coal Combustion Residuals from Electric Utilities, DOCKET ID NO. EPA-HQ-RCRA-2009-0640, Louisville, Kentucky,
datasetNot linked to a paper · refsec · cited link
NIPSCO was about to launch, in early 2013, the construction of a scrubber at its MCGS, following state regulators' approval of the project in September 2012, to bring its electric generating stations into compliance with new U.S.
research reportNot linked to a paper · refsec
EPA rules on the emission of mercury and other HAPs. http://www.nwitimes.com/business/nipsco-gets-ok-to-startmillion-michigan-city-project/article_46f3ac34-8874-583a-9c7c-c4c0418e9878.html. This project is the outcome of the January 2011 legal deal brokered by the EPA and the DOJ with NIPSCO and other utilities in the Midwest, along the southern shore of Lake Michigan. As part of the settlement, NIPSCO committed to permanently scuttle an idled coal-fired power plant in Gary and spend $600 million to install and improve pollution controls at three other aging electric generators in Chesterton, Michigan City and Wheatfield. (http://www.epa.gov/oecaerth/resources/decrees/civil/caa/nipsco-cd.pdf; for a summary, see http://www.chicagotribune.com/news/local/breaking/chibrknews-deal-would-clear-up-coalplant01132011,0,4399852.story). The settlement also calls for installation of new flue gas desulfurization (FGD) and an upgrade to existing selective catalytic reduction systems at the MCGS. The FGD installation project is scheduled for completion by the end of 2015 (http://insurancenewsnet.com/oarticle/2013/11/05/nisource-posts-third-quarter-2013earnings-%5Bprofessional-services-close--up%5D-a-415620.html). According to NIPSCO (September 2009), the fly ash from the Bailly and Michigan City Stations is transported for disposal to Schafer Generating Station in
government reportNot linked to a paper · refsec · cited link
Wheatfield, about 20 miles south of Valparaiso. http://www.citybythelake.org/forums/lofiversion/index.php?t2533.html According to NIPSCO (2010) and GZA GeoEnvironmental (2012, narrative and Figures 1 and 2), there are presently three primary ponds and three secondary ponds, all unlined: Primary #1: 2.2 acres, capacity 57,250 cubic yards (CY); Primary #2: 2.6 acres, capacity 70,260 CY; and Bottom Ash Pond (Bottom Ash Area, BAA, which does not retain/impound water): 0.7 acres, capacity 2296 CY). The secondary (polishing ponds) are: Secondary #1: 0.2 acres, capacity 4440 CY; Secondary #2: 0.2 acres, capacity 5344 CY; and Final Settling Basin (Final Settling Pond,
research reportNot linked to a paper · refsec · cited link
FSP): 5.7 acres, capacity 137361 CY. In addition, there are also areas of historic fill that used to receive slurried CCRs. The impoundments were constructed in the early 1970’s for the purpose of storing and disposing CCRs and began operation in 1973. Prior to 1973, fly ash was used as structural fill to fill in the shoreline of Lake Michigan. In 1999, the MCGS switched to a dry fly ash handling system. There are two rows of sheet piling that separate the impoundments from Lake Michigan. The northernmost row (installed between 1935 and 1950) was primarily installed to protect the MCGS from wave erosion. The second row of sheet piling was installed in 1973 in conjunction with the impoundments to support the structural integrity of the impoundments and for further protection from Lake Michigan. Heavy rip rap was placed in between the two rows of sheet piling. The MCGS is located about one mile northwest of Michigan City, Indiana (101 Wabash Street, Michigan City, Indiana 46360). The impoundments are located less than a mile southwest of the MCGS. For a succinct review of the morphology and the Pleistocene to Holocene geology of the southern shore of Lake Michigan, see KellerLynn (2010) and references therein.
research reportNot linked to a paper · refsec
Golder Associates (2012). IIa. CCR Damage Case Reassessment December 2014 The MCGS’ site borings are consistent with the regional geology. The soil sequence is dominated by massive, very stiff silt and clay, but contains numerous lenses of fine and/or silty sand particularly in the
research reportNot linked to a paper · refsec
PDWS). While no wells were placed off-site, Dames & Moore (1982) concluded that a steel slurry wall down-flow from the disposal site, in addition to natural attenuation, mitigated and limited the contaminant plume. Because lead exceeding the PDWS was detected also in several up-gradient wells, it is not clear whether it is related to the CCR.279 In the Report to Congress (1988), EPA concluded that ash ponds at the site are responsible for arsenic concentrations above the primary Maximum Contaminant Limit (MCL). EPA also concluded, however, that effects on ground water appeared to be limited to areas within the facility boundaries, and that there are no apparent receptors down-gradient of the facility. Resolution: EPRI (2010) claims that no new information was identified for this case, and that the impoundment was capped in 2007, included 2 feet of soil with 6” topsoil cover, and that remediation has been performed. Basis for Consideration as a Potential Damage Case: “While levels of arsenic found on-site exceed the primary MCL, there was no evidence available of off-site migration of contaminants. Therefore, this case is a potential damage case.”280 References
research reportNot linked to a paper · refsec
EPA (2007): 2007 Coal Combustion Waste Damage Case Assessments, Case #43 and a reference therein (Memorandum from SAIC to Dennis Ruddy regarding Rationale and Conclusions Regarding CommenterIdentified Fossil Fuel Combustion Waste Damage Cases, April 20, 2000. Compendium of nineteen alleged coal combustion wastes damage cases, May 3, 2007). http://www.regulations.gov/#!documentDetail;D=EPA-HQ-RCRA-2006-0796-0015
government reportNot linked to a paper · refsec · cited link
EPRI (2010): Evaluation of Coal Combustion Product Damage Cases, Volume 2: Site Information. EPRI 1020554, Final Report, September 2010. Accessed Online July 2012. http://www.epri.com/search/Pages/results.aspx?sq=1&k=Evaluation%20of%20Coal%20Combustion%20 Product%20Damage%20Cases Golder Associates, ibid. This report provides detailed, boring-based information, on the natural substrate of the
government reportNot linked to a paper · refsec · cited link
Management, March 15, 2011. For location, see GZA GeoEnvironmental, ibid, Figure 2. A possible effect of groundwater mounding due to high-rate infiltration from the unlined ponds, exacerbated by the steel slurry wall down-flow from the disposal site, cannot be ruled out as the cause for the appearance of lead in some of the so-called ‘up-gradient’ wells. See detailed hydrologic descriptions in the entry on NIPCO’s Bailly Generating Station southwest of the Michigan City’s Generation Station.
research reportNot linked to a paper · refsec
EPA (2007). IIa. CCR Damage Case Reassessment December 2014 Report to Congress (1988): Wastes from the Combustion of Coal by Electric Utility Power Plants,
government reportNot linked to a paper · refsec
U.S.EPA Office of Solid Waste and Emergency Response, EPA/530-SW-88-002, February 1988. Accessed Online August 2012. http://www.epa.gov/waste/nonhaz/industrial/special/fossil/coal-rtc.pdf Dames & Moore (1982): Review of existing literature and published data to determine if proven documented cases of danger to human health and the environment exist as a result of disposal of fossil fuel combustion waste, in USWAG, Report and Technical Studies on the Disposal and Utilization of Fossil Fuel Combustion Byproducts, October 26, 1982, Appendix B.
journal articleNot linked to a paper · refsec · cited link
NIPSCO (2010): Response of Northern Indiana Public Service Company, Michigan City Generating
government reportNot linked to a paper · refsec
Station, to Request for Information from U.S. EPA under Section 104(e) of the Comprehensive Environmental Response, Compensation, and Liability Act, October 4, 2010. Accessed Online August 2012. http://www.epa.gov/waste/nonhaz/industrial/special/fossil/surveys/nipsco-Mi-City.pdf KellerLynn (2010): Indiana Dunes National Lakeshore, Indiana, Katie KellerLynn, Geologic Resources
datasetNot linked to a paper · refsec · cited link
Division, National Park Service, US Department of the Interior, November 30, 2010. Accessed Online January 2013. http://www.nature.nps.gov/geology/inventory/publications/reports/INDU_GRI_scoping_summary_20101130.pdf
datasetNot linked to a paper · refsec · cited link
GZA GeoEnvironmental (2012): Final Round 10 Dam Assessment Report NIPSCO Michigan City Generating Station Coal Ash Impoundments, GZA GeoEnvironmental, Inc., GZA File No. 01.0170142.30, October 19, 2012. Accessed Online April 2013. http://www.epa.gov/epawaste/nonhaz/industrial/special/fossil/surveys2/nipsco_michigan_city_final.pdf Golder Associates (2012): Geotechnical Investigation and Embankment Stability Analyses, NIPSCO Michigan City Generating Station, Michigan City, Indiana, Golder Associates, Inc. Project No. 12388898, August 27, 2012, in GZA GeoEnvironmental (2012, Appendix F). Accessed Online April 2013. http://www.epa.gov/epawaste/nonhaz/industrial/special/fossil/surveys2/nipsco_michigan_city_final.pdf PTa17. Indianapolis Power & Light281 (IPL) Petersburg Generating Station,282 Pike
datasetNot linked to a paper · refsec · cited link
County, Indiana Type: Landfill. Background and Description: According to EPRI (2010), a 75-acre landfill, constructed/expanded from 1976 to 1997. The landfill is active and a 45-acre expansion has been approved but not yet
research reportNot linked to a paper · refsec
EPA (2007) cites this case as Indiana Power & Light. IPL is a subsidiary of AES Corporation. According to CDM (2010), the Petersburg Generating Station, located about three miles northeast of town, began operation in June 1967. The CCR is generated by Unit ST1 (online since 1967), Unit ST2 (online since 1969), Unit ST3 (online since 1977), and ST4 (online since 1986). Based on the last three years of operation, the plant burns 15,000 tons of bituminous coal from the surrounding region (Illinois Basin), producing approximately 1,500 tons of
government reportNot linked to a paper · refsec
EPA (2007): Coal Combustion Waste Damage Case Assessments, Case #59 and a reference therein (Memorandum from SAIC to Dennis Ruddy regarding Rationale and Conclusions Regarding CommenterIdentified Fossil Fuel Combustion Waste Damage Cases, April 20, 2000.) http://www.regulations.gov/#!documentDetail;D=EPA-HQ-RCRA-2006-0796-0015 Cherry et al., (2000): Review of the Global Adverse Environmental Impacts to Ground Water and Aquatic Ecosystems from Coal Combustion Wastes. Donald S. Cherry, Rebecca J. Currie, and
journal articleNot linked to a paper · refsec · cited link
IPL (2009): Response to U.S. EPA l04(e) Information Request to Indianapolis Power & Light Company ("IPL") – Petersburg Generating Station, May 13, 2009. Accessed Online October 2012. http://www.epa.gov/waste/nonhaz/industrial/special/fossil/surveys/ipl-peter.pdf
government reportNot linked to a paper · refsec · cited link
CDM (2010): Assessment of Dam Safety of Coal Combustion Surface Impoundments, Indianapolis Power & Light Company Petersburg Generating Station, CDM, November 15, 2010. Accessed Online October 2012. http://www.epa.gov/waste/nonhaz/industrial/special/fossil/surveys2/ipl-petersburg-final.pdf
government reportNot linked to a paper · refsec · cited link
IPL (2011): Response to January 7, 2011, Final Report of Assessment of Dam Safety of Coal Combustion Surface Impoundments, Indianapolis Power & Light Company, Petersburg Generating Station, February 21, 2011. Accessed Online October 2012. http://www.epa.gov/wastes/nonhaz/industrial/special/fossil/surveys2/ipl-petersburg-response.pdf Turka and Gray (1996): Use of Coal Combustion By-Products in Abandoned Mine Land Reclamation,
government reportNot linked to a paper · refsec · cited link
Robert J. Turka and Richard E. Gray, GAI Consultants, Inc., R. James Meiers, Indianapolis Power & Light Company, and Dean M. Golden, Electric Power Research Institute, 1996. Accessed Online January 2013. http://wvmdtaskforce.com/proceedings/96/96TUR/96TUR.HTM PTa18. NiSource (Formerly: NIPSCO) R.M. Schahfer Generating Station,289 Wheatfield, Jasper County, Indiana Type: Surface Impoundments; Some Converted into a Landfill. Background and Description: The Schahfer Generating Station is located about one mile northeast of
datasetNot linked to a paper · refsec · cited link
CY, and receives bottom ash, boiler slag and other waste. The Yard Drain Stormwater Retention Pond, in service since 1999, has surface area of 1.3 acres and water capacity of 9000 CY. The Recycle Basin, in service since 1982, has surface area of 30 acres and water capacity of 600,000 CY. The FGD Landfill Stormwater Runoff Pond, in service since 1983, has surface area of 4.5 acres and water capacity of 19,000 CY. The Final Settling Basin, in service since 1976, has surface area of 214 acres and water capacity of 3,550,000
research reportNot linked to a paper · refsec
However, elsewhere EPRI (2010) indicates that ‘ash handling procedures were changed from sluicing to dry ash handling and the new cell design was modified.’ As long as the power station’s dam integrity assessment report is withheld from public access (due to a CBI claim), the discrepancy between EPRI’s (2010) landfill data and the
research reportNot linked to a paper · refsec
NIPSCO (2009) waste units’ data cannot be reconciled.
government reportNot linked to a paper · refsec
EPA concluded in the supplemental analysis that other pollutant exceedances at the site appeared to be outliers or were for up-gradient wells only. According to EPRI (2010), post-remediation, onsite exceedances include boron, iron, chloride, sodium, manganese, molybdenum, and sulfate.310 Several wells experienced selenium and silver spikes in the mid-2000s that were not tabulated as exceedances due to their short duration (one to two samples). Resolution: According to EPRI (2010), no Consent Order and/or other state/federal action has been identified for this Site. The unlined cells are inactive and have been capped in 1994, and a geomembrane cap was applied in 1998/99. Ash handling procedures were changed from sluicing to dry ash handling and the new cell design was modified. Phases III, IV, and subsequent phases have composite liners (compacted clay, 60 mil HDPE geo-membrane) and leachate collection systems. A groundwater
government reportNot linked to a paper · refsec
DNR (1990) and Indiana Division of Water (1990).
government reportNot linked to a paper · refsec
DNR (1990). Ibid. The Kankakee Aquifer System is highly susceptible to contamination from surface sources.
government reportNot linked to a paper · refsec
Supplemental Analysis (1993). According to Cherry et al., (2000), four constituents in down-gradient monitoring wells were greater than federal limits at this Indiana site. Sulfate reached a high of 27,500 mg/L; boron reached a high of 25 mg/L; the highest sodium measurement was 11,000 mg/L; and chloride - 1,400 mg/L. Tabulation of exceedances in groundwater after remediation based on data provided by the power company covering the period 1998 through March 2009.
research reportNot linked to a paper · refsec
EPRI (2010) presents no data for any of these constituents prior to remediation. IIa. CCR Damage Case Reassessment December 2014 monitoring program is in effect and wells closest to the property boundary have concentrations below applicable standards.
government reportNot linked to a paper · refsec
EPRI (2010) claims that there are on-site exceedances of constituents that do not have MCLs; and that remediation has been performed, the exceedances are limited to an area close to the facility, and monitoring wells farther down-gradient do not show exceedances, nor is there evidence of groundwater supply wells within one mile down-gradient of the facility. According to EPA,311 following RCRA Corrective Action, as of July 2011, human exposure and contaminated groundwater migration are under control. Basis for Consideration as a Potential Damage Case: “The sulfate exceedances found at this site are of non-health-based standards. Therefore, this case is a potential damage case.”312 References
government reportNot linked to a paper · refsec
EPA (2007): Coal Combustion Waste Damage Case Assessments, Case #55 and a reference therein (Memorandum from SAIC to Dennis Ruddy regarding Rationale and Conclusions Regarding CommenterIdentified Fossil Fuel Combustion Waste Damage Cases, April 20, 2000). http://www.regulations.gov/#!documentDetail;D=EPA-HQ-RCRA-2006-0796-0015 Cherry et al., (2000): Review of the Global Adverse Environmental Impacts to Ground Water and Aquatic Ecosystems from Coal Combustion Wastes. Donald S. Cherry, Rebecca J. Currie, and
journal articleNot linked to a paper · refsec · cited link
EPRI (2010): Evaluation of Coal Combustion Product Damage Cases, Volume 2: Site Information. EPRI 1020554, Final Report, September 2010. Accessed Online August 2012. http://my.epri.com/portal/server.pt?space=CommunityPage&cached=true&parentname=ObjMgr&parenti d=2&control=SetCommunity&CommunityID=405
government reportNot linked to a paper · refsec · cited link
NIPSCO (2009): Response of Northern Indiana Public Service Company, R.M. Schahfer Generating
government reportNot linked to a paper · refsec
Compensation, and Liability Act ("CERCLA"), March 26, 2009. Accessed Online October 2012. http://www.epa.gov/waste/nonhaz/industrial/special/fossil/surveys/nipsco-schahfer.pdf Northern Indiana Public Service Company (NIPSCO) claims that the EPA assessment report for their R.M. Schahfer Power Plant contains “Confidential Business Information.” Accessed Online October 2012. http://www.epa.gov/waste/nonhaz/industrial/special/fossil/surveys2/rm-schahfer-cbi.pdf
datasetNot linked to a paper · refsec · cited link
DNR (1990): Water Resource Availability in the Kanakakee River Basin, Indiana , Indiana Department of Natural Resources, Division of Water. Accessed Online January 2013. (Executive Summary of: Water resource availability in the Kankakee River Basin, Indiana: Clendenon, C.J. and Beaty, J.E., eds., 1987, Final Remedy Decision occurred on June 4, 2009, and solution for cleanup was implemented by April 6, 2010. https://obipublic.epa.gov/sso/analytics/saw.dll?PortalPages&Action=Navigate&col1=RCRA_PROFILE_FINAL.HA NDLER_ID&val1=IND082859455&PortalPath=/shared/CIMC/_portal/CIMC&Page=RCRA+Profile+Page#contam ination. (No longer accessible).
government reportNot linked to a paper · refsec · cited link
EPA (2007). IIa. CCR Damage Case Reassessment December 2014 Indiana Department of Natural Resources, Division of Water, Water Resources Assessment 90-3). Accessed Online October 2012. http://www.in.gov/dnr/water/files/kankakee_basinsums.pdf Indiana Division of Water (1990): Lower Kankakee River Basin, Plate 2B: Unconsolidated and Bedrock Aquifer Systems. Accessed Online October 2012. http://www.in.gov/dnr/water/files/kank-lowa_basinsums.pdf
government reportNot linked to a paper · refsec · cited link
Quality, T073-29983-00008. Accessed Online January 2013. http://permits.air.idem.in.gov/29983p.pdf Brady and Pfitzer (2007): A Prescriptive Analysis of the Indiana Coal Transportation Infrastructure,
datasetNot linked to a paper · refsec · cited link
Brady, T. F., and C. M. Pfitzer, Publication FHWA/IN/JTRP-2007/15. Joint Transportation Research
research reportNot linked to a paper · refsec
Program, Indiana Department of Transportation and Purdue University, West Lafayette, Indiana, 2007. Accessed Online January 2013. http://docs.lib.purdue.edu/cgi/viewcontent.cgi?article=1708&context=jtrp&seiredir=1&referer=http%3A%2F%2Fwww.google.com%2Furl%3Fsa%3Dt%26rct%3Dj%26q%3Dnisource %2520m.%2520schahfer%2520generating%2520station%26source%3Dweb%26cd%3D88%26ved%3D0 CFoQFjAHOFA%26url%3Dhttp%253A%252F%252Fdocs.lib.purdue.edu%252Fcgi%252Fviewcontent. cgi%253Farticle%253D1708%2526context%253Djtrp%26ei%3DGPQJUeXbOPPW0gH8z4GYBg%26u sg%3DAFQjCNHSbSAirqtMCksN8vif6exNuBw33w#search=%22nisource%20m.%20schahfer%20gene rating%20station%22 Supplemental Analysis (1993): Supplemental Analysis of Potential Risks to Human Health and the Environment from Large-Volume Coal Combustion Waste. U.S. EPA. July 30, 1993. Available from the docket for the 1993 Regulatory Determination for Fossil Fuel Combustion (Part 1), EPA-HQ-RCRA1993-0042-1642.
datasetNot linked to a paper · refsec · cited link
EPRI (2012): FGDExpert Demonstration at NIPSCO Schahfer Unit 17: Oxidation Reduction Potential Effects on Scrubber Chemistry (abstract); December 31, 2012. Accessed Online January 2014. http://www.epri.com/abstracts/Pages/ProductAbstract.aspx?ProductId=000000000001023069
government reportNot linked to a paper · refsec · cited link
NIPSCO’s dam assessment report: (as of December 17, 2014, NIPSCO’s dam assessment report is still unaccessible because NIPSCO claims it is Confidential Business Information, CBI). http://www.epa.gov/osw/nonhaz/industrial/special/fossil/surveys2/nipsco_schahfer_cbi.pdf IIa. CCR Damage Case Reassessment December 2014 PTa19. Muscatine County Landfill, Montpelier, Iowa Type: Offsite Landfill (Monofill). Background and Description: The Muscatine County CCR landfill is located about five miles west of
research reportNot linked to a paper · refsec · cited link
EPRI (2010) concludes that ‘No new information was identified for this case. In the 2007 USEPA Damage Case Assessment, the MCL exceedances were described as “on-site” and “close to the waste management unit” (i.e., exceedances likely occur within the operational limit of the facility). IIa. CCR Damage Case Reassessment December 2014 Basis for Consideration as a Potential Damage Case: “The exceedances of non-health-based standards (secondary MCL for sulfate) and possibly a single health-based standard (primary MCL for selenium) at this site are in wells located on-site, close to the waste management unit. Therefore, this case is a potential damage case.”320 References
government reportNot linked to a paper · refsec
EPA (2007): Coal Combustion Waste Damage Case Assessments, Case #64 and references therein (Memorandum from SAIC to Dennis Ruddy regarding Rationale and Conclusions Regarding CommenterIdentified Fossil Fuel Combustion Waste Damage Cases, April 20, 2000; and Memorandum from SAIC to Dennis Ruddy regarding Final Revised Report on Resolution of 18 Previously Indeterminate Candidate Damage Cases, March 5, 2003.) http://www.regulations.gov/#!documentDetail;D=EPA-HQ-RCRA-2006-0796-0015
government reportNot linked to a paper · refsec · cited link
EPRI (2010): Evaluation of Coal Combustion Product Damage Cases, Volume 2: Site Information. EPRI 1020554, Final Report, September 2010. Accessed Online August 2012. http://www.epri.com/search/Pages/results.aspx?sq=1&k=Evaluation%20of%20Coal%20Combustion%20 Product%20Damage%20Cases Spencer & Drake (1987): Hydrogeology of an Alkaline Fly Ash Landfill in Eastern Iowa/Linda Le Seur Spencer & Lon D. Drake, Groundwater, Vo. 25, No. 5, Sept. – Oct. 1987. Accessed Online October 2012. http://info.ngwa.org/gwol/pdf/872543927.PDF Spencer & Drake (1987). Spencer & Drake (1987) provide a detailed hydrogeological and hydrochemical analysis of the evolution of the local groundwater, as it moves from up-gradient monitoring wells through the landfill to down-gradient monitoring wells. According to Spencer & Drake (1987), the loess is of Wisconsinian age, about 28,000 to 13,000 years BP. The till is the Illinoian Kellerville member of the Glasford Formation, and the sandstone is the Pennsylvanian-age Spoon Formation of the Kewanee Group. According to CIPCO (2012), the facility consists of two units: Unit #1 has a capacity of 24 MW, while Unit #2 is rated at 42 MW. Production began in 1960. Both units were leased by Central Iowa Power Cooperative (CIPCO) in 1982. CIPCO purchased them from Eastern Iowa Light & Power in 1996. Fair Station Unit #2 is equipped with an
government reportNot linked to a paper · refsec · cited link
ESP with flue gas conditioner and low-NOX burners. Unit #1 is equipped with an ESP. It used coal from southern Illinois and western Kentucky. The coal was fired in a dry-bottom pulverized coal furnace, with the fly ash retained in mechanical dust collectors, passed through a water venturi then sluiced into an ash pond. This pond was dewatered each summer when the ash was excavated and hauled to the landfill. CIPCO is evaluating the possibility of retiring the Station by the end of 2013 due to economic and environmental compliance reasons. However, this decision has not been finalized and repowering options are also being considered.
research reportNot linked to a paper · refsec