ArcelorMittal, Cleveland, OH (AM-Cleveland-OH) No. 1 BOF Sec BH Stack Test 04/24-25/2012
Other documents for the same rulemaking
References: 5 extracted, 0 linked to papers
PASS 1.836 T-DGM- 001 Add Values to 30 Day Calibration History Add Values to Dry Gas Meter Calibration History Tag Meter Box Job Number: 032812 Done By: PB / Date: 3/28/2012 15:15 Air Compliance Testing, Inc. (032812-Pre-Test Meter Console) 4/30/2012 4 - 11
MTB- 009 Pump Number PMP- 009 Job Number: 120401A Done By: PB / Date: 4/27/2012 15:28 Air Compliance Testing, Inc. (120401A-ALT-009 Post-Test Leak Check) 5/8/2012 4 - 12 Method 4 DGM Calibration History Type
PASS 2.067 T-DGM- 010 Add Values to 30 Day Calibration History Add Values to Dry Gas Meter Calibration History Tag Meter Box Job Number: 031912 Done By: MC / Date: 3/19/2012 15:56 Air Compliance Testing, Inc. (031912-Pre-Test Meter Console) 4/30/2012 4 - 21 Meter Box Pre-Test Leak Check Remove the front panel from the meter box Disconnect the fan Hook up the proper pump to the meter box Close both the fine and coarse adjustment valves Connect the DH hoses on the front of the meter box Remove the copper elbow from stainless tube at the exit side of gas meter Stopper the stainless tube with a rubber stopper Disconnect the DH static line from the orifice (bottom) Plug in leak check tube into the static side of the orifice Blowing into the leak check tube, pressurize the system to 5-7 inches and clamp off Hold for one minute No leakage should occur. If leak is present, it must be corrected Affix (w/ electrical tape) the copper elbow onto the stainless tube at the exit side of gas meter Reassemble meter box Plug in capped swagelok stem at sample inlet Start pump, bringing system vacuum to at least 15 in. Hg Note DGM reading, start timer Observe DGM for one minute No leakage should occur. If leak is present, it must be corrected Check oil wick position (should be 1/4" above the black O-ring) Check pump oil level (should be at fill line) Meter Box Number
PASS 1.836 T-DGM- 001 Add Values to 30 Day Calibration History Add Values to Dry Gas Meter Calibration History Tag Meter Box Job Number: 032812 Done By: PB / Date: 3/28/2012 15:15 Air Compliance Testing, Inc. (032812-Pre-Test Meter Console) 4/30/2012 4 - 24
MTB- 006 Pump Number PMP- 006 Job Number: 120401 Done By: KL / Date: 5/4/2012 10:30 Air Compliance Testing, Inc. (120401A-ALT-009 Post-Test Leak Check) 5/8/2012 4 - 25