Specifications for Medical Examinations of Underground Coal Miners
Federal Register2012-01-09 · DEPARTMENT OF HEALTH AND HUMAN SERVICES · Proposed Rule · 2011-33164
Notice of proposed rulemaking.
With this notice of proposed rulemaking, the Department of Health and Human Services (HHS) proposes to modify its regulations on Specifications for Medical Examinations of Underground Coal Miners. Existing regulations establish specifications for providing, interpreting, classifying, and submitting film-based roentgenograms (now commonly called chest radiographs or X-rays) of underground coal miners for the surveillance of coal workers' pneumoconiosis (black lung) under the Coal Workers' Health Surveillance Program, administered by the National Institute for Occupational Safety and Health (NIOSH). The current standards specify requirements that permit the use of film- based radiography systems only; proposed amendments would retain those standards (with minor modifications that reflect more commonly-used terms) and add a parallel set of standards to specify requirements that would permit the use of digital radiography systems. An additional proposed amendment would require coal mine operators to provide NIOSH with employee rosters to assist the Program in improving participation by miners.
Original sourceXML (236 KB)PDF (286 KB)
Other documents for the same rulemaking
References: 23 extracted, 14 linked to papers
Page 1Download these results: CSV · JSON
Petsonk EL, Parker JE [2008]. Coal workers' lung diseases and silicosis. In: Fishman AP, Elias J, Fishman J, Grippi M, Senior R, Pack A eds. Fishman's Pulmonary Diseases and Disorders. 4th ed. New York: McGraw-Hill, pp. 967-980.
book chapterNot linked to a paper · fn 1
International Labour Office [2011]. Guidelines for the use of ILO International Classification of Pneumoconiosis, revised edition 2011. Geneva, Switzerland: International Labour Office. Occupational Safety and Health Series No. 22 (Rev. 2011).
government reportNot linked to a paper · fn 3
NIOSH [2007]. Roentgenographic Interpretation Form. Date accessed: January 5, 2011.
NIOSH [1995]. Criteria for a recommended standard: Occupational exposure to respirable coal mine dust. Cincinnati, Ohio: DHHS (NIOSH) Publication No. 95-106.
Secondary prevention is particularly important when a risk to health remains in spite of adherence to recommended or permissible exposure levels, as has been demonstrated for coal miners.\5\ --------------------------------------------------------------------------- ---------------------------------------------------------------------------
NIOSH [2008]. Application of the ILO International Classification of Radiographs of Pneumoconioses to Digital Chest Radiographic Images: A NIOSH Scientific Workshop. DHHS (NIOSH) Publication No. 2008-139.
However, over the past decade digital radiography systems have been progressively replacing traditional analog film-based radiography for chest imaging.\6\ ---------------------------------------------------------------------------
Samei E, Ravin CE [2008]. Assuring image quality for classification of digital chest radiographs. In: NIOSH... Publication No. 2008-139.
book chapterNot linked to a paper · fn 9
Work-Related Lung Disease (WoRLD) Surveillance System, Volume 1: Coal Workers' Pneumoconiosis: Morbidity, Table 2012.
U.S. Department of Labor, Mine Safety and Health Administration. Mining Industry Accident, Injuries, Employment, and Production Data—Address & Employment Self-Extracting Files.
Franzblau A, Kazerooni EA, Sen A, Goodsitt MM, Lee SY, Rosenman KD, Lockey JE, Meyer CA, Gillespie BW, Petsonk EL, Wang ML [2009]. Comparison of digital radiographs with film radiographs for the classification of pneumoconiosis. Acad Radiol 16(6):669-677.
Exact specifications for the digital imaging detector are provided because detectors must provide sufficient image size and gray scale depth to demonstrate the required subtle contrasts, and sufficient density of pixels to offer adequate resolution for the fine linear fibrotic shadows.\10\ The specification of a maximum pixel pitch of 200 [mu]m, a minimum gray-scale bit depth of 10, and spatial resolution of at least 2.5 line pairs per millimeter are based upon the existing peer-reviewed research comparing digital and traditional imaging and ensures that the use of digital radiography systems will not result in reduced ability to recognize and quantify the abnormalities.\11\ Commercially-available imaging systems are able to meet these specifications.\12\ --------------------------------------------------------------------------- ---------------------------------------------------------------------------
Sen A, Lee SY, Gillespie BW, Kazerooni EA, Goodsitt MM, Rosenman KD, Lockey JE, Meyer CA, Petsonk EL, Wang ML, Franzblau A [2010]. Comparison of reliability of classification for pneumoconiosis of film and digital radiographs: A modeling approach. Acad Radiol 17(4):511-519.
journal articleNot linked to a paper · fn 11
Laney AS, Petsonk EL, Wolfe AL, Attfield MD [2009]. Comparison of storage phosphor computed radiography with conventional film-screen radiography in the recognition of pneumoconiosis. Eur Respir J, published ahead of print November 19, 2009.
Exact specifications for the digital imaging detector are provided because detectors must provide sufficient image size and gray scale depth to demonstrate the required subtle contrasts, and sufficient density of pixels to offer adequate resolution for the fine linear fibrotic shadows.\10\ The specification of a maximum pixel pitch of 200 [mu]m, a minimum gray-scale bit depth of 10, and spatial resolution of at least 2.5 line pairs per millimeter are based upon the existing peer-reviewed research comparing digital and traditional imaging and ensures that the use of digital radiography systems will not result in reduced ability to recognize and quantify the abnormalities.\11\ Commercially-available imaging systems are able to meet these specifications.\12\ --------------------------------------------------------------------------- ---------------------------------------------------------------------------
Shepard SJ, Wang J, Flynn M, et al. [2009]. An exposure indicator for digital radiography. Report of AAPM Task Group 116. AAPM Report No. 116.
Because of the recognized potential for higher ionizing radiation exposures using digital radiography systems, we have included additional requirements to limit these exposures in accordance with recommendations established by the American Association of Physicists in Medicine.\13\ --------------------------------------------------------------------------- ---------------------------------------------------------------------------
Rossi R, Lin PJ, Rauch P, Strauss K [1985]. Performance specifications and acceptance testing for X-ray generators and automatic exposure control devices. AAPM Report No. 14.
Because of the recognized potential for higher ionizing radiation exposures using digital radiography systems, we have included additional requirements to limit these exposures in accordance with recommendations established by the American Association of Physicists in Medicine.\13\ --------------------------------------------------------------------------- ---------------------------------------------------------------------------
Seibert JA, et al. [2006]. Acceptance testing and quality control of photostimulable storage phosphor imaging systems. Report of AAPM Task Group 10. AAPM Report No. 93.
Because of the recognized potential for higher ionizing radiation exposures using digital radiography systems, we have included additional requirements to limit these exposures in accordance with recommendations established by the American Association of Physicists in Medicine.\13\ --------------------------------------------------------------------------- ---------------------------------------------------------------------------
Suganuma N, Murata K, Kusaka Y [2008]. CR and FPD DR chest radiographic image parameters for the pneumoconioses: The Japanese approach and experience.
book chapterNot linked to a paper · fn 17
Franzblau A, Kazerooni EA, Goodsitt M [2009]. Digital X-ray imaging in pneumoconiosis screening: Future challenges for the NIOSH B Reader Program. DHHS (NIOSH) Publication No. 2009-140.
book chapterNot linked to a paper · fn 17
Schaefer-Prokop C, Neitzel U, Venema HW, Uffmann M, Prokop M [2008]. Digital chest radiography: An update on modern technology, dose containment and control of image quality. Eur Radiol 18(9):1818-1830.
Unlike film-screen radiology, digital radiography systems are susceptible to dose creep.\22\ Dose creep in this setting involves increasing examinee radiation exposures over time for similar types of examinations (e.g., chest radiographs) performed at a facility.
Morgan RH. Proficiency examination of physicians for classifying pneumoconiosis chest films. Am J Roentgenology 1979;132:803-08.
The performance of the examination has been described in two manuscripts published in the peer-reviewed literature.\32\ --------------------------------------------------------------------------- ---------------------------------------------------------------------------
Wagner GR, Attfield MD, Kennedy RD, Parker JE. The NIOSH B Reader Certification Program—An update report. Journal of Occupational Medicine. 1992; 34:879-884.
The performance of the examination has been described in two manuscripts published in the peer-reviewed literature.\32\ --------------------------------------------------------------------------- ---------------------------------------------------------------------------
NIOSH [2011]. NIOSH Guideline: Application of Digital Radiography for the Detection and Classification of Pneumoconiosis. DHHS (NIOSH) Publication Number 2011-198. August 2011.
The referenced NIOSH guidance document is newly- developed and released; \33\ approval as an A or B Reader requires this basic level of knowledge. --------------------------------------------------------------------------- ---------------------------------------------------------------------------
Ruckley VA, Fernie JM, Chapman JS, et al. [1984]. Comparison of radiographic appearances with associated pathology and lung dust content in a group of coalworkers. Br J Ind Med 41(4): 459-467.
Research using film-screen radiographs and classifications based upon the current ILO standard film radiographs has demonstrated that chest radiograph classification results correlate significantly with objective independent measures of dust exposure or lung dust content.\26\ To maintain the documented validity of the ILO classification system, the rule specifies that each reader compare digital images submitted under this regulation with NIOSH-approved digital versions of the standard images, and that no software modification of the standard images can be permitted. --------------------------------------------------------------------------- ---------------------------------------------------------------------------
Cockcroft A, Lyons JP, Andersson N, and Saunders MJ [1983]. Prevalence and relation to underground exposure of radiological irregular opacities in South Wales coal workers with pneumoconiosis. Br J Ind Med 40(2): 169-172.
Research using film-screen radiographs and classifications based upon the current ILO standard film radiographs has demonstrated that chest radiograph classification results correlate significantly with objective independent measures of dust exposure or lung dust content.\26\ To maintain the documented validity of the ILO classification system, the rule specifies that each reader compare digital images submitted under this regulation with NIOSH-approved digital versions of the standard images, and that no software modification of the standard images can be permitted. --------------------------------------------------------------------------- ---------------------------------------------------------------------------
Trout ED, Kelley JP [1973]. A phantom for the evaluation of techniques and equipment used for roentgenography of the chest. Amer J Roentgenol 117(4):771-776.