Standards of Performance for Greenhouse Gas Emissions From New, Modified, and Reconstructed Stationary Sources: Electric Utility Generating Units
Federal Register2015-10-23 · ENVIRONMENTAL PROTECTION AGENCY · Rule · 2015-22837
Final rule.
The Environmental Protection Agency (EPA) is finalizing new source performance standards (NSPS) under Clean Air Act (CAA) section 111(b) that, for the first time, will establish standards for emissions of carbon dioxide (CO<INF>2</INF>) for newly constructed, modified, and reconstructed affected fossil fuel-fired electric utility generating units (EGUs). This action establishes separate standards of performance for fossil fuel-fired electric utility steam generating units and fossil fuel-fired stationary combustion turbines. This action also addresses related permitting and reporting issues. In a separate action, under CAA section 111(d), the EPA is issuing final emission guidelines for states to use in developing plans to limit CO<INF>2</INF> emissions from existing fossil fuel-fired EGUs.
Original sourceXML (1.5 MB)PDF (3.7 MB)
Other documents for the same rulemaking (all, by stage)
References: 75 extracted, 35 linked to papers
Page 2Download these results: CSV · JSON
“Cost and Performance Baseline for Fossil Energy Plants Volume 1a: Bituminous Coal (PC) and Natural Gas to Electricity Revision 3”, DOE/NETL-2015/1723 (July 2015)
There is nothing to suggest that the Shell CanSolv process would not work with other coal types and indeed, the latest NETL cost estimates assume that the capture technology would be used in a new unit using bituminous coal.\197\ The EPA is unaware of any reasons why the Boundary Dam technology would not be transferrable to another utility boiler at a different location at a different elevation or climate because the control technology is not climate or elevation-dependent. --------------------------------------------------------------------------- ---------------------------------------------------------------------------
Dooley, J. J., et al. (2009). “An Assessment of the Commercial Availability of Carbon Dioxide Capture and Storage Technologies as of June 2009”. U.S. DOE, Pacific Northwest National Laboratory
The captured CO2 from the Shady Point Plant is also sold for use in the food processing industry.\198\ While these projects do not demonstrate the CO2 storage component of CCS, they clearly demonstrate the technical viability of partial CO2 capture.
Ivie, M.A. et al.; “Project Status and Research Plans of 500 TPD CO2 Capture and Sequestration Demonstration at Alabama Power's Plant Barry”, Energy Procedia 37, 6335 (2013).
The captured CO2 has been transported via pipeline approximately 12 miles to the Citronelle oil field where it is injected into the Paluxy formation, a saline reservoir, for storage.\210\ --------------------------------------------------------------------------- ---------------------------------------------------------------------------
CCS front end engineering & design report: American Electric Power Mountaineer CCS II Project. Phase 1
Technical Support Document—“Literature Survey of Carbon Capture Technology”
research reportNot linked to a paper · fn 188
Atmospheric Environment, 43, 3974 (2009)
journal articleNot linked to a paper · fn 195
NETL (2015) at p. 44.
research reportNot linked to a paper · fn 412
United States 2012 Carbon Utilization and Storage Atlas, Fourth Edition.
datasetNot linked to a paper · fn 413
Grude, S. M. Landrøa, and J. Dvorkinb, 2014, Pressure effects caused by CO2 injection in the Tubåen Fm., the Snøhvit field. International Journal of Greenhouse Gas Control 27 (2014) 178-187.
Between 2008 and 2011, the operator observed pressure increases in the injection formation (Tubaen Formation) greater than expected and conducted time lapse seismic surveys and studies of the injection zone and concluded that the pressure increase was mainly caused by a limited storage capacity in the formation.\478\ In 2011,
Haibo Zhai, et al., Water Use at Pulverized Coal Power Plants with Post-combustion Carbon Capture and Storage, 45 Environ. Sci. Technol., 2479-85 (2011).
At least one commenter claimed that addition of an amine-based CCS system would double the consumptive water use of a power plant, which would be unacceptable, especially in drought-ridden states and in the arid west and referenced a study in the scientific literature as support.\499\ The commenter also references a DOE/NETL report that likewise notes significant increases in the amount of cooling and process water required with the use of carbon capture technology.\500\ However, those studies discuss increased water use for cases where full CCS (90 percent or greater capture) is implemented.
DOE/NETL-402/080108, "Water Requirements for Existing and Emerging Thermoelectric Plant Technologies" at 13 (Aug. 2008, Apr. 2009 revision).
research reportNot linked to a paper · fn 500
Cost and Performance Baseline for Fossil Energy Plants Supplement: Sensitivity to CO2 Capture Rate in Coal-Fired Power Plants, DOE/NETL-2015/1720 (June 22, 2015).
Table 13--Predicted Water Consumption With Implementation of Various Levels of Partial CCS \501\ ------------------------------------------------------------------------ Raw water Increase Technology consumption, compared to gpm SCPC, % ------------------------------------------------------------------------ SCPC....................................
Cost and Performance Baseline for Fossil Energy Plants Volume 1: Bituminous Coal and Natural Gas to Electricity, Revision 2, Report DOE/NETL-2010/1397 (November 2010).
research reportNot linked to a paper · fn 508
Cost and Performance Baseline for Fossil Energy Plants Volume 3b: Low Rank Coal to Electricity: Combustion Cases, Report DOE/NETL-2010/1463 (March 2011).
According to the DOE/NETL estimates, a newly constructed subcritical PC unit firing bituminous coal would emit approximately 1,800 lb CO2/MWh-g,\508\ a new highly efficient SCPC unit using bituminous coal would emit nearly 1,720 lb CO2/MWh-g, and a new IGCC unit would emit about 1,430 lb CO2/MWh- g.509 510 Emissions from comparable sources utilizing sub- bituminous coal or lignite will have somewhat higher CO2 emissions.\511\ --------------------------------------------------------------------------- ---------------------------------------------------------------------------
Near Term Projections of CO2 Utilization for Enhanced Oil Recovery”. DOE/NETL-2014/1648. April 2014.
For example, in an April 2014 study, DOE concluded that future development of EOR will need to rely on captured CO2.\486\ Thus, the argument that EOR operators will obtain CO2 from other sources without triggering subpart RR responsibilities, which assumes adequate supplies of CO2 from other sources, lacks foundation.
Intergovernmental Panel on Climate Change. (2005). Special Report on Carbon Dioxide Capture and Storage.
An IPCC special report on CCS found that with an appropriate site selection, a monitoring program, a regulatory system, and the appropriate use of remediation methods, the risks of GS would be comparable to risks of current activities, such as EOR, acid gas injection and underground natural gas storage.\493\ Furthermore, an interagency CCS task force examined GS-related legal issues thoroughly and concluded that early CCS projects can proceed under the existing legal framework with respect to issues such as property rights and liability.\494\ As noted earlier, both the Archer Daniels Midland (ADM) and FutureGen projects addressed siting and operational aspects of GS (including issues relating to volumes of the CO2 and the nature of the CO2 injectate) in their permit applications.
IPCC, Working Group III, Climate Change 2014: Mitigation of Climate Change, http://mitigation2014.org/report/publication/ .
The improved performance and lower costs will provide additional incentive for further implementation in the future. The Intergovernmental Panel on Climate Change (IPCC) recently released its Fifth Assessment report, \516\ which recognizes that widespread deployment of CCS is crucial to reach the long term climate goals.
CCS LESSONS LEARNED REPORT American Electric Power Mountaineer CCS II Project Phase 1, Prepared for The Global CCS Institute Project # PRO 004, January 23, 2012.
research reportNot linked to a paper · fn 517
Cichanowitz CCS Report (2012).
research reportNot linked to a paper · fn 496
Lubbock, TX to Thompsons, TX—Amine Scrubbing for Commercial CO2 Capture from Power Plants, plenary address by Prof. Gary Rochelle at the 12th International Conference on Greenhouse Gas Technology (GHGT-12), Austin, TX (October 2014).
otherNot linked to a paper · fn 505
AEP FEED Study at pp. 36-43.
research reportNot linked to a paper · fn 497
M. Mansouri, et al. "Exergetic and Economic Evaluation of the Effects of HRSG Configurations on the Performance of Combined Cycle Power Plants." Energy Conversion and Management 58:47-58, 2012.
M. Rahim, Journal of Energy Engineering, 138:136-145, 2012. "Combined Cycle Power Plant Performance Analyses Based on Single-Pressure and Multipressure Heat Recovery Steam Generator."
N. Woudstras et al. "Thermodynamic Evaluation of Combined Cycle Plants." Energy Conversion and Management 51:1099-1110, 2010.
http://www.eia.gov/electricity/data/eia923/.