Cost and Performance Baseline for Fossil Energy Plants - Volume 3b: Low Rank Coal to Electricity: Combustion Cases
Open-access copyPublisher page (DOI)OpenAlex record
Cited in 1 place in policy documents
Standards of Performance for Greenhouse Gas Emissions From New, Modified, and Reconstructed Stationary Sources: Electric Utility Generating Units
Cost and Performance Baseline for Fossil Energy Plants Volume 3b: Low Rank Coal to Electricity: Combustion Cases, Report DOE/NETL-2010/1463 (March 2011).
According to the DOE/NETL estimates, a newly constructed subcritical PC unit firing bituminous coal would emit approximately 1,800 lb CO2/MWh-g,\508\ a new highly efficient SCPC unit using bituminous coal would emit nearly 1,720 lb CO2/MWh-g, and a new IGCC unit would emit about 1,430 lb CO2/MWh- g.509 510 Emissions from comparable sources utilizing sub- bituminous coal or lignite will have somewhat higher CO2 emissions.\511\ --------------------------------------------------------------------------- ---------------------------------------------------------------------------