Cerebral events and protection during transcatheter aortic valve replacement
Publisher page (DOI)OpenAlex record
Cited in 1 place in policy documents
Medicare Program; Hospital Inpatient Prospective Payment Systems for Acute Care Hospitals and the Long-Term Care Hospital Prospective Payment System and Proposed Policy Changes and Fiscal Year 2019 Rates; Proposed Quality Reporting Requirements for Specific Providers; Proposed Medicare and Medicaid Electronic Health Record (EHR) Incentive Programs (Promoting Interoperability Programs) Requirements for Eligible Hospitals, Critical Access Hospitals, and Eligible Professionals; Medicare Cost Reporting Requirements; and Physician Certification and Recertification of Claims
Freeman, M., et al., "Cerebral events and protection during transcatheter aortic valve replacement," Catheterization and Cardiovascular Interventions, 2014, vol. 84(6), pp. 885-896.
According to the applicant, the risk of stroke is highest in the early post[dash]procedure period and, as previously outlined, is likely due to mechanical factors occurring during the TAVR procedure.\168\ Emboli can be generated as wire-guided devices are manipulated within atherosclerotic vessels, or when calcified valve leaflets are traversed and then crushed during valvuloplasty and subsequent valve deployment.\169\ Stroke rates in patients evaluated 30 days after TAVR procedures range from 1.0 percent to 9.6 percent,\170\ and have been associated with increased mortality.