Reducing the CO2 Emission Intensity of Boundary Dam Unit 3 Through Optimization of Operating Parameters of the Power Plant and Carbon Capture Facilities
Open-access copyPublisher page (DOI)OpenAlex record
Cited in 3 places in policy documents
Partial Repeal of the Carbon Pollution Standards for Fossil Fuel-Fired Electric Generating Units
Jacobs, B., et al. Reducing the CO2 Emission Intensity of Boundary Dam Unit 3 Through Optimization of Operating Parameters of the Power Plant and Carbon Capture Facilities. Proceedings of the 16th International Conference on Greenhouse Gas Control Technologies (2022).
Repeal of Greenhouse Gas Emissions Standards for Fossil Fuel-Fired Electric Generating Units
Jacobs, B., et al. Proceedings of the 16th International Conference on Greenhouse Gas Control Technologies (October 2022). Reducing the CO2 Emission Intensity of Boundary Dam Unit 3 Through Optimization of Operating Parameters of the Power Plant and Carbon Capture Facilities. https://papers.ssrn.com/sol3/papers.cfm?abstract_id=4286430.
New Source Performance Standards for Greenhouse Gas Emissions From New, Modified, and Reconstructed Fossil Fuel-Fired Electric Generating Units; Emission Guidelines for Greenhouse Gas Emissions From Existing Fossil Fuel-Fired Electric Generating Units; and Repeal of the Affordable Clean Energy Rule
Jacobs, B., et al. Proceedings of the 16th International Conference on Greenhouse Gas Control Technologies (October 2022). Reducing the CO2 Emission Intensity of Boundary Dam Unit 3 Through Optimization of Operating Parameters of the Power Plant and Carbon Capture Facilities.
According to the 2022 paper co-authored by the International CCS Knowledge Centre and SaskPower, ``[a] number of initiatives are ongoing or planned with the goal of eliminating flue gas bypass as follows: Since 2016, online cleaning of demisters has been effective at controlling demister pressure; Chemical cleans and replacement of fouled packing in the absorber towers to reduce pressure losses; Optimization of antifoam injection and other aspects of amine health, to minimize foaming potential; [and] Optimization of Liquid-to- Gas (L/G) ratio in the absorber and other process parameters,'' as well as other optimization procedures.\297\ While foaming is mitigated by an antifoam injection regimen, the EPA further notes that the extent of foaming that could occur may be specific to the chemistry of the solvent and the source's flue gas conditions--foaming was not reported for MHI's KS-1 solvent when treating bituminous coal post-combustion flue gas at Petra Nova.