Policy Replication

Seasonal cooling performance of air conditioners: The importance of independent test procedures used for MEPS and labels

Carsten Palkowski, Stefan von Schwarzenberg, Anne Simo
2019 · International Journal of Refrigeration · article · doi:10.1016/j.ijrefrig.2019.05.021 · 29 scholarly citations

A free copy is available at the open-access link. Its license does not let us host the file here.

Cited in 1 place in policy documents

Energy Conservation Program: Test Procedure for Room Air Conditioners

Federal Register2021-03-29 · DEPARTMENT OF ENERGY · fn 27
Palkowski, Carsten & Schwarzenberg, Stefan & Simo, Anne. (2019). “Seasonal cooling performance of air conditioners: The importance of independent test procedures used for MEPS and labels.” International Journal of Refrigeration. 104. 10.1016/j.ijrefrig.2019.05.021.
their test mode.\26\ The California IOUs also cited research conducted at the Bundesanstalt f[uuml]r Materialforschung und -pr[uuml]fung (``BAM'') Federal Institute for Material Research and Testing in Germany, in which all but one of the seven residential mini-split air conditioners with variable-speed equipment that were tested consumed significantly higher energy when consumer-adjustable, built-in controls were used relative to fixed controls (i.e., controls that set the compressor speed using a manufacturer-provided remote or code).\27\ The California IOUs stated that researchers reported many units reverted to on-off (cycling) operation when the outdoor temperatures were between 77 and 86 [deg]F.