Simulation and Evaluation of Elemental Mercury Concentration Increase in Flue Gas Across a Wet Scrubber
Publisher page (DOI)OpenAlex record
Cited in 1 place in policy documents
National Emission Standards for Hazardous Air Pollutants: Proposed Standards for Hazardous Air Pollutants for Hazardous Waste Combustors (Phase I Final Replacement Standards and Phase II)
J. Chang and S. Ghorishi, “Simulation and Evaluation of Elemental Mercury Concentration Increase in Flue Gas Across a Wet Scrubber,” Environmental Science and Technology, Vol 37, No. 24, 2003, pp. 5763-5766.
Although limited test data from full-scale coal fired boiler evaluations indicate an inconsistent impact of scrubber liquid pH on mercury control,\279\ a recent study \280\ confirms that ionic mercury (e.g., HgCl2) that is initially captured in the scrubber can be reduced in the liquid to elemental Hg (i.e., H\o\) and then revolatilized to the stack gas.