Ultrasonic locating devices for central venous cannulation: meta-analysis
Open-access copyPublisher page (DOI)OpenAlex record
Cited in 2 places in policy documents
Medicare Program; Hospital Inpatient Prospective Payment Systems for Acute Care Hospitals and the Long-Term Care Hospital Prospective Payment System and Fiscal Year 2013 Rates; Hospitals' Resident Caps for Graduate Medical Education Payment Purposes; Quality Reporting Requirements for Specific Providers and for Ambulatory Surgical Centers
Hind, D.: “Ultrasonic device for central venous cannulation: Meta-analysis.” BJM, 2003, vol. 327, 7411:361-364.
Recommendations for the use of ultrasound as an adjunct to central venous line placement now exist and are based on supportive literature Category A (Randomized controlled trials report statistically significant (P > .01) differences between clinical interventions for a specified clinical outcome) with a Level 1 weight of scientific evidence (multiple randomized controlled trials with the aggregated findings supported by meta-analysis).\10\ Several studies have shown a decrease in the mechanical complication rate with the use of ultrasound during line placement.\11\ Guidelines for performing ultrasound guided vascular cannulation have been recently published.\12\ --------------------------------------------------------------------------- ---------------------------------------------------------------------------
Medicare Program; Hospital Inpatient Prospective Payment Systems for Acute Care Hospitals and the Long-Term Care Hospital Prospective Payment System and Fiscal Year 2013 Rates; Hospitals' Resident Caps for Graduate Medical Education Payment Purposes; Quality Reporting Requirements for Specific Providers and for Ambulatory Surgical Centers
Hind, D.: “Ultrasonic device for central venous cannulation: Meta-analysis.” BJM, 2003, vol. 327, 7411:361-364
Recommendations for the use of ultrasound as an adjunct to central venous line placement now exist and are based on supportive literature Category A (Randomized controlled trials report statistically significant (P -- .01) differences between clinical interventions for a specified clinical outcome) with a Level 1 weight of scientific evidence (multiple randomized controlled trials with the aggregated findings supported by meta-analysis).\10\ Several studies have shown a decrease in the mechanical complication rate with the use of ultrasound during line placement.\11\ Guidelines for performing ultrasound guided vascular cannulation have been recently published.\12\ --------------------------------------------------------------------------- ---------------------------------------------------------------------------