Technical and Economical Considerations on Super High-Efficiency Three-Phase Motors
Publisher page (DOI)OpenAlex record
Cited in 1 place in policy documents
Energy Conservation Program: Test Procedure for Electric Motors
A. T. De Almeida, F. J. T. E. Ferreira and A. Q. Duarte, "Technical and Economical Considerations on Super High-Efficiency Three-Phase Motors," IEEE Transactions on Industry Applications, vol. 50, no. 2, pp. 1274-1285, March-April 2014.
line-start permanent magnet motors), DOE found that the efficiency curve as a function of load is also flat in the typical motor operating range.\52\ Therefore, DOE has determined that measuring the performance of these motors at full-load is representative of an average use cycle and DOE adopts the nominal full-load efficiency metric as proposed for synchronous motors that are not inverter-only. --------------------------------------------------------------------------- ---------------------------------------------------------------------------