Policy Replication

A Comparison of direct and indirect measurement of induction motor efficiency

Emmanuel B. Agamloh
2009 · IEEE International Electric Machines & Drives Conference (IEMDC) · conference-paper · doi:10.1109/iemdc.2009.5075180 · 31 scholarly citations

This paper is behind a paywall; we link to the publisher only.

Cited in 1 place in policy documents

Energy Conservation Program: Test Procedure for Electric Motors

Federal Register2022-10-19 · DEPARTMENT OF ENERGY · fn 32
E.B. Agamloh, "A Comparison of direct and indirect measurement of induction motor efficiency," 2009 IEEE International Electric Machines and Drives Conference, 2009, pp. 36-42, doi: 10.1109/IEMDC.2009.5075180.
indirect methods.\31\ In the paper, Advanced Energy found that the direct method would vary in measured efficiency within a range of 1.26 percent points higher or 1.86 percent points lower compared to the indirect method and is too large of a difference for reporting purposes.\32\ NEMA stated that results