A Comparison of direct and indirect measurement of induction motor efficiency
Publisher page (DOI)OpenAlex record
Cited in 1 place in policy documents
Energy Conservation Program: Test Procedure for Electric Motors
E.B. Agamloh, "A Comparison of direct and indirect measurement of induction motor efficiency," 2009 IEEE International Electric Machines and Drives Conference, 2009, pp. 36-42, doi: 10.1109/IEMDC.2009.5075180.
indirect methods.\31\ In the paper, Advanced Energy found that the direct method would vary in measured efficiency within a range of 1.26 percent points higher or 1.86 percent points lower compared to the indirect method and is too large of a difference for reporting purposes.\32\ NEMA stated that results