Performance of Continuous Emission Monitoring Solutions under a Single-Blind Controlled Testing Protocol
Open-access copyPublisher page (DOI)OpenAlex record
Cited in 1 place in policy documents
Greenhouse Gas Reporting Rule: Revisions and Confidentiality Determinations for Petroleum and Natural Gas Systems
Bell, C., et al. "Performance of Continuous Emission Monitoring Solutions under a Single-Blind Controlled Testing Protocol." Environ. Sci. Technol. 2023, 57, 14, 5794-5805
Recent studies evaluating the performance of several continuous monitors have reported that these systems can provide valuable data for detecting anomalous emissions (and generally faster than survey methods) and determining event duration, but typically have high uncertainty in quantifying total emissions.\13\ Therefore, we determined that continuous monitoring systems currently are not suitable for quantifying emissions for subpart W reporting on their own but may provide data on the duration of large release events.