Mapping urban pipeline leaks: Methane leaks across Boston
Publisher page (DOI)OpenAlex record
Cited in 2 places in policy documents
Technical Support Document: Analysis of the U.S. Hydrofluorocarbon Reclamation Market: Stakeholders, Drivers, and Practices
Phillips, N.G., et al., (2012) "Mapping Urban Pipeline Leaks: Methane Levels Across Boston," Environmental Pollution.
Pipeline Safety: Gas Pipeline Leak Detection and Repair
Phillips et al., “Mapping Urban Pipeline Leaks: Methane Leaks Across Boston,” 173 Environmental Pollution at 1-4 (2013).
According to the equipment manufacturer, the G2301 device has sub 0.5 ppb precision over 5 seconds and an operating range of 0-20ppm when measuring methane,\160\ though testing of the device during the Boston study found analyzer output to be within 2.7 ppb of known gas concentration during testing.\161\ In Washington, DC, out of 5,893 methane readings detected from the vehicle with a concentration greater than 2.5 ppm, the minimum concentration defined as a leak indication in the study, 1,112 were measured at 5 ppm or greater.\162\ Additionally, the researchers inspected 19 of the larger emissions sources with a handheld combustible gas indicator and found gas concentration in nearby manholes exceeding 80% LEL (i.e., a grade 1 hazardous leak) at 12 locations.