Effectiveness of practices to reduce blood culture contamination: A Laboratory Medicine Best Practices systematic review and meta-analysis
Open-access copyPublisher page (DOI)OpenAlex record
Cited in 1 place in policy documents
Medicare Program; Hospital Inpatient Prospective Payment Systems for Acute Care Hospitals and the Long-Term Care Hospital Prospective Payment System and Proposed Policy Changes and Fiscal Year 2022 Rates; Quality Programs and Medicare Promoting Interoperability Program Requirements for Eligible Hospitals and Critical Access Hospitals; Proposed Changes to Medicaid Provider Enrollment; and Proposed Changes to the Medicare Shared Savings Program
Snyder S, et al. Effectiveness of practices to reduce blood culture contamination: A Laboratory Medicine Best Practices systematic review and meta-analysis. Clinical Biochemistry. 2012; 45(0):999-1011.
The applicant further noted that the major automated microbial blood culture detection systems (BACTEC and BacT/ALERT) recommend 8-10 mL of blood in each of the aerobic and anaerobic bottles--up to 40 mL total distributed across all four bottles. The applicant stated that despite the critical role blood culture plays in providing diagnoses, an estimated 20 percent to over 50 percent of all positive blood culture results for sepsis are suspected to be false positive due to blood culture contamination, as explained in greater detail below.\559\ The applicant stated that blood culture contamination creates clinical confusion which leads to a risk of inappropriate antibiotic therapy,560 561 562 563 extended length of stay of an average of 2.0 to 2.4 days,564 565 Clostridium difficile (CDI) infection,566 567 multidrug resistance organism (MDRO) infections, Acute Kidney Injury (AKI),\568\ hospital-acquired infection (HAI) or hospital-acquired condition (HAC),\569\ false-positive Central Line