Policy Replication

Time-series hyperpolarized xenon-129 MRI of lobar lung ventilation of COPD in comparison to V/Q-SPECT/CT and CT

Ozkan Doganay, Tahreema Matin, Mitchell Chen, Minsuok Kim, Anthony McIntyre, Daniel R. McGowan, Kevin Martin Bradley, Thomas Povey, Fergus Vincent Gleeson
2018 · European Radiology · article · doi:10.1007/s00330-018-5888-y · 54 scholarly citations

Cited in 1 place in policy documents

Medicare Program; Hospital Inpatient Prospective Payment Systems for Acute Care Hospitals and the Long-Term Care Hospital Prospective Payment System and Proposed Policy Changes and Fiscal Year 2023 Rates; Quality Programs and Medicare Promoting Interoperability Program Requirements for Eligible Hospitals and Critical Access Hospitals; Costs Incurred for Qualified and Non-Qualified Deferred Compensation Plans; and Changes to Hospital and Critical Access Hospital Conditions of Participation

Federal Register2022-05-10 · DEPARTMENT OF HEALTH AND HUMAN SERVICES; Centers for Medicare & Medicaid Services · fn 568
Doganay O, Matin T, Chen M, et al. Time-series hyperpolarized xenon-129 MRI of lobar lung ventilation of COPD in comparison to V/Q-SPECT/CT and CT. Eur Radiol. 2019;29:4058-4067.
The applicant also provided additional evidence of HP \129\Xe's quantitative measurement of pulmonary function from Doganay et al.\568\ in which HP \129\Xe MRI was compared to PFT imaging standards relied upon by pulmonologists when following patients recommended for pharmacologic therapy.