Policy Replication

Procedural and anatomical predictors of renal denervation efficacy using two radiofrequency renal denervation catheters in a porcine model

Milan Anton Wolf, Brad S. Hubbard, Atsushi Sakaoka, Serge D. Rousselle, Armando Téllez, Xiongjing Jiang, Kazuomi Kario, Mathias Hohl, Michael Böhm, Felix Mahfoud
2018 · Journal of Hypertension · article · doi:10.1097/hjh.0000000000001840 · 18 scholarly citations

A free copy is available at the open-access link. Its license does not let us host the file here.

Cited in 1 place in policy documents

Medicare and Medicaid Programs: Hospital Outpatient Prospective Payment and Ambulatory Surgical Center Payment Systems; Quality Reporting Programs, Including the Hospital Inpatient Quality Reporting Program; Health and Safety Standards for Obstetrical Services in Hospitals and Critical Access Hospitals; Prior Authorization; Requests for Information; Medicaid and CHIP Continuous Eligibility; Medicaid Clinic Services Four Walls Exceptions; Individuals Currently or Formerly in Custody of Penal Authorities; Revision to Medicare Special Enrollment Period for Formerly Incarcerated Individuals; and All-Inclusive Rate Add-On Payment for High-Cost Drugs Provided by Indian Health Service and Tribal Facilities

Federal Register2024-11-27 · DEPARTMENT OF HEALTH AND HUMAN SERVICES; Centers for Medicare & Medicaid Services · fn 67
Wolf, M., et al. (2018). Procedural and anatomical predictors of renal denervation efficacy using two radiofrequency renal denervation catheters in a porcine model. Journal of Hypertension, 36(12), 2453-2459.
The applicant also clarified that regarding ablation depth, cadaveric studies found that >90 percent of the renal nerves lie within 6.39 mm of the arterial lumen.\66\ While the applicant stated that it cannot independently confirm the 1-6 mm ablation depth cited for the Paradise[supreg] Ultrasound RDN System, a histological study of radiofrequency RDN in porcine models using the Symplicity SpyralTM RDN System found a comparable mean lesion depth of 6.26 mm (+/- 1.62) in the main renal segment.\67\ The Symplicity SpyralTM RDN System applicant also stated that regardless of modality, ablation depth is not uniform and occurs asymmetrically as a result of heating different tissue types surrounding the renal artery (given the presence of other organs surrounding the renal artery, and anatomical variability between patients, this heat energy is variably dissipated).