Development and testing of a new protocol for evaluating the effectiveness of oil spill surface washing agents
Publisher page (DOI)OpenAlex record
Cited in 1 place in policy documents
National Oil and Hazardous Substances Pollution Contingency Plan
Koran, K.M., Venosa, A.D., Luedeker, C.C., Dunnigan, K., Sorial, G.A., 2009. Development and Testing of a New Protocol for Evaluating the Effectiveness of Oil Spill Surface Washing Agents. Mar. Pollut. Bull., 58: 1903-1908.
The proposed revisions respond to concerns regarding their frequent use and the potential for residual impacts after their use. (1) Surface Washing Agent Efficacy Current Requirements: There are currently no efficacy testing requirements in the NCP Subpart J for surface washing agents to determine listing eligibility on the Schedule. Proposed Revisions: The Agency is developing a laboratory testing protocol to evaluate the efficacy of SWAs in removing crude oil from a solid substrate.\51\ Currently available efficacy testing protocols for these agents are concerned with assessing the detergency, or cleaning power, of the agents by quantifying the physical removal of oil from non-vegetative substrates as a result of their use.