NESHAP: National Emission Standards for Hazardous Air Pollutants: Standards for Hazardous Air Pollutants for Hazardous Waste Combustors
Federal Register2006-03-23 · ENVIRONMENTAL PROTECTION AGENCY · Proposed Rule · 06-2703
Proposed rule.
On October 12, 2005, EPA promulgated national emission standards for hazardous air pollutants (NESHAP) for new and existing hazardous waste combustors. Subsequently, the Administrator received four petitions for reconsideration of the final rule. In this proposed rule, EPA is granting reconsideration of one issue in the petitions submitted by Ash Grove Cement Company and the Cement Kiln Recycling Coalition: The new source standard for particulate matter (PM) for cement kilns that burn hazardous waste. We are requesting comment on a revised new source particulate matter standard for cement kilns. We are also requesting comment on corresponding changes to the new source particulate matter standards for incinerators and liquid fuel boilers.
Original sourceXML (72 KB)PDF (180 KB)
Other documents for the same rulemaking (all, by stage)
References: 11 extracted, 0 linked to papers
Page 1Download these results: CSV · JSON
It is important to note that the UVF relationship is not developed for each source category, but is based on relevant data from all hazardous waste combustor source categories. 70 FR at 59459-450 and “Technical Support Document for HWC MACT Standards, Volume III: Selection of MACT Standards,” September 2005, Sections 5.3 and 7.4. Therefore, changes in the data underlying the UVF relationship can result in changes to the particulate matter standards for all source categories.
research reportNot linked to a paper · footnote
See USEPA, “Draft Technical Support Document for HWC MACT Standards, Volume III: Selection of MACT Standards,” March 2004, Appendix F (APCD Approach Results Tables), Table APCD-CK-PM, docket item EPA-HQ-OAR-2004-0022-0039.
research reportNot linked to a paper · footnote
See USEPA, “Response to Comments on April 20, 2004 HWC MACT Proposed Rule, Volume I: MACT Issues,” September 2005, Section 1.3.3, docket item EPA-HQ-OAR-0022-0440.
research reportNot linked to a paper · footnote
For an evaluation of the additional data submitted by the petitioners, see USEPA, “Draft Technical Support Document for HWC MACT Standards—Reconsideration of the New Source Particulate Matter Standard for Cement Kilns,” March 2006.
research reportNot linked to a paper · footnote
USEPA, “Technical Support Document for the HWC MACT Standards, Volume I: Description of Source Categories,” September 2005, Section 3.2.2.
research reportNot linked to a paper · footnote
USEPA, “Technical Support Document for HWC MACT Standards, Volume III: Selection of MACT Standards,” September 2005, Sections 5.3 and 7.4, docket item EPA-HQ-OAR-2004-0022-0453.
research reportNot linked to a paper · footnote
USEPA, “Draft Technical Support Document for HWC MACT Standards—Reconsideration of the Particulate Matter Standard,” January 2006, Section 4.0.
research reportNot linked to a paper · footnote
The floor methodology used for particulate matter is explained in “Technical Support Document for HWC MACT Standards, Volume III: Selection of MACT Standards,” September 2005, Sections 5.3 and 7.4, docket item EPA-HQ-OAR-2004-0022-0453.
research reportNot linked to a paper · footnote
We note that two other MACT pool sources with fabric filters achieve emission levels comparable to Ash Grove Chanute but have a higher standard deviation. Thus, Ash Grove's fabric filter performs like a MACT pool fabric filter and should be retained in the UVF analysis. Ash Grove Chanute has an emission average of 0.0038 gr/dscf and a standard deviation of 0.0025, while another cement kiln has an emission average of 0.0034 gr/dscf and a standard deviation of 0.0028, and a liquid fuel boiler has an emission average of 0.0037 gr/dscf and a standard deviation of 0.0043. If we were to delete Ash Grove Chanute from the UVF pool nonetheless, the UVF would change slightly and would result in one additional change to the particulate matter floors—the existing source standard for liquid fuel boilers would change from 0.035 gr/dscf to 0.034 gr/dscf. See USEPA, “Draft Technical Support Document for HWC MACT Standards—Reconsideration of the Particulate Matter Standard,” January 2006, Section 4.3.
research reportNot linked to a paper · footnote
For a discussion of how the UVF relationship would be altered and for a presentation of the floor results, see USEPA, “Draft Technical Support Document for HWC MACT Standards—Reconsideration of the New Source Particulate Matter Standard for Cement Kilns,” March 2006, Section 4.0.
research reportNot linked to a paper · footnote
USEPA, “Draft Technical Support Document for HWC MACT Standards—Reconsideration of the New Source Particulate Matter Standard for Cement Kilns,” March 2006.
research reportNot linked to a paper · footnote