Policy Replication

2009-08-18 Technical Support Documentation

Regulatory impact analysis2011-04-26 · EERE · technical_support_document · EERE-2006-STD-0125-0079
RIN 1904-AB58 · Docket EERE-2006-STD-0125

Other documents for the same rulemaking (all, by stage)

2006-06-28 Federal RegisterEnergy Conservation Standards for Refrigerated Bottled or Canned Beverage Vending Machines: Public Meeting and Availability of the Framework Document
2008-06-16 Federal RegisterEnergy Conservation Program: Energy Conservation Standards for Refrigerated Bottled or Canned Beverage Vending Machines
2009-05-29 Federal RegisterEnergy Conservation Program: Energy Conservation Standards for Refrigerated Bottled or Canned Beverage Vending Machines
2009-08-31 Federal RegisterEnergy Conservation Program: Energy Conservation Standards for Refrigerated Bottled or Canned Beverage Vending Machines
2009-09-08 Federal RegisterEnergy Conservation Program: Energy Conservation Standards for Refrigerated Bottled or Canned Beverage Vending Machines
2011-04-12 Regulatory impact analysis2008-06-10 TSD Webpage Screenshots
2011-04-14 Regulatory impact analysis2009-05-21 TSD Webpage Screenshot
2011-04-14 Regulatory impact analysis2009-06-02 Letter to Attorney General Eric Holder asking him to review the NOPR document; original included CD-ROM with a copy of the TSD and the NOPR (cross reference comments EERE-2006-BT-STD-0125-0053 and EERE-2006-BT-STD-0125-0004)

References: 74 extracted, 0 linked to papers

Page 2Download these results: CSV · JSON
Refrigerating, and Air-Conditioning Engineers (ASHRAE) Standard 32.1-20041 is an industry-developed test procedure for determining the energy consumption of beverage vending machines. ASHRAE 32.1-2004 measures the daily energy consumption for a vending machine under steady-state conditions. The use of daily energy consumption as a performance metric is an appropriate approach for refrigerated beverage vending machines for several reasons.
research reportNot linked to a paper · refsec
ANSI/ASHRAE Standard 32.1-2004, Methods of Testing for Rating Vending Machines for
research reportNot linked to a paper · refsec
Bottled, Canned, and Other Sealed Beverages. 2004. Atlanta, GA.
research reportNot linked to a paper · refsec
McGarrah, B. Personal communication. USA Technologies, Malvern, PA. May 2007. TMY2S National Renewable Energy Laboratory. Typical Meteorological Years Derived from the 1961-1990 National Solar Radiation Database. 1995. Golden, CO. U.S. Census Bureau–Census. 2000. (Last accessed on March 25, 2007.) <http://factfinder.census.gov/servlet/GCTTable?_bm=y&-geo_id=01000US&­ _box_head_nbr=GCT-PH1&-context=gct&-ds_name=DEC_2000_SF1_U&­ tree_id=4001&-format=US-9> 7-14 BVM_FINAL_FR_TSD_Chapter7_08-14-09.doc
datasetNot linked to a paper · refsec · cited link
EERE-2006-STD-0125 COMMENT 74 CHAPTER 6. MARKUPS FOR EQUIPMENT PRICE DETERMINATION
research reportNot linked to a paper · refsec
Heating Equipment Industry. 2004. Lawrence Berkeley National Laboratory: Berkeley, CA. Report No. LBNL-52791. 3. M. Metoyer as reported in M. Skaer. What Should You Charge? Try These Tested Formulas. Air Conditioning, Heating and Refrigerator News. March 26, 2001. 4. U.S. Census Bureau. 2002 Economic Census Release Date: 12/3/2004 Sector 42: Wholesale Trade: Industry Series: Product Lines by Kind of Business for the United States: 2002 <http://factfinder.census.gov/servlet/IBQTable?_bm=y&­
research reportNot linked to a paper · refsec · cited link
5. Pindyck R. and D. Rubinfield. Microeconomics. 2000. Prentice-Hall. 6. The Sales Tax Clearinghouse. <https://thestc.com/STRates.stm> (Last accessed on June 4, 2009.) 6-10 BVM_FINAL_FR_TSD_Chapter6_08-14-09.doc
research reportNot linked to a paper · refsec · cited link
EERE-2006-STD-0125 COMMENT 74 CHAPTER 5. ENGINEERING ANALYSIS
research reportNot linked to a paper · refsec
EERE-2006-STD-0125 COMMENT 74 LIST OF TABLES Table 5.3.1 Major Manufacturing Processes .............................................................................. 5-4 Table 5.3.2 Calculated Core Case MSP ...................................................................................... 5-4 Table 5.4.1 Performance Details for “Class A Lighting” Design Option ................................... 5-8 Table 5.4.2 Performance Details for “Class B Lighting” Design Option ................................... 5-9 Table 5.4.3 Performance Details for “Evaporator Fan Motor” Design Option .......................... 5-9 Table 5.4.4 Performance Details for “Improved Class A Evaporator Coil” Design Option .... 5-10 Table 5.4.5 Performance Details for “Improved Class B Evaporator Coil” Design Option .... 5-10
datasetNot linked to a paper · refsec
Little, A. D. Energy Savings Potential for Commercial Refrigeration Equipment, June 1996. Southern California Edison. Next Generation Vending Machine. 2006 ACEEE Summer Study on Energy Efficiency in Buildings. Lawrence Berkley National Laboratory, Window 5.0. <http://windows.lbl.gov/software/window/window.html> American National Standards Institute/American Society of Heating, Refrigeration and Air-Conditioning Engineers. 2004. Standard 32.1-2004: Methods of Testing for Rating Vending Machine for Bottled, Canned, and Other Sealed Beverages. 5-30 BVM_FINAL_FR_TSD_Chapter5_08-14-09.doc
research reportNot linked to a paper · refsec · cited link
EERE-2006-STD-0125 COMMENT 74 CHAPTER 4. SCREENING ANALYSIS
research reportNot linked to a paper · refsec
INTRODUCTION This chapter addresses the screening analysis that the U.S. Department of Energy (DOE) conducted in support of the ongoing energy conservation standards rulemakings for refrigerated bottled or canned beverage vending machines. These rulemakings are mandated by the Energy Policy Act of 2005 and are effective for equipment manufactured 3 years after the date of publication of this final rule establishing energy conservation standards. In the market and technology assessment (chapter 3), DOE presented an initial list of technologies that can reduce the energy consumption of refrigerated beverage vending machines. The goal of the screening analysis is to screen out technologies that will not be considered further in the rulemaking analyses. Some of the technologies considered in chapter 3 can reduce annual energy consumption under real-world conditions, but may not reduce daily energy consumption (DEC), as measured by the American National Standards Institute/American Society of Heating, Refrigerating and Air-Conditioning Engineers (ANSI/ASHRAE) Standard 32.1–2004, Methods of Testing for Rating Vending Machines for Bottled, Canned, and Other Sealed Beverages. DOE removed from consideration those technologies that do not reduce DEC.
research reportNot linked to a paper · refsec
EERE-2006-STD-0125 COMMENT 74 the standard, then that technology will be considered practicable to manufacture, install, and service. Adverse impacts on equipment utility or equipment availability. If DOE determines that a technology has significant adverse impact on the utility of the equipment to significant subgroups of consumers, or result in the unavailability of any covered equipment type with performance characteristics (including reliability), features, sizes, capacities, and volumes that are substantially the same as equipment generally available in the United States at the time, it will not be considered further. Adverse impacts on health or safety. If DOE determines that a technology will have significant adverse impacts on health or safety, it will not be considered further. In sum, if DOE determines that a technology or combination of technologies has unacceptable effects on the policies stated in section 5(b) of the Process Rule, those technologies will be eliminated from consideration. If a particular technology fails to meet one or more of the four criteria, it will be screened out. Section 4.3 below documents the reasons for eliminating any technology.
research reportNot linked to a paper · refsec
Houghton, D. 1996. “Refrigerated Vending Machines – Overlooked Devices Hold Opportunities for Efficiency, New Services”, Tech Update TU-96-7, E Source, Inc., Boulder, Colorado American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc. (ASHRAE) Handbook “2006 Refrigeration”, ASHRAE, Atlanta, GA. Underwriters Laboratories (UL) Standard 541-2003, Refrigerated Vending Machines. American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc.(ASHRAE), 2004. Methods of Testing for Rating Vending Machines for
journal articleNot linked to a paper · refsec
Bottled, Canned, and Other Sealed Beverages, ANSI/ASHRAE 32.1-2004.
research reportNot linked to a paper · refsec
ANSI/Association of Home Appliance Manufacturers (AHAM). 2004. Energy, Performance and Capacity of Household Refrigerators, Refrigerator-Freezers and Freezers. ANSI/AHAM HRF-1-2004. Energy Star 2007,ENERGY STAR Program Requirements for Refrigerated Beverage Vending Machines Eligibility Criteria Version 2.0. <http://www.energystar.gov/index.cfm?c=vending_machines.pr_vending_machin
research reportNot linked to a paper · refsec · cited link
California Energy Commission. 2006. “Appliance Efficiency Regulations,” CEC­ 400-2006-002 Rev. 2[1] Report No: 2008/10 Minimum Energy Performance Standard: Refrigerated Beverage Vending Machines, National Appliance and Equipment Energy Efficiency Program (NAEEEC). <http://www.energyrating.gov.au/library/pubs/200810-ris-vending.pdf> National Automatic Merchandising Association, <http://www.vending.org> American Beverage Association. < http://www.ameribev.org/index.aspx?>
research reportNot linked to a paper · refsec · cited link
Arthur D. Little, Inc., Energy Savings Potential for Commercial Refrigeration Equipment. U.S. Department of Energy, June 1996. Small Business Administration, November 2006. <http://www.sba.gov/gopher/Financial-Assistance/Size­ Standards/sizetablestandards.txt>
research reportNot linked to a paper · refsec · cited link
Faramarzi, R. and Mitchell, S. 2006. “Next Generation Vending Machine”, Southern California Edison report. 3-28 BVM_FINAL_FR_TSD_Chapter3_08-14-09.doc
research reportNot linked to a paper · refsec
EERE-2006-STD-0125 COMMENT 74 U.S. Department of Energy. 2005. FY2006 Appliance Standards Program Priority-Setting Summary Report and Actions Proposed,” Beverage Vending Machines – Energy Saving Potential Estimates, DOE (October 2005)
research reportNot linked to a paper · refsec
Nadel, S. 2002. “Packaged commercial refrigeration equipment: A briefing report for program planners and implementers”, Report Number A022, American Council for an Energy-Efficient Economy, Washington, D.C. California Energy Commission, Appliances Database. (Last Accessed July 11, 2007) <http://www.energy.ca.gov/appliances/appliance/excel_based_files/>
datasetNot linked to a paper · refsec · cited link
ENERGY STAR, New Machine Product List. (Last Accessed July 11, 2007) <http://www.energystar.gov/ia/products/prod_lists/vending_prod_list.pdf> Lighting Resource Center, LRC, Ramesh Raghavan and Nadarajah Narendran, Refrigerated Display Case Lighting with LEDs, Lighting Research Center,
datasetNot linked to a paper · refsec · cited link
Rensselaer Polytechnic Institute, 2002 Solid State Lighting II: proceeding of the Society of Photo-Optical Instrumentation Engineers. “Single-phase Electric Motors,” November 2006. <http://www.iprocessmart.com/leeson/leeson_singlephase_article.htm> U.S. Department of Energy. “Technical Support Document for Energy Conservation Standards for Room Air Conditioners.” September 1997. “Investigation of Energy-Efficient Supermarket Display Cases,” Oak Ridge National Laboratory, December 2004. 3-29 BVM_FINAL_FR_TSD_Chapter3_08-14-09.doc
research reportNot linked to a paper · refsec · cited link
EERE-2006-STD-0125 COMMENT 74 CHAPTER 2. ANALYTICAL FRAMEWORK
research reportNot linked to a paper · refsec
← Previous