Policy Replication

National Primary Drinking Water Regulations for Lead and Copper: Improvements (LCRI)

Federal Register2024-10-30 · ENVIRONMENTAL PROTECTION AGENCY · Rule · 2024-23549
Final rule.

In December 2023, the U.S. Environmental Protection Agency (EPA) requested comment on the proposed the Lead and Copper Rule Improvements (LCRI), which informed the revisions to the National Primary Drinking Water Regulation (NPDWR) for lead and copper. After consideration of public comment on the LCRI, and consistent with the provisions set forth under the Safe Drinking Water Act (SDWA), the EPA is finalizing revisions to the NPDWR for lead and copper. In this rule, the agency is finalizing requirements for drinking water systems to replace lead and certain galvanized service lines. The final rule also removes the lead trigger level, reduces the lead action level to 0.010 mg/L, and strengthens tap sampling procedures to improve public health protection and simplify implementation relative to the 2021 Lead and Copper Rule Revisions (LCRR). Further, this final rule strengthens corrosion control treatment, public education and consumer awareness, requirements for small systems, and sampling in schools and child care facilities. The final rule will significantly reduce the adverse human health impacts of exposure to toxic lead in drinking water.

RIN 2040-AG16 · Docket EPA-HQ-OW-2022-0801

Other documents for the same rulemaking (all, by stage)

2023-12-06 Federal RegisterNational Primary Drinking Water Regulations for Lead and Copper: Improvements (LCRI)
2023-12-06 Regulatory impact analysisDoshi et al. (2012) Economic Impact of Childhood and Adult Attention-Deficit Hyperactivity Disorder in the United States, Journal Article
2023-12-06 Regulatory impact analysisUSEPA (2023) Analysis of the Economic Impacts of the Proposed Consumer Confidence Reports Rule Revisions
2023-12-06 Regulatory impact analysisUSEPA (2012) Economic Analysis for the Final Revised Total Coliform Rule. Economic Analysis. Document number EPA 815-R-12-004
2023-12-06 Regulatory impact analysisUSEPA (2020) Economic Analysis Appendices for the Final Lead and Copper Rule Revisions, Report
2023-12-06 Regulatory impact analysisUSEPA (2020) Economic Analysis for the Final Lead and Copper Rule Revisions, Report
2023-12-06 Regulatory impact analysisUSEPA (2006) Economic Analysis for the Final Ground Water Rule. Economic Analysis.
2023-12-06 Regulatory impact analysisUSEPA (2014) Guidelines for Preparing and Economic Analyses. Guidance.
2023-12-06 Regulatory impact analysisUSEPA (2019) Economic Analysis of the Final Rule to Revise the TSCA Dust-Lead Hazard Standards, Report
2023-12-06 Regulatory impact analysisUSEPA (2019) Economic Analysis for the Proposed Lead and Copper Rule Revisions. Economic Analysis.
2023-12-06 Regulatory impact analysisUSEPA (2007) Economic and Supporting Analyses: Short-Term Regulatory Changes to the Lead and Copper Rule. Economic Analysis.
2023-12-06 Regulatory impact analysisUSEPA (2016) Technical Guidance for Assessing Environmental Justice in Regulatory Analysis, Report
2023-12-06 Regulatory impact analysisUSEPA (2023) Economic Analysis for the Proposed Lead and Copper Rule Improvements, Report
2023-12-06 Docket documentEO 12866 (1993) Regulatory Planning and Review, Executive Order
2023-12-06 Docket documentDocumentation of OMB Review Under Executive Order 12866 for the Proposed Rule - Proposed National Primary Drinking Water Regulations for Lead and Copper: Improvements
2024-10-30 Regulatory impact analysisUSEPA (2023). Regulatory Impact Analysis for Standards of Performance for New, Reconstructed, and Modified Sources and Emissions Guidelines for Existing Sources: Oil and Natural Gas Sector Climate Review. EPA-452/R-23-013. December 2023.
2024-10-30 Regulatory impact analysisUSEPA (2023) Regulatory Impact Analyses for Air Pollution Regulations. Website
2024-10-30 Regulatory impact analysisUSEPA (2008). Regulatory Impact Analysis of the Proposed Revisions to the National Ambient Air Quality Standards for Lead. Benefits Analysis Approach and Results, Chapter 5. October 2008.
2024-10-30 Regulatory impact analysisGeier et al. (2018). A cross-sectional study of the relationship between blood lead levels and reported attention deficit disorder: An assessment of the economic impact on the United States. Journal Article.
2024-10-30 Regulatory impact analysisUSEPA (2024). EPA’s 2024 Economic Assessment Updated Soil Lead Guidance for Sites and Facilities Being Addressed Under CERCLA and RCRA Authorities. January 2024.
2024-10-30 Regulatory impact analysisScience Advisory Board (SAB) (2017) SAB Advice on the Use of Economy-Wide Models in Evaluating the Social Costs, Benefits, and Economic Impacts of Air Regulations. September 29, 2017. EPA-SAB-17-012
2024-10-30 Regulatory impact analysisUSEPA (2024) Economic Analysis for the Final Per- and Polyfluoroalkyl Substances National Primary Drinking Water Regulation. April 2024. EPA 815-R-24-001
2024-10-30 Regulatory impact analysisUSEPA (2024) Economic Analysis of the Final Consumer Confidence Report Rule Revisions. May 2024. 816-R-24-001
2024-10-30 Regulatory impact analysisE2 (2021) Getting the Lead Out: Employment & Economic Impacts from Replacing America's Lead Pipes. Report
2024-10-30 Regulatory impact analysisUSEPA (2024). Economic Analysis for the Final Lead and Copper Rule Improvements. Report
2024-10-30 Docket documentOMB. (2023). Circular A-4
2024-10-30 Docket documentUSEPA (2024) Documentation of OMB Review Under Executive Order 12866 for the Final Rule: "National Primary Drinking Water Regulations for Lead and Copper: Improvements". Note to the File

References: 195 extracted, 85 linked to papers

Page 2Download these results: CSV · JSON
Park, Y., and Han, J. (2021). Blood lead levels and cardiovascular disease risk: Results from the Korean National Health and Nutrition Examination Survey. Int J Environ Res Public Health, 18: 10315.
Department of Health and Human Services (HHS) National Toxicology Program (NTP) Monograph on Health Effects of Low-Level Lead (NTP, 2012), the Agency for Toxic Substances and Disease Registry (ATSDR) 2020 Toxicological Profile for Lead (ATSDR, 2020), and peer-reviewed studies have documented associations between lead and cancer (Wei and Zhu, 2020) as well as lead and adverse cardiovascular (Park and Han, 2021), renal (Harari et al., 2018), reproductive (Shi et al., 2021; Lee et al., 2020), immunological (Krueger and Wade, 2016), and neurological effects (Andrew et al., 2022).
Proctor, C.R., Rhoads, W.J., Keane, T., et al. (2020). Considerations for large building water quality after extended stagnation. Journal AWWA, 2(4): 1186.
This is because, even when large buildings are served by a water system with well-operated OCCT, they may have lead in drinking water due to lead in premise plumbing, larger and more complex plumbing configurations, and inconsistent water use patterns (e.g., summer, holiday, or other breaks) that can result in longer stagnation times (88 FR 84956, USEPA, 2023a; Barn et al., 2014; Deshommes et al., 2016; Proctor et al., 2020).
Reese, A.C, Burgos-Gil, R., Cleary, S.D., et al. (2023). Use of a Water Filter at Home Reduces Sugary Drink Consumption among Parents and Infants/Toddlers in a Predominantly Hispanic Community: Results from the Water Up!@Home Intervention Trial. Journal of the Academy of Nutrition and Dietetics, 123(1): 41-51.
When filters or point-of-use devices and instructions on their proper use are made more accessible, consumers are more likely to use them (Reese et al., 2023; Mulhern et al., 2022).
Rockey, N.C., Shen, Y., Haig, S.J., et al. (2021). Impact of service line replacement on lead, cadmium, and other drinking water quality parameters in Flint, Michigan. Environmental Science: Water Research & Technology, 7(4): 797-808.
However, while removal of LSLs is critical to reducing lead in drinking water, premise plumbing materials also continue to be a source of lead in drinking water (Elfland, 2010; Kimbrough, 2007; Rockey et al., 2021).
Roy, S. and Edwards, M.A. (2020). Efficacy of corrosion control and pipe replacement in reducing citywide lead exposure during the Flint, MI water system recovery. Environmental Science: Water Research & Technology, 2020(6): 3024-3031.
Additionally, the EPA identified research which continues to show that CCT effectively reduces lead and copper from leaching into drinking water (Hayes and Hydes, 2012; Roy and Edwards, 2020; Tam and Elefsiniotis, 2009; Vijayashanthar et al., 2023).
Rodosthenous, RS et al. (2017). Prenatal lead exposure and fetal growth: Smaller infants have heightened susceptibility. Environ Int 99: 228-233.
Studies document increased risk of miscarriage (Xu et al., 2012; Tolunay et al., 2016), low birth weight (Goto et al., 2021; Hu et al., 2021; Rodosthenous et al., 2017; Taylor et al., 2015), and preterm birth (USEPA, 2024b; Fisher et al., 2023).
Sandvig, A., P. Kwan, G. Kirmeyer, et al. (2008). Contribution of Service Line and Plumbing Fixtures to Lead and Copper Rule Compliance Issues. Denver, Colo.: Awwa Research Foundation.
research reportNot linked to a paper · reference list
Schock, M., Hyland, R., and Welch, M. (2008). Occurrence of Contaminant Accumulation in Lead Pipe Scales from Domestic Drinking-Water Distribution Systems. Environmental Science and Technology, 42(12): 4285-4291.
Literature shows that these types of challenges continue to be a factor in applying CCT (e.g., Schock et al., 2008). In addition, the EPA is aware that some water systems may lack the expertise to design and implement CCT without assistance from outside technical experts and the State, particularly smaller water systems.
Schwartz, J., and Otto, D. (1991). Lead and minor hearing impairment. Archives of Environmental and Occupational Health, 46(5): 300-305.
journal articleLead and Minor Hearing Impairment (1991) · reference list
No threshold has been identified for the neurological effects of lead (Budtz-J[oslash]rgensen et al., 2013; Crump et al., 2013; Schwartz et al., 1991; USEPA, 2013).
Shi, X., Chan, C.P.S., Man, G.K.Y., et al. (2021). Associations between blood metal/metalloid concentration and human semen quality and sperm function: A cross-sectional study in Hong Kong. J Trace Elem Med Biol, 65: 126735.
Department of Health and Human Services (HHS) National Toxicology Program (NTP) Monograph on Health Effects of Low-Level Lead (NTP, 2012), the Agency for Toxic Substances and Disease Registry (ATSDR) 2020 Toxicological Profile for Lead (ATSDR, 2020), and peer-reviewed studies have documented associations between lead and cancer (Wei and Zhu, 2020) as well as lead and adverse cardiovascular (Park and Han, 2021), renal (Harari et al., 2018), reproductive (Shi et al., 2021; Lee et al., 2020), immunological (Krueger and Wade, 2016), and neurological effects (Andrew et al., 2022).
Slabaugh, R.M., R.B. Arnold, S. Chaparro, and C.P. Hill. (2015). National Cost Implications of Potential Long-Term LCR Requirements. Journal American Water Works Association, 107(8):E389-E400.
An analysis of LCR compliance data in Slabaugh et al. (2015) that compared lead 90th percentile values from samples collected from all LSL sites to lead 90th percentiles from samples collected from both lead and non-LSL sites was used to develop an adjustment ratio to account for the requirement introduced in the 2021 LCRR and retained in the final LCRI that LSL systems collect all samples from LSL sites where possible.
Smart, P., McRae, L., Formal, C., and Lytle, D.A. (2023). Development and optimization of a systematic approach to identifying lead service lines: One community's success. Water Research, 246.
In addition, a 2023 study on the accuracy of service line identification methods found that, of the 159 control homes, records for 90 percent of the 99 known LSL sites were accurate, whereas records for 3 percent of the 60 non-lead service line sites accurately identified the service line material (Smart et al., 2023).
Stanek, L.W., J. Xue, C.R. Lay, et al. (2020). Modeled impacts of drinking water Pb reduction scenarios on children's exposures and blood lead levels. Environmental Science and Technology, 54(15): 9474-9482.
Infants who consume mostly formula mixed with tap water can, depending on the level of lead in the water and other sources of lead in the home, receive 40 to 60 percent of their exposure to lead from drinking water used in the formula (53 FR 31516, USEPA, 1988; Stanek et al., 2020).
St. Clair, J., Cartier, C., Triantafyllidou, T., Clark, B., and Edwards, M. (2016). Long-Term Behavior of Simulated Partial Lead Service Line Replacements. Environmental Engineering Science, 33(1): 53-64.
Stratton, S., Ettinger, A., Doherty, C., and Buckley, B. (2023). The lead and copper rule: Limitations and lessons learned from Newark, New Jersey. WIRES Water, 10(1).
Sweeney, S. (2020). Central Arkansas Water's Lead Service Line Replacement Program: Investigation, Communication, Implementation. Journal AWWA, 112(4): 32-38.
A 10-year replacement program for this system would lead to approximately 12 service line replacements per year, which is less efficient and could lead to an increased need of resources considering replacement crews would be needed over a much longer period of time (Sweeney, 2020; Central Arkansas Water, 2022). In addition to failure to meet the ``feasibility'' requirements in the statute, a shorter mandatory replacement deadline in the final LCRI would likely result in a greater number of water systems seeking exemptions from the treatment technique requirements.
Tam, Y.S., and Elefsiniotis, P. (2009). Corrosion control in water supply systems: Effect of pH, alkalinity, and orthophosphate on lead and copper leaching from brass plumbing. Journal of Environmental Science and Health Part A, 44(12): 1251-1260.
Additionally, the EPA identified research which continues to show that CCT effectively reduces lead and copper from leaching into drinking water (Hayes and Hydes, 2012; Roy and Edwards, 2020; Tam and Elefsiniotis, 2009; Vijayashanthar et al., 2023).
Tang, M., Lytle, D., Achtemeier, R., and Tully, J. (2023). Reviewing performance of NSF/ANSI 53 certified water filters for lead removal. Water Research, 244: 120425.
In addition, recent filter effectiveness studies conducted by the EPA have shown that properly installed and operated filters certified by an ANSI accredited certifier to reduce lead are effective at reducing lead in drinking water (Bosscher et al., 2019; Tang et al., 2023; Tully et al., 2023).
Taylor, CM; Golding, J; Emond, AM. (2015). Adverse effects of maternal lead levels on birth outcomes in the ALSPAC study: A prospective birth cohort study. BJOG, 122: 322-328.
Studies document increased risk of miscarriage (Xu et al., 2012; Tolunay et al., 2016), low birth weight (Goto et al., 2021; Hu et al., 2021; Rodosthenous et al., 2017; Taylor et al., 2015), and preterm birth (USEPA, 2024b; Fisher et al., 2023).
Triantafyllidou, S., Parks, J., and Edwards, M. (2007). Lead Particles in Potable Water. Journal AWWA, 99(6): 107-117.
journal articleLead Particles in Potable Water (2007) · reference list
Furthermore, lead particulates can be released sporadically or as a result of service line disturbances even in systems that have well-operated OCCT and have measured generally low lead levels (Del Toral et al., 2013; Triantafyllidou et al., 2007).
Triantafyllidou, S., and Edwards, M. (2011). Galvanic corrosion after simulated small-scale partial lead service line replacements. Journal AWWA, 103(9): 85-99.
A dielectric coupling between the replaced line and the partial lead or GRR service line reduces the risks of galvanic corrosion between lead and other metallic pipes that causes lead release as documented in previous lab-scale studies (DeSantis et al., 2018; Triantafyllidou and Edwards, 2011; Wang et al., 2012).
Triantafyllidou, Simoni & Edwards, Marc. (2012). Lead (Pb) in Tap Water and in Blood: Implications for Lead Exposure in the United States. Critical Reviews in Environmental Science and Technology, 42: 1297-1352.
For example, brass particles and lead solder particles were identified as the cause of severe tap water contaminations during three field investigations in North Carolina and Washington, DC (Triantafyllidou and Edwards, 2012).
Triantafyllidou, S., M. Schock, M.K. DeSantis, and C. White. (2015). Low contribution of PbO2-coated lead service lines to water lead contamination at the tap. Environmental Science & Technology, 49(6): 3746-3754.
Studies show that lead levels can widely vary at a single site depending on the sampling protocol (Del Toral et al., 2013; Lytle et al., 2019; Lytle et al., 2021; Masters et al., 2021; Triantafyllidou et al., 2015).
Triantafyllidou, S., Burkhardt, J., Tully, J., et al. (2021). Variability and Sampling of Lead (Pb) in Drinking water: Assessing Potential Human Exposure Depends on the Sampling Protocol. Environment International, 146:106259.
Studies continue to show that the levels of lead and copper measured at the tap after treatment are variable due to several factors including, but not limited to, the amount of lead in any individual site's plumbing, the age of plumbing components, the physical and chemical characteristics of the water, the length of time water is in contact with material, and consumer water use patterns (Triantafyllidou et al., 2021).
Trueman, B.F., Camara, E., and Gagnon, G.A. (2016). Evaluating the Effects of Full and Partial Lead Service Line Replacement on Lead Levels in Drinking Water. Environmental Science & Technology, 50(14): 7389-7396.
Replacing lead and GRR service lines has been shown to significantly reduce lead levels in drinking water (Camara et al., 2013; Deshommes et al., 2018; Trueman et al., 2016), which improves public health by reducing the associated health impacts from lead exposures. The LCR only requires water systems to replace LSLs systemwide if a system exceeds the lead action level and allows them to stop replacements once their 90th percentile lead level is below the lead action level.
Tully, J., DeSantis, M.K., and Schock, M.R. (2019). Water quality-pipe deposit relationships in Midwestern lead pipes. AWWA Water Science, 1(2): e1127.
For example, studies indicate that CCT can reduce drinking water lead levels at the tap (Cardew, 2009; Hayes et al., 2008; Tully et al., 2019).
Tully, J., Schilling, S., Bosscher, V., Schock, M., and Lytle, D. (2023). Benton Harbor Drinking Water Study. U.S. Environmental Protection Agency, EPA/600/R-22/269.
research reportNot linked to a paper · reference list
U.S. Census Bureau. (2015b). Income and Poverty in the United States: 2015.
datasetNot linked to a paper · reference list
Vijayashanthar, V., Small, M.J., and Van Briesen, J.M. (2023). Assessment of Lead in Drinking Water from Multiple Drinking Water Sampling Programs for a Midsize City. Environmental Science & Technology, 57: 842-851.
Additionally, the EPA identified research which continues to show that CCT effectively reduces lead and copper from leaching into drinking water (Hayes and Hydes, 2012; Roy and Edwards, 2020; Tam and Elefsiniotis, 2009; Vijayashanthar et al., 2023).
Wang, Y., Jing, H., Mehta, V., Welter, G.J., and Giammar, D.E. (2012). Impact of galvanic corrosion on lead release from aged lead service lines. Water Research, 46(16): 5049-5060.
A dielectric coupling between the replaced line and the partial lead or GRR service line reduces the risks of galvanic corrosion between lead and other metallic pipes that causes lead release as documented in previous lab-scale studies (DeSantis et al., 2018; Triantafyllidou and Edwards, 2011; Wang et al., 2012).
Wang, Y., Mehta, V., Welter, G., and Giammar, D. (2013). Effect of connection methods on lead release from galvanic corrosion. Journal AWWA, 105(7): E337-E351.
Clair et al., 2016; Wang et al., 2013), demonstrating the value of requiring the insertion of such couplings.
Wei, YD; Zhu, JM. (2020). Blood levels of endocrine-disrupting metals and prevalent breast cancer among US women. Med Oncol 37: 1.
Department of Health and Human Services (HHS) National Toxicology Program (NTP) Monograph on Health Effects of Low-Level Lead (NTP, 2012), the Agency for Toxic Substances and Disease Registry (ATSDR) 2020 Toxicological Profile for Lead (ATSDR, 2020), and peer-reviewed studies have documented associations between lead and cancer (Wei and Zhu, 2020) as well as lead and adverse cardiovascular (Park and Han, 2021), renal (Harari et al., 2018), reproductive (Shi et al., 2021; Lee et al., 2020), immunological (Krueger and Wade, 2016), and neurological effects (Andrew et al., 2022).
Xie, Y., Giammar, D.E. (2011). Effects of flow and water chemistry on lead release rates from pipe scales. Water Research, 45(19), 6525-6534.
Even when using the same sampling protocol, variation in lead at a single site can still occur due to water use patterns and highly variable release of particulate lead (Clark et al., 2014; Masters et al., 2016; Xie and Giammar, 2011). As described in the proposed LCRI, the EPA analyzed lead data from the dataset collected for the Six-Year Review 4 (2012 to 2019) for systems with different characteristics (e.g., CCT and LSL status) to further evaluate how lead and copper levels at the tap can vary.
Xu, XJ et al. (2012). Birth outcomes related to informal e-waste recycling in Guiyu, China. Reprod Toxicol, 33: 94-98.
Studies document increased risk of miscarriage (Xu et al., 2012; Tolunay et al., 2016), low birth weight (Goto et al., 2021; Hu et al., 2021; Rodosthenous et al., 2017; Taylor et al., 2015), and preterm birth (USEPA, 2024b; Fisher et al., 2023).
Zartarian, V., J. Xue, R. Tornero-Velez, and J. Brown. (2017). Children's Lead Exposure: A multimedia Modeling Analysis to Guide Public Health Decision-Making. Environmental Health Perspectives, 125(9).
For further information on SHEDS-Pb model development and evaluation, refer to Zartarian et al. (2017).
Zhu, M., Fitzgerald, E.F., Gelberg, K.H., Lin, S., and Druschel, C.M. (2010). Maternal low-level lead exposure and fetal growth. Environmental Health Perspectives, 118(10), 1471-1475.
Ziegler, E.E., B.B. Edwards, R.L. Jensen, K.R. Mahaffey, and S.J. Fomon. (1978). Absorption and retention of lead by infants. Pediatric Research, 12(1):29-34.
Additionally, children absorb two to four times more lead than adults through the gastrointestinal tract (Mushak, 1991; WHO, 2011; and Ziegler et al., 1978).
Cardew, 2009
otherNot linked to a paper · Section IV.A (Corrosion control treatment discussion)
Hayes et al., 2008
otherNot linked to a paper · Section IV.A (Corrosion control treatment discussion)
Tully et al., 2019
otherNot linked to a paper · Section IV.A (Corrosion control treatment discussion)
Deshommes et al., 2017
otherNot linked to a paper · Section IV.B.2.a (Mandatory Service Line Replacement rationale)
Trueman et al., 2016
otherNot linked to a paper · Section IV.B.2.a (Mandatory Service Line Replacement rationale)
Edwards and Dudi, 2004
otherNot linked to a paper · Section IV.B.2.a (Mandatory Service Line Replacement rationale)
Lytle et al., 2020
otherNot linked to a paper · Section IV.B.2.a (Mandatory Service Line Replacement rationale)
Sarver, 2019
otherNot linked to a paper · Section IV.B.2.a (Mandatory Service Line Replacement rationale)
Masters et. al, 2021
otherNot linked to a paper · Section IV.B.2.a (Mandatory Service Line Replacement rationale)
Del Toral et al., 2013
otherNot linked to a paper · Section IV.B.2.a (Mandatory Service Line Replacement rationale)
Triantafyllidou et al., 2007
otherNot linked to a paper · Section IV.B.2.a (Mandatory Service Line Replacement rationale)
Triantafyllidou and Edwards, 2012
otherNot linked to a paper · Section IV.B.2.a (Mandatory Service Line Replacement rationale)
McFadden et al., 2011
otherNot linked to a paper · Section IV.B.2.a.i (Scope of Mandatory Service Line Replacement)
← PreviousNext →