{"document":{"doc_id":77069,"source":"fr_rule","org":"DEPARTMENT OF ENERGY","doc_type":"Rule","title":"Energy Conservation Program: Energy Conservation Standards for Distribution Transformers","date":"2024-04-22","url":"https://www.federalregister.gov/documents/2024/04/22/2024-07480/energy-conservation-program-energy-conservation-standards-for-distribution-transformers","source_native_id":"2024-07480","status":"fetched","abstract":"The Energy Policy and Conservation Act, as amended (EPCA), prescribes energy conservation standards for various consumer products and certain commercial and industrial equipment, including distribution transformers. EPCA also requires the U.S. Department of Energy (DOE) to periodically review its existing standards to determine whether more stringent standards would be technologically feasible and economically justified, and would result in significant energy savings. In this final rule, DOE is adopting amended energy conservation standards for distribution transformers. It has determined that the amended energy conservation standards for these products would result in significant conservation of energy, and are technologically feasible and economically justified.","action":"Final rule."},"dockets":["EERE-2019-BT-STD-0018"],"rins":["RIN 1904-AE12"],"related":[{"doc_id":83624,"source":"ria","org":"EERE","doc_type":"technical_support_document","title":"2021-08  Technical Support Document: Energy Efficiency Program For Commercial And Industrial Equipment: Distribution Transformers, August 2021","date":"2021-08-20"},{"doc_id":77217,"source":"fr_rule","org":"DEPARTMENT OF ENERGY","doc_type":"Proposed Rule","title":"Energy Conservation Program: Energy Conservation Standards for Distribution Transformers, Webinar and Availability of the Preliminary Technical Support Document","date":"2021-08-27"},{"doc_id":83651,"source":"ria","org":"EERE","doc_type":"technical_support_document","title":"2021-08-27  Energy Conservation Program: Energy Conservation Standards for Distribution Transformers, Webinar and Availability of the Preliminary Technical Support Document; Notification of a webinar and availability of preliminary technical support document","date":"2021-08-27"},{"doc_id":77211,"source":"fr_rule","org":"DEPARTMENT OF ENERGY","doc_type":"Proposed Rule","title":"Energy Conservation Program: Energy Conservation Standards for Distribution Transformers, Webinar and Availability of the Preliminary Technical Support Document","date":"2021-11-16"},{"doc_id":83631,"source":"ria","org":"EERE","doc_type":"technical_support_document","title":"2021-11-16  Energy Conservation Program: Energy Conservation Standards for Distribution Transformers, Webinar and Availability of the Preliminary Technical Support Document; Reopening of public comment\nperiod","date":"2021-11-16"},{"doc_id":83644,"source":"ria","org":"EERE","doc_type":"technical_support_document","title":"2022-12  Technical Support Document: Energy Efficiency Program for Consumer Products and Commercial and Industrial Equipment:  Distribution Transformers, December 2022","date":"2022-12-28"},{"doc_id":77122,"source":"fr_rule","org":"DEPARTMENT OF ENERGY","doc_type":"Proposed Rule","title":"Energy Conservation Program: Energy Conservation Standards for Distribution Transformers","date":"2023-01-11"},{"doc_id":128297,"source":"docket_item","org":"EERE","doc_type":"review_record","title":"Documentation of Changes between the draft Notice of Proposed Rulemaking (NOPR) and announcement of public meeting submitted to the Office of Information and Regulatory Affairs (OIRA) and Notice of Proposed Rulemaking (NOPR) and announcement of public meeting subsequently announced","date":"2023-01-23"},{"doc_id":77117,"source":"fr_rule","org":"DEPARTMENT OF ENERGY","doc_type":"Proposed Rule","title":"Energy Conservation Program: Energy Conservation Standards for Distribution Transformers; Extension of Public Comment Period","date":"2023-02-22"},{"doc_id":22266,"source":"ria","org":"DEPARTMENT OF ENERGY","doc_type":"regulatory_impact_analysis","title":"RIA cited in FR 2023-03436: Energy Conservation Program: Energy Conservation Standards for Refrigerators, Refrigerator-Freezers, and Freezers","date":"2023-02-27"},{"doc_id":22267,"source":"ria","org":"DEPARTMENT OF ENERGY","doc_type":"regulatory_impact_analysis","title":"RIA cited in FR 2023-03436: Energy Conservation Program: Energy Conservation Standards for Refrigerators, Refrigerator-Freezers, and Freezers","date":"2023-02-27"},{"doc_id":22270,"source":"ria","org":"DEPARTMENT OF ENERGY","doc_type":"regulatory_impact_analysis","title":"RIA cited in FR 2023-03436: Energy Conservation Program: Energy Conservation Standards for Refrigerators, Refrigerator-Freezers, and Freezers","date":"2023-02-27"},{"doc_id":83638,"source":"ria","org":"EERE","doc_type":"technical_support_document","title":"2024-04  Technical Support Document:  Energy Efficiency Program for Consumer Products and Commercial and Industrial Equipment:  Distribution Transformers, April 2024","date":"2024-04-04"},{"doc_id":22030,"source":"ria","org":"ENVIRONMENTAL PROTECTION AGENCY","doc_type":"regulatory_impact_analysis","title":"RIA cited in FR 2024-21967: Phasedown of Hydrofluorocarbons: Management of Certain Hydrofluorocarbons and Substitutes Under the American Innovation and Manufacturing Act of 2020","date":"2024-10-11"}],"references":[{"citation_id":456309,"raw_reference":"Yahoo Finance, Howard Industries cuts ribbon on Quitman plant, November 3, 2023, Available online at: https://finance.yahoo.com/news/howard-industries-cuts-ribbon-quitman-035900515.html.","cited_authors":null,"cited_year":"2023","cited_title":"Howard Industries cuts ribbon on Quitman plant","cited_venue":"Yahoo Finance","cited_doi":null,"cited_url":"https://finance.yahoo.com/news/howard-industries-cuts-ribbon-quitman-035900515.html","ref_kind":"news","section":"fn 199","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":456310,"raw_reference":"JFE Shoji Power, \"What Got Us Here Won't Get Us to Where We Want to Go\", You Will Be an Embarrassment to the Company, Nov. 2023. https://www.amazon.in/What-Here-Wont-Where-Want/dp/B0CMD84HRW.","cited_authors":"JFE Shoji Power","cited_year":"2023","cited_title":"What Got Us Here Won't Get Us to Where We Want to Go","cited_venue":"You Will Be an Embarrassment to the Company","cited_doi":null,"cited_url":"https://www.amazon.in/What-Here-Wont-Where-Want/dp/B0CMD84HRW","ref_kind":"book","section":"fn 200","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":456311,"raw_reference":"Worthington Steel, Investor Day, Oct. 2023, Transcript. Available online at: worthington-steel-investor-day-transcript-final-10-11-23.pdf (worthingtonenterprises.com.)","cited_authors":"Worthington Steel","cited_year":"2023","cited_title":"Investor Day Transcript","cited_venue":"Worthington Steel","cited_doi":null,"cited_url":"worthingtonenterprises.com","ref_kind":"other","section":"fn 201","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":456312,"raw_reference":"The 2007 \"Energy Conservation Standards Rulemaking Peer Review Report\" is available at the following website: energy.gov/eere/buildings/downloads/energy-conservation-standards-rulemaking-peer-review-report-0","cited_authors":"U.S. Department of Energy","cited_year":"2007","cited_title":"Energy Conservation Standards Rulemaking Peer Review Report","cited_venue":"U.S. Department of Energy","cited_doi":null,"cited_url":"energy.gov/eere/buildings/downloads/energy-conservation-standards-rulemaking-peer-review-report-0","ref_kind":"government_report","section":"fn 206","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":458533,"raw_reference":"IEEE SA. (2022). IEEE C57.12.34-2023—IEEE Standard Requirements for Pad Mounted, Compartmental-Type, Self-Cooled, Three-Phase Distribution Transformers, 10 MVA and Smaller; High-Voltage, 34.5 kV Nominal System Voltage and Below; Low-Voltage, 15 kV Nominal System Voltage and Below. Available at https://standards.ieee.org/ieee/C57.12.34/6863/ (last accessed Nov. 8, 2021).","cited_authors":"IEEE SA","cited_year":"2022","cited_title":"IEEE C57.12.34-2023—IEEE Standard Requirements for Pad Mounted, Compartmental-Type, Self-Cooled, Three-Phase Distribution Transformers, 10 MVA and Smaller; High-Voltage, 34.5 kV Nominal System Voltage and Below; Low-Voltage, 15 kV Nominal System Voltage and Below","cited_venue":"IEEE","cited_doi":null,"cited_url":"https://standards.ieee.org/ieee/C57.12.34/6863/","ref_kind":"other","section":"fn 54","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":458534,"raw_reference":"Y. Okazaki, Loss deterioration in amorphous cores for distribution transformer, Journal of Magnetism and Magnetic Materials 160 (1996) 217-222.","cited_authors":"Y. Okazaki","cited_year":"1996","cited_title":"Loss deterioration in amorphous cores for distribution transformer","cited_venue":"Journal of Magnetism and Magnetic Materials","cited_doi":"10.1016/0304-8853(96)00211-9","cited_url":null,"ref_kind":"journal_article","section":"fn 87","page":null,"context_sentence":"10-11) DOE notes that both the study cited by APPA and the original 1996 study \\87\\ are referring to degradation in the process of forming an amorphous core from amorphous ribbon (i.e.","paper_id":30520,"paper_title":"Loss deterioration in amorphous cores for distribution transformers","paper_year":1996,"paper_doi":"10.1016/0304-8853(96)00211-9"},{"citation_id":458535,"raw_reference":"Bonneville Power Administration, Amorphous Core Liquid Immersed Distribution Transformers. 2020.","cited_authors":"Bonneville Power Administration","cited_year":"2020","cited_title":"Amorphous Core Liquid Immersed Distribution Transformers","cited_venue":"Bonneville Power Administration","cited_doi":null,"cited_url":"www.bpa.gov/-/media/Aep/energy-efficiency/emerging-technologies/liquid-immersed-amorphous-core-distribution-transformers-2020-03-31-final.pdf","ref_kind":"research_report","section":"fn 75","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":458536,"raw_reference":"Bonneville Power Administration, Low-Voltage Liquid Immersed Amorphous Core Distribution Transformers. 2022.","cited_authors":"Bonneville Power Administration","cited_year":"2022","cited_title":"Low-Voltage Liquid Immersed Amorphous Core Distribution Transformers","cited_venue":"Bonneville Power Administration","cited_doi":null,"cited_url":"www.bpa.gov/-/media/Aep/energy-efficiency/emerging-technologies/ET-Documents/liquid-immersed-dist-transformers-final-22-0216.pdf","ref_kind":"research_report","section":"fn 77","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":458537,"raw_reference":"Metglas, Amorphous Metal Distribution Transformers. 2016.","cited_authors":"Metglas","cited_year":"2016","cited_title":"Amorphous Metal Distribution Transformers","cited_venue":"Metglas","cited_doi":null,"cited_url":"metglas.com/wp-content/uploads/2021/06/Metglas-Power-Brochure-Updated.pdf","ref_kind":"web_page","section":"fn 76","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":458538,"raw_reference":"ABB, Distribution goes green. Available at library.e.abb.com/public/f28b7caf32af14e8c1257a25002f2717/40-47%202m221_EN_72dpi.pdf (last accessed Nov. 9, 2023).","cited_authors":"ABB","cited_year":null,"cited_title":"Distribution goes green","cited_venue":"ABB","cited_doi":null,"cited_url":"library.e.abb.com/public/f28b7caf32af14e8c1257a25002f2717/40-47%202m221_EN_72dpi.pdf","ref_kind":"web_page","section":"fn 82","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":458539,"raw_reference":"Metglas, Inc. Recycling of Amorphous Transformer Cores, 2010.","cited_authors":"Metglas, Inc.","cited_year":"2010","cited_title":"Recycling of Amorphous Transformer Cores","cited_venue":"Metglas","cited_doi":null,"cited_url":"metglas.com/recycling-amorphous-transformer-cores/","ref_kind":"web_page","section":"fn 83","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":458540,"raw_reference":"U.S. Department of Commerce, The Effect of Imports of Transformers and Transformer Components on the National Security. (2020).","cited_authors":"U.S. Department of Commerce","cited_year":"2020","cited_title":"The Effect of Imports of Transformers and Transformer Components on the National Security","cited_venue":"U.S. Department of Commerce","cited_doi":null,"cited_url":"www.bis.doc.gov/index.php/documents/section-232-investigations/2790-redacted-goes-report-20210723-ab-redacted/file","ref_kind":"government_report","section":"fn 90","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":458541,"raw_reference":"Markham, I., ERMCO CEO: For an Effective Outcome, Focus on Inputs, The Wall Street Journal, Jan. 5, 2024.","cited_authors":"Markham, I.","cited_year":"2024","cited_title":"ERMCO CEO: For an Effective Outcome, Focus on Inputs","cited_venue":"The Wall Street Journal","cited_doi":null,"cited_url":"https://deloitte.wsj.com/riskandcompliance/ermco-ceo-for-an-effective-outcome-focus-on-inputs-3ecfbeff","ref_kind":"news","section":"fn 91","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":458542,"raw_reference":"U.S. Bureau of Labor Statistics, Producer Price Index by Industry: PPI industry data for Electric power and specialty transformer mfg, not seasonally adjusted.","cited_authors":"U.S. Bureau of Labor Statistics","cited_year":null,"cited_title":"Producer Price Index by Industry: Electric power and specialty transformer mfg","cited_venue":"U.S. Bureau of Labor Statistics","cited_doi":null,"cited_url":"https://www.bls.gov/ppi/databases/","ref_kind":"dataset","section":"fn 104","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":458543,"raw_reference":"Metal Miner, Global M3 Price Index. November 2023.","cited_authors":"Metal Miner","cited_year":"2023","cited_title":"Global M3 Price Index","cited_venue":"Metal Miner","cited_doi":null,"cited_url":"agmetalminer.com/metal-prices/grain-oriented-electrical-steel/","ref_kind":"dataset","section":"fn 106","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":460267,"raw_reference":"Dalah, S., Aswani, D., Geraghty, M., Dunckley, J., Impact of Increasing Replacement Transformer Size on the Probability of Transformer Overloads with Increasing EV Adoption, 36th International Electric Vehicle Symposium and Exhibition, June, 2023.","cited_authors":"Dalah, S., Aswani, D., Geraghty, M., Dunckley, J.","cited_year":"2023","cited_title":"Impact of Increasing Replacement Transformer Size on the Probability of Transformer Overloads with Increasing EV Adoption","cited_venue":"36th International Electric Vehicle Symposium and Exhibition","cited_doi":null,"cited_url":"https://evs36.com/wp-content/uploads/finalpapers/FinalPaper_Dahal_Sachindra.pdf","ref_kind":"conference_paper","section":"fn 53","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":460268,"raw_reference":"Hammond Power Solutions. Autotransformers, 2023.","cited_authors":"Hammond Power Solutions","cited_year":"2023","cited_title":"Autotransformers","cited_venue":"Hammond Power Solutions","cited_doi":null,"cited_url":"documents.hammondpowersolutions.com/documents/Literature/Specialty/HPS-Autotransformers-Brochure.pdf","ref_kind":"web_page","section":"fn 40","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":460269,"raw_reference":"Pacific Northwest National Lab and U.S. Department of Energy (2016), \"Electricity Distribution System Baseline Report.\"","cited_authors":"Pacific Northwest National Lab; U.S. Department of Energy","cited_year":"2016","cited_title":"Electricity Distribution System Baseline Report","cited_venue":"U.S. Department of Energy","cited_doi":null,"cited_url":"www.energy.gov/sites/prod/files/2017/01/f34/Electricity%20Distribution%20System%20Baseline%20Report.pdf","ref_kind":"research_report","section":"fn 45","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":460270,"raw_reference":"U.S. Department of Energy (2015), \"United States Electricity Industry Primer.\"","cited_authors":"U.S. Department of Energy","cited_year":"2015","cited_title":"United States Electricity Industry Primer","cited_venue":"U.S. Department of Energy","cited_doi":null,"cited_url":"www.energy.gov/sites/prod/files/2015/12/f28/united-states-electricity-industry-primer.pdf","ref_kind":"research_report","section":"fn 46","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":460271,"raw_reference":"IEEE SA. (2020). IEEE C57.12.91-2020—IEEE Standard Test Code for Dry-Type Distribution and Power Transformers.","cited_authors":"IEEE SA","cited_year":"2020","cited_title":"IEEE C57.12.91-2020—IEEE Standard Test Code for Dry-Type Distribution and Power Transformers","cited_venue":"IEEE","cited_doi":null,"cited_url":"standards.ieee.org/standard/C57_12_91-2020.html","ref_kind":"other","section":"fn 47","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":460272,"raw_reference":"IEEE SA. (1998). IEEE 449-1998—IEEE Standard for Ferroresonant Voltage Regulators.","cited_authors":"IEEE SA","cited_year":"1998","cited_title":"IEEE 449-1998—IEEE Standard for Ferroresonant Voltage Regulators","cited_venue":"IEEE","cited_doi":null,"cited_url":"standards.ieee.org/ieee/449/675/","ref_kind":"other","section":"fn 42","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":460273,"raw_reference":"U.S. EPA. Estimating the Benefit per Ton of Reducing Directly Emitted PM2.5, PM2.5 Precursors and Ozone Precursors from 21 Sectors.","cited_authors":"U.S. EPA","cited_year":null,"cited_title":"Estimating the Benefit per Ton of Reducing Directly Emitted PM2.5, PM2.5 Precursors and Ozone Precursors from 21 Sectors","cited_venue":"U.S. Environmental Protection Agency","cited_doi":null,"cited_url":"www.epa.gov/benmap/estimating-benefit-ton-reducing-pm25-precursors-21-sectors","ref_kind":"research_report","section":"fn 11","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":460274,"raw_reference":"Official Journal of the European Union, Commission Regulation (EU) No. 548/2014, May 21, 2014","cited_authors":"European Commission","cited_year":"2014","cited_title":"Commission Regulation (EU) No. 548/2014","cited_venue":"Official Journal of the European Union","cited_doi":null,"cited_url":"eur-lex.europa.eu/legal-content/EN/TXT/?uri=uriserv%3AOJ.L_.2014.152.01.0001.01.ENG","ref_kind":"other","section":"fn 49","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":461088,"raw_reference":"Prolec GE, No. 120 at p. 12; NEMA, No. 141 at p. 15","cited_authors":"Prolec GE; NEMA","cited_year":null,"cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"other","section":"Section IV.F.3.b Total Owning Cost and Evaluators","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":461089,"raw_reference":"Gordian, RSMeans Online, www.rsmeans.com/products/online (last accessed Sept. 2023).","cited_authors":"Gordian","cited_year":"2023","cited_title":"RSMeans Online","cited_venue":"Gordian","cited_doi":null,"cited_url":"www.rsmeans.com/products/online","ref_kind":"dataset","section":"fn 163","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":461090,"raw_reference":"Barnes, P. R., Van Dyke, J. W., McConnell, B. W. & Das, S. Determination Analysis of Energy Conservation Standards for Distribution Transformers. (Oak Ridge National Laboratory, 1996).","cited_authors":"Barnes, P. R.; Van Dyke, J. W.; McConnell, B. W.; Das, S.","cited_year":"1996","cited_title":"Determination Analysis of Energy Conservation Standards for Distribution Transformers","cited_venue":"Oak Ridge National Laboratory","cited_doi":"10.2172/405744","cited_url":null,"ref_kind":"research_report","section":"fn 165","page":null,"context_sentence":"Transformer Service Lifetime For distribution transformers, DOE used a distribution of lifetimes, with an estimated average of 32 years and a maximum of 60 years.\\165\\ 78 FR 23336, 23377.","paper_id":52465,"paper_title":"Determination analysis of energy conservation standards for distribution transformers","paper_year":1996,"paper_doi":"10.2172/405744"},{"citation_id":461091,"raw_reference":"Dahal, S, Aswami D, Geraghty M, Dunckley, J. Impact of Increasing Replacement Transformer Sizing on the Probability of Transformer Overloads with Increasing EV Adoptions. 36th International Electric Vehicle Symposium and Exhibition Sacramento. California, USA, June 2023.","cited_authors":"Dahal, S; Aswami D; Geraghty M; Dunckley, J","cited_year":"2023","cited_title":"Impact of Increasing Replacement Transformer Sizing on the Probability of Transformer Overloads with Increasing EV Adoptions","cited_venue":"36th International Electric Vehicle Symposium and Exhibition","cited_doi":null,"cited_url":null,"ref_kind":"conference_paper","section":"fn 168","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":461092,"raw_reference":"Livingston, O. V., S. R. Bender, M. J. Scott, and R. W. Schultz. ImSET 4.0: Impact of Sector Energy Technologies Model Description and User's Guide. 2015. Pacific Northwest National Laboratory: Richland, WA. PNNL-24563.","cited_authors":"Livingston, O. V.; Bender, S. R.; Scott, M. J.; Schultz, R. W.","cited_year":"2015","cited_title":"ImSET 4.0: Impact of Sector Energy Technologies Model Description and User's Guide","cited_venue":"Pacific Northwest National Laboratory","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"Section IV.N Employment Impact Analysis, fn 192","page":null,"context_sentence":null,"paper_id":15669,"paper_title":"ImSET 3.1: Impact of Sector Energy Technologies Model Description and User's Guide","paper_year":2009,"paper_doi":"10.2172/962848"},{"citation_id":461093,"raw_reference":"Marten, A.L., E.A. Kopits, C.W. Griffiths, S.C. Newbold, and A. Wolverton. Incremental CH4 and N2O mitigation benefits consistent with the U.S. Government's SC-CO2 estimates. Climate Policy. 2015. 15(2): pp. 272-298.","cited_authors":"Marten, A.L.; Kopits, E.A.; Griffiths, C.W.; Newbold, S.C.; Wolverton, A.","cited_year":"2015","cited_title":"Incremental CH4 and N2O mitigation benefits consistent with the U.S. Government's SC-CO2 estimates","cited_venue":"Climate Policy","cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"Section IV.L.1 fn 184","page":null,"context_sentence":null,"paper_id":10228,"paper_title":"Incremental CH4and N2O mitigation benefits consistent with the US Government's SC-CO2estimates","paper_year":2014,"paper_doi":"10.1080/14693062.2014.912981"},{"citation_id":461094,"raw_reference":"National Academies of Sciences, Engineering, and Medicine. Valuing Climate Damages: Updating Estimation of the Social Cost of Carbon Dioxide. 2017. The National Academies Press: Washington, DC.","cited_authors":"National Academies of Sciences, Engineering, and Medicine","cited_year":"2017","cited_title":"Valuing Climate Damages: Updating Estimation of the Social Cost of Carbon Dioxide","cited_venue":"The National Academies Press","cited_doi":"10.17226/24651","cited_url":"nap.nationalacademies.org/catalog/24651/valuing-climate-damages-updating-estimation-of-the-social-cost-of","ref_kind":"book","section":"Section IV.L.1 fn 185","page":null,"context_sentence":null,"paper_id":3819,"paper_title":"Valuing Climate Changes: Updating Estimation of the Social Cost of Carbon Dioxide","paper_year":2017,"paper_doi":"10.17226/24651"},{"citation_id":461095,"raw_reference":"Interagency Working Group on Social Cost of Greenhouse Gases. 2021. Technical Support Document: Social Cost of Carbon, Methane, and Nitrous Oxide Interim Estimates under Executive Order 13990. February. United States Government.","cited_authors":"Interagency Working Group on Social Cost of Greenhouse Gases","cited_year":"2021","cited_title":"Technical Support Document: Social Cost of Carbon, Methane, and Nitrous Oxide Interim Estimates under Executive Order 13990","cited_venue":"United States Government","cited_doi":null,"cited_url":"www.whitehouse.gov/briefing-room/blog/2021/02/26/a-return-to-science-evidence-based-estimates-of-the-benefits-of-reducing-climate-pollution/","ref_kind":"government_report","section":"Section IV.L.1 fn 187","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":461096,"raw_reference":"U.S. EPA. (2023). Supplementary Material for the Regulatory Impact Analysis for the Final Rulemaking, Standards of Performance for New, Reconstructed, and Modified Sources and Emissions Guidelines for Existing Sources: Oil and Natural Gas Sector Climate Review: EPA Report on the Social Cost of Greenhouse Gases: Estimates Incorporating Recent Scientific Advances.","cited_authors":"U.S. EPA","cited_year":"2023","cited_title":"EPA Report on the Social Cost of Greenhouse Gases: Estimates Incorporating Recent Scientific Advances","cited_venue":"U.S. EPA","cited_doi":null,"cited_url":"https://www.epa.gov/controlling-air-pollution-oil-and-natural-gas-operations/epas-final-rule-oil-and-natural-gas","ref_kind":"government_report","section":"Section IV.L.1 fn 183","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":461341,"raw_reference":"Toyo Electric, “Dry-type Amorphous core transformer.” Available at www.toyo-elec.co.jp/en/products/dry-type-amorphous-core-transformer/ (last accessed Oct. 2023).","cited_authors":"Toyo Electric","cited_year":"2023","cited_title":"Dry-type Amorphous core transformer","cited_venue":null,"cited_doi":null,"cited_url":"www.toyo-elec.co.jp/en/products/dry-type-amorphous-core-transformer/","ref_kind":"web_page","section":"fn 112","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":461342,"raw_reference":"Chu Lei Electric Co., “Amorphous Transformers.” Available online at: www.powertransformer.com.tw/en/amorphous-transformers.html (last accessed Oct. 2023).","cited_authors":"Chu Lei Electric Co.","cited_year":"2023","cited_title":"Amorphous Transformers","cited_venue":null,"cited_doi":null,"cited_url":"www.powertransformer.com.tw/en/amorphous-transformers.html","ref_kind":"web_page","section":"fn 113","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":461343,"raw_reference":"DeCristofaro, N., Amorphous Metals in Electric-Power Distribution Applications, Material Research Society, MRS Bulletin, Volume 23, Number 5, 1998.","cited_authors":"DeCristofaro, N.","cited_year":"1998","cited_title":"Amorphous Metals in Electric-Power Distribution Applications","cited_venue":"MRS Bulletin, Material Research Society","cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"fn 125","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":461344,"raw_reference":"BPA's Emerging Technologies Initiative, Phase 1 report: High Efficiency Distribution Transformer Technology Assessment, April 2020.","cited_authors":"Bonneville Power Administration","cited_year":"2020","cited_title":"Phase 1 report: High Efficiency Distribution Transformer Technology Assessment","cited_venue":"Bonneville Power Administration","cited_doi":null,"cited_url":"www.bpa.gov/EE/NewsEvents/presentations/Documents/Transformer%20webinar%204-7-20%20Final.pdf","ref_kind":"research_report","section":"fn 126","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":461345,"raw_reference":"Congressional Research Service, Section 232 Investigations: Overview and Issues for Congress, May 18, 2021, Available at fas.org/sgp/crs/misc/R45249.pdf.","cited_authors":"Congressional Research Service","cited_year":"2021","cited_title":"Section 232 Investigations: Overview and Issues for Congress","cited_venue":"Congressional Research Service","cited_doi":null,"cited_url":"fas.org/sgp/crs/misc/R45249.pdf","ref_kind":"research_report","section":"fn 128","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":461346,"raw_reference":"Wolfram, Catherine. Measuring Duopoly Power in the British Electricity Spot Market. American Economic Review. 89 (4) 805-826. 1999.","cited_authors":"Wolfram, Catherine","cited_year":"1999","cited_title":"Measuring Duopoly Power in the British Electricity Spot Market","cited_venue":"American Economic Review","cited_doi":"10.1257/aer.89.4.805","cited_url":null,"ref_kind":"journal_article","section":"fn 143","page":null,"context_sentence":"For example, in an alternative energy industry context it has been empirically shown that duopoly markups are lower than economic theory might otherwise predict, due to issues associated with protecting against additional market entrants and imperfect information.\\143\\ --------------------------------------------------------------------------- ---------------------------------------------------------------------------","paper_id":48631,"paper_title":"Measuring Duopoly Power in the British Electricity Spot Market","paper_year":1999,"paper_doi":"10.1257/aer.89.4.805"},{"citation_id":461347,"raw_reference":"K. McKenna et al: Major Drivers of Long-Term Distribution Transformer Demand, Feb 2024, NREL/TP-6A40-87653.","cited_authors":"McKenna, K. et al.","cited_year":"2024","cited_title":"Major Drivers of Long-Term Distribution Transformer Demand","cited_venue":"National Renewable Energy Laboratory","cited_doi":"10.2172/2309697","cited_url":null,"ref_kind":"research_report","section":"fn 141","page":null,"context_sentence":"A report \\141\\ by the National Renewable Energy Laboratory estimates future growth in stock between 160 and 260 percent by 2050 for distribution transformers, including step-up transformers which are not in the scope of DOE's rulemaking, but it shows consistent projections regarding future growth.","paper_id":52480,"paper_title":"Major Drivers of Long-Term Distribution Transformer Demand","paper_year":2024,"paper_doi":"10.2172/2309697"},{"citation_id":461348,"raw_reference":"Jodie Lupton, Right-Sizing Residential Transformers for EVs, T&D World, January 2024.","cited_authors":"Lupton, Jodie","cited_year":"2024","cited_title":"Right-Sizing Residential Transformers for EVs","cited_venue":"T&D World","cited_doi":null,"cited_url":"https://prismic-io.s3.amazonaws.com/wwwpowerengcom/9dd90ffc-4df8-442c-92c2-eb175f687ea0_Right-sizing+residential+transformers+for+EVs.pdf","ref_kind":"web_page","section":"fn 155","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null}]}