{"document":{"doc_id":7039,"source":"fr_rule","org":"NUCLEAR REGULATORY COMMISSION","doc_type":"Rule","title":"American Society of Mechanical Engineers 2015-2017 Code Editions Incorporation by Reference","date":"2020-05-04","url":"https://www.federalregister.gov/documents/2020/05/04/2020-08855/american-society-of-mechanical-engineers-2015-2017-code-editions-incorporation-by-reference","source_native_id":"2020-08855","status":"fetched","abstract":"The U.S. Nuclear Regulatory Commission (NRC) is amending its regulations to incorporate by reference the 2015 and 2017 Editions of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code and the 2015 and 2017 Editions of the American Society of Mechanical Engineers Operation and Maintenance of Nuclear Power Plants, Division 1: OM Code: Section IST, for nuclear power plants. The NRC is also incorporating by reference two revised American Society of Mechanical Engineers code cases. This action is in accordance with the NRC's policy to periodically update the regulations to incorporate by reference new editions of the American Society of Mechanical Engineers Codes and is intended to maintain the safety of nuclear power plants and to make NRC activities more effective and efficient.","action":"Final rule."},"dockets":["NRC-2016-0082"],"rins":["RIN 3150-AJ74"],"related":[{"doc_id":8136,"source":"fr_rule","org":"NUCLEAR REGULATORY COMMISSION","doc_type":"Proposed Rule","title":"American Society of Mechanical Engineers 2015-2017 Code Editions Incorporation by Reference","date":"2018-11-09"},{"doc_id":6985,"source":"fr_rule","org":"NUCLEAR REGULATORY COMMISSION","doc_type":"Rule (administrative)","title":"American Society of Mechanical Engineers 2015-2017 Code Editions Incorporation by Reference; Correction","date":"2020-06-03"}],"references":[{"citation_id":28423,"raw_reference":"Electric Power Research Institute (EPRI), Topical Report, \"Materials Reliability Program: Topical Report for Primary Water Stress Corrosion Cracking Mitigation by Surface Stress Improvement\" (MRP-335, Revision 3-A)","cited_authors":"Electric Power Research Institute","cited_year":null,"cited_title":"Materials Reliability Program: Topical Report for Primary Water Stress Corrosion Cracking Mitigation by Surface Stress Improvement","cited_venue":"Electric Power Research Institute","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"Executive Summary, B. Major Provisions","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":28424,"raw_reference":"NUREG/CR-7153, \"Expanded Materials Degradation Assessment (EMDA)\"","cited_authors":null,"cited_year":null,"cited_title":"Expanded Materials Degradation Assessment (EMDA)","cited_venue":"U.S. Nuclear Regulatory Commission","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"10 CFR 50.55a(b)(2)(xxi) Section XI Condition: Table IWB-2500-1 Examination Requirements","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":28425,"raw_reference":"NUREG-0619-Rev-1, \"BWR Feedwater Nozzle and Control Rod Drive Return Line Nozzle Cracking: Resolution of Generic Technical Activity A-10 (Technical Report)\"","cited_authors":null,"cited_year":null,"cited_title":"BWR Feedwater Nozzle and Control Rod Drive Return Line Nozzle Cracking: Resolution of Generic Technical Activity A-10","cited_venue":"U.S. Nuclear Regulatory Commission","cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"10 CFR 50.55a(b)(2)(xxi) Section XI Condition: Table IWB-2500-1 Examination Requirements","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":28426,"raw_reference":"NUREG/CR-6933, \"Assessment of Crack Detection in Heavy-Walled Cast Stainless Steel Piping Welds Using Advanced Low-Frequency Ultrasonic Methods\"","cited_authors":null,"cited_year":null,"cited_title":"Assessment of Crack Detection in Heavy-Walled Cast Stainless Steel Piping Welds Using Advanced Low-Frequency Ultrasonic Methods","cited_venue":"U.S. Nuclear Regulatory Commission","cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"10 CFR 50.55a(b)(2)(xxxviii) Section XI Condition: ASME Code Section XI Appendix III Supplement 2","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":28427,"raw_reference":"NUREG/CR-7122, \"An Evaluation of Ultrasonic Phased Array Testing for Cast Austenitic Stainless Steel Pressurizer Surge Line Piping Welds\"","cited_authors":null,"cited_year":null,"cited_title":"An Evaluation of Ultrasonic Phased Array Testing for Cast Austenitic Stainless Steel Pressurizer Surge Line Piping Welds","cited_venue":"U.S. Nuclear Regulatory Commission","cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"10 CFR 50.55a(b)(2)(xxxviii) Section XI Condition: ASME Code Section XI Appendix III Supplement 2","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":28428,"raw_reference":"NUREG/CR-6654, \"A Study of Air-Operated Valves in U.S. Nuclear Power Plants\"","cited_authors":null,"cited_year":null,"cited_title":"A Study of Air-Operated Valves in U.S. Nuclear Power Plants","cited_venue":"U.S. Nuclear Regulatory Commission","cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"10 CFR 50.55a(b)(3) OM Condition","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":28429,"raw_reference":"Technical Basis for Reexamination Interval Extension for Alloy 690 PWR Reactor Vessel Top Head Penetration Nozzles (MRP-375)","cited_authors":null,"cited_year":null,"cited_title":"Technical Basis for Reexamination Interval Extension for Alloy 690 PWR Reactor Vessel Top Head Penetration Nozzles","cited_venue":"Electric Power Research Institute","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"10 CFR 50.55a(g)(6)(ii)(D)(7) Sister Plants","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":28430,"raw_reference":"Recommended Factors of Improvement for Evaluating Primary Water Stress Corrosion Cracking (PWSCC) Growth Rates of Thick-Wall Alloy 690 Materials and Alloy 52, 152, and Variants Welds (MRP-386)","cited_authors":null,"cited_year":null,"cited_title":"Recommended Factors of Improvement for Evaluating Primary Water Stress Corrosion Cracking (PWSCC) Growth Rates of Thick-Wall Alloy 690 Materials and Alloy 52, 152, and Variants Welds","cited_venue":"Electric Power Research Institute","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"10 CFR 50.55a(g)(6)(ii)(D)(7) Sister Plants","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":28431,"raw_reference":"PVP2010-25214, \"Fracture Toughness of Pressure Boundary Steels with Higher Yield Strength\"","cited_authors":null,"cited_year":null,"cited_title":"Fracture Toughness of Pressure Boundary Steels with Higher Yield Strength","cited_venue":"ASME Pressure Vessels and Piping Conference","cited_doi":null,"cited_url":null,"ref_kind":"conference_paper","section":"10 CFR 50.55a(b)(2)(xl) Section XI Condition: Prohibitions on Use of IWB-3510.4(b)","page":null,"context_sentence":null,"paper_id":8735,"paper_title":"Fracture Toughness of Pressure Boundary Steels With Higher Yield Strength","paper_year":2010,"paper_doi":"10.1115/pvp2010-25214"},{"citation_id":31684,"raw_reference":"Generic Aging Lessons Learned (GALL) Report, NUREG-1801, Revision 2 (ADAMS Accession No. ML103490041)","cited_authors":"U.S. Nuclear Regulatory Commission","cited_year":"2010","cited_title":"Generic Aging Lessons Learned (GALL) Report","cited_venue":"NUREG-1801, Rev. 2","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"VI. Generic Aging Lessons Learned Report, Background","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":31685,"raw_reference":"Standard Review Plan for Review of License Renewal Applications for Nuclear Power Plants, NUREG-1800, Revision 2","cited_authors":"U.S. Nuclear Regulatory Commission","cited_year":"2010","cited_title":"Standard Review Plan for Review of License Renewal Applications for Nuclear Power Plants","cited_venue":"NUREG-1800, Rev. 2","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"VI. Generic Aging Lessons Learned Report, Background","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":31686,"raw_reference":"NUREG-1950, \"Disposition of Public Comments and Technical Bases for Changes in the License Renewal Guidance Documents NUREG-1801 and NUREG-1800,\" April 2011","cited_authors":"U.S. Nuclear Regulatory Commission","cited_year":"2011","cited_title":"Disposition of Public Comments and Technical Bases for Changes in the License Renewal Guidance Documents NUREG-1801 and NUREG-1800","cited_venue":"NUREG-1950","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"VI. Generic Aging Lessons Learned Report, Background","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":31687,"raw_reference":"Generic Aging Lessons Learned for Subsequent License Renewal (GALL-SLR) Report, NUREG-2191 (ADAMS Accession Nos. ML17187A031 and ML17187A204)","cited_authors":"U.S. Nuclear Regulatory Commission","cited_year":"2017","cited_title":"Generic Aging Lessons Learned for Subsequent License Renewal (GALL-SLR) Report","cited_venue":"NUREG-2191","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"VI. Generic Aging Lessons Learned Report, Background","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":31688,"raw_reference":"Standard Review Plan for Review of Subsequent License Renewal Applications for Nuclear Power Plants, NUREG-2192","cited_authors":"U.S. Nuclear Regulatory Commission","cited_year":"2017","cited_title":"Standard Review Plan for Review of Subsequent License Renewal Applications for Nuclear Power Plants","cited_venue":"NUREG-2192","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"VI. Generic Aging Lessons Learned Report, Background","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":31689,"raw_reference":"NUREG/CR-6654, \"A Study of Air-Operated Valves in U.S. Nuclear Power Plants,\" February 2000","cited_authors":null,"cited_year":"2000","cited_title":"A Study of Air-Operated Valves in U.S. Nuclear Power Plants","cited_venue":"NUREG/CR-6654","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"Availability of Documents (XVII)","page":null,"context_sentence":null,"paper_id":70017,"paper_title":"A study of air-operated valves in U.S. nuclear power plants","paper_year":2000,"paper_doi":"10.2172/1329395"},{"citation_id":31690,"raw_reference":"NUREG/CR-7153, \"Expanded Materials Degradation Assessment (EMDA),\" October 2014","cited_authors":null,"cited_year":"2014","cited_title":"Expanded Materials Degradation Assessment (EMDA)","cited_venue":"NUREG/CR-7153","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"Availability of Documents (XVII)","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":31691,"raw_reference":"NUREG-0619, Rev. 1, \"BWR Feedwater Nozzle and Control Rod Drive Return Line Nozzle Cracking: Resolution of Generic Technical Activity A-10 (Technical Report),\" November 1980","cited_authors":null,"cited_year":"1980","cited_title":"BWR Feedwater Nozzle and Control Rod Drive Return Line Nozzle Cracking: Resolution of Generic Technical Activity A-10","cited_venue":"NUREG-0619, Rev. 1","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"Availability of Documents (XVII)","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":31692,"raw_reference":"NUREG/CR-6933, \"Assessment of Crack Detection in Heavy-Walled Cast Stainless Steel Piping Welds Using Advanced Low-Frequency Ultrasonic Methods,\" March 2007","cited_authors":null,"cited_year":"2007","cited_title":"Assessment of Crack Detection in Heavy-Walled Cast Stainless Steel Piping Welds Using Advanced Low-Frequency Ultrasonic Methods","cited_venue":"NUREG/CR-6933","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"Availability of Documents (XVII)","page":null,"context_sentence":null,"paper_id":69898,"paper_title":"Assessment of Crack Detection in Heavy-Walled Cast Stainless Steel Piping Welds Using Advanced Low-Frequency Ultrasonic Methods","paper_year":2007,"paper_doi":"10.2172/921260"},{"citation_id":31693,"raw_reference":"NUREG/CR-7122, \"An Evaluation of Ultrasonic Phased Array Testing for Cast Austenitic Stainless Steel Pressurizer Surge Line Piping Welds,\" March 2012","cited_authors":null,"cited_year":"2012","cited_title":"An Evaluation of Ultrasonic Phased Array Testing for Cast Austenitic Stainless Steel Pressurizer Surge Line Piping Welds","cited_venue":"NUREG/CR-7122","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"Availability of Documents (XVII)","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":31694,"raw_reference":"Gupta KK, Hoffmann CL, Hamilton AM, DeLose F. Fracture Toughness of Pressure Boundary Steels With Higher Yield Strength. ASME. ASME Pressure Vessels and Piping Conference, ASME 2010 Pressure Vessels and Piping Conference: Volume 7 ():45-58. doi:10.1115/PVP2010-25214","cited_authors":"Gupta KK, Hoffmann CL, Hamilton AM, DeLose F","cited_year":"2010","cited_title":"Fracture Toughness of Pressure Boundary Steels With Higher Yield Strength","cited_venue":"ASME 2010 Pressure Vessels and Piping Conference: Volume 7","cited_doi":"10.1115/pvp2010-25214","cited_url":"http://proceedings.asmedigitalcollection.asme.org/proceeding.aspx?articleid=1619041","ref_kind":"conference_paper","section":"Availability of Documents (XVII)","page":null,"context_sentence":null,"paper_id":8735,"paper_title":"Fracture Toughness of Pressure Boundary Steels With Higher Yield Strength","paper_year":2010,"paper_doi":"10.1115/pvp2010-25214"},{"citation_id":31695,"raw_reference":"Materials Reliability Program: Topical Report for Primary Water Stress Corrosion Cracking Mitigation by Surface Stress Improvement (MRP-335, Revision 3-A), EPRI approval date: November 2016","cited_authors":"Electric Power Research Institute, Materials Reliability Program","cited_year":"2016","cited_title":"Materials Reliability Program: Topical Report for Primary Water Stress Corrosion Cracking Mitigation by Surface Stress Improvement (MRP-335, Revision 3-A)","cited_venue":"Electric Power Research Institute","cited_doi":null,"cited_url":"https://www.epri.com","ref_kind":"research_report","section":"XIV. Voluntary Consensus Standards","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null}]}