{"document":{"doc_id":6530,"source":"fr_rule","org":"DEPARTMENT OF HEALTH AND HUMAN SERVICES; Centers for Medicare & Medicaid Services","doc_type":"Rule","title":"Medicare Program; End-Stage Renal Disease Prospective Payment System, Payment for Renal Dialysis Services Furnished to Individuals With Acute Kidney Injury, and End-Stage Renal Disease Quality Incentive Program","date":"2020-11-09","url":"https://www.federalregister.gov/documents/2020/11/09/2020-24485/medicare-program-end-stage-renal-disease-prospective-payment-system-payment-for-renal-dialysis","source_native_id":"2020-24485","status":"fetched","abstract":"This final rule updates and makes revisions to the End-Stage Renal Disease (ESRD) Prospective Payment System (PPS) for calendar year (CY) 2021. This rule also updates the payment rate for renal dialysis services furnished by an ESRD facility to individuals with acute kidney injury (AKI). In addition, this rule updates requirements for the ESRD Quality Incentive Program (QIP).","action":"Final rule."},"dockets":["CMS-2020-0079"],"rins":["RIN 0938-AU08"],"related":[{"doc_id":6904,"source":"fr_rule","org":"DEPARTMENT OF HEALTH AND HUMAN SERVICES; Centers for Medicare & Medicaid Services","doc_type":"Proposed Rule","title":"Medicare Program; End-Stage Renal Disease Prospective Payment System, Payment for Renal Dialysis Services Furnished to Individuals With Acute Kidney Injury, and End-Stage Renal Disease Quality Incentive Program","date":"2020-07-13"}],"references":[{"citation_id":26516,"raw_reference":"Medicare Improvements for Patients and Providers Act of 2008 (MIPPA)","cited_authors":null,"cited_year":"2008","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"other","section":"I. Executive Summary","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":27758,"raw_reference":"Boschetti-de-Fierro, A., et al., \"MCO Membranes: Enhanced Selectivity in High-Flux Cases,\" Scientific Reports, 5:18448, DOI 10.1038/srep18448","cited_authors":"Boschetti-de-Fierro, A., et al.","cited_year":"2015","cited_title":"MCO Membranes: Enhanced Selectivity in High-Flux Cases","cited_venue":"Scientific Reports","cited_doi":"10.1038/srep18448","cited_url":null,"ref_kind":"journal_article","section":"fn 77","page":null,"context_sentence":"(2) CMS Analysis (a) Summary of Submitted Evidence of the Theranova Dialyzer by CMS CMS evaluated the claims and assertions made by Baxter with regard to the articles submitted by them for the Theranova Dialyzer. Patients with ESRD requiring dialysis are at high risk of mortality due to the presence of uremic toxins.\\77\\ However, identifying the putative uremic toxin (or toxins) has proven challenging; the European Uremic Toxin Work Group previously identified at least 90 compounds that are retained in patients undergoing dialysis.\\78\\ Current HD technology relies on diffusion of toxins across a semi-permeable membrane to allow for the removal of small-sized (500 Da).79 80 81 The accumulation of uremic toxins with higher molecular weight is associated with immunodeficiency, inflammation, protein-wasting, and cardiovascular complications.","paper_id":8163,"paper_title":"MCO Membranes: Enhanced Selectivity in High-Flux Class","paper_year":2015,"paper_doi":"10.1038/srep18448"},{"citation_id":27759,"raw_reference":"Vanholder R, et al., European Uremic Toxin Work Group (EUTox). Review on uremic toxins: Classification, concentration, and interindividual variability. Kidney Int, 2003;63(5):1934-43.","cited_authors":"Vanholder R, et al.","cited_year":"2003","cited_title":"Review on uremic toxins: Classification, concentration, and interindividual variability","cited_venue":"Kidney Int","cited_doi":"10.1046/j.1523-1755.2003.00924.x","cited_url":null,"ref_kind":"journal_article","section":"fn 78","page":null,"context_sentence":"(2) CMS Analysis (a) Summary of Submitted Evidence of the Theranova Dialyzer by CMS CMS evaluated the claims and assertions made by Baxter with regard to the articles submitted by them for the Theranova Dialyzer. Patients with ESRD requiring dialysis are at high risk of mortality due to the presence of uremic toxins.\\77\\ However, identifying the putative uremic toxin (or toxins) has proven challenging; the European Uremic Toxin Work Group previously identified at least 90 compounds that are retained in patients undergoing dialysis.\\78\\ Current HD technology relies on diffusion of toxins across a semi-permeable membrane to allow for the removal of small-sized (500 Da).79 80 81 The accumulation of uremic toxins with higher molecular weight is associated with immunodeficiency, inflammation, protein-wasting, and cardiovascular complications.","paper_id":8165,"paper_title":"Review on uremic toxins: Classification, concentration, and interindividual variability","paper_year":2003,"paper_doi":"10.1046/j.1523-1755.2003.00924.x"},{"citation_id":27760,"raw_reference":"Macías N., et al., \"Middle molecule elimination in expanded haemodialysis: only convective transport\" Clin Kidney J., 2018;12(3):447-455.","cited_authors":"Macías N., et al.","cited_year":"2018","cited_title":"Middle molecule elimination in expanded haemodialysis: only convective transport","cited_venue":"Clin Kidney J","cited_doi":"10.1093/ckj/sfy097","cited_url":null,"ref_kind":"journal_article","section":"fn 79","page":null,"context_sentence":null,"paper_id":8164,"paper_title":"Middle molecule elimination in expanded haemodialysis: only convective transport?","paper_year":2018,"paper_doi":"10.1093/ckj/sfy097"},{"citation_id":27761,"raw_reference":"García-Prieto, A., et al., \"Evaluation of the efficacy of a medium cut-off dialyser and comparison with other high-flux dialysers in conventional haemodialysis and online haemodiafiltration.\" Clin Kidney J., 2018;11(5):742-746.","cited_authors":"García-Prieto, A., et al.","cited_year":"2018","cited_title":"Evaluation of the efficacy of a medium cut-off dialyser and comparison with other high-flux dialysers in conventional haemodialysis and online haemodiafiltration","cited_venue":"Clin Kidney J","cited_doi":"10.1093/ckj/sfy004","cited_url":null,"ref_kind":"journal_article","section":"fn 80","page":null,"context_sentence":null,"paper_id":8166,"paper_title":"Evaluation of the efficacy of a medium cut-off dialyser and comparison with other high-flux dialysers in conventional haemodialysis and online haemodiafiltration","paper_year":2018,"paper_doi":"10.1093/ckj/sfy004"},{"citation_id":27762,"raw_reference":"Dobre, M., et al., \"Searching for Uremic Toxins\" Clinical Journal of American Society of Nephrology, 2013;8(2):322-327.","cited_authors":"Dobre, M., et al.","cited_year":"2013","cited_title":"Searching for Uremic Toxins","cited_venue":"Clinical Journal of the American Society of Nephrology","cited_doi":"10.2215/cjn.04260412","cited_url":null,"ref_kind":"journal_article","section":"fn 81","page":null,"context_sentence":null,"paper_id":57541,"paper_title":"Searching for Uremic Toxins","paper_year":2012,"paper_doi":"10.2215/cjn.04260412"},{"citation_id":27763,"raw_reference":"Belmouaz, M., et al., \"Comparison of hemodialysis with medium cut-off dialyzer and on-line hemodiafiltration on the removal of small and middle-sized molecules,\" Clin Nephrol, 2018;89(1):50-56.","cited_authors":"Belmouaz, M., et al.","cited_year":"2018","cited_title":"Comparison of hemodialysis with medium cut-off dialyzer and on-line hemodiafiltration on the removal of small and middle-sized molecules","cited_venue":"Clin Nephrol","cited_doi":"10.5414/cn109133","cited_url":null,"ref_kind":"journal_article","section":"fn 83","page":null,"context_sentence":null,"paper_id":8167,"paper_title":"Comparison of hemodialysis with medium cut-off dialyzer and on-line hemodiafiltration on the removal of small and middle-sized molecules","paper_year":2017,"paper_doi":"10.5414/cn109133"},{"citation_id":27764,"raw_reference":"Cordeiro, I., et al., \"High-Flux versus High-Retention-Onset Membranes: In vivo Small and Middle Molecules Kinetics in Convective Dialysis Modalities,\" Blood Purification, 2019:1-8.","cited_authors":"Cordeiro, I., et al.","cited_year":"2019","cited_title":"High-Flux versus High-Retention-Onset Membranes: In vivo Small and Middle Molecules Kinetics in Convective Dialysis Modalities","cited_venue":"Blood Purification","cited_doi":"10.1159/000502082","cited_url":null,"ref_kind":"journal_article","section":"fn 84","page":null,"context_sentence":"For instance, solutes such as Beta-2 microglobulin (11.8 kDa) 82 83 are associated with increased mortality.\\84\\ Protein-bound solutes such as indoxyl sulfate and p-cresol sulfate also appear to be poorly dialyzable and are associated with the uremic syndrome and cardiovascular disease.\\85\\ --------------------------------------------------------------------------- ---------------------------------------------------------------------------","paper_id":8168,"paper_title":"High-Flux versus High-Retention-Onset Membranes: In vivo Small and Middle Molecules Kinetics in Convective Dialysis Modalities","paper_year":2019,"paper_doi":"10.1159/000502082"},{"citation_id":27765,"raw_reference":"Vanholder, R., et al., \"Protein-bound uremic solutes: The forgotten toxin,\" Kidney International, 2001.","cited_authors":"Vanholder, R., et al.","cited_year":"2001","cited_title":"Protein-bound uremic solutes: The forgotten toxin","cited_venue":"Kidney International","cited_doi":"10.1046/j.1523-1755.2001.59780266.x","cited_url":null,"ref_kind":"journal_article","section":"fn 85","page":null,"context_sentence":"For instance, solutes such as Beta-2 microglobulin (11.8 kDa) 82 83 are associated with increased mortality.\\84\\ Protein-bound solutes such as indoxyl sulfate and p-cresol sulfate also appear to be poorly dialyzable and are associated with the uremic syndrome and cardiovascular disease.\\85\\ --------------------------------------------------------------------------- ---------------------------------------------------------------------------","paper_id":8169,"paper_title":"Protein-bound uremic solutes: The forgotten toxins","paper_year":2001,"paper_doi":"10.1046/j.1523-1755.2001.07805.x"},{"citation_id":27766,"raw_reference":"Tanaka H, Sirich TL, Plummer NS, Weaver DS, Meyer TW. An Enlarged Profile of Uremic Solutes. PLoS One. 2015;10(8):e0135657.","cited_authors":"Tanaka H, Sirich TL, Plummer NS, Weaver DS, Meyer TW","cited_year":"2015","cited_title":"An Enlarged Profile of Uremic Solutes","cited_venue":"PLoS One","cited_doi":"10.1371/journal.pone.0135657","cited_url":null,"ref_kind":"journal_article","section":"fn 86","page":null,"context_sentence":null,"paper_id":8171,"paper_title":"An Enlarged Profile of Uremic Solutes","paper_year":2015,"paper_doi":"10.1371/journal.pone.0135657"},{"citation_id":27767,"raw_reference":"Sirich, T.L, et al., \"Limited reduction in uremic solute concentrations with increased dialysis frequency and time in the Frequent Hemodialysis Network Daily Trial.\" Kidney Int, May 2017, 91(5):1186-1192.","cited_authors":"Sirich, T.L, et al.","cited_year":"2017","cited_title":"Limited reduction in uremic solute concentrations with increased dialysis frequency and time in the Frequent Hemodialysis Network Daily Trial","cited_venue":"Kidney Int","cited_doi":"10.1016/j.kint.2016.11.002","cited_url":null,"ref_kind":"journal_article","section":"fn 87","page":null,"context_sentence":null,"paper_id":8170,"paper_title":"Limited reduction in uremic solute concentrations with increased dialysis frequency and time in the Frequent Hemodialysis Network Daily Trial","paper_year":2017,"paper_doi":"10.1016/j.kint.2016.11.002"},{"citation_id":27768,"raw_reference":"Clark, W.R., et al. \"Uremic Toxins and their Relation to Dialysis Efficacy.\" Blood Purif., 2019;48(4):299-314.","cited_authors":"Clark, W.R., et al.","cited_year":"2019","cited_title":"Uremic Toxins and their Relation to Dialysis Efficacy","cited_venue":"Blood Purif","cited_doi":"10.1159/000502331","cited_url":null,"ref_kind":"journal_article","section":"fn 88","page":null,"context_sentence":"Accumulation of middle molecule and protein-bound toxins may contribute to adverse outcomes among patients receiving dialysis \\88\\ and may explain why even a small amount of ``residual'' kidney function is strongly associated with increased survival 89 90 and higher quality of life.91 92 ---------------------------------------------------------------------------","paper_id":8172,"paper_title":"Uremic Toxins and their Relation to Dialysis Efficacy","paper_year":2019,"paper_doi":"10.1159/000502331"},{"citation_id":27769,"raw_reference":"Obi, Y., et al., \"Residual Kidney Function Decline and Mortality in Incident Hemodialysis Patients,\" J Am Soc Nephrol., 2016;27(12):3758-3768.","cited_authors":"Obi, Y., et al.","cited_year":"2016","cited_title":"Residual Kidney Function Decline and Mortality in Incident Hemodialysis Patients","cited_venue":"J Am Soc Nephrol","cited_doi":"10.1681/asn.2015101142","cited_url":null,"ref_kind":"journal_article","section":"fn 89","page":null,"context_sentence":null,"paper_id":8173,"paper_title":"Residual Kidney Function Decline and Mortality in Incident Hemodialysis Patients","paper_year":2016,"paper_doi":"10.1681/asn.2015101142"},{"citation_id":27770,"raw_reference":"Wang, A.Y. and Lai, K.N. \"The importance of residual renal function in dialysis patients.\" Kidney Int., 2006;69(10):1726-32.","cited_authors":"Wang, A.Y. and Lai, K.N.","cited_year":"2006","cited_title":"The importance of residual renal function in dialysis patients","cited_venue":"Kidney Int","cited_doi":"10.1038/sj.ki.5000382","cited_url":null,"ref_kind":"journal_article","section":"fn 90","page":null,"context_sentence":null,"paper_id":8175,"paper_title":"The importance of residual renal function in dialysis patients","paper_year":2006,"paper_doi":"10.1038/sj.ki.5000382"},{"citation_id":27771,"raw_reference":"Bargman, J.M., et al., \"Relative contribution of residual renal function and peritoneal clearance to adequacy of dialysis: A reanalysis of the CANUSA Study,\" J Am Soc Nephrol., 2001;12(10):2158-62.","cited_authors":"Bargman, J.M., et al.","cited_year":"2001","cited_title":"Relative contribution of residual renal function and peritoneal clearance to adequacy of dialysis: A reanalysis of the CANUSA Study","cited_venue":"J Am Soc Nephrol","cited_doi":"10.1681/asn.v12102158","cited_url":null,"ref_kind":"journal_article","section":"fn 92","page":null,"context_sentence":null,"paper_id":8174,"paper_title":"Relative Contribution of Residual Renal Function and Peritoneal Clearance to Adequacy of Dialysis: A Reanalysis of the CANUSA Study","paper_year":2001,"paper_doi":"10.1681/asn.v12102158"},{"citation_id":27772,"raw_reference":"Zweigart, C., et al., \"Medium cut-off membranes—closer to the natural kidney removal function,\" Int J Artif Organs, 2017;40(7):328-334. DOI: 10.5301/uijao.5000603.","cited_authors":"Zweigart, C., et al.","cited_year":"2017","cited_title":"Medium cut-off membranes—closer to the natural kidney removal function","cited_venue":"Int J Artif Organs","cited_doi":"10.5301/uijao.5000603","cited_url":null,"ref_kind":"journal_article","section":"fn 93","page":null,"context_sentence":"Substantial fluid losses with convection, must be replaced via infusion of typically ultrapure water and dialysis fluids.\\93\\ This newer technology was later supplemented by online HDF, which enables dialysis providers with ultrapure water systems to generate replacement fluid solution.","paper_id":8181,"paper_title":"Medium Cut-Off Membranes - Closer to the Natural Kidney Removal Function","paper_year":2017,"paper_doi":"10.5301/ijao.5000603"},{"citation_id":27773,"raw_reference":"Grooteman, M.P., et al.; CONTRAST Investigators. Effect of online hemodiafiltration on all-cause mortality and cardiovascular outcomes, J Am Soc Nephrol., 2012;23(6):1087-1096.","cited_authors":"Grooteman, M.P., et al.","cited_year":"2012","cited_title":"Effect of online hemodiafiltration on all-cause mortality and cardiovascular outcomes","cited_venue":"J Am Soc Nephrol","cited_doi":"10.1681/asn.2011121140","cited_url":null,"ref_kind":"journal_article","section":"fn 95","page":null,"context_sentence":null,"paper_id":8177,"paper_title":"Effect of Online Hemodiafiltration on All-Cause Mortality and Cardiovascular Outcomes","paper_year":2012,"paper_doi":"10.1681/asn.2011121140"},{"citation_id":27774,"raw_reference":"Maduell, F., et al., ESHOL Study Group. High-efficiency postdilution online hemodiafiltration reduces all-cause mortality in hemodialysis patients, J Am Soc Nephrol., 2013;24(3):487-497.","cited_authors":"Maduell, F., et al.","cited_year":"2013","cited_title":"High-efficiency postdilution online hemodiafiltration reduces all-cause mortality in hemodialysis patients","cited_venue":"J Am Soc Nephrol","cited_doi":"10.1681/asn.2012080875","cited_url":null,"ref_kind":"journal_article","section":"fn 96","page":null,"context_sentence":null,"paper_id":8176,"paper_title":"High-Efficiency Postdilution Online Hemodiafiltration Reduces All-Cause Mortality in Hemodialysis Patients","paper_year":2013,"paper_doi":"10.1681/asn.2012080875"},{"citation_id":27775,"raw_reference":"Morena, M., et al., FRENCHIE Study Investigators. Treatment tolerance and patient-reported outcomes favor online hemodiafiltration compared to high-flux hemodialysis in the elderly, Kidney Int., 2017;91(6):1495-1509.","cited_authors":"Morena, M., et al.","cited_year":"2017","cited_title":"Treatment tolerance and patient-reported outcomes favor online hemodiafiltration compared to high-flux hemodialysis in the elderly","cited_venue":"Kidney Int","cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"fn 97","page":null,"context_sentence":null,"paper_id":70416,"paper_title":"Treatment tolerance and patient-reported outcomes favor online hemodiafiltration compared to high-flux hemodialysis in the elderly","paper_year":2017,"paper_doi":"10.1016/j.kint.2017.01.013"},{"citation_id":27776,"raw_reference":"Ok, E., et al., Online Haemodiafiltration Study. Mortality and cardiovascular events in online haemodiafiltration (OL-HDF) compared with high-flux dialysis: Results from the Turkish OL-HDF Study, Nephrol Dial Transplant, 2013;28(1):192-202.","cited_authors":"Ok, E., et al.","cited_year":"2013","cited_title":"Mortality and cardiovascular events in online haemodiafiltration (OL-HDF) compared with high-flux dialysis: Results from the Turkish OL-HDF Study","cited_venue":"Nephrol Dial Transplant","cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"fn 98","page":null,"context_sentence":null,"paper_id":70335,"paper_title":"Mortality and cardiovascular events in online haemodiafiltration (OL-HDF) compared with high-flux dialysis: results from the Turkish OL-HDF Study","paper_year":2012,"paper_doi":"10.1093/ndt/gfs407"},{"citation_id":27777,"raw_reference":"Krause, B., et al., \"Highly selective membranes for Blood purification,\" Gambro Dialysatoren GmbH, Presentation abstract March 26, 2015.","cited_authors":"Krause, B., et al.","cited_year":"2015","cited_title":"Highly selective membranes for Blood purification","cited_venue":"Gambro Dialysatoren GmbH","cited_doi":null,"cited_url":null,"ref_kind":"other","section":"fn 101","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":27778,"raw_reference":"Amyot, S.L, et al., \"Myoglobin clearance and removal during continuous venovenous hemofiltration,\" Intensive Care Medicine, 1999(25):1169-1172.","cited_authors":"Amyot, S.L, et al.","cited_year":"1999","cited_title":"Myoglobin clearance and removal during continuous venovenous hemofiltration","cited_venue":"Intensive Care Medicine","cited_doi":"10.1007/s001340051031","cited_url":null,"ref_kind":"journal_article","section":"fn 103","page":null,"context_sentence":"In rhabdomyolysis, myoglobin clearance has been demonstrated with large pore dialyzers and HDF, but clinical benefit remains largely unproven.\\103\\ Similarly, HDF has historically garnered much attention in sepsis due to its ability to efficiently clear inflammatory cytokines like IL-6, but numerous studies have shown no mortality benefit in sepsis with possible downsides in the form of shortened filter life.\\104\\ No trials have examined the potential benefit of removing larger quantities of middle molecules than is typically achieved from high-flux membranes. --------------------------------------------------------------------------- ---------------------------------------------------------------------------","paper_id":8178,"paper_title":"Myoglobin clearance and removal during continuous venovenous hemofiltration","paper_year":1999,"paper_doi":"10.1007/s001340051031"},{"citation_id":27779,"raw_reference":"Friedrich J.O., et al., \"Hemofiltration compared to hemodialysis for acute kidney injury: Systematic review and meta-analysis,\" Critical Care, 2012;16:R146.","cited_authors":"Friedrich J.O., et al.","cited_year":"2012","cited_title":"Hemofiltration compared to hemodialysis for acute kidney injury: Systematic review and meta-analysis","cited_venue":"Critical Care","cited_doi":"10.1186/cc11458","cited_url":null,"ref_kind":"journal_article","section":"fn 104","page":null,"context_sentence":"In rhabdomyolysis, myoglobin clearance has been demonstrated with large pore dialyzers and HDF, but clinical benefit remains largely unproven.\\103\\ Similarly, HDF has historically garnered much attention in sepsis due to its ability to efficiently clear inflammatory cytokines like IL-6, but numerous studies have shown no mortality benefit in sepsis with possible downsides in the form of shortened filter life.\\104\\ No trials have examined the potential benefit of removing larger quantities of middle molecules than is typically achieved from high-flux membranes. --------------------------------------------------------------------------- ---------------------------------------------------------------------------","paper_id":8179,"paper_title":"Hemofiltration compared to hemodialysis for acute kidney injury: systematic review and meta-analysis","paper_year":2012,"paper_doi":"10.1186/cc11458"},{"citation_id":27780,"raw_reference":"Kalim, S., et al., \"Extended Duration Nocturnal Hemodialysis and Changes in Plasma Metabolite Profiles,\" Clin J Am Soc Nephrol, 2018;13(3):436-444.","cited_authors":"Kalim, S., et al.","cited_year":"2018","cited_title":"Extended Duration Nocturnal Hemodialysis and Changes in Plasma Metabolite Profiles","cited_venue":"Clin J Am Soc Nephrol","cited_doi":"10.2215/cjn.08790817","cited_url":null,"ref_kind":"journal_article","section":"fn 107","page":null,"context_sentence":null,"paper_id":6417,"paper_title":"Extended Duration Nocturnal Hemodialysis and Changes in Plasma Metabolite Profiles","paper_year":2018,"paper_doi":"10.2215/cjn.08790817"},{"citation_id":27781,"raw_reference":"Caramelo C, Just S, Gil P. Anemia in Heart Failure: Pathophysiology, Pathogenesis, Treatment and Incognitae. Rev Esp Cardiol. 2007;60(8):848-860.","cited_authors":"Caramelo C, Just S, Gil P","cited_year":"2007","cited_title":"Anemia in Heart Failure: Pathophysiology, Pathogenesis, Treatment and Incognitae","cited_venue":"Rev Esp Cardiol","cited_doi":"10.1016/s1885-5857(08)60029-8","cited_url":null,"ref_kind":"journal_article","section":"Published in Peer-Reviewed Journals / Review Articles and Editorials","page":null,"context_sentence":null,"paper_id":8180,"paper_title":"Anemia in Heart Failure: Pathophysiology, Pathogenesis, Treatment, and Incognitae","paper_year":2007,"paper_doi":"10.1016/s1885-5857(08)60029-8"},{"citation_id":27782,"raw_reference":"Florens N, Juillard L. \"Expanded Haemodialysis: News from the Field,\" Nephrol Dial Transplant, 2018;33:iii48-iii52.","cited_authors":"Florens N, Juillard L.","cited_year":"2018","cited_title":"Expanded Haemodialysis: News from the Field","cited_venue":"Nephrol Dial Transplant","cited_doi":"10.1093/ndt/gfy203","cited_url":null,"ref_kind":"journal_article","section":"Review Articles/Editorials","page":null,"context_sentence":null,"paper_id":8182,"paper_title":"Expanded haemodialysis: news from the field","paper_year":2018,"paper_doi":"10.1093/ndt/gfy203"},{"citation_id":27783,"raw_reference":"Wolley M, Jardin M, Hutchinson, C. \"Exploring the Clinical Relevance of Providing Increased Removal of Large Middle Molecules,\" J Am Soc Nephrol 2018;13:805-813.","cited_authors":"Wolley M, Jardin M, Hutchinson C","cited_year":"2018","cited_title":"Exploring the Clinical Relevance of Providing Increased Removal of Large Middle Molecules","cited_venue":"J Am Soc Nephrol","cited_doi":"10.2215/cjn.10110917","cited_url":null,"ref_kind":"journal_article","section":"Review Articles/Editorials","page":null,"context_sentence":null,"paper_id":8183,"paper_title":"Exploring the Clinical Relevance of Providing Increased Removal of Large Middle Molecules","paper_year":2018,"paper_doi":"10.2215/cjn.10110917"},{"citation_id":27784,"raw_reference":"Kharbanda K, et al., A Randomised Study Investigating the Effect of Medium Cut-Off Haemodialysis on Markers of Vascular Health Compared with On-Line Haemodiafiltration (MoDal Study). Manchester Metropolitan University. 2019","cited_authors":"Kharbanda K, Herring A, Wilkinson F, Alexander Y, Mitra S","cited_year":"2019","cited_title":"A Randomised Study Investigating the Effect of Medium Cut-Off Haemodialysis on Markers of Vascular Health Compared with On-Line Haemodiafiltration (MoDal Study)","cited_venue":"Manchester Metropolitan University","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"Posters and Abstracts","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":27785,"raw_reference":"Kirsch AH, Lyko R, Nilsson LG., et al. Performance of hemodialysis with novel medium cut-off dialyzers. Nephrol Dial Transplant 2017;32:165-172.","cited_authors":"Kirsch AH, Lyko R, Nilsson LG, et al.","cited_year":"2017","cited_title":"Performance of hemodialysis with novel medium cut-off dialyzers","cited_venue":"Nephrol Dial Transplant","cited_doi":"10.1093/ndt/gfw310","cited_url":null,"ref_kind":"journal_article","section":"Posters and Abstracts","page":null,"context_sentence":null,"paper_id":7536,"paper_title":"Performance of hemodialysis with novel medium cut-off dialyzers","paper_year":2016,"paper_doi":"10.1093/ndt/gfw310"},{"citation_id":27786,"raw_reference":"Weiner DE, et al., Efficacy and Safety of Expanded Hemodialysis Enabled by a Medium Cut-Off Membrane: A Randomized Control Trial. FR-PO 488, ASN 2019.","cited_authors":"Weiner DE, Falzon L, Beck W, Xiao M, Tran H, Bernardo AA","cited_year":"2019","cited_title":"Efficacy and Safety of Expanded Hemodialysis Enabled by a Medium Cut-Off Membrane: A Randomized Control Trial","cited_venue":"ASN Kidney Week","cited_doi":null,"cited_url":null,"ref_kind":"conference_paper","section":"Posters and Abstracts","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":27787,"raw_reference":"Alarcon J, et al., Real world evidence on the impact of expanded hemodialysis (HDx) therapy on Patient Reported Outcomes (PROs): CPREXH Registry (in submission).","cited_authors":"Alarcon J, Bunch A, Ardila F, Zuniga E, Vesga J, Rivera A, Sanchez R, Sanabria M","cited_year":null,"cited_title":"Real world evidence on the impact of expanded hemodialysis (HDx) therapy on Patient Reported Outcomes (PROs): CPREXH Registry","cited_venue":"In submission","cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"Posters and Abstracts","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":27788,"raw_reference":"Sanabria RM, et al., Expanded Hemodialysis and its effects on hospitalization and medication usage: An exploratory study. (in submission).","cited_authors":"Sanabria RM, Vesga JI, Ariza J, Sanchez R, Suarez A, Bernardo A, Rivera A","cited_year":null,"cited_title":"Expanded Hemodialysis and its effects on hospitalization and medication usage: An exploratory study","cited_venue":"In submission","cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"Posters and Abstracts","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":27789,"raw_reference":"Plumb TJ, et al., Safety and efficacy of the Tablo hemodialysis system for in-center and home hemodialysis. Hemodial Int. 2020;24(1):22-28. doi:10.1111/hdi.12795.","cited_authors":"Plumb TJ, Alvarez L, Ross DL, Lee JJ, Mulhern JG, Bell JL, Abra G, Prichard SS, Chertow GM, Aragon MA","cited_year":"2020","cited_title":"Safety and efficacy of the Tablo hemodialysis system for in-center and home hemodialysis","cited_venue":"Hemodialysis International","cited_doi":"10.1111/hdi.12795","cited_url":null,"ref_kind":"journal_article","section":"fn 202 (Tablo section)","page":null,"context_sentence":null,"paper_id":6616,"paper_title":"Safety and efficacy of the Tablo hemodialysis system for in‐center and home hemodialysis","paper_year":2019,"paper_doi":"10.1111/hdi.12795"},{"citation_id":27790,"raw_reference":"Kraus M, et al., A comparison of center-based vs. home-based daily hemodialysis for patients with end-stage renal disease. Hemodialysis International, 11:468-477, 2007.","cited_authors":"Kraus M, Burkart J, Hegeman R, Solomon R, Coplon N, Moran J","cited_year":"2007","cited_title":"A comparison of center-based vs. home-based daily hemodialysis for patients with end-stage renal disease","cited_venue":"Hemodialysis International","cited_doi":"10.1111/j.1542-4758.2007.00229.x","cited_url":null,"ref_kind":"journal_article","section":"fn 203","page":null,"context_sentence":"Kraus M, et al.\\203\\ is a study involving the comparator technology known as NxStage[supreg] System, which is a portable HD unit.","paper_id":6617,"paper_title":"A comparison of center‐based vs. home‐based daily hemodialysis for patients with end‐stage renal disease","paper_year":2007,"paper_doi":"10.1111/j.1542-4758.2007.00229.x"},{"citation_id":27791,"raw_reference":"Wilcox, Stephen B., et al. Results of Human Factors Testing in a Novel Hemodialysis System Designed for Ease of Patient Use. Hemodialysis International, vol. 20, no. 4, 2016, pp. 643-649.","cited_authors":"Wilcox, Stephen B., et al.","cited_year":"2016","cited_title":"Results of Human Factors Testing in a Novel Hemodialysis System Designed for Ease of Patient Use","cited_venue":"Hemodialysis International","cited_doi":"10.1111/hdi.12430","cited_url":null,"ref_kind":"journal_article","section":"fn 147","page":null,"context_sentence":null,"paper_id":8184,"paper_title":"Results of human factors testing in a novel Hemodialysis system designed for ease of patient use","paper_year":2016,"paper_doi":"10.1111/hdi.12430"},{"citation_id":27792,"raw_reference":"Sehasi, Rebecca et al. Factors Associated With Discontinuation of Home Hemodialysis, American Journal of Kidney Disease, 2016;67(4):629-637.","cited_authors":"Seshasai RK, Mitra N, Chaknos CM, Li J, Wirtalla C, Negoianu D, Glickman JD, Dember LM","cited_year":"2016","cited_title":"Factors Associated With Discontinuation of Home Hemodialysis","cited_venue":"American Journal of Kidney Diseases","cited_doi":"10.1053/j.ajkd.2015.11.003","cited_url":null,"ref_kind":"journal_article","section":"fn 154","page":null,"context_sentence":"Contributing to this low penetration rate is also a high dropout rate with the incumbent home devices of 25 percent and 35 percent at 12 and 24 months, respectively.\\154\\ The barriers to home dialysis adoption and retention have been well studied and include: (1) Treatment burden for patients and care partner fatigue; (2) technical challenges operating HD machine; (3) space, home modifications, and supplies management; (4) patients not wanting medical equipment in the home; and (5) safety concerns.155 156 The applicant asserted that Tablo[supreg] is the first new home HD system in over 15 years, designed to address many of the above-mentioned barriers that currently result in patients resigning themselves to in-center care and/or stopping home modalities due to the associated burden of self-managed therapy.","paper_id":7871,"paper_title":"Factors Associated With Discontinuation of Home Hemodialysis","paper_year":2015,"paper_doi":"10.1053/j.ajkd.2015.11.003"},{"citation_id":27793,"raw_reference":"Seshasai, R.K., et al. The home hemodialysis patient experience: A qualitative assessment of modality use and discontinuation. Hemodialysis International, 23:139-150, 2019.","cited_authors":"Seshasai, R.K., et al.","cited_year":"2019","cited_title":"The home hemodialysis patient experience: A qualitative assessment of modality use and discontinuation","cited_venue":"Hemodialysis International","cited_doi":"10.1111/hdi.12713","cited_url":null,"ref_kind":"journal_article","section":"fn 155","page":null,"context_sentence":null,"paper_id":6609,"paper_title":"The home hemodialysis patient experience: A qualitative assessment of modality use and discontinuation","paper_year":2019,"paper_doi":"10.1111/hdi.12713"},{"citation_id":27794,"raw_reference":"Chan, Christopher T. et al. Exploring Barriers and Potential Solutions in Home Dialysis: An NKF-KDOQI Conference Outcomes Report, American Journal of Kidney Diseases, 2019;73(3):363-371.","cited_authors":"Chan, Christopher T., et al.","cited_year":"2019","cited_title":"Exploring Barriers and Potential Solutions in Home Dialysis: An NKF-KDOQI Conference Outcomes Report","cited_venue":"American Journal of Kidney Diseases","cited_doi":"10.1053/j.ajkd.2018.09.015","cited_url":null,"ref_kind":"journal_article","section":"fn 156","page":null,"context_sentence":null,"paper_id":6610,"paper_title":"Exploring Barriers and Potential Solutions in Home Dialysis: An NKF-KDOQI Conference Outcomes Report","paper_year":2018,"paper_doi":"10.1053/j.ajkd.2018.09.015"},{"citation_id":27795,"raw_reference":"U.S. Department of Health and Human Services, Office of the Assistant Secretary for Planning and Evaluation, Advancing American Kidney Health, July 10, 2019.","cited_authors":"U.S. Department of Health and Human Services, Office of the Assistant Secretary for Planning and Evaluation","cited_year":"2019","cited_title":"Advancing American Kidney Health","cited_venue":"HHS ASPE","cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"fn 157","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":27796,"raw_reference":"United States Renal Data System. 2019 USRDS annual data report: Epidemiology of kidney disease in the United States. NIH, NIDDK, Bethesda, MD, 2019.","cited_authors":"United States Renal Data System","cited_year":"2019","cited_title":"2019 USRDS annual data report: Epidemiology of kidney disease in the United States","cited_venue":"National Institutes of Health, NIDDK","cited_doi":null,"cited_url":null,"ref_kind":"dataset","section":"fn 169","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":27797,"raw_reference":"Wilk, Adam S. et al., Persistent Variation in Medicare Payment Authorization for Home Hemodialysis Treatments, Health services research vol. 53,2 (2018): 649-670.","cited_authors":"Wilk, Adam S., et al.","cited_year":"2018","cited_title":"Persistent Variation in Medicare Payment Authorization for Home Hemodialysis Treatments","cited_venue":"Health Services Research","cited_doi":"10.1111/1475-6773.12650","cited_url":null,"ref_kind":"journal_article","section":"fn 170","page":null,"context_sentence":"The applicant said that among home HD patients, Medicare payment for dialysis treatments was highly variable across different regions at 3.5 to 5.7 per week.\\170\\ In the IDE for the Tablo[supreg] Hemodialysis System, the applicant asserted that there was effectively delivered adequacy with 4 treatments per week with an average session length of 3.4 hours, resulting in an average weekly treatment duration of ~13.6 hours.","paper_id":6623,"paper_title":"Persistent Variation in Medicare Payment Authorization for Home Hemodialysis Treatments","paper_year":2017,"paper_doi":"10.1111/1475-6773.12650"},{"citation_id":27798,"raw_reference":"Agency for Healthcare Quality and Research, End Stage Renal Disease in the Medicare Population: Frequency and Duration of Hemodialysis and Quality of Life Assessment, Draft Technology Assessment, November 22, 2019.","cited_authors":"Agency for Healthcare Quality and Research","cited_year":"2019","cited_title":"End Stage Renal Disease in the Medicare Population: Frequency and Duration of Hemodialysis and Quality of Life Assessment","cited_venue":"Agency for Healthcare Quality and Research","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"fn 174","page":null,"context_sentence":"The applicant stated that Tablo[supreg] Hemodialysis System's ability to deliver adequacy on fewer treatments per week may also reduce vascular access complications due to frequent cannulation.\\174\\ --------------------------------------------------------------------------- ---------------------------------------------------------------------------","paper_id":66446,"paper_title":"End-stage Renal Disease in the Medicare Population: Frequency and Duration of Hemodialysis and Quality of Life Assessment","paper_year":2020,"paper_doi":null},{"citation_id":27799,"raw_reference":"Urquhart-Secord, Rachel et al. Patient and Caregiver Priorities for Outcomes in Hemodialysis: An International Nominal Group Technique Study, American Journal of Kidney Diseases, Sept. 2016;68(3):444-454.","cited_authors":"Urquhart-Secord, Rachel, et al.","cited_year":"2016","cited_title":"Patient and Caregiver Priorities for Outcomes in Hemodialysis: An International Nominal Group Technique Study","cited_venue":"American Journal of Kidney Diseases","cited_doi":"10.1053/j.ajkd.2016.02.037","cited_url":null,"ref_kind":"journal_article","section":"fn 175","page":null,"context_sentence":"The applicant noted that patients value having a high- quality daily life, ability to live well, and feeling empowered to control their outcomes over mortality.\\175\\ The applicant asserted that the use of the Tablo[supreg] Hemodialysis System at home allows patients to have an improved quality of life and control over their outcomes. --------------------------------------------------------------------------- ---------------------------------------------------------------------------","paper_id":6633,"paper_title":"Patient and Caregiver Priorities for Outcomes in Hemodialysis: An International Nominal Group Technique Study","paper_year":2016,"paper_doi":"10.1053/j.ajkd.2016.02.037"},{"citation_id":27800,"raw_reference":"Kidney Health Initiative, Technology Roadmap for Innovative Approaches to Renal Replacement Therapy, prepared by the Nexight Group, October 2018.","cited_authors":"Kidney Health Initiative","cited_year":"2018","cited_title":"Technology Roadmap for Innovative Approaches to Renal Replacement Therapy","cited_venue":"Nexight Group","cited_doi":null,"cited_url":"https://www.asnonline.org/g/blast/files/KHI_RRT_Roadmap1.0_FINAL_102318_web.pdf","ref_kind":"research_report","section":"fn 181","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":27801,"raw_reference":"Young BA, Chan C, Blagg C, et al. How to overcome barriers and establish a successful home HD program. Clin J Am Soc Nephrol. 2012;7(12):2023-32.","cited_authors":"Young BA, Chan C, Blagg C, Lockridge R, Golper T, Finkelstein F, Shaffer R, Mehrotra R","cited_year":"2012","cited_title":"How to overcome barriers and establish a successful home HD program","cited_venue":"Clin J Am Soc Nephrol","cited_doi":"10.2215/cjn.07080712","cited_url":null,"ref_kind":"journal_article","section":"fn 185","page":null,"context_sentence":"In 2017, only 10.8 percent of US dialysis patients received home-based therapies.\\184\\ Patients and caregivers cite concerns with self-cannulation, fears of needle disconnect and complications.\\185\\ Home dialysis use is lower than many other rich countries.\\186\\ --------------------------------------------------------------------------- ---------------------------------------------------------------------------","paper_id":8185,"paper_title":"How to Overcome Barriers and Establish a Successful Home HD Program","paper_year":2012,"paper_doi":"10.2215/cjn.07080712"},{"citation_id":27802,"raw_reference":"Wilkie M. Home dialysis—an international perspective. NDT Plus. 2011;4(Suppl 3):iii4-iii6.","cited_authors":"Wilkie M","cited_year":"2011","cited_title":"Home dialysis—an international perspective","cited_venue":"NDT Plus","cited_doi":"10.1093/ndtplus/sfr129","cited_url":null,"ref_kind":"journal_article","section":"fn 186","page":null,"context_sentence":"In 2017, only 10.8 percent of US dialysis patients received home-based therapies.\\184\\ Patients and caregivers cite concerns with self-cannulation, fears of needle disconnect and complications.\\185\\ Home dialysis use is lower than many other rich countries.\\186\\ --------------------------------------------------------------------------- ---------------------------------------------------------------------------","paper_id":8186,"paper_title":"Home dialysis--an international perspective","paper_year":2011,"paper_doi":"10.1093/ndtplus/sfr129"},{"citation_id":27803,"raw_reference":"Berger A, Edelsberg J, Inglese GW, Bhattacharyya SK, Oster G. Cost comparison of peritoneal dialysis versus hemodialysis in end-stage renal disease. American Journal of Managed Care. 2009;15:509-518.","cited_authors":"Berger A, Edelsberg J, Inglese GW, Bhattacharyya SK, Oster G","cited_year":"2009","cited_title":"Cost comparison of peritoneal dialysis versus hemodialysis in end-stage renal disease","cited_venue":"American Journal of Managed Care","cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"fn 191","page":null,"context_sentence":"Prior analyses have noted that home-based dialysis affords greater patient flexibility, improved quality of life,\\189\\ increased likelihood of employment,\\190\\ and improved cost.\\191\\ However, regarding cost comparisons, it is important to note that many cost analyses of home- based dialysis include estimates from PD.","paper_id":70363,"paper_title":"Cost comparison of peritoneal dialysis versus hemodialysis in end-stage renal disease.","paper_year":2009,"paper_doi":null},{"citation_id":27804,"raw_reference":"Ash SR. The Allient dialysis system. Semin Dial. 2004;17(2):164-6.","cited_authors":"Ash SR","cited_year":"2004","cited_title":"The Allient dialysis system","cited_venue":"Seminars in Dialysis","cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"fn 196","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":27805,"raw_reference":"Cafazzo JA, Leonard K, Easty AC, Rossos PG, Chan CT. Patient-perceived barriers to the adoption of Nocturnal Home Hemodialysis. Clin J Am Soc Nephrol. 2009;4:784-789.","cited_authors":"Cafazzo JA, Leonard K, Easty AC, Rossos PG, Chan CT","cited_year":"2009","cited_title":"Patient-perceived barriers to the adoption of Nocturnal Home Hemodialysis","cited_venue":"Clin J Am Soc Nephrol","cited_doi":"10.2215/cjn.05501008","cited_url":null,"ref_kind":"journal_article","section":"fn 199","page":null,"context_sentence":null,"paper_id":8188,"paper_title":"Patient-Perceived Barriers to the Adoption of Nocturnal Home Hemodialysis","paper_year":2009,"paper_doi":"10.2215/cjn.05501008"},{"citation_id":27806,"raw_reference":"Suri RS, Larive B, Garg AX, et al. Burden on caregivers as perceived by hemodialysis patients in the frequent Hemodialysis network (FHN) trials. Nephrol Dial Transplant. 2011;26:2316-2322.","cited_authors":"Suri RS, Larive B, Garg AX, et al.","cited_year":"2011","cited_title":"Burden on caregivers as perceived by hemodialysis patients in the frequent Hemodialysis network (FHN) trials","cited_venue":"Nephrol Dial Transplant","cited_doi":"10.1093/ndt/gfr007","cited_url":null,"ref_kind":"journal_article","section":"fn 200","page":null,"context_sentence":null,"paper_id":8189,"paper_title":"Burden on caregivers as perceived by hemodialysis patients in the Frequent Hemodialysis Network (FHN) trials","paper_year":2011,"paper_doi":"10.1093/ndt/gfr007"},{"citation_id":27807,"raw_reference":"Zhang AH, Bargman JM, Lok CE, et al. Dialysis modality choices among chronic kidney disease patients: Identifying the gaps to support patients on home-based therapies. Int Urol Nephrol. 2010;42:759-764.","cited_authors":"Zhang AH, Bargman JM, Lok CE, et al.","cited_year":"2010","cited_title":"Dialysis modality choices among chronic kidney disease patients: Identifying the gaps to support patients on home-based therapies","cited_venue":"Int Urol Nephrol","cited_doi":"10.1007/s11255-010-9793-9","cited_url":null,"ref_kind":"journal_article","section":"fn 201","page":null,"context_sentence":null,"paper_id":8187,"paper_title":"Dialysis modality choices among chronic kidney disease patients: identifying the gaps to support patients on home-based therapies","paper_year":2010,"paper_doi":"10.1007/s11255-010-9793-9"},{"citation_id":28368,"raw_reference":"Boschetti-de-Fierro, A., et al., \"MCO Membranes: Enhanced Selectivity in High-Flux Cases,\" Scientific Reports, [5:18448] DOI: 10.1038/srep18448.","cited_authors":"Boschetti-de-Fierro, A., et al.","cited_year":null,"cited_title":"MCO Membranes: Enhanced Selectivity in High-Flux Cases","cited_venue":"Scientific Reports","cited_doi":"10.1038/srep18448","cited_url":null,"ref_kind":"journal_article","section":"fn 25","page":null,"context_sentence":null,"paper_id":8163,"paper_title":"MCO Membranes: Enhanced Selectivity in High-Flux Class","paper_year":2015,"paper_doi":"10.1038/srep18448"},{"citation_id":28369,"raw_reference":"Krause, B., et al., \"Highly selective membranes for Blood purification,\" Gambro Dialysatoren GmbH, Hechingen/Germany, Presentation abstract March 26, 2015.","cited_authors":"Krause, B., et al.","cited_year":"2015","cited_title":"Highly selective membranes for Blood purification","cited_venue":"Gambro Dialysatoren GmbH","cited_doi":null,"cited_url":null,"ref_kind":"other","section":"fn 26","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":28370,"raw_reference":"Zweigart, C., et al., \"Medium cut-off membranes—closer to the natural kidney removal function,\" Int. J Artif Organs, 2017, 40(7), pp. 328-334. DOI: 10.5301/uijao.5000603.","cited_authors":"Zweigart, C., et al.","cited_year":"2017","cited_title":"Medium cut-off membranes—closer to the natural kidney removal function","cited_venue":"Int. J Artif Organs","cited_doi":"10.5301/uijao.5000603","cited_url":null,"ref_kind":"journal_article","section":"fn 27","page":null,"context_sentence":null,"paper_id":8181,"paper_title":"Medium Cut-Off Membranes - Closer to the Natural Kidney Removal Function","paper_year":2017,"paper_doi":"10.5301/ijao.5000603"},{"citation_id":28371,"raw_reference":"Lorenzin, A., et al., \"Quantification of Internal Filtration in Hollow Fiber Hemodialyzers with Medium Cut-Off Membrane,\" Blood Purif, 2018, 46, pp. 196-204.","cited_authors":"Lorenzin, A., et al.","cited_year":"2018","cited_title":"Quantification of Internal Filtration in Hollow Fiber Hemodialyzers with Medium Cut-Off Membrane","cited_venue":"Blood Purif","cited_doi":"10.1159/000489993","cited_url":null,"ref_kind":"journal_article","section":"fn 28","page":null,"context_sentence":"additional convective transport.\\28\\ The Theranova dialyzer enables the efficient removal of uremic toxins (up to 45 kDa).29 30 The applicant included an adapted figure from a book titled, ``Modelling and Control of Dialysis Systems \\31\\ to compare removal of toxins by Theranova to the kidney and to other dialysis therapies, such as low flux dialyzers (LF), high flux dialyzers (HFD) and hemodiafiltration (HDF).","paper_id":8248,"paper_title":"Quantification of Internal Filtration in Hollow Fiber Hemodialyzers with Medium Cut-Off Membrane","paper_year":2018,"paper_doi":"10.1159/000489993"},{"citation_id":28372,"raw_reference":"Azar, A.T. and Canaud, B., \"Chapter 8: Hemodialysis System,\" Modeling and Control of Dialysis Systems, 2013, pp. 99-106, Springer-Verlag, Berlin, Heidelberg.","cited_authors":"Azar, A.T.; Canaud, B.","cited_year":"2013","cited_title":"Chapter 8: Hemodialysis System","cited_venue":"Modeling and Control of Dialysis Systems, Springer-Verlag","cited_doi":null,"cited_url":null,"ref_kind":"book_chapter","section":"fn 31","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":28373,"raw_reference":"United States Renal Data System. 2018 USRDS annual data report: Epidemiology of kidney disease in the United States. National Institutes of Health, NIDDK, Bethesda, MD, 2018.","cited_authors":"United States Renal Data System","cited_year":"2018","cited_title":"2018 USRDS annual data report: Epidemiology of kidney disease in the United States","cited_venue":"National Institutes of Health, National Institute of Diabetes and Digestive and Kidney Diseases","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"fn 35","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":28374,"raw_reference":"Cozzolino, C., et al., \"Effects of a medium cut-off (Theranova) dialyzer on haemodialaysis patients: A prospective, cross-over study,\" Clinical Kidney Journal, 2019, pp. 1-8. Doi 10.1093/ckj/sfz 155.","cited_authors":"Cozzolino, C., et al.","cited_year":"2019","cited_title":"Effects of a medium cut-off (Theranova) dialyzer on haemodialysis patients: A prospective, cross-over study","cited_venue":"Clinical Kidney Journal","cited_doi":"10.1093/ckj/sfz155","cited_url":null,"ref_kind":"journal_article","section":"fn 36","page":null,"context_sentence":"A prospective cross-over study found an average of seven episodes of infection for patients treated with HDx versus 18 for high flux HD (p = 0.003).\\36\\ The applicant also stated that patients receiving HDx therapy with Theranova had hospital stays averaging 4.4 days versus 5.9 days for patients receiving traditional HD (p = 0.0001) along with lower hospitalization rates (71 percent versus 77 percent (p = 0.69)).\\37\\ The U.S.","paper_id":8250,"paper_title":"Effects of a medium cut-off (Theranova®) dialyser on haemodialysis patients: a prospective, cross-over study","paper_year":2019,"paper_doi":"10.1093/ckj/sfz155"},{"citation_id":28375,"raw_reference":"Weiner, D.E., et al. 2019, \"Efficacy and Safety of Expanded Hemodialysis with the Theranova 400 Dialyzer: A Randomized Control Trial,\" Abstract at ASN meeting, FR-PO 488.","cited_authors":"Weiner, D.E., et al.","cited_year":"2019","cited_title":"Efficacy and Safety of Expanded Hemodialysis with the Theranova 400 Dialyzer: A Randomized Control Trial","cited_venue":"ASN meeting","cited_doi":"10.2215/cjn.01210120","cited_url":null,"ref_kind":"conference_paper","section":"fn 38","page":null,"context_sentence":"IDE Randomized Controlled Trial (NCT032574 l 0) of 172 patients, although not powered for all-cause hospitalization events, showed a 49 percent decreased number of hospitalization events in the Theranova arm (18 events) as compared to the control arm (37 events).\\38\\ With regard to improved medication usage, the applicant stated that patients receiving HDx therapy had reduced medication usage.","paper_id":7530,"paper_title":"Efficacy and Safety of Expanded Hemodialysis with the Theranova 400 Dialyzer: A Randomized Controlled Trial","paper_year":2020,"paper_doi":"10.2215/cjn.01210120"},{"citation_id":28376,"raw_reference":"Gallo, M., \"The Real-Life Study on Expanded Hemodialysis (HDx): 9 Months Experience of a Single Hemodialysis Unit,\" Nephrology Dialysis Transplantation, 34, Issue Supplement_1, June 2019, gfz106.FP539.","cited_authors":"Gallo, M.","cited_year":"2019","cited_title":"The Real-Life Study on Expanded Hemodialysis (HDx): 9 Months Experience of a Single Hemodialysis Unit","cited_venue":"Nephrology Dialysis Transplantation","cited_doi":"10.1093/ndt/gfz106.fp539","cited_url":null,"ref_kind":"conference_paper","section":"fn 39","page":null,"context_sentence":null,"paper_id":8251,"paper_title":"FP539THE REAL-LIFE STUDY ON EXPANDED HEMODIALYSIS (HDX): 9 MONTHS EXPERIENCE OF A SINGLE HEMODIALYSIS UNIT","paper_year":2019,"paper_doi":"10.1093/ndt/gfz106.fp539"},{"citation_id":28377,"raw_reference":"Lim, J-H., et al., \"Novel Medium Cut-Off Dialyzer Improves Erythropoietin Stimulating Agent Resistance in Maintenance Hemodialysis Patients: A Randomized Controlled Trial,\" Manuscript submitted for publication.","cited_authors":"Lim, J-H., et al.","cited_year":null,"cited_title":"Novel Medium Cut-Off Dialyzer Improves Erythropoietin Stimulating Agent Resistance in Maintenance Hemodialysis Patients: A Randomized Controlled Trial","cited_venue":"Manuscript submitted for publication","cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"fn 41","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":28378,"raw_reference":"Sanabria, R.M., et al. \"Expanded Hemodialysis and its effects on hospitalizations and medication usage,\" Submitted for publication.","cited_authors":"Sanabria, R.M., et al.","cited_year":null,"cited_title":"Expanded Hemodialysis and its effects on hospitalizations and medication usage","cited_venue":"Submitted for publication","cited_doi":"10.1159/000513328","cited_url":null,"ref_kind":"journal_article","section":"fn 37","page":null,"context_sentence":"A prospective cross-over study found an average of seven episodes of infection for patients treated with HDx versus 18 for high flux HD (p = 0.003).\\36\\ The applicant also stated that patients receiving HDx therapy with Theranova had hospital stays averaging 4.4 days versus 5.9 days for patients receiving traditional HD (p = 0.0001) along with lower hospitalization rates (71 percent versus 77 percent (p = 0.69)).\\37\\ The U.S.","paper_id":7537,"paper_title":"Expanded Hemodialysis and Its Effects on Hospitalizations and Medication Usage: A Cohort Study","paper_year":2021,"paper_doi":"10.1159/000513328"},{"citation_id":28379,"raw_reference":"Bolton, S., et al., \"Dialysis symptom burden and recovery time in expanded hemodialysis,\" Manuscript submitted.","cited_authors":"Bolton, S., et al.","cited_year":null,"cited_title":"Dialysis symptom burden and recovery time in expanded hemodialysis","cited_venue":"Manuscript submitted","cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"fn 46","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":28380,"raw_reference":"Wolley, M., et al., \"Exploring the Clinical Relevance of Providing Increased Removal of Large Middle Molecules,\" J Am Soc Nephrol, 2018, 13, pp. 805-813.","cited_authors":"Wolley, M., et al.","cited_year":"2018","cited_title":"Exploring the Clinical Relevance of Providing Increased Removal of Large Middle Molecules","cited_venue":"J Am Soc Nephrol","cited_doi":"10.2215/cjn.10110917","cited_url":null,"ref_kind":"journal_article","section":"fn 47","page":null,"context_sentence":null,"paper_id":8183,"paper_title":"Exploring the Clinical Relevance of Providing Increased Removal of Large Middle Molecules","paper_year":2018,"paper_doi":"10.2215/cjn.10110917"},{"citation_id":28381,"raw_reference":"Kirsch AH, Lyko R, Nilsson LG., et al. Performance of hemodialysis with novel medium cut-off dialyzers. Nephrol Dial Transplant 2017; 32: 165-172.","cited_authors":"Kirsch, A.H., et al.","cited_year":"2017","cited_title":"Performance of hemodialysis with novel medium cut-off dialyzers","cited_venue":"Nephrol Dial Transplant","cited_doi":"10.1093/ndt/gfw310","cited_url":null,"ref_kind":"journal_article","section":"fn 48","page":null,"context_sentence":null,"paper_id":7536,"paper_title":"Performance of hemodialysis with novel medium cut-off dialyzers","paper_year":2016,"paper_doi":"10.1093/ndt/gfw310"},{"citation_id":28382,"raw_reference":"Belmouaz, M., et al., \"Comparison of the Removal of Uremic Toxins with Medium Cut-Off and High Flux Dialyzers: A Randomized Clinical Trial,\" Nephrol Dial Transplant, 2020, 35, pp. 328-335.","cited_authors":"Belmouaz, M., et al.","cited_year":"2020","cited_title":"Comparison of the Removal of Uremic Toxins with Medium Cut-Off and High Flux Dialyzers: A Randomized Clinical Trial","cited_venue":"Nephrol Dial Transplant","cited_doi":"10.1093/ndt/gfz106.fp528","cited_url":null,"ref_kind":"journal_article","section":"fn 49","page":null,"context_sentence":null,"paper_id":8252,"paper_title":"FP528Comparison of the removal of uremic toxins with medium cut-off and high-flux dialyzers: a randomized clinical trial","paper_year":2019,"paper_doi":"10.1093/ndt/gfz106.fp528"},{"citation_id":28383,"raw_reference":"Kharbanda, K., et al., \"A Randomised Study Investigating the Effect of Medium Cut-Off Haemodialysis on Markers of Vascular Health Compared with On-Line Haemodiafiltration (MoDal Study)\". Poster presented at the American Society of Nephrology, 2019.","cited_authors":"Kharbanda, K., et al.","cited_year":"2019","cited_title":"A Randomised Study Investigating the Effect of Medium Cut-Off Haemodialysis on Markers of Vascular Health Compared with On-Line Haemodiafiltration (MoDal Study)","cited_venue":"American Society of Nephrology","cited_doi":null,"cited_url":null,"ref_kind":"conference_paper","section":"fn 50","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":28384,"raw_reference":"Cantaluppi, V., et al., \"Removal of Large Middle Molecules on Expanded Hemodialysis (HDx): A Multicentric Observantional Study of 6 Months Follow-Up,\" J Am Soc Nephrol, 29, 2018, Poster TH-PO 357.","cited_authors":"Cantaluppi, V., et al.","cited_year":"2018","cited_title":"Removal of Large Middle Molecules on Expanded Hemodialysis (HDx): A Multicentric Observantional Study of 6 Months Follow-Up","cited_venue":"J Am Soc Nephrol","cited_doi":null,"cited_url":null,"ref_kind":"conference_paper","section":"fn 52","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":28385,"raw_reference":"Caramelo, C., et al., \"Anemia: Pathophysiology, pathogenesis, treatment, incognitate,\" Rev Esp Cardiol., 2007, 60, pp. 848-60.","cited_authors":"Caramelo, C., et al.","cited_year":"2007","cited_title":"Anemia: Pathophysiology, pathogenesis, treatment, incognitate","cited_venue":"Rev Esp Cardiol","cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"fn 62","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":28386,"raw_reference":"Gillerot, G., et al. \"Genetic and Clinical Factors Influence the Baseline Permeability of the Peritoneal Membrane,\" Kidney Int. 2005, 67, pp. 2477-2487.","cited_authors":"Gillerot, G., et al.","cited_year":"2005","cited_title":"Genetic and Clinical Factors Influence the Baseline Permeability of the Peritoneal Membrane","cited_venue":"Kidney Int.","cited_doi":"10.1111/j.1523-1755.2005.00357.x","cited_url":null,"ref_kind":"journal_article","section":"fn 65","page":null,"context_sentence":"The applicant listed references for elevated levels of IL-6 leading to the following: Hepcidin production with decreased iron availability; \\62\\ increased endothelial damage; 63 64 increased CRP and decreased albumin production.\\65\\ The applicant attested that with the use of Theranova, patients present clinically with the opposite of each of the above listed concerns, suggesting that chronic inflammation mediated by IL-6 is reduced by treatment with Theranova.","paper_id":8255,"paper_title":"Genetic and clinical factors influence the baseline permeability of the peritoneal membrane","paper_year":2005,"paper_doi":"10.1111/j.1523-1755.2005.00357.x"},{"citation_id":28387,"raw_reference":"Jung, J.H., et al., \"A 6-Month Study on the Efficacy of Hemodialysis Therapy Using Dialyzers with Medium Cut-Off Membranes in Asian Patients with End-Stage Renal Disease,\" Nephrol Dial Transplant, June 2019. 84, Issue Supplement, gfz103.SP487.","cited_authors":"Jung, J.H., et al.","cited_year":"2019","cited_title":"A 6-Month Study on the Efficacy of Hemodialysis Therapy Using Dialyzers with Medium Cut-Off Membranes in Asian Patients with End-Stage Renal Disease","cited_venue":"Nephrol Dial Transplant","cited_doi":"10.1093/ndt/gfz103.sp487","cited_url":null,"ref_kind":"conference_paper","section":"fn 66","page":null,"context_sentence":"However, the applicant submitted a reference that concluded that when compared to HD using high flux membrane, HD using a medium cut-off (MCO) membrane may not be inferior in albumin loss.\\66\\ --------------------------------------------------------------------------- ---------------------------------------------------------------------------","paper_id":8253,"paper_title":"SP487A 6-MONTH STUDY ON THE EFFICACY OF HEMODIALYSIS THERAPY USING DIALYZERS WITH MEDIUM CUT-OFF MEMBRANES IN ASIAN PATIENTS WITH END-STAGE RENAL DISEASE","paper_year":2019,"paper_doi":"10.1093/ndt/gfz103.sp487"},{"citation_id":28388,"raw_reference":"Alarcon, J.C., et al., \"Real World Evidence on the Impact of Expanded Hemodialysis (HDx) Therapy on Patient Reported Outcomes (PROs): COREXH Registry,\" Manuscript submitted for Publication.","cited_authors":"Alarcon, J.C., et al.","cited_year":null,"cited_title":"Real World Evidence on the Impact of Expanded Hemodialysis (HDx) Therapy on Patient Reported Outcomes (PROs): COREXH Registry","cited_venue":"Manuscript submitted for publication","cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"fn 69","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":28389,"raw_reference":"Gernone, G., et al., \"Mid-term Evaluation of the New Medium Cut-Off Filter (Theranova) on Removal Efficiency and Quality of Life,\" Nephrology Dialysis Transplantation, 2018, ERA EDTA Scientific Congress Abstract, SP 489.","cited_authors":"Gernone, G., et al.","cited_year":"2018","cited_title":"Mid-term Evaluation of the New Medium Cut-Off Filter (Theranova) on Removal Efficiency and Quality of Life","cited_venue":"Nephrology Dialysis Transplantation","cited_doi":"10.1093/ndt/gfy104","cited_url":null,"ref_kind":"conference_paper","section":"fn 71","page":null,"context_sentence":null,"paper_id":8254,"paper_title":"NDT Abstract Supplement 2018","paper_year":2018,"paper_doi":"10.1093/ndt/gfy104"},{"citation_id":28390,"raw_reference":"Florens, N and Juillard, L., \"Expanded haemodialysis: News from the field,\" Nephrol Dial Transplant, 2018, 33, pp. iii48-iii52.","cited_authors":"Florens, N.; Juillard, L.","cited_year":"2018","cited_title":"Expanded haemodialysis: News from the field","cited_venue":"Nephrol Dial Transplant","cited_doi":"10.1093/ndt/gfy203","cited_url":null,"ref_kind":"journal_article","section":"fn 72","page":null,"context_sentence":null,"paper_id":8182,"paper_title":"Expanded haemodialysis: news from the field","paper_year":2018,"paper_doi":"10.1093/ndt/gfy203"},{"citation_id":28391,"raw_reference":"Penny, J., et al. \"Pruritus: ls there a salty truth?\" Submitted for publication.","cited_authors":"Penny, J., et al.","cited_year":null,"cited_title":"Pruritus: Is there a salty truth?","cited_venue":"Submitted for publication","cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"fn 76","page":null,"context_sentence":"proved physical functioning and decreased pruritus, the applicant submitted an article reporting the results of a randomized control trial (N=50), where Theranova resulted in improved results for physical functioning and physical role, and the mean scores of mean pruritus distribution and frequency of scratching during sleep were significantly lower with Theranova.\\74\\ In another study (single cohort, N=14), Theranova was associated with statistically significant improvement in the physical and mental component quality of life measures.\\75\\ The applicant also submitted a case report of a HD patient with pruritus who responded to the initiation of HDx using a MCO dialysis membrane.\\76\\ --------------------------------------------------------------------------- ---------------------------------------------------------------------------","paper_id":70513,"paper_title":"Pruritus: Is there a grain of salty truth?","paper_year":2020,"paper_doi":"10.1111/hdi.12885"}]}