{"document":{"doc_id":5660,"source":"fr_rule","org":"DEPARTMENT OF ENERGY","doc_type":"Rule","title":"Energy Conservation Program: Test Procedure for Room Air Conditioners","date":"2021-03-29","url":"https://www.federalregister.gov/documents/2021/03/29/2021-05415/energy-conservation-program-test-procedure-for-room-air-conditioners","source_native_id":"2021-05415","status":"fetched","abstract":"On June 11, 2020, the U.S. Department of Energy (\"DOE\") issued a notice of proposed rulemaking (\"NOPR\") to amend the test procedure for room air conditioners (\"room ACs\"). That proposed rulemaking serves as the basis for the final rule. Specifically, this final rule adopts the following updates to the test procedure for room ACs at appendix F: Incorporate by reference current versions of applicable industry standards; establish test provisions to measure energy use of variable-speed room ACs during a representative average use cycle; update definitions to define key terms and support provisions for testing variable-speed room ACs; and incorporate specifications and minor corrections to improve the test procedure repeatability, reproducibility, and overall readability. This final rule does not modify the test procedures for single-speed room ACs and does not affect the measured energy use for these models. The provisions established to measure energy use of variable-speed room ACs will improve the representativeness of the measured energy use of these models.","action":"Final rule."},"dockets":["EERE-2017-BT-TP-0012"],"rins":["RIN 1904-AD47"],"related":[{"doc_id":6967,"source":"fr_rule","org":"DEPARTMENT OF ENERGY","doc_type":"Proposed Rule","title":"Energy Conservation Program: Test Procedure for Room Air Conditioners","date":"2020-06-11"},{"doc_id":5706,"source":"fr_rule","org":"DEPARTMENT OF ENERGY","doc_type":"Rule (administrative)","title":"Energy Conservation Program: Test Procedure for Room Air Conditioners; Correction","date":"2021-05-07"},{"doc_id":4508,"source":"fr_rule","org":"DEPARTMENT OF ENERGY","doc_type":"Rule (administrative)","title":"Energy Conservation Program: Test Procedure for Room Air Conditioners","date":"2023-08-30"}],"references":[{"citation_id":24687,"raw_reference":"Palkowski, Carsten & Schwarzenberg, Stefan & Simo, Anne. (2019). “Seasonal cooling performance of air conditioners: The importance of independent test procedures used for MEPS and labels.” International Journal of Refrigeration. 104. 10.1016/j.ijrefrig.2019.05.021.","cited_authors":"Palkowski, Carsten; Schwarzenberg, Stefan; Simo, Anne","cited_year":"2019","cited_title":"Seasonal cooling performance of air conditioners: The importance of independent test procedures used for MEPS and labels","cited_venue":"International Journal of Refrigeration","cited_doi":"10.1016/j.ijrefrig.2019.05.021","cited_url":null,"ref_kind":"journal_article","section":"fn 27","page":null,"context_sentence":"their test mode.\\26\\ The California IOUs also cited research conducted at the Bundesanstalt f[uuml]r Materialforschung und -pr[uuml]fung (``BAM'') Federal Institute for Material Research and Testing in Germany, in which all but one of the seven residential mini-split air conditioners with variable-speed equipment that were tested consumed significantly higher energy when consumer-adjustable, built-in controls were used relative to fixed controls (i.e., controls that set the compressor speed using a manufacturer-provided remote or code).\\27\\ The California IOUs stated that researchers reported many units reverted to on-off (cycling) operation when the outdoor temperatures were between 77 and 86 [deg]F.","paper_id":7643,"paper_title":"Seasonal cooling performance of air conditioners: The importance of independent test procedures used for MEPS and labels","paper_year":2019,"paper_doi":"10.1016/j.ijrefrig.2019.05.021"},{"citation_id":24688,"raw_reference":"Greenberg, S. (1988). Technology Assessment: Adjustable-Speed Motors and Motor Drives. Lawrence Berkeley National Laboratory. LBNL Report #: LBL-25080. Retrieved from https://escholarship.org/uc/item/41z9k3q3.","cited_authors":"Greenberg, S.","cited_year":"1988","cited_title":"Technology Assessment: Adjustable-Speed Motors and Motor Drives","cited_venue":"Lawrence Berkeley National Laboratory, LBNL Report LBL-25080","cited_doi":null,"cited_url":"https://escholarship.org/uc/item/41z9k3q3","ref_kind":"research_report","section":"fn 38","page":null,"context_sentence":"However, the California IOUs commented that variable-speed motor controllers often have lower power factors compared to direct-on-line motors used in single-speed room ACs \\38\\ and requested that DOE indicate whether the room ACs tested included representative variable-speed compressor room ACs.","paper_id":66407,"paper_title":"Technology assessment: Adjustable-speed motors and motor drives: (Residential and commercial sectors)","paper_year":1988,"paper_doi":"10.2172/6266486"},{"citation_id":24689,"raw_reference":"2020-06 Technical Support Document: Energy Efficiency Program For Consumer Products And Commercial And Industrial Equipment: Room Air Conditioners (EERE-2014-BT-STD-0059-0013).","cited_authors":"U.S. Department of Energy","cited_year":"2020","cited_title":"2020-06 Technical Support Document: Energy Efficiency Program For Consumer Products And Commercial And Industrial Equipment: Room Air Conditioners","cited_venue":"Department of Energy","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"fn 35","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null}]}