Air Quality Criteria for Particulate Matter_Vol 1 [EPA/600/P-99/002aF]
Other documents for the same rulemaking (all, by stage)
References: 1,980 extracted, 11 linked to papers
PTEAM (Clayton et al., 1993; Özkaynak et al., 1996a,b) Netherlands (Janssen, 1998a; Suh et al., 1992) Necessary to treat personal exposure to ambient PM and personal exposure to nonambient PM as separate components of total personal PM exposure. Fixed-site ambient fine-particle measurements likely give a reasonable indication of the variability in the concentration of ambient fine particles across the community. Coarse-particle measurements most likely will not. Synoptic review of the “exposure paradox”: low correlations between personal exposure and ambient PM concentrations in spite of the existence of statistical association between ambient
PTEAM (Clayton et al., 1993; Özkaynak et al., 1996a,b) Examines the influence of nonambient PM on total PM concentrations and how it may confound the outdoor/personal
PTEAM (Clayton et al., 1993; Özkaynak et al., 1993, 1996a,b) Uses a reduced-form mass-balance model to predict the average fraction of ambient PM to which the average person is exposed. On average, a person is exposed to > 75% of ambient PM2.5 and > 64% of ambient PM10 measured by the community monitor.
Monn (2001) Multiple Literature Review Objective review of literature published since 1996 as an implicit update to the 1996 U.S. EPA PM AQCD. Emphasis on European studies. “It is important to note that a personal measurement does not a priori provide more valid data than a stationary ambient measurement, i.e. a personal sample in a study investigating effects from outdoor combustion particles is often influenced by sources other than outdoor sources and may thus confound the exposure-effect outcome.” Exposure to ambient PM is highly correlated in time with ambient PM concentrations measured at a community site. Indoor PM does not confound the relationship between daily mortality and ambient PM. 5-45 “Despite some lack of correlation between personal (PM10) and outdoor values, outdoor fine particle concentrations were strongly associated with mortality and morbidity indicating that outdoor sources (e.g. vehicular emissions) emit the toxic entity” (Dockery et al., 1993; Schwartz et al., 1996). Rotko et al. (2000a) Jantunen et al. (1998) Carrer et al. (1997) Koistinen et al. (1999) Compares exposure relationships between the six EXPOLIS European cities (Athens, Basel, Grenoble, Helsinki, Milan,
Mage (1998) conducted analysis using the PTEAM data and showed that the average person in PTEAM (Riverside, CA in the fall) was exposed to > 75% of ambient PM2.5 and > 64% of ambient PM10. Mage et al. (1999) used an algorithm to fill in missing data and outliers to analyze data sets and showed that variation in daily personal exposures for subjects with similar activity patterns and no ETS exposure are driven by variation in ambient PM concentrations. 5.3.3 Factors Influencing and Key Findings on Particulate Matter Exposures 5.3.3.1 Relationship of Personal/Microenvironmental Particulate Matter with Ambient Particulate Matter Understanding the relationship between ambient site measurements and personal exposure to PM is important for several reasons. First, it allows us to examine the extent to which ambient measurements for PM and various PM constituents can serve as valid surrogates for exposure to ambient PM or ambient constituents of PM in epidemiological studies. Second, it provides information that may improve surrogate exposure measurements and, hence, increase the power of epidemiologic studies. Finally, because compliance with the NAAQS is based on
AND CORRELATION COEFFICIENTS Personal-Ambient 2 Correlation Coefficients (r) Measured Concentration Levels (µg/m3) Size Fraction Avg. Time Statistic Sample Size1 Personal Residential Indoor Residential Outdoor Ambient Type3 Value (Range) 11.4 ± 4.1 4-29 Median L 0.48 (!0.68-0.83) 0.15 Other Correlation Coefficients (r) Notes Type3 Value (Range) Longitudinal Studies Ebelt et al. (2000) – Vancouver, BC PM2.5 24 h x) ± SD Range 18.2 ± 14.6 2-91 n = 16 COPD subjects Evans et al. (2000) – Fresno, CA 5-49 PM2.5 24 h Range 13.3 1-24 4-17 20.5 4-52 21.7 6-37 0.414 Fresno-1 study Pp-i Pp-o 0.814 0.804 PM2.5 24 h Range 11.1 7-16 4-12 10.1 5-20 4-16 0.844 Fresno-2 study Pp-i Pp-o 0.954 0.804 105.2 ± 28.7 57-195 38.5 ± 5.6 25-56 Median L Median L Median L Mean P Mean P Mean P 0.63 (0.1-0.9) 0.63 0.59 0.28 (0.12)5 0.45 (0.16)5 0.20 (0.19)5 61.7 ± 18.3
Abraham, J. L.; Siwinski, G.; Hunt, A. (2002) Ultrafine particulate exposures in indoor, outdoor, personal and mobile environments: effects of diesel, traffic, pottery kiln, cooking and HEPA filtration on micro-environmental particle number concentration. Ann. Occup. Hyg. 46(suppl. 1): 406-411.
Abt, E.; Suh, H. H.; Allen, G.; Koutrakis, P. (2000a) Characterization of indoor particle sources: a study conducted in the metropolitan Boston area. Environ. Health Perspect. 108: 35-44.
Abt, E.; Suh, H. H.; Catalano, P.; Koutrakis, P. (2000b) The relative contribution of outdoor and indoor particle sources to indoor concentrations. Environ. Sci. Technol. 34: 3579-3587.
Adams, H. S.; Nieuwenhuijsen, M. J.; Colvile, R. N.; McMullen, M. A. S.; Khandelwal, P. (2001) Fine particle (PM2.5) personal exposure levels in transport microenvironments, London, UK. Sci. Total Environ. 279: 29-44.
Adgate, J. L.; Ramachandran, G.; Pratt, G. C.; Waller, L. A.; Sexton, K. (2002) Spatial and temporal variability in outdoor, indoor, and personal PM2.5 exposure. Atmos. Environ. 36: 3255-3265.
W. (1985) Measuring human exposure to carbon monoxide in Washington, D.C., and Denver, Colorado, during the winter of 1982-1983. Environ. Sci. Technol. 19: 911-918.
D. (2000) Personal exposures to PM and gaseous air pollutants at the end of the 1991 Kuwait oil fires. Presented at: PM2000: particulate matter and health—the scientific basis for regulatory decision-making, specialty conference & exhibition; January; Charleston, SC. Pittsburgh, PA: Air & Waste Management Association.
Alm, S.; Jantunen, M. J.; Vartiainen, M. (1999) Urban commuter exposure to particle matter and carbon monoxide inside an automobile. J. Exposure Anal. Environ. Epidemiol. 9: 237-244.
M. (2000) Optical measurements of aerosol size distributions in Great Smoky Mountains National Park: dry aerosol characterization. J. Air Waste Manage. Assoc. 50: 665-676.
Q. (1998) Simultaneous indoor and outdoor particle light-scattering measurements at nine homes using a portable nephelometer. J. Exposure Anal. Environ. Epidemiol. 8: 483-493.
Baek, S.-O.; Kim, Y.-S.; Perry, R. (1997) Indoor air quality in homes, offices and restaurants in Korean urban areas–indoor/outdoor relationships. Atmos. Environ. 31: 529-544.
Bahadori, T. (1998) Human particulate exposure assessment: relationship between outdoor, indoor, and personal measurements (air pollution) [dissertation]. Boston, MA: Harvard University.
Bohadana, A. B.; Massin, N.; Wild, P.; Toamain, J.-P.; Engel, S.; Goutet, P. (2000) Symptoms, airway responsiveness, and exposure to dust in beech and oak wood workers. Occup. Environ. Med. 57: 268-273.
Brauer, M. (1995) Assessment of indoor aerosols with an integating nephelometer. J. Exposure Anal. Environ. Epidemiol. 5: 45-56.
Brauer, M.; Mannetje, A. (1998) Restaurant smoking restrictions and environmental tobacco smoke exposure. Am. J. Public Health 88: 1834-1836.
D. (1989) Personal exposures to acidic aerosols and gases. Environ. Sci. Technol. 23: 1408-1412.
D. (1990) Indoor and outdoor concentrations of acidic aerosols and gases. In: Indoor air '90: precedings of the 5th international conference on indoor air quality and climate, volume 2, characteristics of indoor air; July-August; Toronto, ON, Canada. Ottawa, ON, Canada: International Conference on Indoor Air Quality and Climate, Inc.; pp. 447-452.
Brauer, M.; Bartlett, K.; Regalado-Pineda, J.; Perez-Padilla, R. (1996) Assessment of particulate concentrations from domestic biomass combustion in rural Mexico. Environ. Sci. Technol. 30: 104-109.
R. (1999) Monitoring personal fine particle exposure with a particle counter. J. Exposure Anal. Environ. Epidemiol. 9: 228-236.
Cullen, A. (2000) Personal exposure to particles in Banská Bystrica, Slovakia. J. Exposure Anal. Environ. Epidemiol. 10: 478-487. 5-129
B. (1998) Predictability of personal exposure to airborne particulate matter from ambient concentrations in four communities. In: Vostal, J. J., ed. Health effects of particulate matter in ambient air. Proceedings of an international conference; 1997; Prague, Czech Republic. Pittsburgh, PA: Air & Waste Management Association; pp. 333-350. (A&WMA publication VIP-80).
Burke, J.; Zufall, M.; Özkaynak, H. (2001) A population exposure model for particulate matter: case study results for PM2.5 in Philadelphia, PA. J. Exposure Anal. Environ. Epidemiol. 11: 470-489.
Burton, R. M.; Suh, H. H.; Koutrakis, P. (1996) Spatial variation in particulate concentrations within metropolitan Philadelphia. Environ. Sci. Technol. 30: 400-407.
Buzorius, G.; Hämeri, K.; Pekkanen, J.; Kulmala, M. (1999) Spatial variation of aerosol number concentration in Helsinki city. Atmos. Environ. 33: 553-565.
Byrne, M. A.; Lange, C.; Goddard, A. J. H.; Roed, J. (1992) Indoor aerosol deposition studies using neutron-activatable tracers. J. Aerosol Sci. 23(suppl. 1): S543-S546.
L. (1957) A numerical analysis of the protection afforded by buildings against BW aerosol attack. Fort Detrick, MD: Office of the Deputy Commander for Scientific Activities; BWL tech. study no. 2.
Carrer, P.; Alcini, D.; Cavallo, D. (1997) Daily personal exposure to air pollutants of office workers in Milano. In:
Maroni, M. (1998) Personal exposure to PM10 of subjects living in Milan. In: Vostal, J. J., ed. Health effects of particulate matter in ambient air. Proceedings of an international conference; 1997; Prague, Czech Republic. Pittsburgh, PA: Air & Waste Management Association; pp. 359-365. (A&WMA publication
VIP-80). Cha, Q.; Chen, Y.-Z.; Du, Y.-X. (1996) Influence of indoor air pollution on quality of outdoor air in city of
T. (2002) Indoor-outdoor relationships of particulate matter and nitrogen oxides under different outdoor meteorological conditions. Atmos. Environ. 36: 1543-1551.
Y. (2002) Commuter exposure to particulate matter in public transportation modes in Hong Kong. Atmos. Environ. 36: 3363-3373.
H. (2000) Hourly personal exposures to fine particles and gaseous pollutants–results from Baltimore, Maryland. J. Air Waste Manage. Assoc. 50: 1223-1235.
Chang, L.-T.; Suh, H. H.; Wolfson, J. M.; Misra, K.; Allen, G. A.; Catalano, P. J.; Koutrakis, P. (2001) Laboratory and field evaluation of measurement methods for one-hour exposures to O3, PM2.5, and CO. J. Air Waste Manage. Assoc. 51: 1414-1422.
C. (2001) An empirical model for outdoor contaminant transmission into residential buildings and experimental verification. Atmos. Environ. 35: 1585-1596.
K. (1999) Polycyclic aromatic hydrocarbon exposures of children in low-income families. J. Exposure Anal. Environ. Epidemiol. 2: 85-98.
D. (1993) Particle total exposure assessment methodology (PTEAM) study: distributions of aerosol and elemental concentrations in personal, indoor, and outdoor air samples in a southern California community. J. Exposure Anal. Environ. Epidemiol. 3: 227-250.
L. (1999a) Estimating distributions of long-term particulate matter and manganese exposures for residents of Toronto, Canada. Atmos. Environ. 33: 2515-2526.
J. (1999b) National human exposure assessment survey (NHEXAS): distributions and associations of lead, arsenic, and volatile organic compounds in EPA Region 5. J. Exposure Anal. Environ. Epidemiol. 9: 381-392.
L. (1995) Transportation-related volatile hydrocarbon source profiles measured in Atlanta. J. Air Waste Manage. Assoc. 45: 383-394.
W. (2001) Chemical and physical characterization of indoor, outdoor, and personal samples collected in and around a retirement facility. In: Measurement of Toxic and Related Air Pollutants: proceedings of a specialty conference; September, 2000; Research Triangle Park,
H. (1977) Bias due to misclassification in the estimation of relative risk. Am. J. Epidemiol. 105: 488-495. 5-130
S. (2000) Manganese exposures in Toronto during use of the gasoline additive, methylcyclopentadienyl manganese tricarbonyl. J. Exposure Anal. Environ. Epidemiol. 10: 227-239.
T. (1998) Toxic volatile organic compounds in simulated enviromental tobacco smoke: emission factors for exposure assessment. J. Exposure Anal. Environ. Epidemiol. 8: 313-334.
Demokritou, P.; Kavouras, I. G.; Harrison, D.; Koutrakis, P. (2001) Development and evaluation of an impactor for a PM2.5 speciation sampler. J. Air Waste Manage. Assoc. 51: 514-523.