SO2 NAAQS 1971, 36 Federal Register 8186
Other documents for the same rulemaking (all, by stage)
References: 15 extracted, 0 linked to papers
FEDERAL REGISTER, VOL. 36, NO. 84-FRIDAY, APRIL 30, 1971
RULES AND REGULATIONS (5) Pate, J. B., and Tabor, E. C.. "Analytical Aspects of the Use of Glass-Fiber Filters for the Collection and Analysis of Atmospheric Particulate Matter", Am. lZd. Hyg. ASsoc. J. 23, 144-150 (1962). .ADDENDA .A. A ternativeEquipment. A modification of the high-volume sampler incorporating a method for recording the actual airflow over the entire sampling period has been described, and is acceptable for measuring the concentration of suspended particulates (Henderson. J.S.,Eighth Conference on Methods in Air Pollution and
Industrial Hygiene Studies, 1967. Oakland, Calif.). This modification consists of an exlhaust orifice meter assembly connected through a transducer to a system for continuously recording airflow on a circular chart. The volume of air sampled Is calculated by the following equation: V=QXT. Q=Average sampling rate, m. /mln. T=Sampling time, minutes. The average sampling rate, Q, isdetermined from the recorder chart by estimation if the flow rate does not vary more than 0.11 rn 3 / 2nin. (4 It./mn.) during -the sampling period. If the flow rate does vary more than 0.11 mLP (4 ft. lmin.) during the sampling period, read the flow rate from the chart at 2-hour intervals and take the average. B. Pressureand Temperature Corrections. If the prcaure or temprature during high-volume sampler calibration 13 cub;tantially different from the prc ura or tcmcra ture during orlilce callbration, a carrc-i-tln of the flow rate, Q, may ba rcqulrc:L If the prZ~urco differ by no more than 1G pcrccnt and the temperature differ by no more thnn 100 percent (OC), the errar in the uncorrected flow rate =ill be no oro thzn 15 percent. If ncwary. obtain the caerrcted flow rate as directed below. ThIs correction applIes only to orifice moters havlng a constant orifico caciflent. The cecilent for the calibrating orifice dc:rlbed In 5.1.4 ha been chown experLmentally to ba constant over the normal opcratmng range of the hlghvolume ca=mpler (0.6 to 2 mNmln.; 20 to 73 ft.P/min.). Calculate corrected flow rate:
NO. 81---t, 1I-2 rc:-;~f zls. FEDERAL REGISTER, VOL 36, NO. 84-FRIDAY, APRIL 30, 1971 8193
California, Berkeley, Calif., April 1, 1970.
Jacobs, B. B. et al., J.A.P.C.A. 9, No. 2, 110114, August 1959. M A LIRA Infrared Gas and Liquid Analyzer Instruction Book, Mine Safety Appliances Co., Pittsburgh, Pa. Beckman Instruction 1635B, Models 215A, 315A and 415A Infrared Analyzers, Beckman Instrument Company, Fullerton, Calif. Continuous CO Monitoring System, Model A-5611, Intertech Corp., Princeton, N.J. Bendix-UNOR Infrared Gas Analyzer,.
Symposium, Houston, Texas, April 10-21, 1971.
Stevens, n. X., "The Automated Gas Chromatograph as an Air Pollutant Monitor", 1970 Conference on Environmental
Stevens, R. K., and O'Kceffo, A. V., Anal. Chem. 42, 143A (1970).
Schuck, E. A., Altshuller, A. P., Barth, D, S. and Morgan, G. B., "Relationship of Hydrocarbons to Oxidants In Ambient Atmospheres", J. Air Poll. Cont. Assoo. 20, 297-302 (1970).
Williams, 1. G., Advances in ChromatoraphV, Giddings, J. C,, and Keller, n. A., edItors, Marcell Dekker, N.Y. (1960), pp. 178182.
Altshuller, A. P., Kopcznsld, S. L., Lonnamn, W. A., Becker, T. L. and Slater, n., Environ. Sd. Technol. 1, 899 (1907).
Porter, K., and Volmann, D. H., Anal. Chem, 34,748-749 (1962).
FEDEIAL REGISTER. VOL 36. NO. 84-FRIDAY, APRIL 30, 1971
FEDERAL REGISTER, VOL 36, NO. 84-FRIDAY, APPIL 30, 1971 Slitcrckri!n 8200