Method 521: Determination of Nitrosoamines in Drinking Water by Solid Phase Extraction and Capillary Column Chromatography with Large Volume Injection and Chemical Ionization Tandum Mass Spectrometery (MS/MS) Version 1.0 EPA/600/R-05/054
Other documents for the same rulemaking (all, by stage)
References
2. Glaser, J.A., D.L. Foerst, G.D. McKee, S.A. Quave, and W.L. Budde, "Trace Analyses for Wastewaters”, Environ. Sci. Technol., 15 (1981) 1426-1435.
3. Wilczak, A., et al, “Formation of NDMA in Chloraminated Water Coagulated with Dadmac Cationic Polymer”, J. AWWA, 95 (2003) 94-106.
Press, Cambridge, UK, 1992. 5. Preussmann, R, and B.W. Stewart, “N-Nitroso carcinogens, in: C.E. Searle (ed.), “Chemical
Carcinogens, American Chemical Society Monograph No. 182", (1984) 643-828. 6. "Carcinogens - Working With Carcinogens," Department of Health, Education, and Welfare, Public Health Service, Center for Disease Control, National Institute for Occupational Safety and
Health, Publication No. 77-206, Aug. 1977. 7. "OSHA Safety and Health Standards, General Industry," (29CFR1910), Occupational Safety and Health Administration, OSHA, (Revised, July 1, 2001). 8. "Safety in Academic Chemistry Laboratories," American Chemical Society Publication, Committee on Chemical Safety, 6th Edition, available from the ACS Office of Society Services by e-mail at OSS@acs.org. 9. Anspec of Ohio, 12 W. Selby Blvd., Ste. 4, Columbus, OH; telephone 1-800-521-1720.
10. Engewald, W., J. Teske, and J. Efer, “Programmed temperature vaporiser-based injection in capillary gas chromatography”, Journal of Chromatography A, 856 (1999) 259-278.
11. Mol, H.G.J., M. Althuizen, H. Janssen, C.A. Cramer and U. Brinkman, “Environmental Applications of Large Volume Injection in Capillary GC Using PTV Injectors”, J. High Resol. Chromatogr., 19 (1996) 69-79. 12. “Large Volume sample introduction using programmed-temperature injection systems”, Chromatography Technical Notes No 11, ATAS International BV, http://atasgl.in2it.nl/apnote/TECHNNO_11.pdf, accessed June 21, 2004. 521-33
CI maximum ionization time (:sec) 2000 CI maximum reaction time (:sec)
CI reaction storage level (m/z) CI background mass (m/z) Emission current (:amps) Electron Multiplier offset (V) +100 Table 2b. Chemical Ionization Parameters for a Varian Saturn 2000 GC/MS/MS Using Methanol or Acetonitrile as the CI Reagent
CI storage level (m/z) 15-19 Ejection amplitude (m/z) 10-15 Background mass (m/z) Maximum ionization time (:sec) 2000 Maximum reaction time (:sec) 100-120 Target total ion current (TIC) (counts) 5000 Prescan Ionization time (:sec) 100-200 Emission current (:amps) Electron Multiplier offset (V) +300 521-35 Table 3. Chromatographic Conditions including LVI Using a PTV Injector Injector Temperature program Varian Saturn 4 Varian Saturn 2000 Temp (°C) Rate (°C/min) Time (min) Temp (°C) Rate (°C/min) Time (min) 0.72 2.13 2.13 23.00 Injector Split Vent Program Varian Saturn 4 Varian Saturn 2000 Time (min) Split status Time (min) Split status open a open b 0.70 closed closed 2.00 open a open c a. split flow 100 mL/min b. split ratio 25 c. split ratio 100
GC Oven Temperature Program Varian Saturn 4 Varian Saturn 2000 Temp (°C) Rate (°C/min) Hold Time (min) Temp (°C) Rate (°C/min) Hold Time (min) 20.0 521-36 Table 4. Retention Times and Suggested Product Ions for Quantitation of Method Analytes in Tandem Mass Spectrometry (MS/MS) Mode a, b Analyte Retention Time (min) Precursor Ion (m/z) Product Ion/ Quantitation Ion (m/z)