EXECUTIVE SUMMARY INTRODUCTION There has been increased interest in residential indoor air quality issues in recent years. Previous studies have found higher concentrations of some pollutants inside homes than in the surrounding ambient atmosphere. The Alaska Building Energy Efficiency Standard that was adopted in 1992 provides guidance on ventilation methods aimed at reducing humidity and moisture problems in homes. The effectiveness of these methodologies on removing toxic pollutants such as carbon monoxide and benzene is largely unknown. This study monitored carbon monoxide, benzene, temperature, relative humidity and particulates inside 65 homes in Anchorage, Juneau, Fairbanks, and the Kenai Peninsula that were built since the adoption of the standard. These homes had a range of ventilation systems including intermittent bath/kitchen exhaust only; whole-house exhaust/passive supply; and balanced heat recovery ventilation (HRV). All of the homes were occupied during the study period.
METHODOLOGY Instruments placed in each home monitored CO, benzene, %RH and temperature for a two-day period during the winter of 2002. CO, temperature and %RH were measured continuously with average values stored every two-to -ten minutes. Passive sampling badges incorporating an activated carbon absorption element were used to determine average benzene concentrations. Parameter Measured Units of Measure Carbon Monoxide Benzene Relative Humidity Temperature Parts per million (ppm) Parts per billion (ppb) Percent (%) Degrees Fahrenheit (°F) At the time instruments were deployed, field investigators also performed a walkthrough of the building to identify and record building characteristics, ventilation and heating system characteristics, moisture problems, and other possible architectural and environmental factors that might affect pollutant concentrations. Participants in the study were asked to complete a questionnaire relating to their homes (type, size, cooking fuel, heating system, ventilation system) and activities (times when they typically cook, when the heating is on, whether they smoke etc.) during the course of monitoring. The information obtained from the questionnaires was analyzed to identify activities which may affect pollutant concentration. 2002 Indoor Air Quality and Ventilation Strategies In New Homes in Alaska - Final Report September
Schlapia, A. and Morris, S., Architectural, Behavioral an Environmental Factors Associated with VOCs in Anchorage Homes 98-A504; Anchorage Air Pollution Control Agency, Anchorage, Alaska, 1998.
Wallace LA, Pellizzari ED, Hartwell T, Perritt K, Ziegenfus R. Exposures to benzene and other volatile organic compounds from active and passive smoking. Arch Environ Health 42:272-279 1987. Benzene - The Tenth Report on Carcinogens. U.S. Department of Health and Human Services Public Health Service National Toxicology Program (2002), 2.0 MB PDF, 6 pages. This is a document that explains the carcinogenicity, properties, use, production, exposure, and regulations regarding benzene.
Wallace LA. The TEAM Study: Summary and Analysis. Vol 1. EPA 600/6-87/002a. NTIS PB 88-100060. Washington: U.S. Environmental Protection Agency, 1987.
IARC Monographs on the Evaluation of the Carcinogenic Risk of Chemicals to Humans. Some Industrial Chemicals and Dyestuffs. Vol. 29. 416 pp. Lyon, France: IARC, 1982. Toxicological profile for benzene. Agency for Toxic Substances and Disease Registry (ATSDR). 1997.
Atlanta, GA: U.S. Department of Health and Human Services, Public Health Service Department of Environment. Expert Panel on Air Quality Standards, Benzene), London, Ontario, CA, 1994. Minimal Risk Levels (MRLs) for Hazardous Substances. Agency For Toxic Substances and Disease
Registry. 2001. Minimal Risk Levels (MRLs) for Hazardous Substances Agency for Toxic Substances and Disease Registry (ATSDR); Atlanta, GA: U.S. Department of Health and Human Services, Public Health Service; 2003.
Schlapia, A. and Morris, S., Architectural, Behavioral an Environmental Factors Associated with VOCs in anchorage Homes 98-A504; Anchorage Air Pollution Control Agency, Anchorage, Alaska, 1998.
BNL 51171, November 1979. Billick, Irwin H.; Altpeter, L.L., Jr; Current Directions of the Gas Research Institute's Program on Indoor Air Quality: Analysis of Carbon Monoxide Safety. Gas Research Institute, Chicago, IL; 1993. The Inside Story: A Guide to Indoor Air Quality. United States Environmental Protection Agency and the United States Consumer Product Safety Commission Office of Radiation and Indoor Air (6604J) EPA Document # 402-K-93-007, April 1995. The Inside Story: A Guide to Indoor Air Quality. United States Environmental Protection Agency and theUnited States Consumer Product Safety Commission Office of Radiation and Indoor Air (6604J) EPA Document # 402-K-93-007, April 1995.
Gosink, Tom. What Do Carbon Monoxide Levels Mean? Alaska Science Forum Article #588; January 28, 1983. Geophysical Institute, University of Alaska Fairbanks.
Brown, Stephen; Indoor Air Pollutants; Sources, Health Effects and Measurements; CSIRO Building, Construction & Engineering, Highett; Australia; 1994.
Penney, David G, Ph.D. Ed., Carbon Monoxide Toxicity. CRC Press, June, 2000.
CO - How Carbon Monoxide Affects the Way We Live and Breathe. US Environmental Protection Agency, Office of Air Quality Planning & Standards November 2000. National Ambient Air Quality Standards. EPA Office of Air Quality Planning & Standards, following Clean Air Act of 1990
EPA'S Revised Particulate Matter Standards, U.S. Environmental Protection Agency, July 1997 Health Canada; Exposure Guidelines for Residential Indoor Air Quality A Report of the Federal-Provincial Advisory Committee on Environmental and Occupational Health; July 1989.
Schwartz, Joel, Assessing Life-Shortening Associated with Exposure to Particulate Matter, Harvard University 2000
Alaska Housing Finance Corporation, 2000.
Schlapia, A. and Morris, S., Architectural, Behavioral an Environmental Factors Associated with VOCs in Anchorage Homes 98-A504; Anchorage Air Pollution Control Agency, Anchorage, Alaska, 1998. Indoor Air Quality and Ventilation Strategies In New Homes in Alaska - Final Report September 2002 Additional Resources
Niven, R., Watson, A., Frank, T., “Indoor air pollutants, damp, endotoxin and house dust mite as environmental factors in the aetiology of asthma”; Manchester Metropolitan University; November 2001; http://www.doc.mmu.ac.uk/aric/research/ideamp.pdf
Perspectives, Volume 104, Supplement 6, December 1996; U.S. Environmental Protection Agency,
Reston, Virginia Young, A. et. al. “Carbon Monoxide Concentrations and Ventilation Strategies in Dwellings”, Bartlett School of Graduate Studies, London, 1998 Internet Resources American Lung Association: http://www.lungusa.org/ Benzene Info Center: http://www.benzeneinfocenter.com/ Centers For Disease Control and Prevention: http://www.cdc.gov Indoor Air Quality Association, Inc.: http://www.iaqa.org/guidelines.htm Health Canada: Exposure Guidelines on Indoor Air Quality: http://www.hc-sc.gc.ca U. S. Environmental Protection Agency: http://www.epa.gov/oar/aqtrnd97/brochure/pm10.html National Environmental Technology Centre, UK Department of the Envronment, Transport and the Regions: http://www.aeat.com/netcen/airqual/dailystats/standards.html National Environmental Technology Centre, UK Department of the Environment: http://www.aeat.com.netcen/airqual Occupational Safety and Health Administration, US Dep. of Labor: http://www.osha-slc.gov 2002 Indoor Air Quality and Ventilation Strategies In New Homes in Alaska - Final Report September
NADCA 1992-01 Chemical Parameters 6.1 Carbon Monoxide 9 ppm
Molhave, 1990 0.06 mg/m3 (0.05 ppm) Health & Welfare Canada 300 CFU/m3 total; 50 CFU/m3 individual (excepting Cladosporium) Robertson, 1997 500 CFU/m3 total; dominated by gram + organisms Indoor Air Quality and Ventilation Strategies In New Homes in Alaska - Final Report September 2002 Indoor Air Quality Association, Inc., 10400 Connecticut Avenue,Suite 510, Kensington, MD 20895 Phone: (301) 962-3804, Fax: (301) 962-3806, E-mail: iaqa@aol.com 2002 Indoor Air Quality and Ventilation Strategies In New Homes in Alaska - Final Report September Health Canada: Exposure Guidelines for Residential Indoor Air Quality Summary of Exposure Guidelines Contaminant Carbon Dioxide Carbon Monoxide Formaldehyde Nitrogen Dioxide Ozone Particulate Matter (PM 2.5) Sulphur Dioxide Water Vapor Acceptable Short-Term Exposure Range: ASTER ≤ 11 ppm – 8 hr ≤ 25 ppm – 1 hr Action Level: 120 µg/m³ (≤0.12 ppm) ≤480 µg/m³ (≤0.25 ppm) -1 hr ≤240 µg/m³ (≤0.12 ppm)- 1 hr ≤100 µg/m³ - 1hr ≤1000 µg/m³ (≤0.38 ppm)- 5 min 30-80% R.H -summer 30-55% R.H – winter (unless constrained by window condensation) Acceptable Long-Term Exposure Range: ALTER ≤ 6300 mg/m3 (≤ 3500 ppm) Target Level:60 µg/m³ (≤0.12 ppm) ≤100µg/m³ (≤0.05 ppm) ≤40 µg/m³ ≤50 µg/m³ (≤0.019 ppm) Radon Indoor Air Quality and Ventilation Strategies In New Homes in Alaska - Final Report September 2002