Synthesis of the 2014 Reports of the Scientific, Environmental Effects, and Technology & Economic Assessment Panels of the Montreal Protocol
Original sourceAttachment (8.5 MB)Attachment (3.2 MB)Attachment (1.8 MB)Attachment (35.0 MB)
Other documents for the same rulemaking (all, by stage)
References: 631 extracted, 409 linked to papers
Ashfold et al. (2014)
Zhang, Junjie and Can Wang, "China's Hydrofluorocarbon Challenge", Nature Climate Change, Vol.4, November 2014, pp.943-945
S. A. Montzka, M. McFarland, S. O. Andersen, B. R. Miller, D. W. Fahey, B. D. Hall, L. Hu, C. Siso, and J. W. Elkins, Recent Trends in Global Emissions of Hydrochlorofluorocarbons and Hydrofluorocarbons: Reflecting on the 2007 Adjustments to the Montreal Protocol, J. Phys. Chem., 2015
M. Rigby, R.G. Prinn, S. O'Doherty, B.R. Miller, D. Ivy, J. Muehle, C.M. Hart, P.K. Salameh, T. Arnolds, R.F. Weiss, P.B. Krummel, L.P. Steele, P.J. Fraser, D. Young and P. Simmonds, "Recent and future trends in synthetic greenhouse gas radiative forcing", Geophysical Research Letters, 10.1002/2013GL059099
UNEP, Refrigeration, AC and Heat Pumps Technical Options Committee, 2010 Assessment Report, ISBN 978-9966-20-002-0
Myhre, G., D. Shindell, F.-M. Bréon, et al., 2013. Anthropogenic and Natural Radiative Forcing. In: Climate Change 2013: The Physical Science Basis. Contribution of Working Group I to the Fifth Assessment Report of the IPCC
ISO 817: 2014. Refrigerants — Designation and safety classification. International Organization for Standardization (ISO)
Chin and Spatz (1999) conducting simulations comparing R410A to HCFC-22 at 52°C ambient
Domanski and Payne (2002) carried out measurements of a unitary air conditioner to compare HCFC-22 and R-410A
Devotta et al. (2005a) found a 2-8% drop in capacity and 8-14% increase in COP when a window type HCFC-22 air conditioner was retrofitted with R-407C.
Tu, Liang, and Zhuang (2011) compared the performance of HFC-32 and R-410A with actual tests carried at 43°C and 48°C ambient.
Biswas and Cremaschi (2012) measured the performance of some unassigned mixtures at fairly high ambient temperatures.
Chen (2012) reported a number of tests on split air conditioners using HCFC-22, HC-290, R-410A and HFC-32
Hamed (2012) also reported on tests with HC-290, HCFC-22, HFC-134a, R-407C and R-410A in an air-to-air (rooftop) air conditioner.
Eltalouny (2014) described the differences between PRAHA and AREP
Amrane, 2013 (AREP phase I testing of 38 refrigerant candidates)
Amrane, K. Overview of AHRI Research on Low-GWP Refrigerants. Webinar Aug 2013
Chen, Z.H., Research on Rotary Compressors Based on R-290 Technology. Proc. UNEP conference on technologies for high ambient conditions, Dubai, 2012.
Hamed, S., Using HC and HFC refrigerants in rooftop package units Which refrigerant is the future?, Proc. UNEP conference on technologies for high ambient conditions, Dubai, 2012.
Sethi, A., Low GWP Replacements for R-410A in Air Conditioning Applications., Proc. 2013 ASHRAE Summer Meeting, Denver, CO, USA.
Tu, X. et al., Study of R-32 Refrigerant for Residential Air-Conditioning Applications, International Conference on Refrigeration, Prague 2011.
2014 Refrigeration, Air Conditioning and Heat Pumps Technical Options Committee Assessment Report, edition published 2015
Price, D., Valovirta, E., and Fischer, J., The Importance of preserving choice in inhalation therapy: the CFC transition and beyond, Journal of Drug Assessment 2004; 7: 45-61.
Aerosol Market Analysis by Application (Personal Care, Household, Paint, Medical) and Segment Forecasts to 2020, Grand View Research, December 2014, ISBN 978-1-68038-288-4
Li and Rajewski, 2000. Experimental Study of Lubrication Candidates for the CO2 Refrigeration System. Proc. 4th IIR-Gustav Lorentzen Conference on Natural Working Fluids, Purdue University.
Linton, J. W.; Snelson, W. K.; and Hearty, P. F., 2000. Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10.0 SEER 10.5 kW residential central heat pump. Proc. Int. Refrig. and Air Condition. Conf. at Purdue.
Piao, C-C, Taira, S., Moriwaki, M., Tanimoto, K., Mochizuki, K., Nakai, A., 2012. Alternatives to High GWP HFC Refrigerants: Residential and Small Commercial Unitary Equipment. Proc. 2012 ASHRAE/NIST Refrigerants Conference.
Yajima, R., Kita K., Taira S., Domyo N., 2000. R32 as a Solution for Energy Conservation and Low Emission. Proc. Int. Refrig. and Air Condition. Conf. at Purdue.
Barve, A., Cremaschi, L., 2012. Drop-in Performance of Low GWP Refrigerants in a Heat Pump System for Residential Applications. Proc. Int. Refrig. and Air Condition. Conf. at Purdue.
Crawford, T., Uselton, D., 2012. Test Report #4 System Drop-in Test of Refrigerant R-32 in Split System Heat Pump. AHRI Low-GWP AREP, Arlington, USA.
Padalkar, A. S., Mali, K. V., Devotta S., 2011. Prospective of HFC-161 as an Alternative to HCFC-22 in Air Conditioners. Proc. IIF-IIR Int. Congr. Refrig., Prague.
Leck, T., Hydutsky, B., 2013. Laboratory Studies of Stability of Low GWP Refrigerants. Proc. IIF-IIR Thermophysical and Transport Properties Conference, Delft.
Han, X-H, Qiu, Y., Li, P., Xu, Y-J., Wang, Q., Chen, G-M., 2012. Cycle performance studies on HFC-161 in a small-scale refrigeration system as an alternative refrigerant to HFC-410A. Energy and Buildings, Vol. 44, 33–38.
Colbourne, D., Hühren, R., Rajadhyaksha, D., De Souza, L., Sahu, A., 2013. Refrigerant leakage control for R-290 in split type refrigeration and air conditioning systems. Proc. IIF-IIR Compressors 2013, Slovakia.
Zhang, W., Yang, Z., Li, J., Ren, C-X., Lv, D., Wang, J., Zhang, X., Wu, W., 2013. Research on the flammability hazards of an air conditioner using refrigerant R-290. Int. J. Refrig., Vol. 36, Issue 5, 1483-1494.
Li, T. X., 2014a. Indoor leakage test for safety of R-290 split type room air conditioner. Int. J. Refrig., Vol 40, 380–389.
Colbourne, D., Suen, K. O., 2004. Appraising the Flammability Hazards of Hydrocarbon Refrigerants using Quantitative Risk Assessment Model. Part II: Model evaluation and analysis. Int. J. Refrig., Vol. 27, 784 – 793.
Colbourne, D. 2014. Comparative Risk Assessment of Hydrocarbon Refrigerant in a Refrigerator and Split Air Conditioner. Proc. IIF-IIR Conf. on Natural Working Fluids, Hangzhou, China.
Zhou, X. F., 2014. HCFC phase out progress report in RAC sector. Proc. Int. Techn. Conf. Alternative Technology to HCFC-22 in Room Air-conditioner Sector, Ningbo, China.
Lin, K., Jin, T-X., Zhang, J., You, S-Y., Liu, Y., Zheng, Z-Y., 2010. Experiment on performance of Residential Air Conditioner with R-1270 to replace R-22. J. Refrig., Vol 31(3), 33-36. [In Chinese]
Wu, J.H., Yang, L.D., Hou, J., 2012a. Experimental performance study of a small wall room air conditioner retrofitted with R290 and R1270. Int. J. Refrig. 35 (7), 1860-1868.
Elbel, S., Hrnjak, P., 2008. Ejector Refrigeration: An Overview of Historical and Present Developments with and Emphasis on Air-Conditioning Applications. Proc. Int. Refrig. and Air Condition. Conf. at Purdue.
Jakobsen, A., Skiple, T., Nekså, P., Wachenfeldt, B. and Skaugen, G., 2007. Development of a reversible CO2 residential air conditioning system. Proc. IIF-IIR 22nd Int. Congr. Refrig., Beijing.
Sethi, A., 2013. Low GWP Replacements for R-410A in Air Conditioning Applications. Proc. 2013 ASHRAE Summer Meeting, Denver, CO, USA.
Sethi, A., Yana Motta, S., Becerra, E. V., Spatz, M. W., 2014. Low GWP Refrigerants for Air Conditioning Applications. Proc. Int. Refrig. and Air Conditioning Conf. at Purdue.
ICF International, 2006. Projected Servicing Needs in the U.S. Air-Conditioning and Refrigeration Sector, Prepared for the U.S. EPA, Washington DC.
GIZ, 2010. Guidelines for the safe use of hydrocarbon refrigerants, GTZ Proklima, Eschborn, Germany.
Spatz, M. W. and Richard, R. G., 2002. Performance and Oil Return Characteristics of HFC/HC Blends. Proc. Int. Refrig. and Air Condition. Conf. at Purdue.
Allgood, C. C., Lawson, C. C., 2010. Performance of R-438A in R-22 Refrigeration and Air Conditioning Systems. Proc. Int. Refrig. and Air Condition. Conf. at Purdue.
Messineo, A., Rocca, V.L., Panno, G., 2012. On-site experimental study of HCFC-22 substitution with HFCs refrigerants. Energy Procedia 14, pp. 32-38.