Test Report: Agrium U.S., Inc. Sacramento Nitrogen Operations West Sacramento, California
Other documents for the same rulemaking
References: 8 extracted, 0 linked to papers
EPA 4 Parameter 10088.0C Agrium U.S., Inc. - SNO 2010 Nitric Acid Plant
Agrium U.S., Inc. - SNO 2010 Nitric Acid Plant
EPA Information Collection Request June 21, 2010 includes software for controlling the collection of calibration and emission monitoring data, and hardware for connection of the analyzer outputs to the recording system. Test results are provided in the form of on-site printouts of the digitized data. 3.3.2 Fourier Transformed Infrared Spectroscopy Introduction Extractive Fourier Transform infrared (FTIR) spectroscopic testing for nitric oxide and nitrogen dioxide was performed on the exhaust of a nitric acid plant at the Agrium facility in Sacramento, CA. Testing was performed on May 12, 2010 by The Avogadro
EPA Information Collection Request June 21, 2010 their appropriate performance during the sampling runs. Second, our laboratory manager examines the sample spectra and the quantitative analytical results, and also spot-checks the analysis results by hand; these examinations include visual comparisons of the sample and reference spectra. Examples of the reference and sample spectra are illustrated in Figure 3-1. Test Method Validation
EPA Information Collection Request June 21, 2010 Sample 1915 1910 1905 1900 1895 1890 1885 1880 1875 Sample 2930 2920 2910 2900 2890 2880 2870 2860 Wavenumber (cm‐1) Figure 3-1. Selected Spectra. Red: Sample spectrum, Green: Nitric Oxide reference spectrum, Purple: Nitrogen Dioxide reference spectrum, Blue: Water reference spectrum 10088.0C
EPA Information Collection Request 3.3.3 June 21, 2010 Volumetric Flow Rates The mass emission rate for NOX was determined by calculations based on measurements of stack gas volumetric flow rate and moisture content using EPA Methods 2 and 4 respectively. The calculated flow rate was used with the measured emission concentrations to calculate mass emission rates in units of lb/hr and lb/ton. These emission rates in conjunction with process rate data in units of tons/day allowed calculation of emission rates in terms of lb/ton. 3.3.4 Process Data Process operating data were collected by Agrium personnel. Manual readings were taken from the plant’s calibrated nitric acid production meter. The plant nitric acid production rates were used to document process rate and in the calculation of mass emission rates in units of lb/ton. 10088.0C
EPA Information Collection Request June 21, 2010
AGRIUM U.S., INC. MAY 12, 2010 Parameter Date Time Plant Production, tons/hr Stack Conditions O2, % vol. dry CO2, % vol. dry