Ozone Criteria Document, [EPA 600/R-05/004aF]
Original sourcePDF at sourceAttachment at sourceAttachment at source
Other documents for the same rulemaking
References
P. (1980) Atmospheric bromine and ozone perturbations in the lower stratosphere. J. Atmos. Sci. 37: 339-353.
B. (1979) Nitrate photolysis in seawater by sunlight. Mar. Chem. 8: 33-42.
R. (1999) The role of mineral aerosol in tropospheric chemistry in East Asia--a model study. J. Appl. Meteorol. 38: 353-366.
Y. (2002) Mechanism of OH formation from ozonolysis of isoprene: kinetics and product yields. Chem. Phys. Lett. 358: 171-179.
Zhou, X.; Mopper, K. (1990) Determination of photochemically produced hydroxyl radicals in seawater and freshwater. Mar. Chem. 30: 71-88.
Zimmermann, J.; Poppe, D. (1993) Nonlinear chemical couplings in the tropospheric NOx–HOx gas phase chemistry. J. Atmos. Chem. 17: 141-155. AX2-189
TAR 4 11 models Lelieveld and Dentener (2000) StratosphereTroposphere Exchange (STE) Chemical Production 2 Chemical Loss 2 Deposition Burden (Tg) Lifetime (days) 3 770 ± 400 3420 ± 770 3470 ± 520 770 ± 180 300 ± 30 24 ± 2 3310 3170 AX3-146 Bey et al. (2001a) 5
CARB: Adolescents and Adults Oct 1987-Sept 1988 12-94 1762 Retrospective 24-h Standard Robinson et al. (1991) Wiley et al. (1991a)
CARB: Children Apr 1989-Feb 1990 0-11 1200 Retrospective 24-h Standard Wiley et al. (1991b) Cincinnati (EPRI) Mar-Apr and Aug 1985 0-86 2614 Diary 24 h; nominal 7 pm-7 am Johnson (1989) 3 consecutive days; 186 P-D removed7 Denver (EPA) Nov 1982-Feb 1983 18-70 Diary 24 h; nominal 7 pm-7 am Akland et al. (1985)
Johnson (1984) Part of CO PEM6 study; 2 consec. days; 55 P-D removed7 Los Angeles: Elem. School Children Oct 1989 10-12 Diary 24-h Standard Spier et al. (1992) 7 P-D removed7 Los Angeles: High School Adoles. Sept-Oct 1990 13-17 Diary 24-h Standard Spier et al. (1992) 23 P-D removed7 National: NHAPS-A8 Sept 1992-Oct 1994 0-93 4723 Retrospective 24-h Standard Klepeis et al. (1995) Tsang and Klepeis (1996) A national random-probability survey National: NHAPS-B8 As above 0-93 4663 Retrospective 24-h Standard As above As above University of Michigan: Children Feb-Dec 1997 0-13 5616 Retrospective 24-h Standard Institute for Social Research (1997) 2 days of data: one is a weekend
Valdez, AK Nov 1990-Oct 1991 11-71 Retrospective Varying 24-h period Goldstein et al. (1992) 4 P-D removed7
Washington, DC (EPA) Nov 1982-Feb 1983 18-98 Diary 24 h; nominal 7 pm-7 am Akland et al. (1985) Hartwell et al. (1984) Part of a CO PEM6 study; 6 P-D removed7 Multiple days, varying from 5-15; part of a PM2.5 PEM study All studies included both genders. The age range depicted is for the subjects actually included; in most cases, there was not an upper limit for the adult studies. Ages are inclusive. Age 0 = babies < 1 year old. The actual number of person-days of data in CHAD after the “flagging” and removal of questionable data. See the text for a discussion of these procedures. Retrospective: a “what did you do yesterday” type of survey; also known as an ex post survey. Diary: a “real-time” paper diary that a subject carried as he or she went through the day. Standard = midnight to midnight. Was activity-specific breathing rate data collected?
Environmental Protection Agency (2004a) consist of one or more days of sequential activities, in which each activity is defined by start time, duration, activity type (140 categories), and microenvironment classification (110 categories). Activities vary from 1 min to 1 h in duration. Activities longer than 1 h are subdivided into clock-hour durations to facilitate exposure modeling. A distribution of values for the ratio of oxygen uptake rate to body mass (referred to as metabolic equivalents or METs) is provided for each activity type listed. The forms and parameters of these distributions were determined through an extensive review of the exercise and nutrition literature. The primary source of distributional data was Ainsworth et al. (1993), a compendium developed specifically to “facilitate the coding of physical activities and to promote comparability across studies.”
Johnson (2001) reviewed the physiological principles incorporated into the algorithms used in pNEM and APEX to convert each activity classification code to an oxygen uptake rate and describes the additional steps required to convert oxygen uptake to VE . McCurdy (1997a,b, 2000) recommended that ventilation rate be estimated as a function of energy expenditure rate. The energy expended by an individual during a particular activity can be expressed as: (AX3-4) AX3-175 where EE is the average energy expenditure rate (kcal/min) during the activity, MET (metabolic equivalent of work) is a ratio specific to the activity and is dimensionless, and RMR is the resting metabolic rate of the individual expressed in terms of number of energy units expended per unit of time (kcal/min). If RMR is specified for an individual, then the above equation requires only an activity-specific estimate of MET to produce an estimate of the energy expenditure rate for a given activity. McCurdy et al. (2000) developed MET distributions for the activity classifications appearing in the CHAD database. An important source of uncertainty in existing exposure modeling involves the creation of multiday, seasonal, or year long exposure activity sequences based on 1- to 3-day activity data
Houston, Los Angeles, Miami, New York, Philadelphia, St. Louis, and Washington): (1) the general population of urban residents, (2) outdoor workers, and (3) children who tended to spend more time outdoors than the average child. Reports by Johnson et al. (1996a,b,c) describe these versions of pNEM/O3 and summarize the results of the application of the model to the nine urban areas. These versions of pNEM/O3 used a revised probabilistic mass balance model to determine O3 concentrations over 1-h periods in indoor and in-vehicle microenvironments (Johnson, 2003). The model assumed that there are no indoor sources of O3, that the outdoor O3 concentration and
ICF Consulting and ManTech Environmental Technology, Inc. (2003) Mentor/SHEDS Probabilistic General population, outdoors, indoors, in-vehicle Employees detailed person oriented exposure approach that includes personal activity data, physiology, and microenvironmental conditions. Allows calculation of exposure and dose for each activity event. Georgopoulos et al. (2005) General population Provides estimates of exposure for 1-day to 3 yrs. Can represent variability in activities of the population to capture extremes in exposure distributions. Lurmann and Colome (1991)
Therefore, O3 monitoring networks should determine the highest concentrations expected to occur in the area, representative concentrations for high population density areas, the impact of sources or source categories on air pollution levels, and general background concentration levels (U.S. Environmental Protection Agency, 1998). The guideline also states that the monitor’s O3 inlet probe should be placed at a height and location that best approximates where people are usually found. However, complicating factors (e.g., security considerations, availability) sometimes result in the probe placement being elevated 3 to 15 m above ground level, a different location than the breathing zone (1 to 2 m) of the populace. Although there are some commonalities in the considerations for the sampling design for monitoring and for determining population exposures, differences also exist. These differences between the location and height of the monitor compared to the locations and breathing zone heights of people can result in different O3 concentrations between what is measured at the monitor and exposure and, therefore, should be considered when using ambient air monitoring data as a surrogate for exposure in epidemiological studies and risk assessments.
Further, since most people spend the majority of their time indoors, where O3 levels tend to be much lower than outdoor ambient levels, the use of ambient monitoring data to determine exposure generally overestimates true personal O3 exposure, resulting in exposure estimates biased towards the null. Information on monitored ambient concentrations of O3 and other photochemical oxidants appears earlier in this chapter. AX3.10.7.3 Ozone Concentrations in Microenvironments The 1996 O3 AQCD for Ozone (U.S. Environmental Protection Agency, 1996a) reported O3 I/O ratios for a variety of indoor environments including homes, office/laboratories, a hospital, museums, a school room, and automobiles and other vehicles. Ozone I/O ratios ranged from 0.09 to 1.0 for residences, 0.19 to 0.8 for offices/laboratories, hospital and school rooms, and 0.03 to 0.87 for museums and art galleries. The higher O3 ratios were generally noted in indoor environments with high AERs or 100% outside air intake. Studies published since completion of the 1996 O3 AQCD are discussed in this section. The findings of the more recent studies on O3 I/O ratios are included in Table AX3-21. Northeast States for Coordinated Air Use Management (NESCAUM, 2002) monitored levels of O3 inside and outside of nine schools located in the New England states. The schools AX3-191 Table AX3-21. Indoor/Outdoor Ozone Ratios AX3-192 Location and Ventilation Conditions Indoor/Outdoor Ratio Mean (range)
Montpellier, France, Homes (110) Reference 0.41 Ozone measurements were made over 5-day periods in and outside of 21 homes during the summer and winter months. The winter I/O ratio was 0.31 compared to 0.46 during the summer months. Bernard et al. (1999)
Southern CA, Homes Upland Mountains 0.68 ± 0.18 (windows open) 0.07 - 0.11 (AC used) Ozone measurements were taken at 119 homes (57 in Upland and 62 in towns located in the mountains) during April and May. I/O ratios were based on average monthly outdoor concentrations and average weekly indoor concentrations. I/O ratio was associated with the home location, number of bedrooms, and the presence of an air conditioner. I/O ratios based on subset of the homes. Geyh et al. (2000); Lee et al. (2002)
Krakow, Poland Museums (5) 0.13 - 0.42 Ozone continuously monitored at five museums and cultural centers. Monitoring conducted during the summer months for 21-46 h or 28-33 days at each of the sites. The I/O was found to be dependent on the ventilation rate, i.e., when the ventilation rate was high, the I/O ratio approached unity, while in rooms sequestered from the outdoor air or where air was predominantly recycled through charcoal filters, the O3 levels indoors were greatly reduced resulting in low I/O ratios. Salmon et al. (2000)
Buildings, Greece Thessaloniki Athens 0.24 ± 0.18 (0.01 to 0.75) There was no heating/air conditioning system in the building at Thessaloniki. Windows were kept closed during the entire monitoring period. Complete air exchange took place every 3 h. I/O ratio ranged from 0.5-0.90, due to low deposition velocity on indoor surfaces. The air conditioning system in continuous use at the Athens site recirculated the air. Complete air exchange was estimated to be 1 h. Monitoring lasted for 30 days at each site, but only the 7 most representative days were used for calculation of the I/O ratio. Drakou et al. (1998) Southern California, Museum 0.19 ± 0.05 Measurements made over a 2-wk period (24-h avg). Ratio for concentrations at the buffer zone with the roll-up door closed. Hisham and Grosjean (1991) AX3-194 Comments
Shields, 1997; Rohr et al., 2002; Nøjgaard et al., 2005). The reactions products of O3 and terpenes are Criegee biradicals, nitrate radicals, and peroxyacyl radicals. Secondary reaction of AX3-212 the pollutants may form hydroxy, alkyl, alkylperoxy, hydroperoxy, and alkoxy radicals. The reaction of O3 with alkenes can produce aldehydes, ketones, and organic acids (Weschler and
PAN and PPN are thermally unstable and will decomposed in the indoor environment to peroxyacetyl radicals and NO2 (See equation AX3-10). Decomposition and formation of PAN in the indoor environment is influenced by NO2 and NO. (AX3-10) When the concentration ratio of NO/NO2 is greater than 7, less than 10% of the peroxyaceyl radicals will revert to PAN. Decomposition of PAN is expected to be a relatively fast process when indoor O3 levels are low and when motor vehicle emissions are large or there is an indoor source of NOx (Weshcler and Shields, 1997). Sources and Emissions of Indoor Ozone Ozone enters the indoor environment primarily through infiltration from outdoors through cracks and crevices in the building envelope (unintentional and uncontrolled ventilation) and through building components such as windows and doors and ventilation systems (natural and controlled ventilation). Natural ventilation is driven by the natural forces of wind and temperature. Possible indoor sources of O3 are office equipment (photocopiers, facsimile machines, and laser printers) and air cleaners (electrostatic air filters and precipitators and O3 generators). Generally O3 emissions from photocopiers and laser printers are limited due to installed filtering systems (Black and Worthan, 1999; Leovic et al., 1996; Aldrich et al., 1995).
Agency, 2002). Peroxyacyl nitrates (PAN and PPN) have no known direct emission sources and are formed in the atmosphere from the reaction of NO2 and hydrocarbons (Grosjean et al., 1996). Peroxyacyl nitrates primarily occur in the indoor environment from infiltration through the building envelop and through openings in the building envelopment. Peroxyacyl nitrates also may be formed in the indoor environment through radical chemistry. PAN may be formed from the reaction of the OH@ or NO3 with acetaldehyde to form the acetyl radical, CH3CO. The acetyl radical then reacts with oxygen to form and acetylperoxy radical which reacts with NO2 to form
NO/NO2 concentration ratio (Grosjean et al., 2001). Other free radicals that can form indoors include HOC and HO2C. These free radicals can produce compounds that are known or suspected to be irritating. Little is known about exposure to some of these agents, as not all have been identified and collection and analytical methodologies have not be developed for their routine determination. Lee et al. (1999) reported that homogeneous (gas phase) and heterogenous (gas phase/solid surface) reactions occur between O3 and common indoor air pollutants such as NO and VOCs to produce secondary products whose production rate depends on the AER and surface area within the home. Wainman et al. (2000) found that O3 reacts indoors with d-limonene, emitted from air fresheners, to form fine particles in the range of 0.1 to 0.2 µm and 0.2 to 0.3 µm. The indoor process also produces compounds that have been identified in the ambient atmosphere. These species, plus others that may form indoors from other terpenes or unsaturated compounds can present an additional exposure to oxidants, other than O3, at higher concentrations than present in ambient air, even as the O3 concentration is being reduced indoors. The announcement of smog alerts or air quality indices may influence individuals to alter behaviors (avoidance behavior).
Neidell (2004), in his evaluation of the effect of pollution on childhood asthma, examined the relationship between the issuance of smog alerts or air quality indices for several counties in California and hospital admissions for asthma in children under
Environmental Protection Agency, 1996b). There are three versions of the pNEM/O3 model: general population (Johnson et al., 1996a), outdoor workers (Johnson et al., 1996b), and outdoor children (Johnson et al., 1996c, 1997). These three versions of the model have been applied to nine urban areas. The model also has been applied to a single summer camp (Johnson et al., 1996c). The general population version of the model uses activity data from the Cincinnati Activity Diary Study (CADS;
Johnson, 1989). Time-activity studies (Wiley et al., 1991a; Johnson, 1984; Linn et al., 1993; Shamoo et al., 1991; Goldstein et al., 1992; Hartwell et al., 1984) were combined with the CADS data for the outdoor worker version of the model. Additional time-activity data (Goldstein et al., 1992; Hartwell et al., 1984; Wiley et al., 1991a,b; Linn et al., 1992; Spier et al., 1992) were also added to CADS for the outdoor children of the model (U.S. Environmental Protection Agency, 1996b). Home-work commuting patterns are based on information gathered by the U.S. Census Bureau. Ozone ambient air concentration data from monitoring stations were used to estimate the outdoor exposure concentrations associated with each exposure event. Indoor O3 decay rate is assumed to be proportional to the indoor O3 concentration. An algorithm assigns the equivalent ventilation rate (EVR) associated with each exposure event. The outdoor children model uses an EVR-generator module to generate an EVR value for each exposure event based on data on heart rate by Spier et al. (1992) and Linn et al. (1992). The models produce exposure AX3-221 estimates for a range of O3 concentrations at specified exertion levels. The models were used to estimate exposure for nine air quality scenarios (U.S. Environmental Protection Agency, 1996b).
Korc (1996) used the REHEX-II model, a general purpose air pollution exposure model based on a microenvironmental approach modified to account for the influence of physical activity along and spatial and the temporal variability of outdoor air pollution. Ozone exposure
A. (1989) A reassessment of the economic effects of ozone on U.S. agriculture. JAPCA 39: 960-968. Ainsworth; Haskell, W. L.; Leon, A. S.; Jacobs, D. R., Jr.; Montoye, H. J.; Sallis, J. F.; Paffenbarger, R. S., Jr. (1993) Compendium of physical activities: classification of energy costs of human physical activities. Med. Sci. Sports Exer. 25: 71-80.
W. (1985) Measuring human exposure to carbon monoxide in Washington, D.C., and Denver, Colorado, during the winter of 1982-1983. Environ. Sci. Technol. 19: 911-918.
M. (1995) Health and productivity impact of organic volatiles from electronic office equipment. Presented at: Pacific Rim conference on occupational and environmental health; October; Sydney, Australia.
D. (1978) Characterization of potential indoor sources of ozone. Am. Ind. Hyg. Assoc. J. 39: 466-471.
Aneja, V. P.; Li, Z. (1992) Characterization of ozone at high elevation in the eastern United States: trends, seasonal variations, and exposure. J. Geophys. Res. [Atmos.] 97: 9873-9888.
D. (1998a) Modeling ozone levels in and around southern California homes. Environ. Sci. Technol. 32: 463-468.
M. (1998b) Acute effects of ambient ozone on asthmatic, wheezy, and healthy children. Cambridge, MA: Health Effects Institute; research report no. 82.
Beine, H. J.; Jaffe, D. A.; Herring, J. A.; Kelley, J. A.; Krognes, T.; Stordal, F. (1997) High-latitude springtime photochemistry. Part I: NOx, PAN and ozone relationships. J. Atmos. Chem. 27: 127-153.
R. (1964) Differences in concentrations of surface oxidant between valley and mountaintop conditions in the southern Appalachians. J. Air Pollut. Control Assoc. 14: 238-239.
G. (2001a) Global modeling of tropospheric chemistry with assimilated meteorology: model description and evaluation. J. Geophys. Res. (Atmos.) 106: 23,073-23,095.
M. (2001b) Asian chemical outflow to the Pacific in spring: origins, pathways, and budgets. J. Geophys. Res. [Atmos.] 106: 23,097-23,113.
C. (1981) A general model for estimating exposure associated with alternative NAAQS. Presented at: 74th annual meeting of the Air Pollution Control Association; June; Philadelphia, PA. Pittsburgh, PA: Air Pollution Control Association; paper no. 81-18.4.
Billick, I.; Johnson, D.; Moschandreas, D.; Relwani, S. (1984) An investigation of operational factors that influence emission rates from gas appliances. In: Berglund, B.; Lindvall, T.; Sundell, J., eds. Indoor air. Volume 4: chemical characterization and personal exposure. Proceedings of the 3rd international conference on indoor air quality and climate; August; Stockholm, Sweden. Stockholm, Sweden: Swedish Council for Building Research; pp. 181-187. AX3-223
Billick, I. H.; Behrens, D. W.; Becker, E. W.; Garrison, C. A.; Wilson, A. L.; Colome, S. D.; Tian, Y. (1996) California residential indoor air quality study: an overview. In: Proceedings of the 1995 international gas research conference; November 1995; Cannes, France. Rockville, MD: Government Institutes, Inc.; pp. 1707-1716.
W. (1999) Emissions from office equipment. In: Raw, G.; Aizlewood, C.; Warren, P., eds. Indoor Air '99, v. 2. London, England: Construction Research Communications Ltd.; pp. 454-459.
J. (2003) Differences between weekday and weekend air pollutant levels in southern California. J. Air Waste Mange. Assoc. 53: 816-828.
Blondeau, P.; Iordache, V.; Poupard, O.; Genin, D.; Allard, F. (2005) Relationship between outdoor and indoor air quality in eight French schools. Indoor Air 15: 2-12. Böhm, M.; McCune, B.; Vandetta, T. (1991) Diurnal curves of troposheric ozone in the western United States. Atmos. Environ. Part A 25: 1577-1590.
B. (1990) Depletion of lower tropospheric ozone during Arctic spring: The Polar Sunrise Experiment 1988. J. Geophys. Res. (Atmos.) 95: 18,555-18,568.
Bottenheim, J. W.; Barrie, L. A.; Atlas, E. (1993) The partitioning of nitrogen oxides in the lower Arctic troposphere during Spring 1988. J. Atmos. Chem. 17: 15-27.
L. (2003) Ozone, aerosol, potential vorticity, and trace gas trends observed at high-latitudes over North America from February to May 2000. J. Geophys. Res. [Atmos.] 108(D4): 10.1029/2001JD001390.