EPA. An exposure assessment of polybrominated diphenyl ethers. National Center for Environmental Assessment, Washington, DC; EPA-600-R-08-086F. May 2010
Other documents for the same rulemaking (all, by stage)
References
CARB (2005) 8, 23 Median, mean (n = 9) from vacuum samples in
Dallas, TX in 2004 Schecter et al. (2005) HexaBDE 4-15 Table 4-1. Congener specific concentrations of PBDEs in house dust in the United States (units in ng/g dwt) (continued) Congener Concentration (ng/g dwt) Comment Reference 20.9, 12.1, 5.2 Geometric mean of 3 locations/home from 20 homes in Boston, MA area; living room, bedroom, and vacuum Allen et al. (2008)
ND, 77 Median, ng/g, from 11 homes in the Boston, MA area Wu et al. (2007) 2.28, <0.04
Mean, median from 12 homes in Albany, NY JohnsonRestrepo and Kannan (2009) Mean 17 homes, Washington DC Stapleton et al. (2005) Mean 10 homes throughout U.S., but 7 ND, 1 at 1,510 Sharp and Lunder (2004) 140 (5−650) Median; range from 10 homes in Atlanta Sjodin et al. (2008) Carpet dust (n = 2) from computer labs in CA
CARB (2005) 61, 199 Median, mean (n = 9) from vacuum samples in
Dallas, TX in 2004 Schecter et al. (2005) 234.4, 124.2, 47.0 Geometric mean of 3 locations/home from 20 homes in Boston, MA area; living room, bedroom, and vacuum Allen et al. (2008) 107, 563
MA area Wu et al. (2007) 240, 120 Mean, geometric mean from homes in Amarillo/Austin, Texas from 2006 (n = 20) Harrad et al. (2008b) 30.2, 25.9
Mean, median from 12 homes in Albany, NY JohnsonRestrepo and Kannan (2009) Mean 17 homes, Washington DC Stapleton et al. (2005) Mean 10 homes throughout U.S., but 8 ND, 1 at 1,050 Sharp and Lunder (2004) 80 (<4−260) Median; range from 10 homes in Atlanta Sjodin et al. (2008) Carpet dust (n = 2) from computer labs in CA
CARB (2005) 54, 189 Median, mean (n = 9) from vacuum samples in
Dallas, TX in 2004 Schecter et al. (2005) 4-16 Table 4-1. Congener specific concentrations of PBDEs in house dust in the United States (units in ng/g dwt) (continued) Congener Concentration (ng/g dwt) Comment Reference 182.8, 94.4, 35.0 Geometric mean of 3 locations/home from 20 homes in Boston, MA area; living room, bedroom, and vacuum Allen et al. (2008) 93, 455
Median, ng/g, from 11 homes in the Boston, MA area Wu et al. (2007) 240, 100
Mean, geometric mean from homes in Amarillo/Austin, Texas from 2006 (n = 20) Harrad et al. (2008b) 17.4, 9.6
CARB (2005) Mean 17 homes, Washington DC Stapleton et al. (2005) Carpet dust (n = 2) from computer labs in CA
CARB (2005) Mean 17 homes, Washington DC Stapleton et al. (2005) Mean 10 homes throughout United States, but 9
ND, 1 at 604 Sharp and Lunder (2004) 70 (<4−4,000) Median; range from 10 homes in Atlanta Sjodin et al. (2004) Carpet dust (n = 2) from computer labs in CA
CARB (2005) 18.6, 19.3 Median, mean (n = 9) from vacuum samples in
Dallas, TX in 2004 Schecter et al. (2005) 27.9, 32.9, 15.1 Geometric mean of 3 locations/home from 20 homes in Boston, MA area; living room, bedroom, and vacuum Allen et al. (2008) 28, 16
Mean, geometric mean from homes in Amarillo/Austin, Texas from 2006 (n = 17) Harrad et al. (2008b) 18, <21
Mean, median from 12 homes in Albany, NY JohnsonRestrepo and Kannan (2009) Mean 17 homes, Washington DC Stapleton et al. (2005) HeptaBDE 4-17 Table 4-1. Congener specific concentrations of PBDEs in house dust in the United States (units in ng/g dwt) (continued) Congener Concentration (ng/g dwt) Mean 17 homes, Washington DC Stapleton et al. (2005) Carpet dust (n = 2) from computer labs in CA
CARB (2005) Mean 17 homes, Washington DC Stapleton et al. (2005) Mean 17 homes, Washington DC Stapleton et al. (2005) 3.6, 2.6, 3.9 Geometric mean of 3 locations/home from 20 homes in Boston, MA area; living room, bedroom, and vacuum Allen et al. (2008) Mean 17 homes, Washington DC Stapleton et al. (2005) 2.7, 3.3, 5.6 Geometric mean of 3 locations/home from 20 homes in Boston, MA area; living room, bedroom, and vacuum Allen et al. (2008) Carpet dust (n = 2) from computer labs in CA
CARB (2005) 3.6, 3.6, 4.9 Geometric mean of 3 locations/home from 20 homes in Boston, MA area; living room, bedroom, and vacuum Allen et al. (2008) <3, <3
Mean, median from 12 homes in Albany, NY JohnsonRestrepo and Kannan (2009) Mean 17 homes, Washington DC Stapleton et al. (2005) 76.3, 48.1, 40.5 Geometric mean of 3 locations/home from 20 homes in Boston, MA area; living room, bedroom, and vacuum Allen et al. (2008) Mean 17 homes, Washington DC Stapleton et al. (2005) 45.9, 25.3, 26.6 Geometric mean of 3 locations/home from 20 homes in Boston, MA area; living room, bedroom, and vacuum Allen et al. (2008) Comment Reference OctaBDE NonaBDE 4-18 Table 4-1. Congener specific concentrations of PBDEs in house dust in the United States (units in ng/g dwt) (continued) Congener Concentration (ng/g dwt) Comment Reference <0.1, <0.1
Mean, median from 12 homes in Albany, NY JohnsonRestrepo and Kannan (2009) Mean 17 homes, Washington DC Stapleton et al. (2005) 35.6, 17.5, 29.4 Geometric mean of 3 locations/home from 20 homes in Boston, MA area; living room, bedroom, and vacuum Allen et al. (2008) 2,090 Mean 17 homes, Washington DC Stapleton et al. (2005) 2,394 Mean 10 homes throughout United States Sharp and Lunder (2004) 2000 (120−21,000) Median; range from 10 homes in Atlanta Sjodin et al. (2008) 7500 Carpet dust (n = 2) from computer labs in CA
CARB (2005) 665, 8,567 Median, mean (n = 9) from vacuum samples in
Dallas, TX in 2004 Schecter et al. (2005) 4,502, 1,703, 1,811 Geometric mean of 3 locations/home from 20 homes in Boston, MA area; living room, bedroom, and vacuum Allen et al. (2008)
ND, 9,020 Median, ng/g, from 11 homes in the Boston, MA area Wu et al. (2007) 1,600, 1,300
Mean, geometric mean from homes in Amarillo/Austin, Texas from 2006 (n = 17) Harrad et al. (2008b) 2,810, 903
Mean, median from 12 homes in Albany, NY JohnsonRestrepo and Kannan (2009) DecaBDE samples with the highest concentration had the commercial pentaBDE commercial ration of 0.6 for BDE 47/BDE 99. Clothes dryer lint was studied from U.S. and German sources (Schecter et al., 2009b). Dryer lint from 12 U.S. and 7 German homes were analyzed for 13 congeners: BDE 17, BDE 28,
GA, Germany, Australia, and the United Kingdom (Sjodin et al., 2008; first partially reported in Sjodin et al., 2004) for a total of 40 samples. These samples were analyzed for BDE 47,
BDE 99 is similar in concentration to that of BDE 47. This contention is different from those made by others, who note that the ratio of BDE 47 to BDE 99 in commercial penta formulations is about 0.60. Wenning et al. (2006) collected vacuum bag dust and air conditioner filter dust from homes in Northern California and Wellington, New Zealand, but the average congener-specific concentrations they presented were for all samples, not distinguishing between geography or whether it was vacuum or air conditioner-generated dust. The average total BDE concentration over 13 samples, including 10 vacuum and 3 air conditioner samples, was 13,570 ng/g dwt, with
BDE 209 comprising 9,052 ng/g dwt, and BDE 99 and BDE 47 comprising 2,140 and 1,120 ng/g dwt, respectively. The BDE 209 results were skewed by a business air conditioner filter showing 84,500 ng/g dwt, from a total of 96,300 ng/g dwt, so the general representativeness of these samples must be questioned. Indoor air and dust were sampled in 120 homes in Cape Cod, MA, in two rounds of 60 samples each starting in 99 and ending in 2001 (Rudel et al., 2003). A total of 89 homes were sampled for PBDEs in dust, Only three BDEs (BDE 47, BDE 99, and BDE 100) were analyzed, and the reporting limits were high―400 ng/g dwt for BDE 47 and BDE 99 and 300 ng/g dwt for
BDE 100. Because of this, the data had limited value. BDE 47 was found in about 50% of the samples with a maximum of 9,860 ng/g dwt; BDE 99 was found also about 50% of the time with a maximum of 22,500 ng/g dwt; and BDE 100 was found 20% of the time with a maximum of 3,400 ng/g dwt. Johnson-Restrepo and Kannan (2009) collected dust samples from the vacuum bags of residents of 12 homes in Albany, NY, between December 2007 and January 2008. Twenty congeners from BDE 28 to BDE 209 were measured in the dust. BDE 209 was the major congener found, accounting for between 26 and 99% of the total concentration. The mean of the 12 samples was 3,190 ng/g, the median was 1,910 ng/g, and the range was 380 to 9,340 ng/g. Four computer wipe and nine vacuum bag bulk dust samples were taken in Dallas, Texas in 2004 (Schecter et al., 2005; date of sampling not given but presumed to be in 2004 as paper was submitted in July 2004). The computer wipe samples were in units of ng/100 cm2, and 4-21 because no other data were available with which to compare these units, results from this study are not provided in Table 4-1. Briefly, concentrations ranged from 77 to 1,536 ng/100 cm2, with
BDE 209 was the prominent congener in seven of nine samples (BDE 99 was the dominant in the other two samples), explaining 95% of the concentration in the highest sample (65,777 ng/g dwt of 69,283 ng/g dwt total) and 66−87% in the other samples. In one sample, however, BDE 209 explained less than 1% of the 30,368 ng/g dwt total, with BDE 99 explaining 13,841 (46%) and BDE 47 explaining 10,538 ng/g dwt (35%). Allen et al. (2008) reports on BDEs in house dust samples that were part of a study looking at the correlations between indoor air and bulk dust samples in 20 homes in the urban setting of Boston, MA. They took three bulk samples out of each home and developed geometric mean congener-specific concentrations for the three common locations: the main living room, the bedroom, and a sample from a home vacuum (location undetermined). Like other studies,
BDE 154), but did not find a correlation between BDE 209 air and dust concentrations. Their highest concentration of 544,000 ng/g dwt was dominated by BDE 209, at 527,000 ng/g dwt. In another study of the Boston, MA, area, Wu et al. (2007) sampled 11 houses and measured for BDE 17, BDE 28/33, BDE 47, BDE 66, BDE 85, BDE 99, BDE 100, BDE 138,
BDE 153, BDE 154, BDE 183, and BDE 209. This was a study in which women’s breast milk in these homes were also sampled (results reported in Chapter 5). Results were log normal, with a geometric mean of total BDE concentration of 1,910 ng/g dwt. BDE 99 and BDE 47 were 4-22 quantified in nearly all samples, with median concentrations of 1,010 and 670 ng/g dwt, respectively. BDE 209 was quantified in 5 of 11 samples, with quantified concentrations ranging between 1,360 and 9,020 ng/g dwt. The median total concentration was 1,910 ng/g dwt. They found a correlation of r = 0.76 (p = 0.003) between concentrations of pentaBDE congeners in the breast milk of first time mothers and dust sampled from their homes. There was also a statistically significant correlation between dust levels and with reported dietary habits, particularly the consumption of dairy products. Harrad et al. (2008b) sampled between 10 and 28 homes in each of these locations: Amarillo/Austin in Texas; Birmingham, UK; Toronto, Canada; and Wellington, New Zealand. They measured BDE 28, BDE 47, BDE 99, BDE 100, BDE 153, BDE 154, BDE 183, and
Texas, which have an average of 1,600, a median of 1,300, and a geometric mean of 1,300 ng/g dwt (n = 17). The two highest concentrations of BDE 209 were found in homes in the United Kingdom, at 520,000 and 100,000 ng/g dwt (Harrad et al., 2008b). The concentrations of the tri-hexa congeners (BDE 28 through BDE 154) were the highest for the Texas dust. For example, the geometric mean for the sum of these six congeners from the Texas sites was 1,800 compared to 52 from the UK sites. Due to the high BDE 209 findings, the overall total concentrations were highest for the United Kingdom, similar to the findings of Sjodin et al. (2008). The geometric mean total concentrations for the United Kingdom, United
States, and Canadian sites were 4,500, 3,600, and 1,200 ng/g dwt. Totals were not provided for New Zealand because the BDE 183 and BDE 209 congeners were not measured. Concentrations of the tri-hexa congeners totaled 92 ng/g dwt, which was comparable to the tri-hexa totals for the United Kingdom. Zota et al. (2008) took dust samples in 49 homes in Northern California and measured them for BDEs 47, 99, and 100. Median and range of concentrations were (in ng/g dwt):
BDE 47―3,750 and 11−107,000; BDE 99―3,830 and 102−170,000; and BDE 100―756 and <MRL―30,900. As Zota et al. (2008) notes, these concentrations were 4−10 times higher than concentrations found for these congeners in U.S. studies summarized here (Rudel et al., 2003; Wu et al., 2007; Stapleton et al., 2005; Harrad et al., 2008b) and orders of magnitude higher than 4-23 studies abroad. The authors also identified blood samples from NHANES 2001/2002 that were from California and compared them to the entire NHANES 2001/2002 statistical extrapolations for the United States. Their geometric mean for the sum of six congeners (BDE 28, BDE 47,
BDE 99, BDE 100, BDE 153, and BDE 154) from samples in California was 62 ng/g lipid weight (lwt), while the total for all of the United States was 38.6 ng/g lwt. They suggest this might have resulted from more stringent standards for flammability in California as compared to other states. The NHANES database is discussed further in Chapter 5. Hwang et al. (2008) measured seven congeners (BDE 47, BDE 66, BDE 99, BDE 100,
BDE 138, BDE 153, and BDE 154) in dust collected from vacuum bags provided by residents in 10 apartments and 1 community hall in Davis, California. They found that the total ranged from 1,780−25,500 ng/g dwt, with a median of 9,240 ng/g dwt. Median and range of the three dominant congeners were (in ng/g dwt) BDE 47―2,920 and 655−8,830; BDE 99―4,430 and 807−11,700; and BDE 100―793 and 165−2,000. The California Air Resources Board (CARB) has conducted a substantial amount of sampling for brominated flame retardants in air and dust, both outside near industrial sites and in urban and background locations, and inside at workplaces and industrial sites. 1 Two samples of carpet dust in an indoor computer training facility totaled 10,200 and 4,800 ng/g dwt (CARB, 2005). Congeners in the dust that were not in the air that was sampled in this facility included
BDE 77, BDE 138, BDE 155, BDE 183, and BDE 203 (BDE 203 and BDE 183 are congeners in the octa formulation). The dominant congener was BDE 209, at 7,560 and 2,800 ng/g dwt, followed by BDE 99 at 856 and 695 ng/g dwt, and BDE 47 at 502 and 411 ng/g dwt. Wilford et al. (2005) studied house dust concentrations from 68 of 74 homes in Canada that previously had been studied for air concentrations of PBDEs (see Section 4.5) in the winter of 2002/2003. They found that the data were log normally distributed, with a geometric mean of 2,000 ng/g, a median of 1,800 ng/g, and an arithmetic mean of 5,500 ng/g. For the arithmetic mean, BDE 209 comprised 1,000 ng/g of the total, or 18%, while for the median, BDE 209 comprised half, at 900 ng/g. This suggests that BDE 209 dominates the highest concentrations found. After BDE 209 for the mean, the highest concentrations were BDE 99 at 1,800 ng/g and
BDE 47 at 1,100 ng/g, with other concentrations less than 500 ng/g. See http://www.arb.ca.gov/toxics/pbde.htm. 4-24 Sampling of house dust has also occurred in foreign countries, including Europe and Kuwait. Fabrellas et al. (2005) report sampling done by “Euroconsumers Organization” and “CIEMAT-POPs Group,” in which dust was collected from 100 vacuum cleaner bags from Spain (34 bags), Belgium (32 bags), Portugal (22 bags), and Italy (12 bags) and measured for BDEs. Homologue group concentrations from mono- to heptaBDE were determined; levels of detections ranged from 0.006−0.220 ng/g dwt (BDE 3) to 0.55−20.9 ng/g dwt (for BDE 209). Results suggest Italy has the highest total concentrations, at 581 ng/g dwt, followed by Portugal (354 ng/g dwt), Spain (238 ng/g dwt), and Belgium (190 ng/g dwt). However, it is unknown if these mean values are significantly different. The highest value from Spain was from a dust sample that had been sucked out from the inside of a computer. Urban house dust samples were found to be higher than rural, and BDE 209 was found to comprise greater than 60% of total
PBDE in all cases. The ratio of BDE 47 to BDE 99, which is 0.5−0.7 in 24% of the samples, is the same as the commercial penta formulation, DE-71, which has a ratio of 0.6, suggesting these samples were dominated by this commercial mixture. Harrad et al. (2006) measured BDEs in house dust at eight homes sampled in 2005 in the United Kingdom. They reported an average of 215 ng/g total (maximum of 625 ng/g total), which included BDE 28, BDE 47, BDE 49, BDE 66, BDE 85, BDE 99, BDE 100, BDE 153, and
BDE 154 (BDE 209 not measured). The ratio of BDE 47 to BDE 99 was about 0.5. The study that Harrad et al. (2008b) later published on different locations around the world (United
Kingdom, United States, New Zealand, and Canada) included these earlier data. Harrad et al. (2008a) later measured dust samples taken from cars, homes, and offices in locations in southern United Kingdom (West Midlands area), and found the highest BDE 209 measurements in dust samples that have been found as of the date of this report, including findings of 2,200,000 ng/g in a home and 2,600,000 ng/g dwt in a car (further discussion on the car data provided in Section 4.4.2 below). The average total BDE concentration (sum of
BDE 209 overwhelmed the average. The average of 18 office samples was 31,000 ng/g dwt total, with BDE 209 explaining 30,000 ng/g dwt of that average. They went back to sample one 4-25 of the two homes with high BDE 209, 1,400,000 ng/g dwt, and found a similar concentration: 900,000 ng/g dwt Karlsson et al. (2007) report on measurements of PBDEs in air, house dust, and blood from five households in Sweden. The average total BDE (including 13 BDEs) was about 690 ng/g dwt, dominated by BDE 209 that was 490 ng/g dwt, followed by BDE 99 and BDE 47, at 99 ng/g dwt and 51 ng/g dwt, respectively. Gevao et al. (2005) report on simultaneous air and dust from homes in Kuwait in 2005. PUF samplers were used to measure air samples, and bulk dust samples were obtained from vacuum bags in 17 homes in Kuwait between 2/29/2004 and 4/11/2004. Individual congeners measured included BDEs 28, BDE 47, BDE 100, BDE 99,
BDE 99 seemed to track well with what the authors claimed was a commercial penta mixture; however, the 47/99 ratio of this mixture was not 0.6 but rather close to 1.0. House dust correlated with indoor air―when one was high, the other was also. Recent data from Europe show very high levels of BDE 209. House dust and lint samples were collected in Scotland, Northern England, and Germany (Pless-Mulloli et al., 2006) and compared with other published data from the United States, although the comparison did not include more recent data such as those from Allen et al. (2008). The United Kingdom had the highest concentrations, though they were dominated by BDE 209, while Germany’s concentrations were much lower. The United Kingdom dust samples had a mean of 11,325 ng/g, a median of 3,933 ng/g, and a maximum of 54,858 ng/g. The UK samples were dominated by
BDE 209, which had an average concentration of 11,233 ng/g (of the 11,325 ng/g total). The median of U.S. dust measurements were similar to the median of the United Kingdom’s measurements at 4,200 ng/g, but BDE 209 was not nearly as dominant, having a median of only 2,000 ng/g. As discussed earlier, the data in Allen et al. (2008) from homes in the Boston, MA area have higher BDE 209 concentrations than the measurements summarized in Pless-Mulloli et al. (2006). In summary, the most common indoor congeners include those associated with the penta formulations, BDE 47 and BDE 99, and the single congener most associated with the deca formulation, BDE 209. Concentrations of total BDEs ranged from the low 100s to well over 4-26 10,000 ng/g dwt. Concentrations of BDE 209 have been found in the hundreds of thousands to over two million of ng/g dwt in the United Kingdom (Harrad et al., 2008a) and in the hundreds of thousands in one study in the U.S. (from Allen et al., 2008). Most authors reported that the results suggested the presence of the penta formulation, based on the ratio of the two congeners,
BDE 153, and BDE 154, as compared to offices and homes. They went back to sample the high car finding of BDE 209, 2,600,000 ng/g dwt, and found a similar concentration: 2,200,000 ng/g dwt. 4-27 Lagalante et al. (2009) sampled dust within 60 cars in the United States and, like Harrad et al. (2008a), found a dominance of BDE 209. The cars were manufactured mostly in the 2000s; one car each was manufactured in 1990, 1998, and 1999. The median BDE 209 level was 48,100 ng/g dwt, and it comprised 95% of total BDEs measured. Median concentrations of the other congeners measured were BDE 28―118 ng/g dwt, BDE 47―880 ng/g dwt,
Network, composed of 11 sites, began sampling in 2002, and the data for the years 2002−2004 are posted at http://www.arb.ca.gov/pub/dioxin/cadamp.php. PBDE data were taken from 7 of these 11 sites, 4 from the Bay Area and 3 from the South Coast, beginning in 2003. There were 6 monthly samples in 2003 and 12 monthly samples in 2004. Individual site data and 4-29 Table 4-2. Outdoor and indoor congener-specific air concentrations of PBDEs in the United States (units in pg/m3) Congener Concentration (pg/m3) Comment Citation Outdoors at UC Davis, 2004; average of 2 days of filter/PUF and filter/XAD samplers