Source Test Report: Novelis Inc., New York.
Other documents for the same rulemaking (all, by stage)
References: 2 extracted, 0 linked to papers
NOVELIS SOURCE TEST REPORT- APRIL 2011 Eq. 7c yields; L cPM = 6.3.2 (L MT − PM + L IF − PM ) = (0 . 4 lb / ton + 0 . 01 lb / ton ) = 0 . 205 lb / ton Hydrogen Chloride (HCl) Equipment specific emission limits: Equipment Emission Limit Reference Group 1 Melting/Holding Furnace (Clean and Non-Clean Charge) 0.40 lb/ton 40 CFR 63.1505(i)(4) In-Line Fluxer 0.04 lb/ton 40 CFR 63.1505(j)(1) Eq. 7c yields; L cHCl = 6.3.3 (L MT − HCl + L IF − HCl ) = (0 . 4 lb / ton + 0 . 04 lb / ton ) = 0 . 220 lb / ton Dioxins/Furans (D/F) Equipment specific emission limits: Equipment Group 1 Melting/Holding Furnace (Clean and Non-Clean Charge) Emission Limit Reference 2.10 X 10-4 gr TEQ/ton 40 CFR 63.1505(i)(3) none none In-Line Fluxer Eq. 7f yields; L cD / F = L MT = 2 . 10 X 10 − 4 grTEQ / ton
NOVELIS SOURCE TEST REPORT- APRIL 2011 DC7 PROCESS-COMBINED EMISSION CALCULATIONS FOR SAPU To calculate the combined emissions from 720MT/720IF and 760MT/760IF the same approach is followed as presented above in Section 6.3 for the emission limits. This same approach is utilized to provide an accurate comparison of the measured total emissions to the calculated SMACT limits. Since the furnace and in-line fluxer both exhaust from the same emission point for 720 and 760 (i.e. EP 720 and EP 760), the test results from each source yield emission rates that are representative of the combined emissions from the furnace and in-line fluxer. As