Revised Requirements for Designation of Reference and Equivalent Methods for PMINF2.5/INF and Ambient Air Quality Surveillance for Particulate Matter
Federal Register1997-07-18 · ENVIRONMENTAL PROTECTION AGENCY · Rule · 97-18579
Final rule.
This final rule revises the 40 CFR part 58 ambient air quality surveillance regulations to include provisions for PM<INF>2.5</INF> (particulate matter with an aerodynamic diameter less than or equal to a nominal 2.5 micrometers), as measured by a new reference method being published in 40 CFR part 50, Appendix L, elsewhere in this issue of the Federal Register or by an equivalent method designed in accordance with requirements being promulgated in 40 CFR part 53. In addition, this rule also revises existing ambient air quality monitoring requirements for PM<INF>10</INF> (particles with an aerodynamic diameter less than or equal to 10 micrometers). These revisions address network design and siting, quality assurance (QA) and quality control (QC), operating schedule, network completion, system modifications, data reporting, and other monitoring subjects.
Original sourceWeb page (668 KB)PDF (1.1 MB)
RIN 2060-AE66
Other documents for the same rulemaking
References: 9 extracted, 2 linked to papers
Page 1Download these results: CSV · JSON
Brenda Millar (MD-14), Monitoring and Quality Assurance Group
otherNot linked to a paper · FOR FURTHER INFORMATION CONTACT
Vanderpool and Rubow (1988) (Reference 2 in Appendix A of this subpart)
otherNot linked to a paper · Sec. 53.61(g)(2)
Marple, V.A., K.L. Rubow, W. Turner, and J.D. Spangler, Low Flow Rate Sharp Cut Impactors for Indoor Air Sampling: Design and Calibration., JAPCA, 37: 1303-1307 (1987).
Vanderpool, R.W. and K.L. Rubow, Generation of Large, Solid Calibration Aerosols, J. of Aer. Sci. and Tech., 9:65-69 (1988).
Guidelines for preparation of fluorescein solutions of the desired volume concentration (Cvol) are presented by Vanderpool and Rubow (1988) (Reference 2 in Appendix A of this subpart).
Rhodes, R.C. Guideline on the Meaning and Use of Precision and Accuracy Data Required by 40 CFR part 58, Appendices A and B. EPA-600/4-83/023.
research reportNot linked to a paper · Appendix A to Part 58, References
Musick, D.R. The Ambient Air Precision and Accuracy Program: 1995 Annual Report. EPA-454/R97001.
research reportNot linked to a paper · Appendix A to Part 58, References (13)
Eldred, R.A., Cahill, T.A., Wilkenson, L.K., et al., Measurements of fine particles and their chemical components in the IMPROVE/NPS networks, in Transactions of the International Specialty Conference on Visibility and Fine Particles, Air and Waste Management Association: Pittsburgh, PA, 1990; pp 187-196.
conference paperNot linked to a paper · Appendix C to Part 58, Section 6.0 References (4)
Sisler, J.F., Huffman, D., and Latimer, D.A.; Spatial and temporal patterns and the chemical composition of the haze in the United States: An analysis of data from the IMPROVE network, 1988-1991, ISSN No. 0737-5253-26, National Park Service, Ft. Collins, CO, 1993.
research reportNot linked to a paper · Appendix C to Part 58, Section 6.0 References (5)
Eldred, R.A., Cahill, T.A., Pitchford, M., and Malm, W.C.; IMPROVE--a new remote area particulate monitoring system for visibility studies, Proceedings of the 81st Annual Meeting of the Air Pollution Control Association, Dallas, Paper 88-54.3, 1988.
conference paperNot linked to a paper · Appendix C to Part 58, Section 6.0 References (6)