ERG Silica_GenInd 1v.2, 2008. Technological Feasibility Study of Regulatory Alternatives for a Proposed Crystalline Silica Standard for General Industry, Volume 1. August 2008 draft (version 2)
Other documents for the same rulemaking
References: 253 extracted, 4 linked to papers
Croteau, Gerry. 2000. The effect of local exhaust ventilation controls on dust exposures during masonry activities. Thesis in partial fulfillment of MS degree, University of Washington, Dept. of Enviromental Health.
Eppler, Doug. 2001. Personal communication between Doug Eppler and Eastern Research Group, Inc. (February 8).
Ewsuk, K.G. 1992. Ceramics. In: Kirk-Othmer Encyclopedia of Chemical Technology, Vol. 5, 4th ed. New
York, NY: John Wiley & Sons, Inc. pp. 599-633. 4-32 August 2008 Draft Do Not Cite or Quote
Hall, R.M, W.A. Heitbrink, and L.D. Reed. 2002. Evaluation of a tractor cab using real-time aerosol counting instrumentation. Applied Occupational and Environmental Hygiene, 17(1):47-54. January.
Haney. 2000. Haney, R. Presentation at Triagency Workshop - Measurement and Control of Silica. (June 28).
NIOSH. 2001. In-depth survey report: Control technology for environmental enclosures B an evaluation of in-use enclosures at John Deere Product Engineering Center, Waterloo, Iowa (EPHB 223-05i). National Institute for Occupational Safety and Health, Cincinnati, Ohio. July.
NIOSH. 1995. In-depth survey report: a laboratory comparison of conventional drywall sanding techniques versus commercially available control. ECTB 208-11a. National Institute for Occupational Safety and Health, Cincinnati, Ohio.
NIOSH CT 171-11c. 1992. SENSOR: Follow-Up Study for Control of Silica Exposure at Woodbridge Sanitary Pottery Corp., Woodbridge, NJ. CT-171-11c. Cincinnati, OH: National Institute for Occupational Safety and Health. (February).
NIOSH ECTB 171-11b. 1989. SENSOR: Recommendations for Control of Silica Exposure at Woodbridge Sanitary Pottery Corp., Woodbridge, NJ. CT-171-11b. Cincinnati, OH: National Institute for Occupational Safety and Health. (June).
NIOSH CT-110-11a. 1981. Preliminary Survey Report, The Hall China Co., East Liverpool, OH.
NIOSH HETA 84-0066-1883. 1988. Health Hazard Evaluation Report. Artesian Industries, Mansfield,
OH. HETA 84-0066-1883. Cincinnati, OH: National Institute for Occupational Safety and Health. (March).
OSHA SEP Inspection Report 300384435. OSHA Special Emphasis Program (SEP) Inspection Report 300384435. Includes pages from related inspection 300384468. 4-33 August 2008 Draft Do Not Cite or Quote
Phelps, G.W. and J.B. Watchman, Jr. 1986. Ceramics, General Survey. In: Gerhartz, W., Y.S. Yamamoto, F.T. Campbell, eds. Ullmann's Encyclopedia of Industrial Chemistry, Vol.A.6, 5th ed. New York,
NY: VCH. pp. 1, 12-34, 40-42. U.S. Census Bureau. 2005. County Business Patterns, 2004. Accessed online at <http://www.census.gov/epcd/cbp/view/cbpview.html>, April, 2007.
Weill, H., R.N. Jones, and W.R. Parkes. 1994. Silicosis and Related Diseases. In: Parkes, W.R. ed. Occupational Lung Disorders, 3rd ed. Oxford: Butterworth-Heinemann Ltd. pp. 285-339. Whirl-air. 2003. Personal communication between representative of Whirl-air, Minneapolis, MN and ERG. January 9. 4-34 August 2008 Draft Do Not Cite or Quote
Akbar-Khanzadeh, F. and R. L. Brillhart. 2002. Respirable Crystalline Silica Dust Exposure During Concrete Finishing (Grinding) Using Hand-Held Grinders in the Construction Industry. Annals of Occupational Hygiene, 46(3):341-346.
APA. 2000. Architectural Precast Concrete Finishes Guide. Architectural Precast Association internet web site <www.archprecast.org/finishes.htm >. (Accessed August 28). Bureau of Labor Statistics. 2005. Occupational Employment Statistics Survey, 2004. Accessed online at <http://www.bls.gov/OES/>, April, 2007.
Cecala, Andrew B., Robert J. Timko, Edward D. Thimons. 2000. Methods to Lower the Dust Exposure of Bag Machine Operators and Bag Stackers. Applied Occupational and Environmental Hygiene, 15(10):751-765.
Concrete Product Industry Associate. 2001. Personal communication between Concrete Product Industry Associate and Eastern Research Group, Inc. (October 4) Concrete Product Industry Representative A. 2000. Personal communication between Concrete Product Industry Representative A and Eastern Research Group, Inc. (August 17). Concrete Product Manufacturer C. 2000. Personal communication between Concrete Product Manufacturer C and Eastern Research Group, Inc. (August 18). Concrete Product Manufacturer D. 2000. Personal communication between Concrete Product Manufacturer D and Eastern Research Group, Inc. (August 16). Concrete Product Manufacturer E. 2000. Personal communication between Concrete Product Manufacturer E and Eastern Research Group, Inc. (August 18). Concrete Product Manufacturer F. 2000. Personal communication between Concrete Product Manufacturer F and Eastern Research Group, Inc. (August 17). Concrete Product Manufacturer G. 2000. Personal communication between Concrete Product Manufacturer G and Eastern Research Group, Inc. (August 21).
Croteau, G. A. 2000. The Effects of Local Exhaust Ventilation Controls on Dust Exposures During Masonry Activities. Masters Thesis. University of Washington. June
ERG. 2002. Site Visit to Precast Concrete Manufacturing Facility B. September. 5-28 August 2008 Draft Do Not Cite or Quote
Fairfax, Richard. (ed.) 1998. Exposure to Crystalline Silica in a Concrete Packaging Operation. Applied Occupational and Environmental Hygiene, 13(1):7-8. Haney. R. 2000. Presentation at Triagency Workshop - Measurement and Control of Silica (June 28)
Master Builders, 2000. Master Builders Inc. product literature for Preco EAC-S (regular and deep) surface retarder.
NIOSH. 1984. Comprehensive Safety Recommendations for the Precast Concrete Products Industry.
NIOSH, 1998. Environmental Surveillance Report: Construction Site #16, Covington, Kentucky. National Institute for Occupational Safety and Health, Morgantown, WV. June.
NIOSH. 1999a. Control Technology and Exposure Assessment for Occupational Exposure to Crystalline Silica: Case 06 - Monument Manufacturing. ECTB 233-106c. Cincinnati, OH: National Institute for Occupational Safety and Health. (August).
NIOSH. 1999b. Control Technology and Exposure Assessment for Occupational Exposure to Crystalline Silica: Case 12 - Concrete Block Manufacturing. ECTB 233-112c. Cincinnati, OH: National Institute for Occupational Safety and Health. (September).
NIOSH. 1999c. Control Technology and Exposure Assessment for Occupational Exposure to Crystalline Silica: Case 15 - Concrete Cutting. ECTB 233-115c. Cincinnati, OH: National Institute for Occupational Safety and Health.
NIOSH. 1999d. Control Technology and Exposure Assessment for Occupational Exposure to Crystalline Silica: Case 01 - A Ready-Mix Concrete Plant. ECTB 233-101c. Cincinnati, OH: National Institute for Occupational Safety and Health.
NIOSH. 2000a. Control Technology and Exposure Assessment for Occupational Exposure to Crystalline Silica: Case 25 - Concrete Pipe Manufacturing. ECTB 233-125c. Cincinnati, OH: National Institute for Occupational Safety and Health. (March).
NIOSH. 2000b. Control Technology and Exposure Assessment for Occupational Exposure to Crystalline Silica: Case 27 - Pre-Cast Concrete Shape Manufacturing. ECTB 233-127c. Cincinnati, OH: National Institute for Occupational Safety and Health. (March).
NIOSH. 2000c. Control Technology and Exposure Assessment for Occupational Exposure to Crystalline Silica: Case 28 - Pre-Cast Concrete Utility Products Manufacturing. ECTB 233-128c. Cincinnati,
NIOSH. 2001. Control Technology for Resdy-mix Truck Drum Cleaning (EPBH 247-19). U.S. Department of Health and Human Services, Public Health Service, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, Division of Physical Sciences and Engineering, Cincinnati, OH. May 31.
NIOSH. 2003-EPHB 282-11a. In-depth survey report: Control of respirable dust and crystalline silica from breaking concrete with a jackhammer - at Bishop Sanzari Companies, North Bergen, NJ (EPHB 282-11a). U.S. Department of Health and Human Services, Public Health Service, Centers for 5-29 August 2008 Draft Do Not Cite or Quote Disease Control and Prevention, National Institute for Occupational Safety and Health, Division of Physical Sciences and Engineering, Cincinnati, OH. February.
Williams, D.R. and K. Sam, 1999. "Illinois Ready-Mixed Concrete Association Industrial Hygiene Study: October 1997 through June 1999." Illinois Department of Commerce and Community Affairs, Illinois On-Site Consultation Program, 100 West Randolph Street, Chicago, Illinois. [Unpublished Data]
Simcox. 1999. Simcox, N.J., D.Lofgren, J. Leons, J. Camp. Silica Exposure During Granite Countertop Fabrication. Applied Occupational and Environmental Hygiene, 14(9):577-582. U.S. Census Bureau. 2005. County Business Patterns, 2004. Accessed online at <http://www.census.gov/epcd/cbp/view/cbpview.html>, April, 2007. 5-30 August 2008 Draft Do Not Cite or Quote
Zalk, David. 2000. Exposure assessment strategy for the reduction of airborne silica during jackhammering activities. Presentation. American Industrial Hygiene Conference and Exposition. May 20-25, 2000: Orlando, FL.
Zalk, David. 2001. Personal communication. Phone call between Mr. Zalk of Lawrence Livermore Laboratory and ERG. (January 23.) 5-31 August 2008 Draft Do Not Cite or Quote
Dental Laboratories, 2004 (NAICS 339116) No. of Establishments No. of Employees No. of Dental Technicians Establishments with <20 Employees Establishments with 20 - 99 Employees Establishments with >99 Employees 7,250 47,800 35,230 6,813 (94%) 406 (6%) 31 (0%) Source: U.S. Cenus Bureau, 2005, Bureau of Labor Statistics, 2005.
EXPOSURE PROFILE To evaluate the respirable crystalline silica exposures of dental technicians, ERG relied primarily on the full-shift PBZ respirable quartz and respirable cristobalite exposure monitoring data obtained during its site visit to a dental laboratory (a facility with fewer than 20 employees) (ERG, 2000). Additionally,
ERG considered full-shift PBZ results obtained from 11 dental studios by the New Jersey Department of Health and Senior Services (NJ DHSS, 2006). [The data from these two sources are discussed in detail below.]
ERG also reviewed OSHA Integrated Management Information System (IMIS) silica monitoring data collected during inspections of dental laboratories from 1980 through 1997. The IMIS lists seven readings for SIC 8072 (Dental Laboratories), all below the limit of detection for quartz (12 Φg/m; in a 480-minute sample). These IMIS data were not used to develop the exposure profile calculations presented in this section, however, because there is not enough information about worker activities and conditions present during sampling to allow for detailed evaluation of the exposure data. Nonetheless, these IMIS readings appear to agree with the findings of ERG=s site visit, in which the full-shift respirable crystalline silica exposures of all five dental technicians sampled were below the LOD.
ERG was not able to identify any other source of published silica exposure monitoring data for dental technicians. Several publications, however, indicate the potential for dental technicians to be exposed to elevated levels of silica (e.g., Rom, et al., 1984; Bernstein, M. et al., 1994; Nayebzadeh et al., 1999). Additionally, at least six cases of silicosis in dental technicians (4 in Michigan and 2 in New Jersey) have been reported by states currently participating in the SENSOR silicosis surveillance program (Schill, 2003). Nevertheless, given the typical latency period for silicosis development, these cases may not represent current conditions but long past conditions in dental laboratories. They indicate, however, the potential for elevated exposure. It is believed that these cases arose primarily in dental technicians who worked in poorly controlled facilities performing a single activity with high exposure, such as abrasive blasting with quartz (Schill, 2003). Reports such as these suggest that past silica exposure levels were significantly higher in some dental laboratories. It is also possible that the information available to ERG underestimates current silica exposure levels for dental technicians; however, in the absence of additional exposure information, ERG has relied on the results that are available.
NJ DHSS Site Visit Findings from 13 Dental Laboratories, 2003-2005. Results obtained by the New Jersey Department of Health and Senior Services are similar to ERG’s site visit findings, but suggest slightly greater potential for a modest level of exposure. From 2003 to 2005 investigators conducted personal breathing zone (PBZ) air monitoring of dental laboratory technicians at 13 New Jersey dental laboratories and obtained 26 full-shift breathing zone respirable silica results (quartz and cristobalite were not differentiated) (NJ DHSS, 2006). The technicians performed activities such as working with plaster, making investment material, casting metal, breaking investments, cleaning castings, performing abrasive blasting, and forming porcelain. Twenty-one (81 percent) of the 26 full-shift samples are less than 25Φg/m;.1 Another four of the 26 results (15 percent) fall between 25 and 50 Φg/m;, while one value exceeds 50 Φg/m; by a small amount.
DHSS, 2006). August 2008 Draft Do Not Cite or Quote Table 6-5 Summary of Full-Shift PBZ Respirable Quartz Exposures of Workers in Dental Laboratories (NAICS 339116) Job Category Dental Technician Number of Samples Range (Φg/m;) Mean* (Φg/m;) Median* (Φg/m;) #5 to 58 * In order to include the nondetected results in the calculations of means and medians, the detection limit value is assigned to each result reported as less than the method detection limit. Source: ERG (2000); NJ DHSS (2006) As Table 6-6 indicates, the vast majority of the available respirable quartz monitoring results were less than or equal to 50 Φg/m;. To develop the exposure profile presented in Table 6-7 below, ERG applied the results presented in Table 6-6 to the total number of dental technicians in this industry. Further information regarding the employee estimates is presented in the industry profile and process description. Table 6-6 Distribution of Full-Shift PBZ Respirable Quartz Exposures of Workers in Dental Laboratories (NAICS 339116) No. of Results in Range Job Category Dental Technician Total Φg/m; >25 to #50 Φg/m; >50 to #100
American Dental Association. 1999. Dental Laboratory Technology. <http://www.ada.org/prac/careers/fstech.html> September. 6-10 August 2008 Draft Do Not Cite or Quote Bureau of Labor Statistics. 2005. Occupational Employment Statistics Survey, 2004. Accessed online at <http://www.bls.gov/OES/>, April, 2007. Dental Laboratory A. 2000. Personal communication. Phone call between the owner/manager of Dental Laboratory A and ERG. June 13. Dental Laboratory B. 1999. Personal communication. Phone call between Dental Laboratory B and ERG. December 9.
ERG. 2000. Site Visit to Dental Laboratory A. ERG, Arlington, VA. August 3.
NADL. 2002. Essential Facts: A Dentist=s Guide to Dental Technology Certification. <www.nadl.org/html/facts.pdf>. January.